Open Access
Refine
Year of publication
Document Type
- Article (24)
- Bachelor Thesis (12)
- Master's Thesis (12)
- Conference Proceeding (11)
- Doctoral Thesis (1)
Language
- English (60) (remove)
Has Fulltext
- yes (60) (remove)
Keywords
- virtual reality (9)
- Business Process Management Systems (4)
- Fuzzy Logic (4)
- visualization (4)
- Myopia (3)
- Assignment Automation (2)
- Augmented Reality (2)
- Business Process Modeling Notation (2)
- Git (2)
- Studie (2)
Institute
Strategy development is one of the crucial factors for a firm's performance. For it
to be developed, a strategic analysis has to be conducted first. It enables
companies to gain a deeper understanding of their internal and external
environment. In the present work, the specialty coffee market is closely analyzed through a strategic analysis. The focus of this study is the young company Tikuna, a coffee producer that aims to enter the German market. In this context, Tikuna's possible entry into the German market and the companies competitive capacities are analyzed. In order to implement the different tools of the analysis, extensive literature research, as well as one expert interview and a survey were conducted.
It was found that Tikuna possesses all characteristics to enter the German
market. However, due to the lack of a differentiation factor in Tikuna's value
proposition, its competitive capacity is limited to a short period of time. In this
sense, different recommendations are given in order to ensure long term success
in the market. The central one being that Tikuna has to use its main strength and
bring innovation to the market.
Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Aim Patrick J. Caroline and Mark P. Andre first reported about soft lens orthokeratology in 2005. In a number of articles in the past five years, they reported about their research on this topic and their new findings. The aim of this study was to continue the research of Patrick J. Caroline and Mark P. Andre and to collect more information about the outcome of the technique. Methods Ten subjects with low myopia from -0.25 D to -1.25 D and a refractive astigmatism from plano to -0.75 D were fitted with a -10.00 D CIBA VISION AIR OPTIX® NIGHT&DAY® silicone hydrogel contact lens and were told to wear the lenses over night and everted. Corneal topography and refraction measurements were taken after one night, one week and one month of contact lens wear. Results Eight out of ten subjects finished the study, six female and two male. The mean age of the subjects was 23.9 years. With the eight subjects who finished the study, the mean change in subjective refraction was about +1.00 D in the sphere and +0.22 D in the cylinder, with maximum changes of +1.75 D sphere and +0.75 D cylinder. The mean apical power change, measured with the topographer, was 1.11 D. Changes in K - readings ranged from slight corneal steepening in both of the meridians to 0.23 mm of corneal flattening in the horizontal meridian and 0.27 mm of corneal flattening in the vertical meridian. Corneal eccentricity decreased about 0.65 on average. The main complaints and problems were the high minus power and the decentration of the contact lens and the occurrence of ghosting at night. Conclusion The results of this study show that everted wear of a high minus silicone hydrogel contact lens can lead to orthokeratology - such as changes in corneal topography and subjective refraction. These changes range from plano to +1.75 D sphere and +0.25 D to +0.75 D cylinder but are unpredictable and vary from subject to subject. Additional studies regarding the contact lens decentration and the unpredictability of the outcome need to be done to optimize the process.
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Based on a data-driven approach, a computer-assisted workflow for the quantitative analysis of optical Kerr microscopy images of sintered FeNdB-type permanent magnets was developed. By analyzing the domain patterns visible in the Kerr image with data-driven approaches such as traditional machine learning and advanced deep learning, we can quantify grain orientation and size with a better trade-off between accuracy and higher throughput than electron backscatter diffraction (EBSD). The key distinction between traditional machine learning and advanced deep learning lies in feature extraction. Traditional methods require manual, user-dependent feature extraction from input data, while advanced deep learning achieves this automatically. The predictions from the trained models were compared to the measurements from EBSD for performance evaluation. The proposed data-driven model is trained on the dataset created from the correlative microscopy technique, which requires the images of grains extracted from the Kerr microscopy and corresponding EBSD grain orientation data (Euler angles). The fine-tuned deep learning model shows better generalization ability than the traditional machine learning models trained on the manually extracted features and resulted in a mean absolute error of less than 5° for grain orientation of the anisotropic magnet samples when evaluated against the measured EBSD values. The developed approach has reduced the measurement effort for grain orientation by 5 times and have sufficient accuracy when compared to the EBSD.
