Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.