Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (12)
- Master's Thesis (12)
- Article (9)
- Report (3)
Language
- English (36) (remove)
Is part of the Bibliography
- no (36) (remove)
Keywords
- Myopia (3)
- Studie (2)
- Adjustment Process (1)
- Affliliate Marketing (1)
- Agency Theory (1)
- Artificial Intelligence (1)
- Big Data (1)
- Choroidal thickness (1)
- City Development (1)
- Comparison metrics (1)
In this study, we investigate the use of artificial neural networks as a potentially efficient method to determine the rate capability of electrodes for lithium-ion batteries with different porosities. The performance of a lithium-ion battery is, to a large extent, determined by the microstructure (i.e., layer thickness and porosity) of its electrodes. Tailoring the microstructure to a specific application is a crucial process in battery development. However, unravelling the complex correlations between microstructure and rate performance using either experiments or simulations is time-consuming and costly. Our approach provides a swift method for predicting the rate capability of battery electrodes by using machine learning on microstructural images of electrode cross-sections. We train multiple models in order to predict the specific capacity based on the batteries’ microstructure and investigate the decisive parts of the microstructure through the use of explainable artificial intelligence (XAI) methods. Our study shows that even comparably small neural network architectures are capable of providing state-of-the-art prediction results. In addition to this, our XAI studies demonstrate that the models are using understandable human features while ignoring present artefacts.
Future lunar exploration will be based on in-situ resource utilization (ISRU) techniques. The most abundant raw material on the Moon is lunar regolith, which, however, is very scarce on Earth, making the study of simulants a necessity. The objective of this study is to characterize and investigate the sintering behavior of EAC-1A lunar regolith simulant. The characterization of the simulant included the determination of the phase assemblage, characteristic temperatures determination and water content analysis. The results are discussed in the context of sintering experiments of EAC-1A simulant, which showed that the material can be sintered to a relative density close to 90%, but only within a very narrow range of temperatures (20–30 °C). Sintering experiments were performed for sieved and unsieved, as well as for dried and non-dried specimens of EAC-1A. In addition, an analysis of the densification and mechanical properties of the sintered specimens was done. The sintering experiments at different temperatures showed that the finest fraction of sieved simulant can reach a higher maximum sintering temperature, and consequently a higher densification and biaxial strength. The non-dried powder exhibited higher densification and biaxial strength after sintering compared to the dried specimen. This difference was explained with a higher green density of the non-dried powder during pressing, rather than due to an actual influence on the sintering mechanism. Nevertheless, drying the powder prior to sintering is important to avoid the overestimation of the strength of specimens to be fabricated on the Moon.
Laser melting manufacturing of large elements of lunar regolith simulant for paving on the Moon
(2023)
The next steps for the expansion of the human presence in the solar system will be taken on the Moon. However, due to the low lunar gravity, the suspended dust generated when lunar rovers move across the lunar soil is a significant risk for lunar missions as it can affect the systems of the exploration vehicles. One solution to mitigate this problem is the construction of roads and landing pads on the Moon. In addition, to increase the sustainability of future lunar missions, in-situ resource utilization (ISRU) techniques must be developed. In this paper, the use of concentrated light for paving on the Moon by melting the lunar regolith is investigated. As a substitute of the concentrated sunlight, a high-power CO2 laser is used in the experiments. With this set-up, a maximum laser spot diameter of 100 mm can be achieved, which translates in high thicknesses of the consolidated layers. Furthermore, the lunar regolith simulant EAC-1A is used as a substitute of the actual lunar soil. At the end of the study, large samples (approximately 250 × 250 mm) with interlocking capabilities were fabricated by melting the lunar simulant with the laser directly on the powder bed. Large areas of lunar soil can be covered with these samples and serve as roads and landing pads, decreasing the propagation of lunar dust. These manufactured samples were analysed regarding their mineralogical composition, internal structure and mechanical properties.
