Open Access
Refine
Year of publication
Document Type
- Article (156)
- Bachelor Thesis (146)
- Conference Proceeding (104)
- Report (31)
- Master's Thesis (22)
- Doctoral Thesis (11)
- Other (3)
- Patent (1)
Keywords
- Augenoptik (12)
- virtual reality (9)
- Abschlussarbeit (7)
- Augenoptiker (7)
- Studie (6)
- Hörgerät (5)
- Bachelorarbeit A/H (4)
- Business Process Management Systems (4)
- Fuzzy Logic (4)
- Kontaktlinse (4)
Institute
- Optik und Mechatronik (131)
- Wirtschaftswissenschaften (122)
- Maschinenbau und Werkstofftechnik (81)
- Augenoptik und Hörakustik (43)
- Elektronik und Informatik (42)
- Internationale Betriebswirtschaft (18)
- Chemie (12)
- Maschinenbau/Fertigungstechnik (2)
- Informatik (1)
- Mechatronik (1)
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).
This research looks into the question of where and how Artificial Intelligence and Big Data can be usefully implemented into Affiliate Marketing. By consulting relevant literature and qualified experts, this work identifies 6 areas, where Artificial Intelligence can be beneficial. These areas were found to be Affiliate Recruitment, Affiliate Management, Product Data Feed Optimization, Tracking, Attribution and Forecasting.
The implementation of Artificial Intelligence in these areas revealed 3 advantages to the Affiliate Marketing channel: Saving of time, support of decision-making, and incentivizing of publishers. While a more detailed study of this research topic would be necessary for validating the results, the findings show that the implementation of Artificial Intelligence technology can help a business gain competitive advantage.
Nachdem das Forschungsgebiet der Selbsteinschätzung von Hörqualität bei Kindern und Jugendlichen im schulischen Alltag bislang kaum betrachtet wurde, setzt diese Studienarbeit
an dieser Stelle an.
Im Rahmen der Studie sollte bewiesen werden, dass es keine Unterschiede in der Hörqualität durch Selbsteinschätzung wie auch in der Hörqualität durch Fremdeinschätzung zwischen Cochleaimplantat- und Hörgeräteträgern gibt. Zudem sollte ermittelt werden, wie hoch die Hörqualität der einzelnen Versorgungsgruppen in Selbst- und Fremdeinschätzung ist.
Alle Daten wurden aus einer Gruppe von 21 Cochleaimplantatträgern (m = 9; w = 12) und einer Gruppe von 50 Hörgeräteträgern (m = 28; w = 22) erhoben. Die mittlere Altersgruppe der Cochleaimplantatträger lag bei „13 - 15 Jahren“, die der Hörgeräteträger „10 - 12 Jahren“. Im Durchschnitt waren alle Kinder seit mehr als 3 Jahren bilateral mit Hörsystemen versorgt.
Getestet wurde mittels neu entwickelten Fragebögen, bewertet anhand eines speziell dafür ausgelegten Punktesystems.
Die Hörqualität der Selbsteinschätzung konnte für beide Versorgungsgruppen mit „sehr gut“ bewertet werden. Die Ergebnisse der Hörqualität für die Fremdeinschätzung war für beide
Gruppen etwas schlechter und wurde als „gut“ eingestuft. Der größte Unterschied bestand in der Hörqualität der Selbst- und Fremdeinschätzung zusammen. Hier konnten die Cochleaimplantatträger eine „gute“, die Hörgeräteträger jedoch eine „sehr gute“ Hörqualität erreichen.
Kinder und Jugendliche mit Cochleaimplantaten schätzen ihre Hörfähigkeit in allen Bereichen der Hörqualität, sowohl in ihrer Selbst- als auch in ihrer Fremdeinschätzung schlechter ein, als
die Kinder und Jugendlichen mit Hörgeräten.
Im Rahmen dieser Bachelorarbeit „Erstellung eines Webportals zur Einführung in die beruflichen Chancen und Möglichkeiten nach dem Augenoptik/Augenoptik- und Hörakustikstudium (B.Sc.)“ wird eine Webseite entwickelt, die die Studierenden und Bewerber im Studiengang Augenoptik/Augenoptik und Hörakustik an der Hochschule Aalen darüber informieren soll, welche beruflichen Perspektiven sich nach einem erfolgreichen Studium für sie ergeben könnten.
Um dies erreichen zu können, werden die zur Generierung der Webseite notwendigen Installationen vorgenommen. Hier wird zunächst auf die Entwicklungsumgebung und anschließend auf die Skriptsprache auf der die Webseite basiert eingegangen. Weiterhin wird das Datenbanksystem auf welches die Webseite zugreift um Inhalte bei Bedarf anzeigen zu können erläutert. Danach wird das zur Erzeugung der Webseite verwendete Programm WordPress und die Vorgehensweise bei der Absolventenbefragung vorgestellt.
Die Absolventen sollen hierbei nach der Kontaktaufnahme dem Verfasser Tätigkeitsbeschreibungen und ggf. Besonderheiten beim jeweiligen Bewerbungsverfahren zukommen lassen. Diese aus der Berufspraxis erhaltenen Berichte, werden anschließend zur Informationsbereitstellung anonymisiert in die Webseite integriert.
Nun wird in einem Vergleich festgestellt, dass andere Hochschulen in Deutsch-land in ihren Bachelorstudiengängen der Augenoptik/Optometrie und Hörakustik bisher kein zusätzlich entwickeltes Webseitenangebot mit Absolventenberichten bereitstellen.
Des Weiteren erfolgt eine Analyse eines Orientierungstests zur Studienorientierung und– Bewerbung. Hierbei wird erläutert, welche Vor- und Nachteile dieses Verfahren für Bewerber und Interessenten aufweist und welche Rolle das erarbeitete Konzept der vorliegenden Arbeit dabei spielt.
The surface topography of biodegradable polymer foils is modified by mechanical imprinting on a submillimeter length scale. The created patterns strongly influence the wetting behavior and allow the preparation of hydrophobic surfaces with controlled solid-liquid interaction. A detailed analysis of anisotropic surface patterns reveals that the observed effect arises from a combination of topographical and compositional changes that are introduced to the surface. As a main result it is found that an individual combination of material and structure is required for the production of water-repellent biopolymer foils that are highly attractive for packaging applications.
