Open Access
Refine
Year of publication
- 2015 (25) (remove)
Document Type
- Bachelor Thesis (19)
- Master's Thesis (6)
Has Fulltext
- yes (25)
Is part of the Bibliography
- no (25) (remove)
Keywords
- Studie (4)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Augenoptikgeschäft (1)
- Comparison metrics (1)
- Deflektometrie (1)
- EVA (1)
- Eye tracking (1)
- Fixation (1)
- Gleitsichtbrille (1)
- Gleitsichtgläser (1)
Institute
Das Ausmaß der Beeinträchtigung durch eine Schwerhörigkeit ist eng mit dem Verlust des Sprachverstehens verbunden.
Das oberste Ziel einer Hörsystemversorgung ist deshalb das Wiederherstellen der Kommunikationsfähigkeit.
Beim Nachweis des Versorgungsnutzens stellt die Sprachaudiometrie einen wesentlichen Bestandteil dar.
In dieser Bachelorarbeit geht es um den Vergleich von Oldenburger Satztest und Oldenburger Kindersatztest in der Sprachaudiometrie Erwachsener.
Im Fokus der Untersuchungen standen dabei die Dauer der Messdurchführungen, der damit verbundene Konzentrationsaufwand für den Kunden und die Höranstrengung. Ziel der Bachelorarbeit war es aufzuzeigen, dass der Oldenburger Kindersatztest eine geeignete sprachaudiometrische Methode zur Ermittlung der Sprachverständlichkeitsschwelle bei Erwachsenen darstellt, da er aufgrund seiner reduzierten Durchführungsdauer den Kunden weniger belastet und anstrengt.
Validierung des SNR mit Hilfe des OlSa in drei Lautstärken mit zwei verschiedenen Hörgeräteklassen
(2015)
Da Unterschiede zwischen Low-End- und High-End-Hörsystemen nicht mehr in Ruhe nachgewiesen werden können, wurde in dieser Studie der Unterschied zwischen den beiden Hörsystemen überprüft. In bisherigen Studien konnte nur
eine Verbesserung des SNR durch eine Richtmikrofonwirkung nachgewiesen werden.
Um die Vorteile der weiteren Features und der höheren Kanalanzahl bei den High-End-Hörsystemen nachzuweisen, wurden in dieser Studie das Störgeräusch und das Sprachsignalaus der gleichen Richtung angeboten. Den Probandinnen und Probanden wurden jeweils ein Low-End- und ein High-End-Hörsystem nach NAL-NL2 angepasst. Dabei wurden sie in drei verschiedene Schwerhörigkeitsgrade eingeteilt und mit dem Oldenburger Satztest der SNR bei drei verschiedenen Störgeräuschlautstärken bestimmt.
Verglichen wurden sowohl der Unterschied in den einzelnen Gruppen von Schwerhörigkeitsgraden als auch die Verbesserung im Gegensatz zum unversorgten SNR. Es besteht tendenziell ein Unterschied zwischen den beiden Hörsystemen. In nahezu allen Störgeräuschlautstärken und allen Schwerhörigkeitsgraden wurde eine Verbesserung des SNR mit den High-End-Hörsystemen erreicht.
Der Vorteil der High-End-Hörsysteme wird mit lauterem Störgeräusch größer, so dass die Schwerhörigen vor allem in lauten Situationen von den Hörsystemen profitieren können.
Die Verbesserung des SNR mit den Hörsystemen gegenüber keiner Versorgung liegt bei den mittel- und hochgradig Schwerhörigen weit über der von der HilfsM-RL geforderten 2 dB.
Der Vorteil der High-End-Hörsysteme muss noch in weiteren Studien untersucht werden um einen signifikanten Unterschied zwischen den beiden Hörsystemen nachzuweisen, der in dieser Studie schon tendenziell nachgewiesen werden konnte.