Based on a data-driven approach, a computer-assisted workflow for the quantitative analysis of optical Kerr microscopy images of sintered FeNdB-type permanent magnets was developed. By analyzing the domain patterns visible in the Kerr image with data-driven approaches such as traditional machine learning and advanced deep learning, we can quantify grain orientation and size with a better trade-off between accuracy and higher throughput than electron backscatter diffraction (EBSD). The key distinction between traditional machine learning and advanced deep learning lies in feature extraction. Traditional methods require manual, user-dependent feature extraction from input data, while advanced deep learning achieves this automatically. The predictions from the trained models were compared to the measurements from EBSD for performance evaluation. The proposed data-driven model is trained on the dataset created from the correlative microscopy technique, which requires the images of grains extracted from the Kerr microscopy and corresponding EBSD grain orientation data (Euler angles). The fine-tuned deep learning model shows better generalization ability than the traditional machine learning models trained on the manually extracted features and resulted in a mean absolute error of less than 5° for grain orientation of the anisotropic magnet samples when evaluated against the measured EBSD values. The developed approach has reduced the measurement effort for grain orientation by 5 times and have sufficient accuracy when compared to the EBSD.
The surface topography of biodegradable polymer foils is modified by mechanical imprinting on a submillimeter length scale. The created patterns strongly influence the wetting behavior and allow the preparation of hydrophobic surfaces with controlled solid-liquid interaction. A detailed analysis of anisotropic surface patterns reveals that the observed effect arises from a combination of topographical and compositional changes that are introduced to the surface. As a main result it is found that an individual combination of material and structure is required for the production of water-repellent biopolymer foils that are highly attractive for packaging applications.
Soft magnetic Fe-Al alloys have been a subject of research in the past. However, they never saw the same reception in technical applications as the Fe-Si or Fe-Ni alloys, which is, to some extent, due to a low ductility level and difficulties in manufacturing. Additive manufacturing (AM) technology could be a way to avoid issues in conventional manufacturing and produce soft magnetic components from these alloys, as has already been shown with similarly brittle Fe-Si alloys. While AM has already been applied to certain Fe-Al alloys, no magnetic properties of AM Fe-Al alloys have been reported in the literature so far. Therefore, in this work, a Fe-12Al alloy was additively manufactured through laser powder bed fusion (L-PBF) and characterized regarding its microstructure and magnetic properties. A comparison was made with the materials produced by casting and rolling, prepared from melts with an identical chemical composition. In order to improve the magnetic properties, a heat treatment at a higher temperature (1300 °C) than typically applied for conventionally manufactured materials (850–1150 °C) is proposed for the AM material. The specially heat-treated AM material reached values (HC: 11.3 A/m; µmax: 13.1 × 103) that were close to the heat-treated cast material (HC: 12.4 A/m; µmax: 20.3 × 103). While the DC magnetic values of hot- and cold-rolled materials (HC: 3.2 to 4.1 A/m; µmax: 36.6 to 40.4 × 103) were not met, the AM material actually showed fewer losses than the rolled material under AC conditions. One explanation for this effect can be domain refinement effects. This study shows that it is possible to additively manufacture Fe-Al alloys with good soft magnetic behavior. With optimized manufacturing and post-processing, further improvements of the magnetic properties of AM L-PBF Fe-12Al may still be possible.
Transformations in the work–nonwork interface highlight the importance of effectively managing the boundaries between life domains. However, do the ways individuals manage the boundaries between work and nonwork life change from one day to the next? If so, which antecedents may explain these intra-individual fluctuations in boundary management? Drawing on boundary management, spillover, and resource theories, we investigate daily changes in segmentation preferences and integration enactments as a function of experiencing strain in work and nonwork life. Assuming that changes in segmentation preferences reflect an individual’s strategy to regulate negative cross-role spillover, we suppose that strain increases individuals’ segmentation preferences; at the same time, however, it could force individuals to enact more integration.
