TY - THES A1 - Arlt, Christiane T1 - Clinical Effect of Tear Layer Thickness on Corneal Edema During Scleral Lens Wear N2 - Purpose: Although the frequency in which practitioners are fitting scleral contact lenses is increasing, the recommendation for proper tear layer depth (thickness) varies amongst experts. The main goal of this paper is to clinically verify the effect of varying tear layer depths on induced corneal edema during lens wear. Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their right eye. Each of them was fit with two different lenses: one with an apical clearance of 200 μm and another with an apical clearance of 600 μm. They wore the lenses for 8 hours on two different days, with at least a one week wash-out period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry measurements were taken one day prior to lens wear at 4 p.m., on the day of wear prior to lens application, and after removal of the lenses at 4 p.m. Measurements were collected using both the Pentacam® HR Corneal Tomographer, as well as the Visante Anterior Segment Optical Coherence Tomographer (OCT). The apical clearance was measured using the Visante OCT at two intervals during the test day: immediately after application of the lens and immediately prior to the removal of the lens. Results: In this study, there was found to be no significant difference in corneal edematous response during lens wear between the two test groups. The study shows that the eyes with the lenses have a statistically significantly thicker cornea compared to the non-lens-wearing eye after wearing either lens for 8 hours, lying within clinically and physiologically acceptable limits. Conclusion: Our clinical results do not correlate with current theoretical calculations, which predict a greater amount of corneal swelling with increasing tear layer thickness. It has to be evaluated if the effect on corneal edema changes with longer wearing periods, larger samples or other influences. Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer thickness, vaulting, apical clearance KW - Kontaktlinsen KW - Studie Y1 - U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1438 ER - TY - THES A1 - Breher, Katharina T1 - The effect of the optical design of multifocal contact lenses on choroidal thickness N2 - Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness. Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens. Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness. Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control. N2 - Ziel: Studien haben gezeigt, dass multifokale Kontaktlinsen das Fortschreiten der Myopie reduzieren können. Jedoch ist der Mechanismus dahinter noch unbekannt. Eine Hypothese besagt, dass die Additionszonen innerhalb der Multifokallinsen myopen Defokus auf der Netzhaut erzeugen, was zu einer Zunahme der Aderhautdicke und folglich zu einem gehemmten Längenwachstum des Auges führt. Aufgrund dessen haben wir den Effekt von verschiedenen optischen Designs von Multifokallinsen auf die Aderhautdicke unterssucht. Methoden: 18 myope Studenten trugen jeweils 30 Minuten lang vier verschiedene Kontaktlinsen auf ihrem rechten Auge ((1) Einstärkenlinse mit Fernkorrektur (2) Einstärkenlinse mit +2.50 D Unterkorrektur (3) Multifokallinse mit zentraler Fernzone, Addition +2.50 D, (4) Multifokallinse mit zentraler Nahzone, Addition +2.50 D). Vor und nach jeder Tragesession wurde die makuläre Aderhautdicke der Probanden automatisch ausgewertet, sowie die Glaskörperkammertiefe gemessen. Ebenfalls wurde die periphere Refraktion für jede Linse mittels exzentrischer Photorefraktion bestimmt. Ergebnisse: Es gab keine signifikanten Änderungen der Aderhautdicke und Glaskörperkammertiefe. Die Aderhautdicke nahm am meisten mit der Fern-Multifokallinse und der unterkorrigierten Einstärkenlinse zu, gefolgt von der Nah-Multifokallinse und der fernkorrigierten Einstärkenlinse (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm and +0.9 ± 11.2 μm jeweils). Außerdem erzeugt die ferndominante Multifokallinse im Vergleich zu der nahdominanten Multifokallinse und der Fern-Einstärkenlinse ein myoperes Refraktionsprofil. Änderungen der Glaskörpertiefe erfolgten in umgekehrter Richtung zu den Änderungen der Aderhautdicke. Schlussfolgerung: Multifokallinsen haben bei kurzer Tragedauer keinen signifikanten Einfluss