Die vorliegende Querschnittsstudie befasst sich mit dem komplexen Thema der „Inklusion“. Dabei ist das Ziel, dass behinderte Menschen gleichberechtigt an der Gesellschaft teilhaben, ohne Diskriminierung oder Ausgrenzung. Sie sollen die gleichen Bildungschancen erhalten wie nicht behinderte Menschen. In dieser Arbeit wurden die Einschätzungen von Eltern hörgeschädigter Kinder im Grundschulalter bezogen auf das Thema Inklusion ausgewertet. Material und Methode: Der erstellte Fragebogen, besteht aus 4 Abschnitten und 39 Fragen. Die Einschätzungen von 49 Müttern und 40 Vätern hörgeschädigter Kinder wurden ausgewertet. Zur Auswertung der Fragen wurden die besuchten Schulformen und die Sichtweisen von Müttern und Vätern herangezogen. Ergebnisse: Als Ergebnis der Studie war festzustellen, dass Inklusion noch nicht zufriedenstellend umgesetzt wurde. Es besuchen weiterhin mehr Schüler eine sonder-pädagogische Schule als eine allgemeine Schule. Außerdem ist die Form der Einzelintegration in den allgemeinen Schulen stark vertreten. Im Befinden der Schüler waren keine gravierenden Unterschiede zwischen den Schulformen festzustellen. Die meisten Kinder der Befragten besuchen die Schule gern. Dennoch zeigten die Ergebnisse, dass die Schüler der allgemeinen Schule nach einem Schultag tendenziell erschöpfter sind, als die der sonderpädagogischen Schulen. Die Einschätzungen der Eltern zu ihrem eigenen Wohlbefinden ließen erkennen, dass die Eltern allgemein beschulter Kinder belasteter sind. Diskussion: Ursachen für die Ergebnisse können eine unzureichende Beratung der Betroffenen sein oder die noch zu geringen Erfahrungen der allgemein bildenden Schulen im Umgang mit hörgeschädigten Kindern. Nicht ausreichend umgesetzte Rahmenbedingungen und die Problematik der bundesweit unterschiedlichen Schulgesetze können ebenfalls für die schleppende Umsetzung von Inklusion verantwortlich sein. Schlussfolgerungen: Für die Umsetzung von Inklusion ist die Zusammenarbeit verschiedener Institutionen von großer Bedeutung. Gerade das Wissen Betroffener und derjenigen, die erfolgreich hörgeschädigte Kinder erziehen und unterrichten, sollte Berücksichtigung finden. Bis ein Umdenken flächendeckend stattgefunden hat, ist noch viel Aufklärungsarbeit zu leisten. Dennoch scheint der Wunsch nach gleichberechtigter Teilhabe präsent und umsetzbar zu sein.
Analysen und Überlegungen zum elektronisch gestützten Brillenglasberatungsprozess in der Augenoptik
(2012)
Die augenoptische Beratung gewinnt in der heutigen Zeit immer mehr an Bedeutung. Es handelt sich dabei nicht um den Kauf eines bestimmten Produktes, sondern vielmehr um eine Dienstleistung. Der Brillenkauf soll zum Kauferlebnis werden. Um dies umzusetzen abreitet die deutsche Brillenglasindustrie seit den letzten Jahren zunehmend daran, Augenoptikern die Möglichkeit zu geben ihren Kunden komplexe Sachverhalte möglichst leicht verständlich erklären zu können. Sie möchten dem Endverbraucher das Thema Augen und Sehen erlebbar machen. Ziel dieser Bachelorthesis ist es die Besonderheiten der Kundenberatung allgemein vorzustellen und diese gezielt auf die Augenoptik näher zu erläutern. Dabei soll die Individualität des Kunden und so-mit jeder einzelnen Beratung in den Vordergrund gestellt werden. Um diesen Beratungsprozess für die Endverbraucher zum Erlebnis werden zu lassen, ist der Augenoptiker auf Mithilfe der Industrie angewiesen. Deren Produktportfolio erweitert sich stetig und auch einzelne Produkte selbst werden in ihrer Anwendung immer spezieller, so dass es für den Augenoptiker bald unmöglich wird alle Produkte zu kennen. Vor diesem Hintergrund wurden verschiedene Programme zur Unterstützung der Brillenglasberatung entwickelt. Die nachfolgende Arbeit soll den bisherigen Entwicklungsstand und zukünftige Potenziale hinsichtlich der Kundenbindung beim Augenoptiker und der Kundenneugewinnung aus Sicht der Industrie auf-zeigen. Im Laufe der Ausarbeitung hat sich gezeigt, dass die Entwicklungen der Industrie und die Erwartungen der Augenoptiker nicht deckungsgleich sind. Defizite werden abschließend näher analysiert und dienen somit zu Neu- und Weiterentwicklungsansätzen für die deutsche Brillenglasindustrie.
Learning for E-Learning
(2020)
Die Bachelorarbeit widmet sich der Entwicklung eines automatisierten Telefonhörtests und dessen Nutzen in der Praxis der Akustikerin/ des Akustikers.