Identification and quantitative segmentation of individual blood vessels in mice visualized with preclinical imaging techniques is a tedious, manual or semiautomated task that can require weeks of reviewing hundreds of levels of individual data sets. Preclinical imaging, such as micro-magnetic resonance imaging (μMRI) can produce tomographic datasets of murine vasculature across length scales and organs, which is of outmost importance to study tumor progression, angiogenesis, or vascular risk factors for diseases such as Alzheimer’s. Training a neural network capable of accurate segmentation results requires a sufficiently large amount of labelled data, which takes a long time to compile. Recently, several reasonably automated approaches have emerged in the preclinical context but still require significant manual input and are less accurate than the deep learning approach presented in this paper—quantified by the Dice score. In this work, the implementation of a shallow, three-dimensional U-Net architecture for the segmentation of vessels in murine brains is presented, which is (1) open-source, (2) can be achieved with a small dataset (in this work only 8 μMRI imaging stacks of mouse brains were available), and (3) requires only a small subset of labelled training data. The presented model is evaluated together with two post-processing methodologies using a cross-validation, which results in an average Dice score of 61.34% in its best setup. The results show, that the methodology is able to detect blood vessels faster and more reliably compared to state-of-the-art vesselness filters with an average Dice score of 43.88% for the used dataset.
In the fast-growing but also highly competitive market of battery-powered power tools, cell-pack-cooling systems are of high importance, as they guarantee safety and short charging times. A simulation model of an 18 V power tool battery pack was developed to be able to evaluate four different pack-cooling systems (two heat-conductive polymers, one phase change material, and non-convective air as reference) in an application scenario of practical relevance (the intensive use of a power tool followed by cooling down and charging steps). The simulation comprises battery models of 21700 cells that are commercially available as well as heat transfer models. The study highlights the performance of the different cooling materials and their effect on the maximum pack temperature and total charging cycle time. Key material parameters and their influence on the battery pack temperature and temperature homogeneity are discussed. Using phase change materials and heat-conductive polymers, a significantly lower maximum temperature during discharge (up to 26%) and a high shortening potential of the use/charging cycle (up to 32%) were shown. In addition to the cooling material sweep, a parameter sweep was performed, varying the external temperature and air movement. The high importance of the conditions of use on the cooling system’s performance was illustrated.
Purpose: The aim is to be able to advise patients on the choice of sports and exercises regarding the effects on the intraocular pressure.
Methods: The search engines Google Scholar and PubMed were used to search for suitable studies. The studies were summarized, and the most important data were collected in one table for each study. The effect on the IOP was extracted or, if not given in the article, calculated by the difference of means of the IOP after or during exercise, and the baseline IOP before, whenever these values were available.
Findings: A total of 47 studies out of the years 1990 to 2020 that investigated the influence on the IOP of the most popular sports actively practiced in Germany were reviewed and summarized: twelve for running, sixteen for fitness/ weight training, one for swimming/diving, twelve for cycling, four for hiking, and two for yoga.
Conclusions: Throughout all studies and sports it was seen that physical fitness stabilized the IOP. Higher
intensity of exercise led to higher fluctuations of the IOP. Moderate endurance training keeps the IOP fluctuations low and may lead to a lower baseline IOP if practiced on a regular base. Fitness and weight training lead to fluctuations of the IOP in a pronounced manner when performed at moderate and high intensity. Therefore, only a moderate training can be recommended if there is need to keep the IOP stable. Isometric exercise is not recommended as it provokes a rise of the IOP even when performed with light loads. The Valsalva Maneuver should always be avoided as it leads to additional fluctuations of the IOP. Also, the IOP behaved more stable during resistance training when higher fitness was present.
Strategy development is one of the crucial factors for a firm's performance. For it
to be developed, a strategic analysis has to be conducted first. It enables
companies to gain a deeper understanding of their internal and external
environment. In the present work, the specialty coffee market is closely analyzed through a strategic analysis. The focus of this study is the young company Tikuna, a coffee producer that aims to enter the German market. In this context, Tikuna's possible entry into the German market and the companies competitive capacities are analyzed. In order to implement the different tools of the analysis, extensive literature research, as well as one expert interview and a survey were conducted.