Im Rahmen der vorliegenden Bachelorarbeit wurden bei 41 Probanden sowohl objektive als
auch subjektive Refraktionsbestimmungen durchgeführt. Bei den Probanden wurde die
klassische monokulare Refraktionsbestimmung mit dem Kreuzzylinder durchgeführt. Im
Anschluss an diese Messung, wurde ein monokularer Feinabgleich unter binokularen
Bedingungen für Sphäre, Zylinder und Achse am Zyklofusionstest durchgeführt. Ziel ist es zu
prüfen, ob zum einen die monokulare Refraktion unter binokularen Bedingungen am
Zyklofusionstest ein gleichwertiges Verfahren zur Refraktionsbestimmung ist wie die
monokulare Refraktion und zum anderen ob sich unter binokularen Bedingungen eine andere
Zylinderachse ergibt wie unter monokularen. Zu Beginn der Arbeit werden zunächst die
Grundlage zum Zyklofusionstest und der Aufbau des Testes erläutert. Zusätzlich wird in den
Methoden die Durchführung der Messung erläutert. In der Auswertung der Ergebnisse wurde
besonders auf die Zylinderachse und -stärke geachtet. Hier ergaben sich zwischen den beiden
Messverfahren leicht unterschiedliche Refraktionen. Im ersten Messdurchgang ergab sich für
die Differenz im sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,43 dpt und
im zweiten Messdurchgang von ±0,29 dpt um die mittlere Refraktion. Die beiden Messmethoden
unterscheiden sich daher nicht relevant voneinander. In 72% der Fälle führten beide
Messmethoden zur gleichen Visusstufe. Beim wiederholten Durchführen der Messung wurde in
77% der Fälle die gleiche Visusstufe erreicht. Des Weiteren ergab sich für die beiden Verfahren
eine ähnliche Reproduzierbarkeit. Bei der binokularen Messung ergab sich für die Differenz im
sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,37 dpt und bei der
monokularen Messung von ±0,39 dpt um die mittlere Abweichung. Um die Handhabung und
die Anwendbarkeit interpretieren zu können wurden zum einen die Dauer der Messungen mit
einander verglichen und zum anderen die Probanden nach der Messung zu ihrer persönlichen
Meinung befragt. Für die Messung am Zyklofusionstest ergab sich eine Prüfdauer von ca. 10
Minuten. 56% der Probanden empfanden die Beurteilbarkeit während der monokularen
Refraktion am einfachsten und angenehmsten. Für 15% war die Beurteilung am Zyklofusionstest
einfacher und die restlichen 29% konnten keinen Unterschied in der Beurteilung
feststellen. Anschließend wird in der Diskussion auf Komplikationen während der Messung
anhand von Einzelfällen eingegangen und mögliche Fehlerquellen werden aufgezeigt.
Abschließend ist festzustellen, dass der Zyklofusionstest eine neue Messmethode ist, die im
Wesentlichen die gleichen Ergebnisse und eine gleich gute Reproduzierbarkeit wie die
klassische monokulare Refraktion aufweist und in Zukunft mit in den Refraktionsablauf
integriert werden kann.
Ziel dieser Arbeit ist es, das Zielgruppenmodell Roper Consumer Styles (RCS)
der Gesellschaft für Konsumforschung (GfK) genau zu beschreiben und dessen
Anwendbarkeit auf die Augenoptik zu prüfen.
Zu Beginn werden die Geschichte und Entwicklung der Roper Consumer Styles
(RCS) sowie das Modell selbst und seine einzelnen Lebensstile erläutert. Im
zweiten Teil setzt sich diese Arbeit mit der Anwendung der Roper Consumer
Styles (RCS) in der Augenoptik auseinander. Es wird ein Pilotprojekt vom
Zentralverband der Augenoptiker (ZVA) und der Gesellschaft für Konsumforschung
(GfK) vorgestellt. Die Gesellschaft für Konsumforschung (GfK) bestimmt
das Einzugsgebiet des Optikers, analysiert die Kundschaft in dem Gebiet und
zeigt auf, bei welchen Zielgruppen noch Potenzial besteht. Der Optiker bekommt
von der Gesellschaft für Konsumforschung (GfK) konkrete Empfehlungen,
welche Marken und welche Designs die gewünschten Zielgruppen ansprechen.
Es ergeben sich vier Bereiche, in denen die Roper Consumer Styles (RCS) in
der Augenoptik angewandt werden können: Produkt/Sortimentspolitik, Preispolitik,
Kommunikationspolitik und Ladenbau/Schaufenstergestaltung. Anschließend
wird das Projekt einer kritischen Würdigung unterzogen. Dabei werden zwei
Verbesserungsvorschläge vorgebracht. Ein Vorschlag ist, die Fassungen nicht
nach Marken, sondern nach den Styles zu unterscheiden und eine Klassifizierung
der Fassungen nach den Roper Consumer Styles (RCS) zu machen. Der
andere Vorschlag ist, ein Kurzfragebogen zu entwickeln, der eine direkte
Einordnung des einzelnen Kunden nach den Roper Consumer Styles (RCS)
ermöglicht. Abschließend wurde eine Umfrage unter den Betrieben, die am
Projekt teilgenommen haben, durchgeführt. Die Ergebnisse der Umfrage zeigen,
dass das Zielgruppenmodell Roper Consumer Styles (RCS) in der Augenoptik
Anwendung findet und von den Optikern selbst auch als positiv bewertet wird.
Aus diesem Grund soll die Analyse der Gesellschaft für Konsumforschung (GfK)
in Zukunft für einen größeren Kreis von Betrieben angeboten werden.