auf die Aderhautdicke. Daraus lässt sich schließen, dass sie nicht der Hauptfaktor ist, der zu dem Kontrolleffekt bei Multifokallinsen führt. KW - Myopia KW - Defocus KW - Choroidal thickness KW - Multifocal contact lenses Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-6800 ER - TY - THES A1 - Eißner, Jürgen T1 - Differenzierung mit Eichenholz aromatisierter Weine mittels multivariater Datenanalyse des Aromaprofils N2 - In der Arbeit wurde eine GC-MS-Methode zur Quantifizierung von 21 identifizierten Aromastoffen, die aus getoasteten Eichenholzchips in Wein übergehen, entwickelt. Diese Methode wurde für die ausgewählten Substanzen unter Einbeziehung der Festphasenextraktion mittels des internen Standard 2-Octanol kalibriert. Die Analyte zeigten mit Ausnahme von Syringaaldehyd lineares Verhalten bei Korrelationen von 0,986 bis 0,999. Die Nachweisgrenzen, die über das Signal-zu-Rausch-Verhältnis ermittelt wurden, lagen im Bereich von 0,03 bis 0,47 µg/l. Der Test auf Wiederholbarkeit ergab mit Werten von kleiner 10% für die meisten untersuchten Stoffe in Rot- und Weißwein zufrieden stellende Werte. Mit der entwickelten Methode wurden Barriqueweine des Handels und selbst hergestellte Chipsweine untersucht. Bei der Untersuchung der Chipsweine, die nach einem vollen Versuchsplan hergestellt wurden, zeigten sich signifikante Einflüsse durch die Faktoren Kontaktzeit, Toastung und Größe sowie durch die Wechselwirkung Toastung-Größe auf die Konzentrationen der meisten identifizierten Substanzen. Bei der Betrachtung der Konzentrationen der ausgewählten Substanzen in Barriqueweinen zeigten sich signifikante Unterschiede zu den entsprechenden Konzentrationen in den hergestellten Chipsweinen. Diese signifikanten Unterschiede wurden mittels Hauptkomponentenanalyse und anschließender Klassifizierung über die SIMCA-Methode dazu genutzt, um die önolgischen Verfahren Chipsbehandlung und Barriquefasslagerung zu differenzieren. KW - Chemische Analyse KW - Multivariate Analyse KW - Weinanalytik KW - Multivariate Statistik KW - Massenspektrometrie Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus-15 ER - TY - THES A1 - Felgner, Sebastian T1 - Vergleich und Therapieempfehlung von Benetzungsmitteln nach Inhaltsstoffen und Darreichung N2 - Das trockene Auge ist eine komplexe Erkrankung des vorderen Augenabschnitts. Es gibt eine Vielzahl von Ursachen, sowie eine Vielzahl an Therapiemöglichkeiten. Diese Arbeit befasst sich mit Benetzungsmitteln als Therapieform. Es existieren verschiedene Benetzungsmittel, die sowohl von Augenärzten, als auch von Optometristen und Optikern verabreicht werden. Es wird eine Übersicht über alle Benetzungsmittel erstellt, die in der Schweiz von Optometristen verabreicht werden können und ein Schema zur Anwendung je nach Diagnose entwickelt. N2 - Dry eye is a complex disease of the anterior part of the eye. There is a variety of possible causes, as well as a variety of therapy possibilities. This paper deals with artificial tears as form of therapy. There exist different artificial tears, which can either be administered by the general ophthalmologist, or the optometrist and optician. An overview of all artificial tear products administered by optometrists in Switzerland is created and a scheme of treatment depending on the diagnosis is developed. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9879 ER - TY - THES A1 - Gier, Yvonne Eva T1 - Eine Analyse des vorderen Augenabschnitts mit dem OCULUS Pentacam® CSP Report N2 - Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann. N2 - A detailed evaluation of the corneo-scleral profile is of particular relevance for the fitting of soft contact lenses and scleral lenses. This study aims to describe the profile of the limbal sclera using the unit CSP-Report of the OCULUS Pentacam® Basic. The aim is to check whether the CSP-Report confirms the results of previous studies and can, therefore, be used to simulate scleral lenses in the future. KW - Scheimpflugkamera KW - Pentacam® KW - vorderer Augenabschnitt KW - Scheimpflug technology KW - limbal sclera contour Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9718 ER - TY - THES A1 - Haist, Jonathan T1 - Red Teaming N2 - Zu Beginn der Arbeit wurden die theoretischen Grundlagen zu Penetrationstest, Audit und Red Teaming beschrieben. In den rechtlichen