It was found that Tikuna possesses all characteristics to enter the German
market. However, due to the lack of a differentiation factor in Tikuna's value
proposition, its competitive capacity is limited to a short period of time. In this
sense, different recommendations are given in order to ensure long term success
in the market. The central one being that Tikuna has to use its main strength and
bring innovation to the market.
Novel myopia control spectacle lenses induce peripheral contrast reduction via optical diffusion. It is suggested, that the contrast reduction alters retinal processes in the low-level neural circuity, leading to an inhibition of eye growth. The purpose of this thesis is to evaluate the influence of full-field contrast reduction on low-level neural processing of the retina, described by the edge contrast sensitivity.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.
This research project is of particular importance since there is a lack of adequate data on pediatric eye and vision disorders in Russia, particularly in the Volga region. In the present study, we estimate the prevalence of vision disorders among school-aged children who participated in a vision screening program in Samara, Russia. The relationship between learning-related visual dysfunctions is explored in depth, such to illustrate the connection between vision and learning. Hence, a key feature in this study is the inclusion of binocular vision disorders among the conditions tested.
The present study deals with the topic how a town can use its cultural heritage or,
more precisely, its industrial culture as a means to market itself as an innovative
business location and to foster a more pronounced sense of civic cohesion among
residents. Economic theory suggests that, nowadays, traditional location factors
such as access to resources and a performant infrastructure are less important than
in the industrial age. Recently, factors like a city’s potential to generate and retain
human and creative capital have emerged. Accordingly, the economic and social
role of cities has shifted – from a place where workers lived and manufactured
goods towards a deeply interwoven ecosystem of knowledge-intense value creation.
The question at the root of the present study is how Heidenheim’s rich industrial
cultural heritage can be used as a future-pointing source of power for rebranding
the town. This rebranding concept has to be developed according to the town’s role
in past, present and future, thus creating actual economic and societal value.
Industrial culture bears branding potential and is closely related to various aspects
of modern life and work. The study examines possibilities to create awareness for
these relations connecting past, present and future. Their relevance shall be
emphasized in order to establish both points of orientation and authenticity of place
in times when macroeconomic and societal trends are difficult to predict. Ideally,
residents shall be given a sort of local identification to hold on to, and potential
investors and entrepreneurs shall be encouraged to sustainably experience the
innovation-based DNA of Heidenheim. Therefore, the study searches for a value
proposition that takes into account the points mentioned above on terms of an
innovative theoretic framework. As a result of this thesis, precise suggestions for
the implementation of a new branding strategy based on the conceptual guidelines
developed in this study will be proposed to the municipality of Heidenheim and, in
addition, an interface using principles of virtual and augmented reality will be
introduced.
The increasing prevalence of myopia throughout the industrialized world in recent decades has caused costs and problems for the eye health. Changed lifestyle and behavior are the main causes. For the pathogenesis of myopia, the amount of time spent outdoor and near activities play an important role. Various options for the treatment of myopia have been described as effective in the literature. Normal single vision glasses and contact lenses can only provide clear vision, but do not reduce myopia progression. Orthokeratology shows a slowing of axial growth, but has an increased risk of infectious keratitis. Low-dose atropine (0.01%) is currently the best pharmacological option. It proved safe, effective and showed the least rebound effect with negligible side effects. Other options for the treatment of myopia include special glasses, behavioral changes and prolonged outdoor exposure (to prevent the onset of myopia), as well as other methods. An increasingly important myopia management option is multifocal contact lenses, that provide a peripheral treatment zone producing myopic defocus. Such myopia control lenses are available as customized or as daily or monthly lenses. Children benefit from wearing contact lenses more than just having refractive error correction and myopia control, they have a better self-esteem and improved quality of life. The numerous findings on the safety and efficacy of soft multifocal distance center contact lenses in children to reduce the progression of myopia suggest that this modality should be considered as a main treatment option. Less, but similar to orthokeratology, when wearing soft lenses there is a risk of developing potentially serious complications such as microbial keratitis. The introduction of child-appropriate risk minimization strategies, and patient and parent education with regular monitoring is essential and leads to successful contact lens wear. This literature review summarized the actual knowledge about myopia management, prevalence, etiology and the visual and healthy consequences of myopia.