In this study, we investigate the use of artificial neural networks as a potentially efficient method to determine the rate capability of electrodes for lithium-ion batteries with different porosities. The performance of a lithium-ion battery is, to a large extent, determined by the microstructure (i.e., layer thickness and porosity) of its electrodes. Tailoring the microstructure to a specific application is a crucial process in battery development. However, unravelling the complex correlations between microstructure and rate performance using either experiments or simulations is time-consuming and costly. Our approach provides a swift method for predicting the rate capability of battery electrodes by using machine learning on microstructural images of electrode cross-sections. We train multiple models in order to predict the specific capacity based on the batteries’ microstructure and investigate the decisive parts of the microstructure through the use of explainable artificial intelligence (XAI) methods. Our study shows that even comparably small neural network architectures are capable of providing state-of-the-art prediction results. In addition to this, our XAI studies demonstrate that the models are using understandable human features while ignoring present artefacts.
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.
Laser melting manufacturing of large elements of lunar regolith simulant for paving on the Moon
(2023)
The next steps for the expansion of the human presence in the solar system will be taken on the Moon. However, due to the low lunar gravity, the suspended dust generated when lunar rovers move across the lunar soil is a significant risk for lunar missions as it can affect the systems of the exploration vehicles. One solution to mitigate this problem is the construction of roads and landing pads on the Moon. In addition, to increase the sustainability of future lunar missions, in-situ resource utilization (ISRU) techniques must be developed. In this paper, the use of concentrated light for paving on the Moon by melting the lunar regolith is investigated. As a substitute of the concentrated sunlight, a high-power CO2 laser is used in the experiments. With this set-up, a maximum laser spot diameter of 100 mm can be achieved, which translates in high thicknesses of the consolidated layers. Furthermore, the lunar regolith simulant EAC-1A is used as a substitute of the actual lunar soil. At the end of the study, large samples (approximately 250 × 250 mm) with interlocking capabilities were fabricated by melting the lunar simulant with the laser directly on the powder bed. Large areas of lunar soil can be covered with these samples and serve as roads and landing pads, decreasing the propagation of lunar dust. These manufactured samples were analysed regarding their mineralogical composition, internal structure and mechanical properties.
Future lunar exploration will be based on in-situ resource utilization (ISRU) techniques. The most abundant raw material on the Moon is lunar regolith, which, however, is very scarce on Earth, making the study of simulants a necessity. The objective of this study is to characterize and investigate the sintering behavior of EAC-1A lunar regolith simulant. The characterization of the simulant included the determination of the phase assemblage, characteristic temperatures determination and water content analysis. The results are discussed in the context of sintering experiments of EAC-1A simulant, which showed that the material can be sintered to a relative density close to 90%, but only within a very narrow range of temperatures (20–30 °C). Sintering experiments were performed for sieved and unsieved, as well as for dried and non-dried specimens of EAC-1A. In addition, an analysis of the densification and mechanical properties of the sintered specimens was done. The sintering experiments at different temperatures showed that the finest fraction of sieved simulant can reach a higher maximum sintering temperature, and consequently a higher densification and biaxial strength. The non-dried powder exhibited higher densification and biaxial strength after sintering compared to the dried specimen. This difference was explained with a higher green density of the non-dried powder during pressing, rather than due to an actual influence on the sintering mechanism. Nevertheless, drying the powder prior to sintering is important to avoid the overestimation of the strength of specimens to be fabricated on the Moon.
Industry 4.0 production comprises complicated highly automated processes. However, human activities are also a crucial component of these processes, e.g., for machine main- tenance. Task assignment of human resources in this domain is challenging, as many factors have to be taken into account to ensure effective and efficient activity execution and satisfy special conditions (like worker safety). To overcome the limita- tions of current Business Process Management (BPM) Systems regarding activity resource assignment, this contribution provides a BPM-integrated approach that applies fuzzy sets for activity assignment. Our findings suggest that this approach can be easily applied to complex production scenarios, while providing efficient performance even with a large number of concurrent activity assignment requests. Additionally, our evaluation shows its potential for improved work distribution which can lead to cost savings in Industry 4.0 production processes.
Today’s Industry 4.0 Smart Factories involve complicated and highly automated processes. Nevertheless, certain crucial activities such as machine maintenance remain that require human involvement. For such activities, many factors have to be taken into account, like worker safety or worker qualification. This adds to the complexity of selection and assignment of optimal human resources to the processes and overall coordination. Contemporary Business Process Management (BPM) Systems only provide limited facilities regarding activity resource assignment. To overcome these, this contribution pro- poses a BPM-integrated approach that applies fuzzy sets and rule processing for activity assignment. Our findings suggest that our approach has the potential for improved work distribution and cost savings for Industry 4.0 production processes. Furthermore, the scalability of the approach provides efficient performance even with a large number of concurrent activity assignment requests and can be applied to complex production scenarios with minimal effort.