Eine kostenfreie, freiverfügbare Telefonleitung wird eingerichtet und der Nutzen sowie die Qualität des
Hörtests werden mithilfe einer Studie analysiert. Der Telefonhörtest entsteht in Kooperation mit der Hochschule Aalen für Technik und Wirtschaft und dem Frauenhofer-Institut Oldenburg
für digitale Medientechnologie. Für die Entwicklung des Telefonhörtests sind theoretische und praktische
Vorüberlegungen zu der Umsetzung notwendig. Im ersten Teil der Arbeit wird auf das Telefon und seine Funktionsweise sowie seine Bedeutung in der Gesellschaft eingegangen. Ein wichtiger Aspekt ist hierbei die Übertragungsbreite des Telefons. Interessant ist auch die Erkenntnis des unveränderten Trends der Freizeitbeschäftigung der Deutschen. Im weiteren Verlauf werden die Anforderungen und die Umsetzung des Telefonhörtest geklärt. Der Test muss jederzeit frei verfügbar und kostenlos zu nutzen sein. Darüber hinaus sollte er leicht zu bedienen sein und nur wenig Zeit in Anspruch nehmen. Die Aufnahmen müssen zwingend gut verständlich, wiederholbar und bei jedem Anruf in gleicher Lautstärke wiedergegeben werden. Das
Tonbearbeitungsprogramm Audacity 1.3 Beta wird zur Aufnahme und Bearbeitung der Klangbeispiele verwendet. Die Datengröße der Aufnahmen werden für den Telefonserver minimiert und anschließend mit Audacity 1.3 Beta bearbeitet. Für die Validierung des Telefonhörtests wird mithilfe von Fragebögen eine Studie mit fünf Hörakustikbetrieben durchgeführt. Die zentralen Ergebnisse der durchgeführten Studie sind, dass 97 % der Hörgerätekunden und 81 % der Hörakustiker und Hörakustikerinnen ein Nutzen des Telefonhörtest sehen. 93 % der Befragten Akustiker und Akustikerinnen würden den Telefonhörtest in Zukunft anwenden oder bei passenden Fällen zur Unterstützung bei einer Hörgeräteanpassung nutzen. Der entwickelte Telefonhörtest zeigt, dass es möglich ist die gestellten Anforderungen umzusetzen. Die Verständlichkeit der Klangbeispiele werden von 88 % der Studienteilnehmer mit gut bis sehr gut bewertet und ist somit erfüllt. Da es sich um einen automatisierten Telefonhörtest handelt, ist auch die Wiederholbarkeit in gleichbleibender Lautstärke gegeben.
Motivation dieser Bachelorthesis war die Weiterführung eines Projekts im Rahmen eines Wahlpflichtmoduls zwei Semester zuvor, bei dem mittels des Wii- Balance-Boards die Gleichgewichtsstabilität in Ruhe und Lärm miteinander verglichen wurde.
Ziel der jetzigen Arbeit war es, herauszufinden, ob es signifikante Unterschiede der posturalen Kontrolle in Ruhe und in Lärm gibt, gemessen zum einen mit dem VertiGuard®-System, zum anderen mit der Enke-Platte. Des Weiteren sollte verglichen werden, ob sich die Gleichgewichtsstabilität in Lärm genauso gut trainieren lässt wie in Ruhe. Die Probanden wurden audiologisch eingangsuntersucht und in WHO- Gruppen unterteilt, da man ebenfalls herausfinden wollte, ob der individuelle Hörverlust Einfluss auf das Gleichgewicht des Probanden hat. Zu guter Letzt stellte sich die Frage, ob das VertiGuard®-System auf die gleichen Ergebnisse kommt wie die Enke-Platte.
An dieser Studie nahmen 17 Probanden teil, die folgende Anforderungen erfüllten:
Die Probanden mussten das 60. Lebensjahr vollendet haben. Allgemeine Schwindelsymptomatik, deren Ursache unklar ist, war Voraussetzung. Ein vorhandener Hörverlust war wünschenswert, Normalhörigkeit allerdings kein Ausschlusskriterium. Schwindelsymptomatik, die von pathologischen Erkrankungen wie Morbus Menière ausgeht, war Grund für eine Verweigerung der Teilnahme.
Der Lärm, der für einen Teil der Studie benötigt wurde, war eine eigens dafür erstellte Tonspur, die vor Studienanlauf mit einem Kunstkopf von Head Acoustics an einer Bundesstraße und einer stark befahrenen Stadtkreuzung aufgenommen wurde.
Die Probanden mussten nach der audiologischen Voruntersuchung einen gSBDT mit dem VertiGuard® durchlaufen und ein Balance-Screening mit der Enke-Platte absolvieren. Bei dem darauffolgenden Termin wurde der gleiche Ablauf nochmals in Lärm durchgeführt. Auf Grund des VertiGuard®-Ergebnisses wurden fünf Trainingstermine vereinbart, bei denen an jedem Trainingstermin fünfmal hintereinander das vorgeschlagene Training des VertiGuard® absolviert wurde. Nach diesem Training wurde ein Abschluss-gSBDT und ein abschließendes Balance-Screening durchgeführt.
Anhand dieser erhobenen Daten wurden mittels diverser statistischer Tests die oben erwähnten Hypothesen überprüft.
Dabei stellte sich heraus, dass der individuelle Hörverlust bei der Auswertung des Sturzrisikos mit dem VertiGuard® keinen Einfluss hatte. Im Gegensatz dazu ergaben sich bei der Auswertung mit der Enke-Platte aber Unterschiede zwischen den einzelnen WHO-Gruppen, die tendenziell darauf schließen lassen, dass der Hörverlust einen Einfluss haben könnte, der aber auch altersbedingt zustande gekommen sein könnte.
Außerdem zeigte sich, dass Lärm keinen Einfluss auf das Gleichgewicht hat. Das Training in Lärm zeigte effektive Erfolge. Dieses Ergebnis konnte sowohl mit dem VertiGuard®, als auch mit der Enke-Platte beobachtet werden.
Mit dieser Thesis galt es herauszufinden, welche Schalleigenschaften Freizeitmusik von (Musik-) Vereinen aufweist, ob diese das Potential besitzt, das Hörorgan zu
schädigen und ob eventuelle Auswirkungen bei den Musiker/innen bereits erkennbar waren. Ein Vergleich mit der LärmVibrationsArbSchV war ebenfalls ein Ziel.
Der Schall wurde mit Hilfe eines Kunstkopfmesssystems und eines Dosimeters aufgezeichnet und ausgewertet. Die Auswertung fand durch Dritteloktavbänder, Wavelets, Leq-Histogramme, Impulse und die Werte Peak, Minimum, Maximum, Leq und LEX 8h statt. Analysiert wurden 3 Musikvereine, 2 Fanfarenzüge und 1 Guggenmusik-Verein. Ein Fragebogen u.a. zu den Themen anderweitige Lärmbelastung(en), Bewertung der Musik ihrer Gruppe, körperliche Auswirkungen und Gehörschutz wurde von 104 Musiker/innen beantwortet. Von einem Hörtestscreening wurden 24 Audiometrien ausgewertet, die mit der DIN EN ISO 7029 altersbereinigt wurden. Mit diesen wurde ein Durchschnittsaudiogramm mit dem Mittelwert und der Standardabweichung gebildet.
Die Lautstärke der Musikgruppe wurde von ca. 90 % der Musiker/innen als laut bzw. sehr laut und von einer Person sogar als unangenehm empfunden und 19 % hatten schon ein- bzw. mehrmals Ohrgeräusche nach Proben und/oder Auftritten.
