Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (146)
- Article (25)
- Master's Thesis (21)
- Report (15)
- Conference Proceeding (12)
- Other (2)
- Doctoral Thesis (1)
Has Fulltext
- yes (222) (remove)
Keywords
- Augenoptik (12)
- virtual reality (9)
- Abschlussarbeit (7)
- Augenoptiker (7)
- Studie (6)
- Hörgerät (5)
- Bachelorarbeit A/H (4)
- Business Process Management Systems (4)
- Fuzzy Logic (4)
- Kontaktlinse (4)
Institute
- Optik und Mechatronik (84)
- Augenoptik und Hörakustik (43)
- Wirtschaftswissenschaften (30)
- Elektronik und Informatik (20)
- Internationale Betriebswirtschaft (18)
- Maschinenbau und Werkstofftechnik (13)
- Chemie (1)
- Informatik (1)
- Technischer Redakteur (1)
Die Streifenprojektion hat sich im Laufe der letzten Jahre schnell neben den Koordinatenmessgeräten in der 3D-Messtechnik etabliert und ist aus diesem Bereich nicht mehr wegzudenken. Auch auf anderen Gebieten, wie beispielsweise der Medizin oder der Automobilindustrie, findet diese im Alltag Anwendung. Ein entscheidender Vorteil der Streifenprojektion besteht darin, Objekte schnell und berührungslos zu vermessen.
In der vorliegenden Bachelorarbeit wird detailliert auf ein selbstentwickeltes Streifenprojektionsgerät eingegangen, dass mit geringen finanziellen Mitteln konstruiert wurde. Hierbei wurde die Software zur Steuerung der Komponenten sowie zur Auswertung der erfassten Daten in Matlab erstellt.
Das Gerät wurde auf Benutzerfreundlichkeit untersucht und hinsichtlich dieses Aspektes verbessert. Im Zuge dessen beinhaltet die Bachelorthesis eine ausführliche Benutzeranleitung für Neuanwender.
Durch Transformation der Kalibrierung in metrische Daten kann das Streifenprojektionsgerät für zukünftige Messungen benutzt werden.
Es konnten die Fragen geklärt werden, wie reproduzierbar die Ergebnisse des Messgerätes sind und welche Messgenauigkeit erzielt werden kann. Zusätzlich erfolgte die Definition des erreichbaren Messvolumens.
Die Auswertung der durchgeführten Messversuche zeigte, dass das Gerät reproduzierbare Ergebnisse liefert. Außerdem konnte gezeigt werden, dass das Streifenprojektionsgerät in der Lage ist einfache Freiformflächen zu vermessen. Die erzeugten Messdaten können beispielsweise als Solldaten für die Vermessung mit taktilen Messmaschinen verwendet werden. Oberflächen welche scharfe Kanten, also nicht stetige Strukturen, besitzen, können mit diesem Aufbau nicht vermessen werden
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
Purpose: The aim is to be able to advise patients on the choice of sports and exercises regarding the effects on the intraocular pressure.
Methods: The search engines Google Scholar and PubMed were used to search for suitable studies. The studies were summarized, and the most important data were collected in one table for each study. The effect on the IOP was extracted or, if not given in the article, calculated by the difference of means of the IOP after or during exercise, and the baseline IOP before, whenever these values were available.
Findings: A total of 47 studies out of the years 1990 to 2020 that investigated the influence on the IOP of the most popular sports actively practiced in Germany were reviewed and summarized: twelve for running, sixteen for fitness/ weight training, one for swimming/diving, twelve for cycling, four for hiking, and two for yoga.
Conclusions: Throughout all studies and sports it was seen that physical fitness stabilized the IOP. Higher
intensity of exercise led to higher fluctuations of the IOP. Moderate endurance training keeps the IOP fluctuations low and may lead to a lower baseline IOP if practiced on a regular base. Fitness and weight training lead to fluctuations of the IOP in a pronounced manner when performed at moderate and high intensity. Therefore, only a moderate training can be recommended if there is need to keep the IOP stable. Isometric exercise is not recommended as it provokes a rise of the IOP even when performed with light loads. The Valsalva Maneuver should always be avoided as it leads to additional fluctuations of the IOP. Also, the IOP behaved more stable during resistance training when higher fitness was present.
Soft magnetic Fe-Al alloys have been a subject of research in the past. However, they never saw the same reception in technical applications as the Fe-Si or Fe-Ni alloys, which is, to some extent, due to a low ductility level and difficulties in manufacturing. Additive manufacturing (AM) technology could be a way to avoid issues in conventional manufacturing and produce soft magnetic components from these alloys, as has already been shown with similarly brittle Fe-Si alloys. While AM has already been applied to certain Fe-Al alloys, no magnetic properties of AM Fe-Al alloys have been reported in the literature so far. Therefore, in this work, a Fe-12Al alloy was additively manufactured through laser powder bed fusion (L-PBF) and characterized regarding its microstructure and magnetic properties. A comparison was made with the materials produced by casting and rolling, prepared from melts with an identical chemical composition. In order to improve the magnetic properties, a heat treatment at a higher temperature (1300 °C) than typically applied for conventionally manufactured materials (850–1150 °C) is proposed for the AM material. The specially heat-treated AM material reached values (HC: 11.3 A/m; µmax: 13.1 × 103) that were close to the heat-treated cast material (HC: 12.4 A/m; µmax: 20.3 × 103). While the DC magnetic values of hot- and cold-rolled materials (HC: 3.2 to 4.1 A/m; µmax: 36.6 to 40.4 × 103) were not met, the AM material actually showed fewer losses than the rolled material under AC conditions. One explanation for this effect can be domain refinement effects. This study shows that it is possible to additively manufacture Fe-Al alloys with good soft magnetic behavior. With optimized manufacturing and post-processing, further improvements of the magnetic properties of AM L-PBF Fe-12Al may still be possible.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.