The three currently most important strategies for slowing the progression of myopia are soft multifocal distance center contact lenses, Orthokeratology and low-dose atropine ophthalmic drops.
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
This research looks into the question of where and how Artificial Intelligence and Big Data can be usefully implemented into Affiliate Marketing. By consulting relevant literature and qualified experts, this work identifies 6 areas, where Artificial Intelligence can be beneficial. These areas were found to be Affiliate Recruitment, Affiliate Management, Product Data Feed Optimization, Tracking, Attribution and Forecasting.
The implementation of Artificial Intelligence in these areas revealed 3 advantages to the Affiliate Marketing channel: Saving of time, support of decision-making, and incentivizing of publishers. While a more detailed study of this research topic would be necessary for validating the results, the findings show that the implementation of Artificial Intelligence technology can help a business gain competitive advantage.
This paper describes an application analysis of one important topic of diversity
marketing – gender marketing. With the help of two surveys and content analyses
in two different media sectors – television and print media – the general trend of
gender representation in advertising could be located. While most survey
respondents are still using characteristics for males and females which were
shaped by traditional gender roles, most of them believe that the roles from the
1950s are outdated and that the media should adapt to the changes in societies in
regard to gender roles. However, the content analyses have shown that the
marketers have already adapted and are primarily presenting the viewers
contemporary images of men and women instead of the stereotyped ones from the
1950s. The only issue that has not changed yet is the color coding which starts to
differentiate between males and females since childhood. The findings of this
paper suggest that the perception and the reality do not always correspond with
each other and that, although the adoption of the change of gender roles is
advancing, it is still not completed yet.
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).
Abstract
1.1 Purpose
The purpose of this study is to prescribe follicular-like conjunctivitis associated with Siliconhydrogels
(FoCoSi) in silicone hydrogel contact lens wearers as a novel subtype of
the well prescribed contact lens induced papillary conjunctivitis (CLPC).
1.2 Methods
1211 patients who wore silicon hydrogels were included in this prospective, nonrandomised,
single center study. Subjective symptoms and clinical signs were evaluated
for daily wear (DW) and continuous wear (CW) populations for several (Lotrafilcon A,
Lotrafilcon B, Senofilcon A, Galyfilcon A) silicon hydrogel lens types. CCLRU and other
specifically developed grading scale were utilized for evaluation. Grading of 2 and above
was rated as clinically significant. Statistical evaluation was performed for eyes rather
than subjects.
1.3 Results
The clinical presentation of FoCoSi could be confirmed and showed an incidence of
3.8%. Lotrafilcon A followed by Senofilcon A on a CW modality presented, with a risk
ratio of 2.49 and 1.53 respectively, the highest affinity for developing FoCoSi. Fluorescein
positive spots showed the closest correlation with subjective symptoms reported
by patients and divided FoCoSi into an active and dormant form. Besides Protein, Lipid
deposition on the contact lens surface and air pollution like Ozone or fine and ultrafine
particles seems to be important factors in developing FoCoSi, whereas mechanical irritation
played a minor role.
1.4 Conclusion
FoCoSi is a novel and relevant subtype of CLPC. Further studies should be performed
to validate these findings and clear up several questions about the aetiology of FoCoSi
and CLPC.
Keywords: Giant papillary conjunctivitis (GPC), contact lens-induced papillary conjunctivitis
(CLPC), follicular-like conjunctivitis associated with siliconhydrogels (FoCoSi)
Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.