Im Gegenzug hierzu trug jedoch fast keiner der Proband/innen Gehörschutz beim Musizieren, obwohl sich 43 % Sorgen um ihr Gehör machten. Das Durchschnittsaudiogramm zeigte hierbei jedoch keine Auffälligkeiten, genau so, wie die Impulse. Impulshaltigkeit spielte in diesem Zusammenhang keine Rolle.
Die Peaks reichten von 117 bis 136 dB, die Maxima von 107 bis 115 dB und die Minima von 42 bis 64 dB. Der Leq erreichte Werte zwischen 90 und 106 dB und der LEX8h Werte zwischen 87 und 94 dB. Damit überschritt der LEX 8h in allen 6 Vereinen den unteren Auslösewert von 80 dB(A), in 5 der 6 Vereine sogar den oberen Auslösewert von 85 dB(A) der LärmVibrationsArbSchV. Gehörschutz sollte hier also auf jeden Fall getragen werden.
Potential im Aufklärungsbedarf besteht hier für die Hörakustiker, da den wenigsten Musikerinnen und Musikern bekannt war, dass es speziellen und individuellen Gehörschutz für Musik gibt.
In the fast-growing but also highly competitive market of battery-powered power tools, cell-pack-cooling systems are of high importance, as they guarantee safety and short charging times. A simulation model of an 18 V power tool battery pack was developed to be able to evaluate four different pack-cooling systems (two heat-conductive polymers, one phase change material, and non-convective air as reference) in an application scenario of practical relevance (the intensive use of a power tool followed by cooling down and charging steps). The simulation comprises battery models of 21700 cells that are commercially available as well as heat transfer models. The study highlights the performance of the different cooling materials and their effect on the maximum pack temperature and total charging cycle time. Key material parameters and their influence on the battery pack temperature and temperature homogeneity are discussed. Using phase change materials and heat-conductive polymers, a significantly lower maximum temperature during discharge (up to 26%) and a high shortening potential of the use/charging cycle (up to 32%) were shown. In addition to the cooling material sweep, a parameter sweep was performed, varying the external temperature and air movement. The high importance of the conditions of use on the cooling system’s performance was illustrated.
Banken sind in den letzten Jahren immer wieder in die Kritik geraten. Die Finanzkrise hat das Vertrauen der Kunden erschüttert, Banken in den Ruin getrieben und immer mehr Menschen misstrauisch gemacht. Umso wichtiger ist es jetzt, dass Finanzdienstleister gute Berater und Mitarbeiter haben, denen man vertrauen und auf deren Rat man sich verlassen kann. Es ist entscheidend, alle Mitarbeiter zu Höchstleistungen zu motivieren und nicht nur nach dem Vertriebsergebnis streben zu lassen. Würde man sie optimaler und ihren Stärken entsprechend einsetzen, dann könnte man höhere Leistungsmaxima erreichen und die Kunden umso zufriedener stellen und neues Vertrauen gewinnen. Während ausreichend Literatur über die Personalplanung sowie über Entwicklungsmöglichkeiten der Mitarbeiter verfügbar ist, wird nur spärlich über den Zusammenhang zwischen der Berücksichtigung fachlicher und persönlicher Bedürfnisse und Wünsche der Mitarbeiter und der optimalen Nutzung der Leistungskapazitäten berichtet. Die Gestaltung der Personalpolitik ist ein wichtiger Erfolgsfaktor für das Unternehmen. Das Thema wurde im Rahmen zweier Thesen untersucht: 1. Wäre es sinnvoll, ein Rotationsprinzip innerhalb einer Bank einzuführen? Dabei wurde untersucht, wie es funktionieren könnte, den Kundenstamm zwischen den Mitarbeitern „rotieren“ zu lassen. 2. Gleichzeitig wurde geprüft, wie durch Aufgabenteilung eine höhere Effizienz sowie mehr Kundenzufriedenheit und Mitarbeiterzufriedenheit erreicht werden kann. Durch die Aufteilung des Personals in Teams, kann jeder da eingesetzt werden, wo seine Stärken liegen und er am meisten effektiv sein kann und die höchste Leistung bringt. In der ursprünglichen Variante, musste jeder Mitarbeiter von Anfang bis Ende - vom Backoffice, über die Kundenberatung bis hin zum Abschluss eines Vertrages alles machen, unabhängig davon, ob er kommunikativ war oder lieber im Hintergrund arbeitete und dort wesentlich mehr Leistung bringen konnte.
Soft magnetic Fe-Al alloys have been a subject of research in the past. However, they never saw the same reception in technical applications as the Fe-Si or Fe-Ni alloys, which is, to some extent, due to a low ductility level and difficulties in manufacturing. Additive manufacturing (AM) technology could be a way to avoid issues in conventional manufacturing and produce soft magnetic components from these alloys, as has already been shown with similarly brittle Fe-Si alloys. While AM has already been applied to certain Fe-Al alloys, no magnetic properties of AM Fe-Al alloys have been reported in the literature so far. Therefore, in this work, a Fe-12Al alloy was additively manufactured through laser powder bed fusion (L-PBF) and characterized regarding its microstructure and magnetic properties. A comparison was made with the materials produced by casting and rolling, prepared from melts with an identical chemical composition. In order to improve the magnetic properties, a heat treatment at a higher temperature (1300 °C) than typically applied for conventionally manufactured materials (850–1150 °C) is proposed for the AM material. The specially heat-treated AM material reached values (HC: 11.3 A/m; µmax: 13.1 × 103) that were close to the heat-treated cast material (HC: 12.4 A/m; µmax: 20.3 × 103). While the DC magnetic values of hot- and cold-rolled materials (HC: 3.2 to 4.1 A/m; µmax: 36.6 to 40.4 × 103) were not met, the AM material actually showed fewer losses than the rolled material under AC conditions. One explanation for this effect can be domain refinement effects. This study shows that it is possible to additively manufacture Fe-Al alloys with good soft magnetic behavior. With optimized manufacturing and post-processing, further improvements of the magnetic properties of AM L-PBF Fe-12Al may still be possible.
