Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (69)
- Article (28)
- Conference Proceeding (17)
- Master's Thesis (14)
- Report (3)
Keywords
- Abschlussarbeit (6)
- Bachelorarbeit A/H (4)
- Augenoptik (3)
- FrACT (2)
- Hörgerät (2)
- Landoltring (2)
- Leitfaden (2)
- Myopia (2)
- Myopieprogression (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- Studie (2)
- Studium (2)
- Visus (2)
- limbal sclera contour (2)
- vorderer Augenabschnitt (2)
- 3D-Druck (1)
- 3D-Refraktion (1)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Aalener Schnell Satztest (1)
- Ablaufplan (1)
- Absolventen (1)
- Absolventenbefragung (1)
- Atropin (1)
- Augenlänge (1)
- Augenoptik-Branche (1)
- Augenoptikgeschäft (1)
- Ausbildung (1)
- Bachelorarbeit A (1)
- Befragung (1)
- Brillenfassung, UV-Durchlässigkeit (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- Deflektometrie (1)
- Defocus (1)
- Dienstleistungsangebot (1)
- Diffusion (1)
- Digitalisierung (1)
- ETDRS (1)
- ETDRS-Tafeln (1)
- Edge Detection (1)
- Erblindung (1)
- Ethik (1)
- Eye tracking (1)
- Fixation (1)
- Geschäftsmodell (1)
- Gleitsichtbrille (1)
- Gleitsichtgläser (1)
- Grenzfrequenz (1)
- High-End-Hörsystem (1)
- Hörgerätverifikation (1)
- Hörqualität (1)
- Hörsystem (1)
- Hörsysteme (1)
- IOL Master 500 (1)
- Inter-Test Reliabilität (1)
- KI (1)
- Kameramessung (1)
- Kampimetrie (1)
- Kantendetektion (1)
- Kind (1)
- Kinder (1)
- Kommunikationstraining (1)
- Kontaktlinse (1)
- Kontaktlinsen (1)
- Kontaktlinsen-Service-System (1)
- Kontaktlinsensprechstunde (1)
- Kostenakzeptanz (1)
- Kreislaufwirtschaft (1)
- Kreuzzylinder (1)
- Kundengruppen (1)
- Lehrmethoden (1)
- Lernsoftware (1)
- Lernvideo, Verkaufsgespräch (1)
- Lernvideo, e-Learning, Leitfaden (1)
- Leuchtdichte Homogenität (1)
- Leuchtdichte, Radiospektrometer, Kalibrierung, Spiegelreflexkamera (1)
- Leuchtdichteverteilung (1)
- Lions Club (1)
- Low-End-Hörsystem (1)
- Marokko (1)
- Masterarbeit AO (1)
- Materialeigenschaften (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Messmethode (1)
- Messsystem (1)
- Messtechnik (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Myopiekontrolle (1)
- Myopiemanagement (1)
- Nachhaltigkeit (1)
- Ohrmodell (1)
- Omnichannel (1)
- Onlineportal (1)
- Optometrist (1)
- Optotypen (1)
- Orthokeratologie (1)
- Perimetrie (1)
- Primary Eye Care Provider (1)
- Psychophysik (1)
- RCS (1)
- Refraktionsbestimmung (1)
- Retest-Reliabilität (1)
- Risikoanalyse (1)
- SNR-Verhältnis (1)
- Satztest (1)
- Scanpath (1)
- Schule (1)
- Screening (1)
- Sehilfen (1)
- Sehschärfe (1)
- Six Sigma (1)
- Sphärisches Äquivalent (1)
- Sri Lanka (1)
- Strategie, Unternehmensführung, AMVO, VaKE (1)
- Streifenprojektion (1)
- Streifenprojektionsgerät (1)
- Studiengang Augenoptik (1)
- Störgeräusch (1)
- Technikfolgenabschätzung (1)
- Tieftonkompression (1)
- Tolerance of blur, PAL`s, Astigmatism, Blurtest, Pretest (1)
- Umfrage (1)
- Unschärfetoleranz , Gleitsichtgläser, Astigmatismus , Blurtest, Pretest (1)
- Unverträglichkeit (1)
- Unzufriedenheit (1)
- Versorgungskapazität (1)
- Visual search (1)
- Vorderkammertiefe (1)
- Weblog (1)
- Webportal (1)
- Webseite (1)
- Zufriedenheitsmessung (1)
- Zyklofusionstest (1)
- albinism (1)
- artificial consciousness (1)
- augenoptischer Betrieb (1)
- automatical telephone audiometry, hearing aid fitting (1)
- automatisierter Telefonhörtest, Hörgeräteanpassung (1)
- berufliche Perspektiven (1)
- blindness (1)
- care capacity (1)
- customized (1)
- erfolgreiches Geschäftsmodell, optometrische Dienstleistungen, Wettbewerb (1)
- genes (1)
- i.Profiler (1)
- internationale Schwerhörigenhilfe (1)
- learning videos, e-learning, guideline (1)
- low vision (1)
- luminance distribution (1)
- luminance homogeneity (1)
- luminance, radio spectrometer, calibration, reflex-camera (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- monokulare Refraktionsbestimmung (1)
- myopia management (1)
- optometric and optical companies (1)
- optometrische Dienstleistungen (1)
- peripheral myopic defocus (1)
- proaktive Ansprache (1)
- psychophysics (1)
- repeatability (1)
- soft multifocal contact lens (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- strategy, management, AMVO, VaKE (1)
- successful business-model, optometrical service, competition (1)
- sustainability (1)
- two-rod test (1)
- vision therapy (1)
- visual acuity (1)
Institute
- Optik und Mechatronik (131) (remove)
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.