Rahmenbedingungen wurden betroffene Gesetze unter die Lupe genommen. Anschließend wurde eine Marktforschung bestehend aus einer Primär- und einer Sekundärmarkforschung durchgeführt. Die Sekundärforschung beschreibt die Angebote und Dienstleister, die auf dem Markt Red Teaming anbieten. Daraus wurden Unternehmen aus dem DACH-Raum für die Interviews der Primärforschung ausgewählt. Das Red Team muss ein vorher definiertes Ziel erreichen. Das Red Team führt in Abstimmung mit dem White Team Angriffe durch, die technische, physische und menschliche Komponenten betreffen können. Welche Komponenten verwendet werden, unterscheidet sich nach Projekt und Dienstleister. Das Blue Team hat die Aufgabe, die Angriffe zu erkennen und darauf zu reagieren. Mit dem gesammelten theoretischen Wissen und den Interviews wurden die Methoden verglichen und eine Methodik zur Einordnung erstellt. Das Red Teaming, Penetrationstests und Audits sind für unterschiedliche Situationen nützlich. Um die Auswahl zu erleichtern, ist es sinnvoll, die Ziele zu definieren, die mit dem Test erreicht werden sollen. Als dritter Indikator ist der Scope hilfreich, da ein Penetrationstest eine technische Prüfung darstellt und beim Audit oder Red Teaming oftmals eine ganzheitliche Betrachtung der Organisation erfolgt. Im letzten Abschnitt wird eine praktikable Methode zur Durchführung von Red Teaming beschrieben. Hierzu wurden Thesen auf Grundlage des gesammelten Wissens aufgestellt. Die Arbeit endet mit einem Fazit und den Zukunftsaussichten von Red Teaming. Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9505 ER - TY - THES A1 - Karmis, Marios T1 - The use of the direct ophthalmoscope in a “modern” practice and the development of a more digitalized ophthalmoscope as a project N2 - The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9725 ER - TY - THES A1 - Krasňanský, Michal T1 - The evaluation of a new iPad Aniseikonia Test N2 - Purpose The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new computer-based test designed for measuring aniseikonia in vertical direction. The iPad Test uses red-green anaglyphs. Methods Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The measurement was performed in dark condition with appropriate correction of refractive error. All subject were patients with normal vision with no anisometropia or other ocular problem. Results: Afocal size lenses of known magnification were used to induce aniseikonia. 5 measurements were taken in each subject, ranging from zero to 7 % magnification. When using the regression analysis, the slope of the fitted line significantly differs from 1. The average slope of regression line is 0,58. Conclusions: Only moderate accuracy was found for tested target size and orientation. In all cases the iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross assessment of anisometropia in clinical practice it could be successfully used. Further study with different target size should be addressed. Y1 - U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1469 ER - TY - THES A1 - Majdak, Vjekoslav T1 - Influence of Physiological Factors on Stereopsis N2 - A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis. To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years). The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases. The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances. Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%. Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x). Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA). Y1 - U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1488 ER - TY - THES A1 - Mattern, Ann-Isabel Britta T1 - Low-Level Neural Processing of Photoreceptor Neuron Signals N2 - Novel myopia control spectacle lenses induce peripheral contrast reduction via optical diffusion. It is suggested, that the contrast reduction alters retinal processes in the low-level neural circuity, leading to an inhibition of eye growth. The purpose of this thesis is to evaluate the influence of full-field contrast reduction on low-level neural processing of the retina, described by the edge contrast sensitivity. N2 - Ein neuartiges Brillenglas zur Myopiekontrolle erwirkt eine Kontrastreduktion durch optische Diffusion. Der zugrundeliegende Mechanismus und Hypothese legen nahe, dass durch optische Diffusion