Purpose
The purpose of this study was to investigate the correlation of measured visual acuity
(VA) both static and dynamic obtained with static and dynamic measuring tests, as well
as, response time to visual stimulus and analysis of its influence on dynamic visual
acuity. The aim was to compare the results gathered for the three age groups and
analyze the possible differences.
Methods
The test groups consisted of 75 subjects between 10 and 60 years old, categorized in
three age groups. The measurements of static and dynamic visual acuity and reaction
time were conducted. The set of nine tests (five with radial magnification speed and four
simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure
dynamic visual acuity and the set of two tests for reaction time measurement.
Results
Compared to static visual acuity in both tests, the results obtained with measurements
of dynamic visual acuity resulted in lower values depending on Landolt ring size and
magnification speed of animation. In average, the dynamic visual acuities in tests with
different magnification speeds were lower than static by 0.4 visual acuity units, or 31%
and the average of dynamic visual acuity after subtracting motoric component (reaction
time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating
driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while
at 130 km/h average drop for younger and middle age groups was 37% and for older
group was 44% and after subtracting motor component values for 72 km/h speed
simulation average drop in visual acuity values was 23% for all three groups; for 130
km/h speed simulation younger and middle aged group average drop of visual acuity
was 20% and with older group it was 24%.
Conclusion
The tests used in this study were simple and fast and revealed significant difference
between static and dynamic visual acuity and influence of reaction time on dynamic
Nataša Vujko Muždalo Abstract
2
visual acuity values. It is hoped that this thesis will be a positive contribution in testing
and training of dynamic visual and sensory response skill with drivers, sportsmen and
people with visual-motor dysfunction.
Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT),
motoric component, dynamic visual acuity test, reaction time test, radial increase in size
Ophthalmic lenses are ideally measured in accordance with the center of rotation of the eye. Therefore a measuring device was constructed due to this principle to measure lenses with a focimeter. In this work that measuring device was validated. Lenses of ± 4 dpt in spherical and aspherical design were measured across a field of 9x9 measuring points being at 5° distance from each other. This corresponds to a field of view of 40°. The measurement points in x- and y- direction were theoretically calculated to validate the measurement results. Regarding angles of incidence up to 20° it was supposed that the main optical aberration depends on a change in the sagittal and tangential sphere powers which is also defined as astigmatism. Therefore the calculation presents the tangential and sagittal oblique sphere powers depending on the different angles of the line of vision. On average the measurement results and the calculated data of the spherical designed lenses coincide quite good (correlation at 0,98), the systematic deviation of both values on average is 0.01 dpt and the random error (standard deviation) amounts 0.03 dpt on average. The minimum deviation is -0.06 dpt and the maximum is 0.09 dpt. Common focimeters have a measuring inaccuracy of up to 0.06 dpt (Diepes, Blendowske 2002). Therefore the quality of the measured data should be reliable. The aspherical designed lenses were compared to the spherical designed lenses. With increased angles of incidence the astigmatism of the aspherical lenses leads to lower values than the astigmatism of the spherical lenses
The present thesis deals with alternative powertrains, focusing on electric vehicles
and hybrid vehicles and which of those alternative powertrains is considered as
sustainable for the future. It explores the question, which alternative powertrain is
worthwhile investing in for German automotive suppliers. The aim is to clarify
which of the two powertrains is already established on the market and what the
future prospects of those powertrains are. The question here is evaluated based on
the analysis of current literature as well as through the use of a SWOT analysis
and the use of the scoring model.
As a result it is clear that there is a need for alternative powertrains and the entire
automotive industry invests a lot in the development and research of alternative
powertrains. According to the German Federal Government, one million electric
vehicles should be on German roads by 2020. With pure electric vehicles, however,
the goal will be difficult to reach. Therefore, there is a lot of vested interest in
the development of hybrid vehicles on the market. It shows that the hybrid vehicle
has considerable advantages over the electric vehicle and the hybrid vehicle is
already seen as a transitional solution for pure electric vehicles. The hybrid vehicle
is also already established in the market and has better chances on the market
in the future. Therefore, it makes sense for German automotive suppliers to invest
in hybrid vehicles and to focus on this market, since there the chances of success
are greater and the future potential of this market is higher.