Abstract Comparative measurements of elder dementia patients using multiple choice auditory graphic interactive check (MAGIC) and standard audiometry Setting Considering the demographic change of Germany (Statistisches Bundesamt, 2011) and the accordingly increasing risk of age-related diseases (Neubauer, et al., 2011), this research analyzes the measurement of deafness of probands who suffer from dementia, aged between 69 and 95 years with an average age of 86,3 years. One characteristic of dementia disease is communication problems (Alzheimer, 1911; Richter, 2003), which can be intensified by an eventually coexisting deafness (Lin, et al., 2011). Object of investigation The investigation, informing this research, engages in the question, wether an established audiometry for children can simplify the screening of hearing of elder people suffering from dementia and to what extent an additional loss of hearing can be detected. Research method The measurements were performed with a standard audiometry and compared to a multiple choice auditory graphic interactive check (MAGIC) (PATH, 2011) to analyze the grade of deafness of 18 nursing home residents (72 % female, 28 % male) who were diagnosed with dementia beforehand. The used ranges of frequencies in this measurement were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. Results Out of this group of probands 7 persons could be tested with the standard audiometry and 6 persons could be tested with the MAGIC. 5 persons could be tested also with the standard audiometry and the MAGIC. It was noticeable, that more probants were diagnoseable with the standard audiometry than there were with the MAGIC. During conducting the measurements it was often difficult for the probands to follow the sequence of the MAGIC. Conclusions The utilisation of the MAGIC in its current design is only restricted recommendable related to people suffering from dementia at present and often must be replaced by a the standard audiometry. The measurements performed in the context of this rersearch show the importance and necessity to diagnose a loss of hearing, since all probands showed signs of deafness. Keywords: demographic progress - dementia – MAGIC – standard audiometry
Die Zielsetzung dieser Arbeit ist die Erforschung des Einflusses von Künstlicher Intelligenz und Big Data auf die „Customer Journey“ und „Customer Experience“ von Video-on-Demand Anbietern.
Es werden bereits bestehende Anwendungsbeispiele und zukünftige Entwicklungen von Künstlicher Intelligenz bei Video-on-Demand Anbietern betrachtet. Durch die Auswertung unterschiedlicher Fachzeitschriften, technischen Dokumente und wissenschaftlichen Studien konnten verschiedene Aussagen zum Thema getroffen werden.
Im Endergebnis ist zu sagen, dass gerade Künstliche Intelligenz bereits großen Einfluss auf die „Customer Journey“ hat. Sie kann dabei einer der Faktoren sein, die nachhaltigen Einfluss auf die weitere Entwicklung des Video-on-Demand Marktes hat. Für die Zukunft gilt, weiter zu beobachten wie sich die Nutzergewohnheiten ändern. Am Ende entscheidet der Kunde welches Programm er einschalten will.
Das Ziel der vorliegenden Bachelorarbeit ist es, ein Vorkonzept für die Brillenversorgung in Namibia von Kindern im Alter von 8 bis 12 Jahren zu erstellen. Die einzelnen möglichen Abläufe liegen verschiedenen Hilfsorganisationen zu Grund. Basierend auf den Durchführungen der Einsätze von Vereinen wie Brillen Weltweit, EinDollarBrille und Entwicklungsdienst Deutscher Augenoptiker sind verschiedene Konzepte entstanden, die unterschiedliche Schwerpunkte aufweisen.
Argentinien befindet sich im Jahr 2019 in einer schweren Wirtschaftskrise, was sich in der Inflationsrate, dem Wechselkurs des argentinischen Pesos, der Leistungsbilanz, der Armutsrate und anderen makroökonomischen Kennzahlen wiederspiegelt.
Problematisch ist die historische Frequenz von wiederkehrenden Wirtschaftskrisen.
Das Land kann kein nachhaltiges Wirtschaftswachstum über einen längeren Zeitraum in der jüngeren Geschichte nachweisen. Daher wird der Fragestellung nachgegangen, ob das Mundell-Fleming Modell bei flexiblem Wechselkurs zur makroökonomischen Analyse der argentinischen Volkswirtschaft geeignet ist, um modellkonforme Maßnahmen zur Krisenbewältigung beurteilen zu können. Ziel dieser Bachelorarbeit ist es, dem Leser eine theoretische Grundlage der Thematik zu vermitteln und anhand einer Datenanalyse mittels deskriptiver Statistik die Gründe und Auswirkungen der aktuellen Wirtschaftskrise darzulegen. Zudem soll die Effektivität der Gegenmaßnahmen von verschiedenen Seiten aufgezeigt werden.
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
Zweck: Das Ziel dieser Studie ist es die Wahrnehmung und Akzeptanz von Unschärfe beim seitlichen Blick durch ein Gleitsichtglas zu untersuchen. Mit dem Blurtest sollte eine geeignete Methode zur Messung von Sehbereichsbreiten bei Gleitsichtgläsern entwickelt und verifiziert werden.
Material/Methoden: Die horizontalen Sehbereichsbreiten von vier Gleitsichtgläsern unterschiedlicher Progressionskanalbreite (2, 3, 4 und 5 mm) und linearem Wirkungsanstieg sollten bei einem Beobachtungsabstand von 40 cm für drei Unschärfekriterien gemessen werden. Die Grenzen für bemerkbare, tolerierbare und unakzeptable Unschärfe werden für einen am Bildschirm dargebotenen sinnfreien Text in Schriftgrad 9 pt (Visus = 0,4) links und rechts des monokularen Blickfelds markiert. Zusätzlich sollte in einem Vortest (Pretest) nach diesen Kriterien verschwommener, gedruckter Text beurteilt werden.
Ergebnisse: Die Grenzen für eben bemerkbare, tolerierbare und unakzeptable Unschärfe liegen bei einem Astigmatismus in Gebrauchsstellung von 0,70 ±0,3 dpt, 1,37 ±0,50 dpt und 2,06 ±0,74 dpt bei einem natürlichen Pupillendurchmesser von durchschnittlich 3,37 mm. In 40 % der Fälle unterscheiden sich die Grenzen für Unschärfe innerhalb eines Probanden nicht signifikant. Es besteht ein Zusammenhang zwischen der Toleranzbereitschaft unscharfe Texte in Alltagssituationen zu lesen und der Beurteilung von modifiziertem, gedrucktem Text.
