Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (12)
- Master's Thesis (12)
- Article (9)
Language
- English (33) (remove)
Has Fulltext
- yes (33) (remove)
Is part of the Bibliography
- no (33) (remove)
Keywords
- Myopia (3)
- Studie (2)
- Adjustment Process (1)
- Affliliate Marketing (1)
- Agency Theory (1)
- Artificial Intelligence (1)
- Big Data (1)
- Choroidal thickness (1)
- City Development (1)
- Comparison metrics (1)
Institute
The present thesis deals with alternative powertrains, focusing on electric vehicles
and hybrid vehicles and which of those alternative powertrains is considered as
sustainable for the future. It explores the question, which alternative powertrain is
worthwhile investing in for German automotive suppliers. The aim is to clarify
which of the two powertrains is already established on the market and what the
future prospects of those powertrains are. The question here is evaluated based on
the analysis of current literature as well as through the use of a SWOT analysis
and the use of the scoring model.
As a result it is clear that there is a need for alternative powertrains and the entire
automotive industry invests a lot in the development and research of alternative
powertrains. According to the German Federal Government, one million electric
vehicles should be on German roads by 2020. With pure electric vehicles, however,
the goal will be difficult to reach. Therefore, there is a lot of vested interest in
the development of hybrid vehicles on the market. It shows that the hybrid vehicle
has considerable advantages over the electric vehicle and the hybrid vehicle is
already seen as a transitional solution for pure electric vehicles. The hybrid vehicle
is also already established in the market and has better chances on the market
in the future. Therefore, it makes sense for German automotive suppliers to invest
in hybrid vehicles and to focus on this market, since there the chances of success
are greater and the future potential of this market is higher.
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.
This paper deals with the question of which factors have to be given for
successful share repurchases that create long-term shareholder value. Center of
the thesis is the agency theory and its influence on share repurchases. Based on
theoretical findings success factors for share repurchases are derived and then
verified by case studies.
The main drivers for a successful share repurchase elaborated by this paper are a
suitable long-term executive compensation, an independent board of directors and
a shareholder structure without a majority shareholder. Additionally the findings
show that tying repurchases to certain share price thresholds improves the quality
of share repurchases.
The increasing prevalence of myopia throughout the industrialized world in recent decades has caused costs and problems for the eye health. Changed lifestyle and behavior are the main causes. For the pathogenesis of myopia, the amount of time spent outdoor and near activities play an important role. Various options for the treatment of myopia have been described as effective in the literature. Normal single vision glasses and contact lenses can only provide clear vision, but do not reduce myopia progression. Orthokeratology shows a slowing of axial growth, but has an increased risk of infectious keratitis. Low-dose atropine (0.01%) is currently the best pharmacological option. It proved safe, effective and showed the least rebound effect with negligible side effects. Other options for the treatment of myopia include special glasses, behavioral changes and prolonged outdoor exposure (to prevent the onset of myopia), as well as other methods. An increasingly important myopia management option is multifocal contact lenses, that provide a peripheral treatment zone producing myopic defocus. Such myopia control lenses are available as customized or as daily or monthly lenses. Children benefit from wearing contact lenses more than just having refractive error correction and myopia control, they have a better self-esteem and improved quality of life. The numerous findings on the safety and efficacy of soft multifocal distance center contact lenses in children to reduce the progression of myopia suggest that this modality should be considered as a main treatment option. Less, but similar to orthokeratology, when wearing soft lenses there is a risk of developing potentially serious complications such as microbial keratitis. The introduction of child-appropriate risk minimization strategies, and patient and parent education with regular monitoring is essential and leads to successful contact lens wear. This literature review summarized the actual knowledge about myopia management, prevalence, etiology and the visual and healthy consequences of myopia.
The three currently most important strategies for slowing the progression of myopia are soft multifocal distance center contact lenses, Orthokeratology and low-dose atropine ophthalmic drops.
Abstract
1.1 Purpose
The purpose of this study is to prescribe follicular-like conjunctivitis associated with Siliconhydrogels
(FoCoSi) in silicone hydrogel contact lens wearers as a novel subtype of
the well prescribed contact lens induced papillary conjunctivitis (CLPC).