Biometrie des Auges
(2020)
Das Ziel dieser Studie besteht darin, 200 Probanden an den Zeiss-Geräten i.Profiler und IOL Maser 500 zu vermessen, um ein individuelles Augenmodel überprüfen zu können.
Zusätzlich wird untersucht wie das Sphärische Äquivalent (SÄ) der Probanden, mit der jeweiligen Augenlänge und der Vorderkammertiefe korreliert. Die Messungen der zufällig ausgewählten Probanden erfolgten immer am rechten Auge zwischen 9:00 und 15:00 Uhr.
Pharmaceutical agents or drugs often have a pronounced impact on protein-protein interactions in cells, and in particular, cell membranes. Changes of molecular conformations as well as of intermolecular interactions may affect dipole-dipole interaction between chromophoric groups, which can be proven by measuring the Förster resonance energy transfer (FRET). If these chromophores are located within or in close proximity to the plasma membrane, they are excited preferentially by an evanescent electromagnetic wave upon total internal reflection (TIR) of an incident laser beam. For the TIR-FRET screening of larger cell collectives, we performed three separate steps: (1) setting up of a membrane associated test system for probing the interaction between the epidermal growth factor receptor (EGFR) and the growth factor receptor-bound protein 2; (2) use of the Epac-SH188 sensor for quantitative evaluation under the microscope; and (3) application of a TIR fluorescence reader to probe the interaction of GFP with Nile Red. In the first two steps, we measured FRET from cyan (CFP) to yellow fluorescent protein (YFP) by spectral analysis and fluorescence lifetime imaging (FLIM) upon illumination of whole cells (epi-illumination) as well as selective illumination of their plasma membranes by TIR. In particular, TIR excitation permitted FRET measurements with high sensitivity and low background. The Epac sensor showed a more rapid response to pharmaceutical agents, e.g., Forskolin or the A2B adenosine receptor agonist NECA, in close proximity to the plasma membrane compared to the cytosol. Finally, FRET from a membrane associated GFP to Nile Red was used to test a multi-well TIR fluorescence reader with simultaneous detection of a larger number of samples.
Preliminary study: Polishing force measurement by viscosity - the return of ketchup polishing
(2021)
Die im Rahmen dieser Bachelor Thesis "Verzeichnung und Brillenanpassung - Eine Visualisierung in Form von Drehbüchern" erarbeiteten Drehbücher dienen als Vorlage zur Erstellung von Lehrvideos in Form von Kurzfilmen mit einer Länge von drei bis vier Minuten.
Diese Kurzfilme sollen Kunden und Mitarbeitern der Firma Schneider das Verständnis für das jeweilige optische Thema erleichtern.
Es wurden Drehbücher zu den Themen "Anpassung und Zentrierung von Brillen" und "Verzeichnung und Schaukeleffekt bei Gleitsichtgläsern" erstellt.
Die angefertigten Drehbücher ermöglichen mit genauen Regieanweisungen und Layouts die spätere Umsetzung durch Dritte. Verschiedene Situationen und Darstellungen werden mit Skizzen und Anmerkungen vertieft. Die jeweiligen Bilder unterstützen die Veranschaulichung der einzelnen Szenen und erleichtern die Umsetzung vom Drehbuch zum Film. Zusätzlich gibt es in beiden Drehbüchern einen Text für den Sprecher.
Mit dieser Erzählstimme werden im Video die einzelnen Abbildungen und Szenen für den Betrachter leicht verständlich erklärt. Zudem wurde von beiden Drehbüchern ein Storyboard angefertigt, welches mit Kameraanweisungen und Szenenbeschreibungen den zeitlichen Ablauf des Videos darstellt.
Zusätzlich zu den Drehbüchern wurden die Grundlagen beider Themen in jeweils einem theoretischen Teil zusammenfassend erklärt.