Zweck: Das Ziel dieser Studie ist es die Wahrnehmung und Akzeptanz von Unschärfe beim seitlichen Blick durch ein Gleitsichtglas zu untersuchen. Mit dem Blurtest sollte eine geeignete Methode zur Messung von Sehbereichsbreiten bei Gleitsichtgläsern entwickelt und verifiziert werden.
Material/Methoden: Die horizontalen Sehbereichsbreiten von vier Gleitsichtgläsern unterschiedlicher Progressionskanalbreite (2, 3, 4 und 5 mm) und linearem Wirkungsanstieg sollten bei einem Beobachtungsabstand von 40 cm für drei Unschärfekriterien gemessen werden. Die Grenzen für bemerkbare, tolerierbare und unakzeptable Unschärfe werden für einen am Bildschirm dargebotenen sinnfreien Text in Schriftgrad 9 pt (Visus = 0,4) links und rechts des monokularen Blickfelds markiert. Zusätzlich sollte in einem Vortest (Pretest) nach diesen Kriterien verschwommener, gedruckter Text beurteilt werden.
Ergebnisse: Die Grenzen für eben bemerkbare, tolerierbare und unakzeptable Unschärfe liegen bei einem Astigmatismus in Gebrauchsstellung von 0,70 ±0,3 dpt, 1,37 ±0,50 dpt und 2,06 ±0,74 dpt bei einem natürlichen Pupillendurchmesser von durchschnittlich 3,37 mm. In 40 % der Fälle unterscheiden sich die Grenzen für Unschärfe innerhalb eines Probanden nicht signifikant. Es besteht ein Zusammenhang zwischen der Toleranzbereitschaft unscharfe Texte in Alltagssituationen zu lesen und der Beurteilung von modifiziertem, gedrucktem Text.
Fazit: Die markierten Sehbereichsbreiten korrelieren mit dem horizontalen Anstieg des unerwünschten Astigmatismus, lassen sich bei Wiederholungsmessungen am Blurtest jedoch nicht auf ≤ 2° Schwankungsbreite reproduzierbar nachweisen. Die Definition, Wahrnehmung und Toleranz von Unschärfe in verschiedenen Alltagssituationen hängen von individuellen Erfahrungswerten und gesetzten Anspruch an Seh- bzw. Leseleistungen ab.
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).
Die Six Sigma-Methodik hilft Unternehmen als strategisches Marketing-Tool die Qualität der Produkte und Prozesse durch den Einsatz von statistischen Werkzeugen und fundierten Prozessoptimierungsmethoden zu verbessern, die Kunden zufriedener zu machen und die Abläufe im Unternehmen zu beschleunigen. Ziel der Arbeit ist es herauszufinden, ob sich dieses Qualitätsmanagement-Konzept auch auf die Gegebenheiten, Prozesse und Anforderungen in einem augenoptischen Betrieb wirksam anwenden lässt. In fünf klar definierten Projektphasen werden unter anderem durch die Erhebung, Analysierung und Auswertung von prozessbezogenen Daten Schwachstellen in betrieblichen Abläufen faktenbasiert offengelegt und fundiert verbessert. Ziel ist es, die Fehlerquote eines Prozesses auf ein Maß zu reduzieren, so dass von einer (annähernden) Null-Fehler-Qualität gesprochen werden kann. Die statistische Basis der Six Sigma-Methodik findet sich in der Tatsache begründet, dass alle betrieblichen Vorgänge einer Streuung vom statistischen Maß des „Soll-Wertes“ (Mittelwert μ) unterliegen, die sich durch eine Gauß’sche Normalverteilungskurve beschreiben lassen. Diese Streuungen (hier als Varianz oder Standardabweichung (σ) bezeichnet) sind als „Ist-Werte“ am Ende eines Prozesses zu verstehen. Um die Leistung eines Prozesses beurteilen zu können wird geprüft, wie oft die errechnete Standardabweichung zwischen den Zielwert und die Spezifikationsgrenzen passt. Die Anzahl stellt den Sigma-Wert des Prozesses dar. Die zentrale Aufgabe dieser Thesis ist es, darzulegen ob ─ und wenn ja ─ wie die Six Sigma-Methodik für kleine und mittlere Unternehmen im augenoptischen Fachbetrieb effektiv und sinnvoll zu implementieren ist. Die Recherchen und Analysen der Arbeit kommen diesbezüglich zu dem Ergebnis, dass Six Sigma durchaus eine Option für ein augenoptisches Unternehmen darstellen kann, das qualitative Niveau von Prozessen und Dienstleistungen zu heben. Jedoch bedarf es besonderer Sorgfalt bei der Auswahl geeigneter Prozesse und einer detaillierten Kosten-Nutzen-Aufstellung um mit Six Sigma effizient zu arbeiten und nachhaltigen Erfolg zu haben.