This paper deals with the question of which factors have to be given for
successful share repurchases that create long-term shareholder value. Center of
the thesis is the agency theory and its influence on share repurchases. Based on
theoretical findings success factors for share repurchases are derived and then
verified by case studies.
The main drivers for a successful share repurchase elaborated by this paper are a
suitable long-term executive compensation, an independent board of directors and
a shareholder structure without a majority shareholder. Additionally the findings
show that tying repurchases to certain share price thresholds improves the quality
of share repurchases.
This paper aims to provide essential information about the formal aspects of the adjustment process companies in Southern Germany utilize to adjust their employees to new surroundings. In particular, it shall be investigated and defined what formal aspects are and when firms apply them. Literature shows that companies do implement language courses, intercultural trainings or provide further information about the host country before a stay abroad. Nevertheless, the phases during and after the assignment are not taken into account with the required importance. Additionally, since national culture can be broken down into different layers, the organizational culture as one layer was analyzed, too.By conducting a quantitative research among companies in Baden-Württemberg, this paper shows the different approaches for dealing with a stay abroad. Scientific literature about the topic of adjustment of globally assigned workers shall help emphasizing the need of a deeper cultural insight. Furthermore, by attempting to explain the organizations’ culture, a better understanding of the chosen training methods shall be created. Definitions in the beginning helped to understand the concept of culture, the notion and the phases of adjustment. Almost all collected data has been accessed either through JSTOR (a digital library founded to help academic libraries or publishers) or similar databases, through the companies’ websites or through the survey results it selves.The results of this research show that the phase before the stay abroad is organized well. Companies offer pre-departure training, but during and after the expatriate time a lack of support is being observed. The firms obviously underestimate the necessary help needed during the assignment and in the return phase, which is why the thesis attempts to fill this gap. Through the organizational culture, described on the companies’ webpages the author was able to draw a conclusion to the applied training methods, which results in a consistent overall picture of the described firms. Companies from the automotive sector had the highest return rate in the survey, which is why particular attention was paid to it.
Aim Patrick J. Caroline and Mark P. Andre first reported about soft lens orthokeratology in 2005. In a number of articles in the past five years, they reported about their research on this topic and their new findings. The aim of this study was to continue the research of Patrick J. Caroline and Mark P. Andre and to collect more information about the outcome of the technique. Methods Ten subjects with low myopia from -0.25 D to -1.25 D and a refractive astigmatism from plano to -0.75 D were fitted with a -10.00 D CIBA VISION AIR OPTIX® NIGHT&DAY® silicone hydrogel contact lens and were told to wear the lenses over night and everted. Corneal topography and refraction measurements were taken after one night, one week and one month of contact lens wear. Results Eight out of ten subjects finished the study, six female and two male. The mean age of the subjects was 23.9 years. With the eight subjects who finished the study, the mean change in subjective refraction was about +1.00 D in the sphere and +0.22 D in the cylinder, with maximum changes of +1.75 D sphere and +0.75 D cylinder. The mean apical power change, measured with the topographer, was 1.11 D. Changes in K - readings ranged from slight corneal steepening in both of the meridians to 0.23 mm of corneal flattening in the horizontal meridian and 0.27 mm of corneal flattening in the vertical meridian. Corneal eccentricity decreased about 0.65 on average. The main complaints and problems were the high minus power and the decentration of the contact lens and the occurrence of ghosting at night. Conclusion The results of this study show that everted wear of a high minus silicone hydrogel contact lens can lead to orthokeratology - such as changes in corneal topography and subjective refraction. These changes range from plano to +1.75 D sphere and +0.25 D to +0.75 D cylinder but are unpredictable and vary from subject to subject. Additional studies regarding the contact lens decentration and the unpredictability of the outcome need to be done to optimize the process.