Leveraging Augmented Reality to Support Context-Aware Tasks in Alignment with Business Processes
(2021)
The seamless inclusion of Augmented Reality (AR) with Business Process Management Systems (BPMSs) for Smart Factory and Industry 4.0 processes remains a challenge. Towards this end, this paper contributes an approach integrating context-aware AR into intelligent business processes to support and guide manufacturing personnel tasks and enable live task assignment optimization and support task execution quality. Our realization extends two BPMSs (Camunda and AristaFlow) and various AR devices. Various AR capabilities are demonstrated via a simulated industrial case study.
Production processes in Industry 4.0 settings are usually highly automated. However, many complicated tasks, such as machine maintenance, must be executed by human workers. In current smart factories, such tasks can be supported by Augmented Reality (AR) devices. These AR tasks rely on high numbers of contextual factors like live data from machines or work safety conditions and are mostly not well integrated into the global production process. This can lead to various problems like suboptimal task assignment, over-exposure of workers to hazards like noise or heat, or delays in the production process. Current Business Process Management (BPM) Systems (BPMS) are not capable of readily taking such factors into account. There- fore, this contribution proposes a novel approach for context- integrated modeling and execution of processes with AR tasks. Our practical evaluations show that our AR Process Framework can be easily integrated with prevalent BPMS. Furthermore, we have created a comprehensive simulation scenario and our findings suggest that the application of this system can lead to various benefits, like better quality of AR task execution and cost savings regarding the overall Industry 4.0 processes.
Although production processes in Industry 4.0 set- tings are highly automated, many complicated tasks, such as machine maintenance, continue to be executed by human workers. While smart factories can provide these workers with some digitalization support via Augmented Reality (AR) devices, these AR tasks depend on many contextual factors, such as live data feeds from machines in view, or current work safety conditions. Although currently feasible, these localized contextual factors are mostly not well-integrated into the global production process, which can result in various problems such as suboptimal task assignment, over-exposure of workers to hazards such as noise or heat, or delays in the production process. Current Business Process Management (BPM) Systems (BPMS) were not particularly designed to consider and integrate context-aware factors during planning and execution. This paper describes the AR-Process Framework (ARPF) for extending a BPMS to support context-integrated modeling and execution of processes with AR tasks in industrial use cases. Our realization shows how the ARPF can be easily integrated with prevalent BPMS. Our evaluation findings from a simulation scenario indicate that ARPF can improve Industry 4.0 processes with regard to AR task execution quality and cost savings.
Ophthalmic lenses are ideally measured in accordance with the center of rotation of the eye. Therefore a measuring device was constructed due to this principle to measure lenses with a focimeter. In this work that measuring device was validated. Lenses of ± 4 dpt in spherical and aspherical design were measured across a field of 9x9 measuring points being at 5° distance from each other. This corresponds to a field of view of 40°. The measurement points in x- and y- direction were theoretically calculated to validate the measurement results. Regarding angles of incidence up to 20° it was supposed that the main optical aberration depends on a change in the sagittal and tangential sphere powers which is also defined as astigmatism. Therefore the calculation presents the tangential and sagittal oblique sphere powers depending on the different angles of the line of vision. On average the measurement results and the calculated data of the spherical designed lenses coincide quite good (correlation at 0,98), the systematic deviation of both values on average is 0.01 dpt and the random error (standard deviation) amounts 0.03 dpt on average. The minimum deviation is -0.06 dpt and the maximum is 0.09 dpt. Common focimeters have a measuring inaccuracy of up to 0.06 dpt (Diepes, Blendowske 2002). Therefore the quality of the measured data should be reliable. The aspherical designed lenses were compared to the spherical designed lenses. With increased angles of incidence the astigmatism of the aspherical lenses leads to lower values than the astigmatism of the spherical lenses
This paper deals with the question of which factors have to be given for
successful share repurchases that create long-term shareholder value. Center of
the thesis is the agency theory and its influence on share repurchases. Based on
theoretical findings success factors for share repurchases are derived and then
verified by case studies.
The main drivers for a successful share repurchase elaborated by this paper are a
suitable long-term executive compensation, an independent board of directors and
a shareholder structure without a majority shareholder. Additionally the findings
show that tying repurchases to certain share price thresholds improves the quality
of share repurchases.