Ziel der Arbeit:
Die Verwendung von Kompression in Hörsystemen ist heutzutage essenzieller Bestandteil jeder
Hörsystemanpassung. In vielen Forschungsprojekten wurde bis heute Hauptsächlich das
Augenmerk auf die Hochtonkompression gelegt, dabei gibt es nur wenige Studien die sich mit
der Tieftonkompression beschäftigen. In dieser Studie wurde gezielt mit der Kompression im
niederfrequenten Bereich von 160 - 800 Hz gearbeitet mit der Besonderheit, dass zusätzlich
Grenzfrequenzen im Bereich von 160 - 480 Hz und 640 - 800 Hz gesetzt wurden. Das Augenmerk
wurde dabei auf die Frage gelegt, ob definierte Grenzfrequenzen die zu Frequenzbändern
zusammengefasst werden das Sprachverstehen beeinflussen können?
Material und Methode:
An dieser Studie nahmen sieben Schülerinnen und Schüler teil. Die Schülerinnen und Schüler
nahmen freiwillig an der Studie Teil und durften die Teilnahme jederzeit beenden. Die
Teilnehmerinnen und Teilnehmer bekamen Testgeräte die in zwei verschiedenen Einstellungen
im Tieftonbereich mit einem CV von 2,5:1 eingestellt wurden. Dabei war Einstellung 1 mit
den Grenzfrequenzen 160 - 480 Hz und Einstellung 2 mit den Grenzfrequenzen 640 - 800 Hz
eingestellt. Jede Einstellung wurde jeweils eine Woche testgetragen und dann gemeinsam ausgewertet.
Ergebnisse:
Das bessere Sprachverstehen (Validierung durch den OlKiSa) wurde mit Einstellung 1 erreicht,
auch bei der allgemeinen Bewertung des Hörsystems in Alltagssituationen wurde Einstellung 1
besser bewertet als Einstellung 2.
Schlussfolgerung:
Vorausgehende Studien konnten belegen, dass die Tieftonkompression für hochgradig schwerhörige
im Tieftonbereich einen positiven Einfluss auf das Sprachverstehen haben. Des weiteren
konnte mit der vorliegenden Studie eine Tendenz nachgewiesen werden, dass Grenzfrequenzen
im Tieftonbereich ebenso positive Effekte erzielen können. Die Ergebnisse zeigen die Tendenz
zu den tieferen Frequenzen 160 - 480 Hz der Einstellung 1. Die Allgemeine Zufriedenheit und
der Tragekomfort der Hörsystemene für Einstellung 1 war ausschlaggebender als die Ergebnisse
für Einstellung 2.
Diese Bachelorthesis beschreibt Gründungs- und Unternehmensführungsstrategie anhand einer handlungsorientierten und konstruktivistischen Lernstrategie VaKE (Value and Knowledge Education) zum Erlangen der beruflichen Handlungsfähigkeit. Dabei teilt sich die Arbeit in drei Hauptteile wie folgt auf: Im ersten Teil wird beschrieben welche Kompetenzen und Eigenschaften zusammen die berufliche Handlungsfähigkeit ergeben, und wie diese erworben werden kann. Weiterhin wird der geschichtliche Hintergrund von Qualifikationen und Handlungskompetenzen dargestellt. Im zweiten Teil dieser Bachelorthesis wird die Theorie zu den Gründungs- und Unternehmensführungsstrategien im Rahmen der allgemeinen Meisterprüfungsordnung (AMVO) herausgearbeitet und beschrieben. Dabei werden nach der AMVO im zweiten Handlungsfeld die Gründungs- und Übernahmeaktivitäten sowie das dritte Handlungsfeld der Unternehmensführungsstrategien genauer beschrieben. Das zweite Handlungsfeld gliedert sich in die Bedeutung der persönli-chen Voraussetzungen für den Erfolg der beruflichen Selbstständigkeit, die wirtschaftliche, gesellschaftliche und kulturelle Bedeutung des Augenoptiker Handwerks, der Nutzen von Handwerksorganisationen sowie Entscheidungen zum richtigen Standort eines Augenoptischen Betriebes. Das dritte Handlungsfeld beschreibt die Bestimmungen des Arbeits-und Sozialversicherungsrechts, Instrumen-te zur Durchsetzung von Forderungen sowie theoretischen Grundlagen zur Insolvenz und deren mögliche Konsequenzen. Der dritte Teil dieser Bachelorthesis setzt sich aus handlungsorientierten Aufgaben zu den Gründungs- und Unternehmensführungsstrategien zusammen, welche im zweiten Teil genau beschrieben wurden. Diese Aufgaben werden anhand der konstruktivistischen Lernstrategie VaKE durchgeführt.