1.2 Methods
1211 patients who wore silicon hydrogels were included in this prospective, nonrandomised,
single center study. Subjective symptoms and clinical signs were evaluated
for daily wear (DW) and continuous wear (CW) populations for several (Lotrafilcon A,
Lotrafilcon B, Senofilcon A, Galyfilcon A) silicon hydrogel lens types. CCLRU and other
specifically developed grading scale were utilized for evaluation. Grading of 2 and above
was rated as clinically significant. Statistical evaluation was performed for eyes rather
than subjects.
1.3 Results
The clinical presentation of FoCoSi could be confirmed and showed an incidence of
3.8%. Lotrafilcon A followed by Senofilcon A on a CW modality presented, with a risk
ratio of 2.49 and 1.53 respectively, the highest affinity for developing FoCoSi. Fluorescein
positive spots showed the closest correlation with subjective symptoms reported
by patients and divided FoCoSi into an active and dormant form. Besides Protein, Lipid
deposition on the contact lens surface and air pollution like Ozone or fine and ultrafine
particles seems to be important factors in developing FoCoSi, whereas mechanical irritation
played a minor role.
1.4 Conclusion
FoCoSi is a novel and relevant subtype of CLPC. Further studies should be performed
to validate these findings and clear up several questions about the aetiology of FoCoSi
and CLPC.
Keywords: Giant papillary conjunctivitis (GPC), contact lens-induced papillary conjunctivitis
(CLPC), follicular-like conjunctivitis associated with siliconhydrogels (FoCoSi)
In the fast-growing but also highly competitive market of battery-powered power tools, cell-pack-cooling systems are of high importance, as they guarantee safety and short charging times. A simulation model of an 18 V power tool battery pack was developed to be able to evaluate four different pack-cooling systems (two heat-conductive polymers, one phase change material, and non-convective air as reference) in an application scenario of practical relevance (the intensive use of a power tool followed by cooling down and charging steps). The simulation comprises battery models of 21700 cells that are commercially available as well as heat transfer models. The study highlights the performance of the different cooling materials and their effect on the maximum pack temperature and total charging cycle time. Key material parameters and their influence on the battery pack temperature and temperature homogeneity are discussed. Using phase change materials and heat-conductive polymers, a significantly lower maximum temperature during discharge (up to 26%) and a high shortening potential of the use/charging cycle (up to 32%) were shown. In addition to the cooling material sweep, a parameter sweep was performed, varying the external temperature and air movement. The high importance of the conditions of use on the cooling system’s performance was illustrated.
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).
Laser melting manufacturing of large elements of lunar regolith simulant for paving on the Moon
(2023)
The next steps for the expansion of the human presence in the solar system will be taken on the Moon. However, due to the low lunar gravity, the suspended dust generated when lunar rovers move across the lunar soil is a significant risk for lunar missions as it can affect the systems of the exploration vehicles. One solution to mitigate this problem is the construction of roads and landing pads on the Moon. In addition, to increase the sustainability of future lunar missions, in-situ resource utilization (ISRU) techniques must be developed. In this paper, the use of concentrated light for paving on the Moon by melting the lunar regolith is investigated. As a substitute of the concentrated sunlight, a high-power CO2 laser is used in the experiments. With this set-up, a maximum laser spot diameter of 100 mm can be achieved, which translates in high thicknesses of the consolidated layers. Furthermore, the lunar regolith simulant EAC-1A is used as a substitute of the actual lunar soil. At the end of the study, large samples (approximately 250 × 250 mm) with interlocking capabilities were fabricated by melting the lunar simulant with the laser directly on the powder bed. Large areas of lunar soil can be covered with these samples and serve as roads and landing pads, decreasing the propagation of lunar dust. These manufactured samples were analysed regarding their mineralogical composition, internal structure and mechanical properties.
Novel myopia control spectacle lenses induce peripheral contrast reduction via optical diffusion. It is suggested, that the contrast reduction alters retinal processes in the low-level neural circuity, leading to an inhibition of eye growth. The purpose of this thesis is to evaluate the influence of full-field contrast reduction on low-level neural processing of the retina, described by the edge contrast sensitivity.