Fazit: Die markierten Sehbereichsbreiten korrelieren mit dem horizontalen Anstieg des unerwünschten Astigmatismus, lassen sich bei Wiederholungsmessungen am Blurtest jedoch nicht auf ≤ 2° Schwankungsbreite reproduzierbar nachweisen. Die Definition, Wahrnehmung und Toleranz von Unschärfe in verschiedenen Alltagssituationen hängen von individuellen Erfahrungswerten und gesetzten Anspruch an Seh- bzw. Leseleistungen ab.
Die Virtual Reality Brillen Technik und ihre Nutzungsmöglichkeiten in der Augenoptik und Optometrie
(2019)
Das Ziel der vorliegenden Bachelorarbeit ist es, einen Überblick über die Einsätze der Virtual Reality Brillen Technik in der Augenoptik und Optometrie zu geben und
gleichzeitig auch auf die Technik hinter der Virtual Reality Brillen einzugehen.
Hierzu werden zu Beginn die Arten und Funktionsweisen der unterschiedlichen Geräte auf dem Markt vorgestellt und miteinander verglichen. Anschließend werden Problematiken bei der Verwendung von Virtual Reality Brillen diskutiert. Die Basis der Arbeit bildet die Darstellung und Aufführung von bereits erfolgreichen Einsätzender Virtual Reality Brillen in der Augenoptikbranche, sowie die Vorstellung von gelungenen Einsätzen der Technik in Studien, hinsichtlich therapeutischer Maßnahmen in der Optometrie.
Ableitend daraus werden eigene Nutzungsmöglichkeiten erarbeitet, die als Ideen und Denkanstöße für zukünftige Virtual Reality Anwendungen in der Augenoptik, dienen sollen.
In dieser Arbeit wird speziell nur auf die Technik der Virtual Reality Brillen und nicht auf die gesamte Virtual Reality Technik eingegangen.
Die Bachelorarbeit ist sowohl für Schüler und Studierende in der Augenoptik, als auch für alle Interessenten des augenoptischen Fachgebietes interessant. Alle aufgeführten Einsätze entsprechen dem aktuellen Stand 2018.
„The secret of getting ahead is getting started.“ (Mark Twain)
Die Augenoptik-Branche befindet sich bedingt durch technische Innovationen und Fortschritte im Umbruch. Die vorliegende Bachelorthesis gibt einen Überblick über die aktuelle Situation der Optometrie in Deutschland und zeigt Potenziale auf, die die fortschreitende Digitalisierung Optometristen in Großbritannien und in den USA bietet.
In dieser Bachelorthesis werden die auf Basis von Recherchen und Experteninterviews im UK Foresight Project Report zusammengefassten Ergebnisse auf den deutschen Markt hinsichtlich Beratung Verkauf, Refraktion und optometrische Untersuchungen sowie Kontaktlinsenanpassung und Low Vision übertragen. So werden in dieser Bachelorthesis akkommodationsfähige Kontaktlinsen, Gadgets zur Selbstrefraktion und auch Neuerungen wie E-Health genauer betrachtet.
U. a. wird in der vorliegenden Thesis auf die folgenden
Fragen näher eingegangen: Welche Trends sind für die Augenoptik-Branche in Deutschland relevant? Mit welchen technischen und prozessorientierten Innovationen ist in den kommenden Jahren zu rechnen und welche Möglichkeiten bieten die Innovationen im Zusammenspiel mit der Digitalisierung dem einzelnen Augenoptiker und Optometristen? Woran muss der Augenoptiker in Deutschland verstärkt arbeiten, um auch zukünftig im Markt erfolgreich sein?
Eine Erkenntnis ist: Zur Erzielung von Wettbewerbsvorteilen gegenüber Filialisten und Online-Brillenhändlern kann die
Optometrie für selbstständige Augenoptiker zu einem wichtigen Differenzierungsmerkmal werden. Anhand des UK-Foresight Project Reports und der vorliegenden Bachelorarbeit wird deutlich, wie wichtig das frühzeitige Erkennen der insbesondere durch die Digitalisierung möglichen Veränderungen und der damit verbundenen Chancen und Risiken ist, um auch zukünftig erfolgreich zu sein. Die Veränderungen müssen angepackt und genutzt werden, um in der Flut der Digitalisierung und der Innovationen nicht unterzugehen.
Das Ziel dieser Arbeit ist die Erstellung eines Konzepts für eine Software zum Erler-nen der Refraktionsbestimmung, welches die Erweiterung um zusätzliche Refraktionsschritte und Refraktionsmethoden sowie eine Umsetzung der Programmierung ohne augenoptische Kenntnisse ermöglicht. Die Programmgestaltung soll in Oberfläche, Funktionsumfang und Probandeneigenschaften der realistischen Refraktionsbestimmung näher kommen als die bisher verfügbaren Refraktions-Simulationsprogramme „Refsim7“ und „Electric Optitian PE“.
Das Konzept umfasst die monokulare Refraktion für die Ferne mit den Methoden Kreuzzylindermethode und Zylindernebelmethode für die Bestimmung des Astigmatismus und Rot-Grün-Test und Sukzessiv-Abgleich als Methoden für den monokularen sphärischen Feinabgleich. Des Weiteren umfasst es die Umsetzung vier verschiedener Eigenschaften des Probanden, die sich auf die Kommunikation auswirken: normales Verhalten, kann sich nicht entscheiden, verwechselt rechts und links und hört schlecht. Ebenso werden in dem Konzept die Aspekte Augenerkrankungen und Hornhautscheitelabstand berücksichtigt. Dazu gibt es fünf verschiedene Auffälligkeiten des Probanden, die auf den Erkrankungszustand des Auges, auf das Erkrankungsrisiko oder auf die Berücksichtigung des HSA schließen lassen. Diese sind starke Refraktionsänderung über einen kurzen Zeitraum, ein optisch nicht korrigierbares Problem, ein geringer Visus, ein höheres Probandenalter und eine höhere Fehlsichtigkeit.
Die Vorgehensweise für die Arbeit ist wie folgt strukturiert. Zunächst wird eine Recherche über bestehende Programme zum Erlernen der Refraktion durchgeführt. Anschließend erfolgt die Erarbeitung von Grundlagen zur Refraktionsbestimmung und anderen Aspekten der Refraktion. Abschließend wird das Konzept aus der Recherche und den Grundlagen erarbeitet.