Ziel der Arbeit:
Die Verwendung von Kompression in Hörsystemen ist heutzutage essenzieller Bestandteil jeder
Hörsystemanpassung. In vielen Forschungsprojekten wurde bis heute Hauptsächlich das
Augenmerk auf die Hochtonkompression gelegt, dabei gibt es nur wenige Studien die sich mit
der Tieftonkompression beschäftigen. In dieser Studie wurde gezielt mit der Kompression im
niederfrequenten Bereich von 160 - 800 Hz gearbeitet mit der Besonderheit, dass zusätzlich
Grenzfrequenzen im Bereich von 160 - 480 Hz und 640 - 800 Hz gesetzt wurden. Das Augenmerk
wurde dabei auf die Frage gelegt, ob definierte Grenzfrequenzen die zu Frequenzbändern
zusammengefasst werden das Sprachverstehen beeinflussen können?
Material und Methode:
An dieser Studie nahmen sieben Schülerinnen und Schüler teil. Die Schülerinnen und Schüler
nahmen freiwillig an der Studie Teil und durften die Teilnahme jederzeit beenden. Die
Teilnehmerinnen und Teilnehmer bekamen Testgeräte die in zwei verschiedenen Einstellungen
im Tieftonbereich mit einem CV von 2,5:1 eingestellt wurden. Dabei war Einstellung 1 mit
den Grenzfrequenzen 160 - 480 Hz und Einstellung 2 mit den Grenzfrequenzen 640 - 800 Hz
eingestellt. Jede Einstellung wurde jeweils eine Woche testgetragen und dann gemeinsam ausgewertet.
Ergebnisse:
Das bessere Sprachverstehen (Validierung durch den OlKiSa) wurde mit Einstellung 1 erreicht,
auch bei der allgemeinen Bewertung des Hörsystems in Alltagssituationen wurde Einstellung 1
besser bewertet als Einstellung 2.
Schlussfolgerung:
Vorausgehende Studien konnten belegen, dass die Tieftonkompression für hochgradig schwerhörige
im Tieftonbereich einen positiven Einfluss auf das Sprachverstehen haben. Des weiteren
konnte mit der vorliegenden Studie eine Tendenz nachgewiesen werden, dass Grenzfrequenzen
im Tieftonbereich ebenso positive Effekte erzielen können. Die Ergebnisse zeigen die Tendenz
zu den tieferen Frequenzen 160 - 480 Hz der Einstellung 1. Die Allgemeine Zufriedenheit und
der Tragekomfort der Hörsystemene für Einstellung 1 war ausschlaggebender als die Ergebnisse
für Einstellung 2.
Identification and quantitative segmentation of individual blood vessels in mice visualized with preclinical imaging techniques is a tedious, manual or semiautomated task that can require weeks of reviewing hundreds of levels of individual data sets. Preclinical imaging, such as micro-magnetic resonance imaging (μMRI) can produce tomographic datasets of murine vasculature across length scales and organs, which is of outmost importance to study tumor progression, angiogenesis, or vascular risk factors for diseases such as Alzheimer’s. Training a neural network capable of accurate segmentation results requires a sufficiently large amount of labelled data, which takes a long time to compile. Recently, several reasonably automated approaches have emerged in the preclinical context but still require significant manual input and are less accurate than the deep learning approach presented in this paper—quantified by the Dice score. In this work, the implementation of a shallow, three-dimensional U-Net architecture for the segmentation of vessels in murine brains is presented, which is (1) open-source, (2) can be achieved with a small dataset (in this work only 8 μMRI imaging stacks of mouse brains were available), and (3) requires only a small subset of labelled training data. The presented model is evaluated together with two post-processing methodologies using a cross-validation, which results in an average Dice score of 61.34% in its best setup. The results show, that the methodology is able to detect blood vessels faster and more reliably compared to state-of-the-art vesselness filters with an average Dice score of 43.88% for the used dataset.
Demographische Veränderungen durch eine zunehmende Alterung der Gesellschaft und eine Zunahme an Erkrankungen wie der AMD, des Glaukoms und der diabetischen Retinopathie stellen ophthalmologische Versorgungs- und Vorsorgemaßnahmen in Deutschland vor immer größere Herausforderungen. Einen wesentlichen Beitrag zur Sicherung der Vorsorgemaßnahmen können in der Zukunft Optometristen leisten. Mit Hilfe modernster Technologien, wie dem Ultra-Widefield-cSLO (Optos Daytona, können auch bei kleinen Pupillendurchmessern 200° Aufnahmen vom Augenhintergrund erstellt werden.