die neuro-retinalen Prozesse verändert werden und somit das Augenwachstum gehemmt wird. Der Zweck dieser Arbeit ist es, den Einfluss von induzierter Kontrastreduzierung auf die neuronalen Prozesse der Netzhaut zu zeigen, welche durch die Kantenkontrastempfindlichkeit beschrieben werden. KW - Myopia Control KW - Diffusion KW - Edge Detection KW - Myopie Kontrolle KW - Kantendetektion Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9959 ER - TY - THES A1 - Müller-Amon, Niklas T1 - Ultra-Widefield-cSLO vs. Konventionelles cSLO BT - Sollte die Untersuchung der peripheren Netzhaut der Standard in der optometrischen Praxis werden? N2 - Demographische Veränderungen durch eine zunehmende Alterung der Gesellschaft und eine Zunahme an Erkrankungen wie der AMD, des Glaukoms und der diabetischen Retinopathie stellen ophthalmologische Versorgungs- und Vorsorgemaßnahmen in Deutschland vor immer größere Herausforderungen. Einen wesentlichen Beitrag zur Sicherung der Vorsorgemaßnahmen können in der Zukunft Optometristen leisten. Mit Hilfe modernster Technologien, wie dem Ultra-Widefield-cSLO (Optos Daytona, können auch bei kleinen Pupillendurchmessern 200° Aufnahmen vom Augenhintergrund erstellt werden. N2 - Demographic changes due to an aging society and an increase in diseases such as AMD, glaucoma and diabetic retinopathy pose ever greater challenges for ophthalmological care and preventive measures in Germany. Optometrists will be able to make a significant contribution to safeguarding preventive measures in the future. Along with the help of the latest technology, such as the ultra-widefield cSLO (Optos Daytona, 200° images of the fundus of the eye can be made even with small pupil diameters. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9943 ER - TY - THES A1 - Rothe, Colleen T1 - Evaluation of Scanpath Comparison Metrics for Static and Dynamic Tasks N2 - Purpose Automated scanpath comparison metrics should deliver an objective method to evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of seven existing scanpath comparison metrics in static and dynamic tasks in order to provide a guidline that helps to decide which algorithm has to be chosen for a special kind of task. Methods The applicability of the algorithms for a static, visual search task and a dynamic, interactive video game task as well as their constraints and limitations were tested. Therefore, binocular gaze data were recorded by using the eye tracking system The Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance measures from 21 subjects were used in order to create scanpath groupings for which a relevant effect of dissimilarity was to be expected. Objective task performance measures such as task performance time were statistically evaluated and compared to the results gained by the comparison metrics. Results Four of the algorithms being used successfully identified differences for static and dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model. ScanMatch was very sensitive for the static task but not applicable to the dynamic task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis failed to detect any effect. Conclusion The applicability of scanpath comparison metrics depends on the state of the task, respectively on the kind of experimental set up. In future, the application area for eye tracking will expand and an improvement of automated scanpath comparison metrics is therefore required. KW - Eye tracking KW - Scanpath KW - Comparison metrics KW - Visual search KW - Fixation KW - Mustererkennung Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1633 ER - TY - THES A1 - Smuglova, Ekaterina T1 - Prevalence of vision disorders among school-aged children in Russia N2 - This research project is of particular importance since there is a lack of adequate data on pediatric eye and vision disorders in Russia, particularly in the Volga region. In the present study, we estimate the prevalence of vision disorders among school-aged children who participated in a vision screening program in Samara, Russia. The relationship between learning-related visual dysfunctions is explored in depth, such to illustrate the connection between vision and learning. Hence, a key feature in this study is the inclusion of binocular vision disorders among the conditions tested. