Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (12)
- Master's Thesis (12)
- Article (9)
- Report (3)
Language
- English (36) (remove)
Is part of the Bibliography
- no (36) (remove)
Keywords
- Myopia (3)
- Studie (2)
- Adjustment Process (1)
- Affliliate Marketing (1)
- Agency Theory (1)
- Artificial Intelligence (1)
- Big Data (1)
- Choroidal thickness (1)
- City Development (1)
- Comparison metrics (1)
- Cross-Cultural Training (1)
- Cultural Heritage Marketing (1)
- Defocus (1)
- Diffusion (1)
- Digitization (1)
- Diversity Marketing (1)
- Edge Detection (1)
- Eye tracking (1)
- Fixation (1)
- Germany (1)
- Geschlechterrollen (1)
- Industrial Culture (1)
- Industrial Heritage (1)
- Kantendetektion (1)
- Kontaktlinse (1)
- Kontaktlinsen (1)
- Marketing (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- National/Organizational Culture (1)
- Orthokeratologie (1)
- Orthokeratology (1)
- Scanpath (1)
- Share Repurchase (1)
- Strategic analysis (1)
- Strategische Analyse (1)
- Umweltanalyse (1)
- Undervaluation (1)
- Visual search (1)
- albinism (1)
- automotive supplier (1)
- contact lens-induced papillary conjuctivitis CLPC (1)
- customized (1)
- electric vehicle (1)
- environmental analysis (1)
- follicular-like conjunctivitis associated with siliconhydrogels FoCoSi (1)
- gender roles (1)
- genes (1)
- giant papillary conjuctivitis GPC (1)
- hybrid vehicle (1)
- low vision (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- myopia management (1)
- peripheral myopic defocus (1)
- powertrain (1)
- repeatability (1)
- soft multifocal contact lens (1)
- specialty coffee (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- two-rod test (1)
- vision therapy (1)
Strategy development is one of the crucial factors for a firm's performance. For it
to be developed, a strategic analysis has to be conducted first. It enables
companies to gain a deeper understanding of their internal and external
environment. In the present work, the specialty coffee market is closely analyzed through a strategic analysis. The focus of this study is the young company Tikuna, a coffee producer that aims to enter the German market. In this context, Tikuna's possible entry into the German market and the companies competitive capacities are analyzed. In order to implement the different tools of the analysis, extensive literature research, as well as one expert interview and a survey were conducted.
It was found that Tikuna possesses all characteristics to enter the German
market. However, due to the lack of a differentiation factor in Tikuna's value
proposition, its competitive capacity is limited to a short period of time. In this
sense, different recommendations are given in order to ensure long term success
in the market. The central one being that Tikuna has to use its main strength and
bring innovation to the market.
Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Aim Patrick J. Caroline and Mark P. Andre first reported about soft lens orthokeratology in 2005. In a number of articles in the past five years, they reported about their research on this topic and their new findings. The aim of this study was to continue the research of Patrick J. Caroline and Mark P. Andre and to collect more information about the outcome of the technique. Methods Ten subjects with low myopia from -0.25 D to -1.25 D and a refractive astigmatism from plano to -0.75 D were fitted with a -10.00 D CIBA VISION AIR OPTIX® NIGHT&DAY® silicone hydrogel contact lens and were told to wear the lenses over night and everted. Corneal topography and refraction measurements were taken after one night, one week and one month of contact lens wear. Results Eight out of ten subjects finished the study, six female and two male. The mean age of the subjects was 23.9 years. With the eight subjects who finished the study, the mean change in subjective refraction was about +1.00 D in the sphere and +0.22 D in the cylinder, with maximum changes of +1.75 D sphere and +0.75 D cylinder. The mean apical power change, measured with the topographer, was 1.11 D. Changes in K - readings ranged from slight corneal steepening in both of the meridians to 0.23 mm of corneal flattening in the horizontal meridian and 0.27 mm of corneal flattening in the vertical meridian. Corneal eccentricity decreased about 0.65 on average. The main complaints and problems were the high minus power and the decentration of the contact lens and the occurrence of ghosting at night. Conclusion The results of this study show that everted wear of a high minus silicone hydrogel contact lens can lead to orthokeratology - such as changes in corneal topography and subjective refraction. These changes range from plano to +1.75 D sphere and +0.25 D to +0.75 D cylinder but are unpredictable and vary from subject to subject. Additional studies regarding the contact lens decentration and the unpredictability of the outcome need to be done to optimize the process.
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Based on a data-driven approach, a computer-assisted workflow for the quantitative analysis of optical Kerr microscopy images of sintered FeNdB-type permanent magnets was developed. By analyzing the domain patterns visible in the Kerr image with data-driven approaches such as traditional machine learning and advanced deep learning, we can quantify grain orientation and size with a better trade-off between accuracy and higher throughput than electron backscatter diffraction (EBSD). The key distinction between traditional machine learning and advanced deep learning lies in feature extraction. Traditional methods require manual, user-dependent feature extraction from input data, while advanced deep learning achieves this automatically. The predictions from the trained models were compared to the measurements from EBSD for performance evaluation. The proposed data-driven model is trained on the dataset created from the correlative microscopy technique, which requires the images of grains extracted from the Kerr microscopy and corresponding EBSD grain orientation data (Euler angles). The fine-tuned deep learning model shows better generalization ability than the traditional machine learning models trained on the manually extracted features and resulted in a mean absolute error of less than 5° for grain orientation of the anisotropic magnet samples when evaluated against the measured EBSD values. The developed approach has reduced the measurement effort for grain orientation by 5 times and have sufficient accuracy when compared to the EBSD.
In this study, we investigate the use of artificial neural networks as a potentially efficient method to determine the rate capability of electrodes for lithium-ion batteries with different porosities. The performance of a lithium-ion battery is, to a large extent, determined by the microstructure (i.e., layer thickness and porosity) of its electrodes. Tailoring the microstructure to a specific application is a crucial process in battery development. However, unravelling the complex correlations between microstructure and rate performance using either experiments or simulations is time-consuming and costly. Our approach provides a swift method for predicting the rate capability of battery electrodes by using machine learning on microstructural images of electrode cross-sections. We train multiple models in order to predict the specific capacity based on the batteries’ microstructure and investigate the decisive parts of the microstructure through the use of explainable artificial intelligence (XAI) methods. Our study shows that even comparably small neural network architectures are capable of providing state-of-the-art prediction results. In addition to this, our XAI studies demonstrate that the models are using understandable human features while ignoring present artefacts.
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.