Ziel dieser Bachelorthesis ist die Entwicklung eines zukunftsfähigen Geschäftsmodells für Optometristen in deutschsprachigem Raum. Die augenoptische Branche ist aufgrund der intensiven Konkurrenzsituation durch einen starken Preisdruck gekennzeichnet. Für inhabergeführte Fachgeschäfte wird es zunehmend schwieriger gegenüber Filialisten und dem Online Handel zu bestehen. Zugleich befindet sich die Branche in einem Umbruch. Immer häufiger werden Weiterbildungen in Richtung Optometrie angeboten. In dieser Bachelorthesis wird untersucht, ob und wie durch das Angebot optometrischer Dienstleistungen wirtschaftliche Erfolgsfaktoren erreicht werden können.
Hierfür wird zunächst die augenoptische Branche genauer betrachtet und der Bedarf und die Nachfrage an Optometrie ermittelt. Darauf aufbauend wird das Geschäftsmodell des Primary Eye Care Providers entwickelt. Dem Kunden wird hier eine Komplettversorgung rund um das Sehen angeboten, sowohl an Sach- als auch an Dienstleistungen.
Im empirischen Teil der Arbeit wird anhand einer Umfrage geprüft, ob dieses Geschäftsmodell für Augenoptiker zukunftsfähig sein kann. An dieser Umfrage beteiligten sich 80 Augenoptiker aus dem deutschsprachigen Raum (zum größten Teil aus Deutschland).
Das Geschäftsmodell des Primary Eye Care Providers stellt sich als ein interessantes Geschäftsmodell für Optometristen heraus. Dabei erfolgt nicht nur die Sehstärkenbestimmung beim Augenoptiker, sondern auch eine umfassende Augenuntersuchung. So können Augenerkrankungen frühzeitig erkannt und die bestmögliche Versorgung dieses wichtigen Organs gesichert werden.
Im Rahmen des Dosimeterprojektes befasst sich diese Bachelorarbeit damit, geeignete Impulsschallquellen zu identifizieren, die reproduzierbare Testsignale mit unterschiedlicher Pegel- und Zeitcharakteristik liefern. Beim Messsystem handelt es sich um ein Gerät der Firma National Instruments und die Knallmessungen für diese Arbeit wurden mit dem von der Firma National Instruments entwickelten Softwaresytems LabVIEW durchgeführt. Das Softwaresystem erfasst die Charakteristika des Knalls mit Anstiegsflanke und Wirkzeit sowie Peaklevel und Frequenzcharakteristik, welches entscheidende Parameter für die Bewertung der Knalle sind und in Zukunft für das Dosimeterprojekt entscheidend für das Ausmaß der zu beobachteten Schäden und ermöglicht somit Information über den täglichen Impuls- Zeitverlauf. Im Vorfeld wurde ein Knall im Idealfall als reproduzierbar definiert mit einer Abweichung von +/- 1dB in Bezug auf den Spitzenschalldruckpegel. Jede Referenzquelle wurde in verschiedenen Abständen und Einfallswinkeln zum Mikrofon jeweils vier Mal gemessen. Nach einigen Messungen verschiedener Knallquellen stellten sich folgende als „am reproduzierbarsten“ heraus: • Die schwarze Klappe mit einem Mittelwert aller Standardabweichungen von 0,20 • Die helle Klappe mit einem Mittelwert aller Standardabweichungen von 0,23 • Der schwarze Klicker mit einem Mittelwert aller Standardabweichungen von 0,29 • Die Schreckschusspistole mit einem Mittelwert aller Standardabweichungen von 0,60 Dieses sehr gute Ergebnis in Bezug auf die Reproduzierbarkeit der Knallquellen lässt sich damit erklären, dass beide Referenzquellen aufgrund ihrer vorgegebenen, nichtveränderbaren Konstruktion bei Betätigung knallen und dabei ein konstantes Ergebnis der entscheidenden Parameter liefern. Allerdings bringt jede Referenzquelle auch eine Schwierigkeit bei der Messung mit, die beachtet werden muss. Die Messergebnisse in dieser Bachelorarbeit sind repräsentativ und erfüllen die Bedingungen einer reproduzierbaren Knallquelle und somit wurden vier Referenzquellen identifiziert, die im Rahmen des Dosimeterprojektes geeignet sind.
In dieser Bachelorarbeit geht es darum, ein System zu bauen, mit dem die Augenbewegungen gemessen werden können bei Verwendung von GS und im Vergleich dazu bei Verwendung von Einstärkengläsern (ES). Das System soll eine natürliche Lesesituation simulieren. Es sollen die Grenzen herausgefunden werden, wo der astigmatische Fehler beim Tragen von GS gerade noch akzeptiert wird. Hierfür soll keine Augentrackingbrille verwendet werden, sondern aufgrund der Kopfbewegungen (KB) und dem Wissen wo der Proband hinschaut, die Augenbewegungen (AB) berechnet werden.
Ziel dieser Arbeit ist es, das Zielgruppenmodell Roper Consumer Styles (RCS)
der Gesellschaft für Konsumforschung (GfK) genau zu beschreiben und dessen
Anwendbarkeit auf die Augenoptik zu prüfen.
Zu Beginn werden die Geschichte und Entwicklung der Roper Consumer Styles
(RCS) sowie das Modell selbst und seine einzelnen Lebensstile erläutert. Im
zweiten Teil setzt sich diese Arbeit mit der Anwendung der Roper Consumer
Styles (RCS) in der Augenoptik auseinander. Es wird ein Pilotprojekt vom
Zentralverband der Augenoptiker (ZVA) und der Gesellschaft für Konsumforschung
(GfK) vorgestellt. Die Gesellschaft für Konsumforschung (GfK) bestimmt
das Einzugsgebiet des Optikers, analysiert die Kundschaft in dem Gebiet und
zeigt auf, bei welchen Zielgruppen noch Potenzial besteht. Der Optiker bekommt
von der Gesellschaft für Konsumforschung (GfK) konkrete Empfehlungen,
welche Marken und welche Designs die gewünschten Zielgruppen ansprechen.