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-9705 ER - TY - THES A1 - von der Heide, Andreas T1 - Fitting Soft Multifocal Customized Contact Lenses for Myopia Control BT - A Literature Review N2 - The increasing prevalence of myopia throughout the industrialized world in recent decades has caused costs and problems for the eye health. Changed lifestyle and behavior are the main causes. For the pathogenesis of myopia, the amount of time spent outdoor and near activities play an important role. Various options for the treatment of myopia have been described as effective in the literature. Normal single vision glasses and contact lenses can only provide clear vision, but do not reduce myopia progression. Orthokeratology shows a slowing of axial growth, but has an increased risk of infectious keratitis. Low-dose atropine (0.01%) is currently the best pharmacological option. It proved safe, effective and showed the least rebound effect with negligible side effects. Other options for the treatment of myopia include special glasses, behavioral changes and prolonged outdoor exposure (to prevent the onset of myopia), as well as other methods. An increasingly important myopia management option is multifocal contact lenses, that provide a peripheral treatment zone producing myopic defocus. Such myopia control lenses are available as customized or as daily or monthly lenses. Children benefit from wearing contact lenses more than just having refractive error correction and myopia control, they have a better self-esteem and improved quality of life. The numerous findings on the safety and efficacy of soft multifocal distance center contact lenses in children to reduce the progression of myopia suggest that this modality should be considered as a main treatment option. Less, but similar to orthokeratology, when wearing soft lenses there is a risk of developing potentially serious complications such as microbial keratitis. The introduction of child-appropriate risk minimization strategies, and patient and parent education with regular monitoring is essential and leads to successful contact lens wear. This literature review summarized the actual knowledge about myopia management, prevalence, etiology and the visual and healthy consequences of myopia. The three currently most important strategies for slowing the progression of myopia are soft multifocal distance center contact lenses, Orthokeratology and low-dose atropine ophthalmic drops. N2 - Die zunehmende Verbreitung von Kurzsichtigkeit in der gesamten industrialisierten Welt in den letzten Jahrzehnten hat Kosten und Probleme für die Augengesundheit verursacht. Veränderungen im Lebensstil und Verhalten sind die Hauptursachen. Für die Pathogenese der Myopie spielt die Zeit, die im Freien und mit Aktivitäten in der Nähe verbracht wird, eine wichtige Rolle. Verschiedene Möglichkeiten zur Behandlung von Myopie wurden in der Literatur als wirksam beschrieben. Normale Einstärkenbrillen und Kontaktlinsen bieten nur eine klare Sicht, verringern jedoch nicht das Fortschreiten der Myopie. Die Orthokeratologie zeigt eine Verlangsamung des axialen Wachstums, hat jedoch ein erhöhtes Risiko für eine infektiöse Keratitis. Niedrig dosiertes Atropin (0,01%) ist derzeit die beste pharmakologische Option. Diese erwies sich als sicher, wirksam und zeigte den geringsten Reboundeffekt mit vernachlässigbaren Nebenwirkungen. Andere Optionen für die Behandlung von Myopie umfassen spezielle Brillen, Verhaltensänderungen und längerer Aufenthalt im Freien (um das Einsetzen von Myopie zu verhindern) sowie andere Methoden. Eine zunehmend wichtige Option für das Myopiemanagement sind multifokale Kontaktlinsen, die eine periphere Behandlungszone bieten, die einen peripheren myopischen Defokus hervorruft. Solche Myopiekontrolllinsen sind als kundenspezifische oder als Tages- oder Monatslinsen erhältlich. Kinder profitieren vom Tragen von Kontaktlinsen nicht nur von der Korrektur von Brechungsfehlern und der Kontrolle Ihrer Kurzsichtigkeit, sondern auch von einem besseren Selbstwertgefühl und einer verbesserten Lebensqualität. Die zahlreichen Ergebnisse zur Sicherheit und Wirksamkeit von weichen, multifokalen Kontaktlinsen mit Fernsicht im Zentrum bei Kindern zur Verringerung des Fortschreitens der Myopie legen nahe, dass diese Modalität als Hauptbehandlungsoption in Betracht gezogen werden sollte. Weniger, aber ähnlich wie in der Orthokeratologie, besteht beim Tragen weicher Linsen das Risiko, dass potenziell schwerwiegende Komplikationen wie mikrobielle Keratitis auftreten. Die Einführung kindgerechter Risikominimierungsstrategien sowie eine regelmäßige Überwachung und Patienten- und Elternaufklärung sind unerlässlich, und führen zu einem erfolgreichen Tragen von Kontaktlinsen. Diese Literaturübersicht fasst das aktuelle Wissen über Myopiemanagement, Prävalenz, Ätiologie und die visuellen und gesundheitlichen Konsequenzen von Myopie zusammen. Die drei derzeit wichtigsten Strategien zur Verlangsamung des Fortschreitens der Myopie sind weiche, multifokale Kontaktlinsen mit Fernsicht im Zentrum, Orthokeratologie und niedrig dosierte Atropin-Augentropfen. KW - Myopia KW - customized KW - soft multifocal contact lens KW - peripheral myopic defocus KW - myopia management Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-6837 ER - TY - THES A1 - Vujko Muždalo, Nataša T1 - Measurement of Dynamic Visual Acuity with Augmenting Landolt Rings N2 - Purpose The purpose of this study was to investigate the correlation of measured visual acuity (VA) both static and dynamic obtained with static and dynamic measuring tests, as well as, response time to visual stimulus and analysis of its influence on dynamic visual acuity. The aim was to compare the results gathered for the three age groups and analyze the possible differences. Methods The test groups consisted of 75 subjects between 10 and 60 years old, categorized in three age groups. The measurements of static and dynamic visual acuity and reaction time were conducted. The set of nine tests (five with radial magnification speed and four simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure dynamic visual acuity and the set of two tests for reaction time measurement. Results Compared to static visual acuity in both tests, the results obtained with measurements of dynamic visual acuity resulted in lower values depending on Landolt ring size and magnification speed of animation. In average, the dynamic visual acuities in tests with different magnification speeds were lower than static by 0.4 visual acuity units, or 31% and the average of dynamic visual acuity after subtracting motoric component (reaction time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while at 130 km/h average drop for younger and middle age groups was 37% and for older group was 44% and after subtracting motor component values for 72 km/h speed simulation average drop in visual acuity values was 23% for all three groups; for 130 km/h speed simulation younger and middle aged group average drop of visual acuity was 20% and with older group it was 24%. Conclusion The tests used in this study were simple and fast and revealed significant difference between static and dynamic visual acuity and influence of reaction time on dynamic Nataša Vujko Muždalo Abstract 2 visual acuity values. It is hoped that this thesis will be a positive contribution in testing and training of dynamic visual and sensory response skill with drivers, sportsmen and people with visual-motor dysfunction. Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT), motoric component, dynamic visual acuity test, reaction time test, radial increase in size Y1 - U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1474 ER - TY - THES A1 - Wyss, Michael T1 - FoCoSi - Follicular-like Conjunctivitis associated with Siliconhydrogels N2 - Abstract 1.1 Purpose The purpose of this study is to prescribe follicular-like conjunctivitis associated with Siliconhydrogels (FoCoSi) in silicone hydrogel contact lens wearers as a novel subtype of the well prescribed contact lens induced papillary conjunctivitis (CLPC). 1.2 Methods 1211 patients who wore silicon hydrogels were included in this prospective, nonrandomised, single center study. Subjective symptoms and clinical signs were evaluated for daily wear (DW) and continuous wear (CW) populations for several (Lotrafilcon A, Lotrafilcon B, Senofilcon A, Galyfilcon A) silicon hydrogel lens types. CCLRU and other specifically developed grading scale were utilized for evaluation. Grading of 2 and above was rated as clinically significant. Statistical evaluation was performed for eyes rather than subjects. 