Es ergeben sich vier Bereiche, in denen die Roper Consumer Styles (RCS) in
der Augenoptik angewandt werden können: Produkt/Sortimentspolitik, Preispolitik,
Kommunikationspolitik und Ladenbau/Schaufenstergestaltung. Anschließend
wird das Projekt einer kritischen Würdigung unterzogen. Dabei werden zwei
Verbesserungsvorschläge vorgebracht. Ein Vorschlag ist, die Fassungen nicht
nach Marken, sondern nach den Styles zu unterscheiden und eine Klassifizierung
der Fassungen nach den Roper Consumer Styles (RCS) zu machen. Der
andere Vorschlag ist, ein Kurzfragebogen zu entwickeln, der eine direkte
Einordnung des einzelnen Kunden nach den Roper Consumer Styles (RCS)
ermöglicht. Abschließend wurde eine Umfrage unter den Betrieben, die am
Projekt teilgenommen haben, durchgeführt. Die Ergebnisse der Umfrage zeigen,
dass das Zielgruppenmodell Roper Consumer Styles (RCS) in der Augenoptik
Anwendung findet und von den Optikern selbst auch als positiv bewertet wird.
Aus diesem Grund soll die Analyse der Gesellschaft für Konsumforschung (GfK)
in Zukunft für einen größeren Kreis von Betrieben angeboten werden.
Im Rahmen der vorliegenden Bachelorarbeit wurden bei 41 Probanden sowohl objektive als
auch subjektive Refraktionsbestimmungen durchgeführt. Bei den Probanden wurde die
klassische monokulare Refraktionsbestimmung mit dem Kreuzzylinder durchgeführt. Im
Anschluss an diese Messung, wurde ein monokularer Feinabgleich unter binokularen
Bedingungen für Sphäre, Zylinder und Achse am Zyklofusionstest durchgeführt. Ziel ist es zu
prüfen, ob zum einen die monokulare Refraktion unter binokularen Bedingungen am
Zyklofusionstest ein gleichwertiges Verfahren zur Refraktionsbestimmung ist wie die
monokulare Refraktion und zum anderen ob sich unter binokularen Bedingungen eine andere
Zylinderachse ergibt wie unter monokularen. Zu Beginn der Arbeit werden zunächst die
Grundlage zum Zyklofusionstest und der Aufbau des Testes erläutert. Zusätzlich wird in den
Methoden die Durchführung der Messung erläutert. In der Auswertung der Ergebnisse wurde
besonders auf die Zylinderachse und -stärke geachtet. Hier ergaben sich zwischen den beiden
Messverfahren leicht unterschiedliche Refraktionen. Im ersten Messdurchgang ergab sich für
die Differenz im sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,43 dpt und
im zweiten Messdurchgang von ±0,29 dpt um die mittlere Refraktion. Die beiden Messmethoden
unterscheiden sich daher nicht relevant voneinander. In 72% der Fälle führten beide
Messmethoden zur gleichen Visusstufe. Beim wiederholten Durchführen der Messung wurde in
77% der Fälle die gleiche Visusstufe erreicht. Des Weiteren ergab sich für die beiden Verfahren
eine ähnliche Reproduzierbarkeit. Bei der binokularen Messung ergab sich für die Differenz im
sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,37 dpt und bei der
monokularen Messung von ±0,39 dpt um die mittlere Abweichung. Um die Handhabung und
die Anwendbarkeit interpretieren zu können wurden zum einen die Dauer der Messungen mit
einander verglichen und zum anderen die Probanden nach der Messung zu ihrer persönlichen
Meinung befragt. Für die Messung am Zyklofusionstest ergab sich eine Prüfdauer von ca. 10
Minuten. 56% der Probanden empfanden die Beurteilbarkeit während der monokularen
Refraktion am einfachsten und angenehmsten. Für 15% war die Beurteilung am Zyklofusionstest
einfacher und die restlichen 29% konnten keinen Unterschied in der Beurteilung
feststellen. Anschließend wird in der Diskussion auf Komplikationen während der Messung
anhand von Einzelfällen eingegangen und mögliche Fehlerquellen werden aufgezeigt.
Abschließend ist festzustellen, dass der Zyklofusionstest eine neue Messmethode ist, die im
Wesentlichen die gleichen Ergebnisse und eine gleich gute Reproduzierbarkeit wie die
klassische monokulare Refraktion aufweist und in Zukunft mit in den Refraktionsablauf
integriert werden kann.
Validierung des SNR mit Hilfe des OlSa in drei Lautstärken mit zwei verschiedenen Hörgeräteklassen
(2015)
Da Unterschiede zwischen Low-End- und High-End-Hörsystemen nicht mehr in Ruhe nachgewiesen werden können, wurde in dieser Studie der Unterschied zwischen den beiden Hörsystemen überprüft. In bisherigen Studien konnte nur
eine Verbesserung des SNR durch eine Richtmikrofonwirkung nachgewiesen werden.
Um die Vorteile der weiteren Features und der höheren Kanalanzahl bei den High-End-Hörsystemen nachzuweisen, wurden in dieser Studie das Störgeräusch und das Sprachsignalaus der gleichen Richtung angeboten. Den Probandinnen und Probanden wurden jeweils ein Low-End- und ein High-End-Hörsystem nach NAL-NL2 angepasst. Dabei wurden sie in drei verschiedene Schwerhörigkeitsgrade eingeteilt und mit dem Oldenburger Satztest der SNR bei drei verschiedenen Störgeräuschlautstärken bestimmt.
Verglichen wurden sowohl der Unterschied in den einzelnen Gruppen von Schwerhörigkeitsgraden als auch die Verbesserung im Gegensatz zum unversorgten SNR. Es besteht tendenziell ein Unterschied zwischen den beiden Hörsystemen. In nahezu allen Störgeräuschlautstärken und allen Schwerhörigkeitsgraden wurde eine Verbesserung des SNR mit den High-End-Hörsystemen erreicht.
Der Vorteil der High-End-Hörsysteme wird mit lauterem Störgeräusch größer, so dass die Schwerhörigen vor allem in lauten Situationen von den Hörsystemen profitieren können.
Die Verbesserung des SNR mit den Hörsystemen gegenüber keiner Versorgung liegt bei den mittel- und hochgradig Schwerhörigen weit über der von der HilfsM-RL geforderten 2 dB.
Der Vorteil der High-End-Hörsysteme muss noch in weiteren Studien untersucht werden um einen signifikanten Unterschied zwischen den beiden Hörsystemen nachzuweisen, der in dieser Studie schon tendenziell nachgewiesen werden konnte.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.