1.3 Results The clinical presentation of FoCoSi could be confirmed and showed an incidence of 3.8%. Lotrafilcon A followed by Senofilcon A on a CW modality presented, with a risk ratio of 2.49 and 1.53 respectively, the highest affinity for developing FoCoSi. Fluorescein positive spots showed the closest correlation with subjective symptoms reported by patients and divided FoCoSi into an active and dormant form. Besides Protein, Lipid deposition on the contact lens surface and air pollution like Ozone or fine and ultrafine particles seems to be important factors in developing FoCoSi, whereas mechanical irritation played a minor role. 1.4 Conclusion FoCoSi is a novel and relevant subtype of CLPC. Further studies should be performed to validate these findings and clear up several questions about the aetiology of FoCoSi and CLPC. Keywords: Giant papillary conjunctivitis (GPC), contact lens-induced papillary conjunctivitis (CLPC), follicular-like conjunctivitis associated with siliconhydrogels (FoCoSi) KW - Studie KW - Kontaktlinse KW - giant papillary conjuctivitis GPC KW - contact lens-induced papillary conjuctivitis CLPC KW - follicular-like conjunctivitis associated with siliconhydrogels FoCoSi Y1 - U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-1452 ER - TY - THES A1 - Zurbuchen, Lukas T1 - Die richtige Konsequenz beim UV-Schutz: Myopiekontrolle versus Sonnenlichtbedingte Veränderungen an den Augen. Ein review. T1 - Keep the balance of UV-protection: Myopia control versus sunlight-caused ocular changes. A review. N2 - Fragestellung: Ist es sinnvoll im Kindesalter restriktiv einen UV-Schutz für die Augen anzuwenden, obwohl UV-Strahlung eine schützende Wirkung für das Entstehen einer Myopie hat? Einleitung: Die Myopie ist eine typischerweise durch Längenwachstum des Augapfels verursachte Fehlsichtigkeit mit stark steigender Prävalenz in den letzten Jahrzenten. UV-Strahlung hat auf die Haut und die Augen eine Vielzahl negativer Auswirkungen. Nebst der akuten Photokeratitis sind Pinguecula, Pterygium, Plattenepithelneoplasie, Katarakt, AMD und maligne Melanome chronische Veränderungen. Andererseits bremst UV-Strahlung das Fortschreiten des Augenlängenwachstums. Modellrechnung: Mittels dem evidenzbasierten Modellrechner kann das Risiko einer Myopie und deren Stärke anhand des Jahrgangs, der Sonnenschutzanwendung, der familiären Prädisposition, der Zeit im Freien und des Bildungsgrades berechnet werden. Gelegentlich angewandter Sonnenschutz hat gegenüber häufig angewandtem Sonnenschutz einen Schutzfaktor für die Myopieentstehung von 1.03. Das grösste Risiko einer Myopie kommt von der familiären Prädisposition. Diskussion: Zeit im Freien hat einen grossen hemmenden Effekt auf die Myopie, Sonnenschutzanwendung nur einen leicht Fördernden. Zudem hat Sonnenschutz einen stark hemmenden Effekt auf UV-bedingte Augen- und Hauterkrankungen. Auf Sonnenschutz der Augen zu verzichten, um eine Myopie zu verhindern oder im Fortschreiten zu bremsen, scheint unvernünftig. N2 - Purpose: Is it reasonable to use consequent UV-protection for the eyes although UV-protection has a protective effect against myopia. Introduction: Myopia is typically caused by elongation of the eyeball. This kind of ametropia has a strongly increasing prevalence in the last decades. UV-radiation has many negative consequences for the skin and the eyes. Beside the acute photokeratitis are pinguecula, pterygia, epithelial squamous cell neoplasia, cataract, age related macular degeneration and malign melanoma chronic changes. On the other hand, UV-radiation decreases or blocks the elongation of the eyeball. Model calculation: The risk for myopia can be calculated using the year of birth, the use of sun protection, family history, time spent outdoors and education level. Sometimes used sun protection versus often used sun protection protects against the development of myopia with a factor of 1.03. The biggest risk for getting myopic comes from familiar predisposition. Discussion: Time spent outdoors inhibits myopia strongly, sun protection slightly forces its development. Sun protection is a strong protective factor of UV-caused eye- and skin disease. To renounce sun protection for myopia protection seems to be unreasonable. KW - Abschlussarbeit KW - Masterarbeit AO Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bsz:944-opus4-6792 ER -