Optik und Mechatronik
Refine
Year of publication
Document Type
- Bachelor Thesis (108)
- Master's Thesis (20)
- Report (3)
- Article (1)
Is part of the Bibliography
- no (132) (remove)
Keywords
- Abschlussarbeit (6)
- Augenoptik (5)
- Bachelorarbeit A/H (4)
- Leitfaden (4)
- Myopieprogression (3)
- Studie (3)
- Digitalisierung (2)
- FrACT (2)
- Gleitsichtgläser (2)
- Hörgerät (2)
- Hörsystem (2)
- Kinder (2)
- Kontaktlinse (2)
- Kreuzzylinder (2)
- Landoltring (2)
- Myopia (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- Studium (2)
- Umfrage (2)
- Visus (2)
- limbal sclera contour (2)
- vorderer Augenabschnitt (2)
- 3D-Druck (1)
- 3D-Refraktion (1)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Aalener Schnell Satztest (1)
- Aberrometer (1)
- Ablaufplan (1)
- Absolventen (1)
- Absolventenbefragung (1)
- Alvarezlinsen, Focusspec-Brille, Scheitelbrechwertmessung, Augendrehpunkt (1)
- App (1)
- Applikation (1)
- Atropin (1)
- Auditive und taktile Stimulation (1)
- Augenlänge (1)
- Augenmodell (1)
- Augenoptik-Branche (1)
- Augenoptikgeschäft (1)
- Augenoptikmarkt (1)
- Ausbildung (1)
- Bachelorarbeit A (1)
- Befragung (1)
- Behandlung, Kontaktlinsen, Presbyopie (1)
- Belastungsstörungen (1)
- Beratungsgespräch (1)
- Blinking (1)
- Blinzeln (1)
- Brillenfassung (1)
- Brillenfassung, UV-Durchlässigkeit (1)
- Brillenglaszentrierung (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- DNEye ® Scanner (1)
- Deflektometrie (1)
- Defocus (1)
- Dienstleistungsangebot (1)
- Diffusion (1)
- Dynamische Preise (1)
- EMDR-Behandlungen (1)
- ETDRS (1)
- ETDRS-Tafeln (1)
- Edge Detection (1)
- Erblindung (1)
- Eye Tracking, Vigilanz, Aufmerksamkeit, visuelle Exploration, Perimetrie (1)
- Eye tracking (1)
- Fixation (1)
- Gebrauchsstellung (1)
- Geschäftsmodell (1)
- Gleitsichtbrille (1)
- Grenzfrequenz (1)
- High-End-Hörsystem (1)
- Horn (1)
- Hörgerätverifikation (1)
- Hörqualität (1)
- Hörsysteme (1)
- Hörtraining (1)
- IOL Master 500 (1)
- Informationsbroschüre (1)
- Inter-Test Reliabilität (1)
- Internationalisierung (1)
- Jugendliche (1)
- Kameramessung (1)
- Kampimetrie (1)
- Kantendetektion (1)
- Kind (1)
- Kommunikationstraining (1)
- Kontaktlinsen (1)
- Kontaktlinsen-Service-System (1)
- Kontaktlinsensprechstunde (1)
- Kostenakzeptanz (1)
- Kreislaufwirtschaft (1)
- Kreuzzylinderabgleich (1)
- Kundengruppen (1)
- Kunststoff (1)
- LEA Symbole (1)
- Lehrmethoden (1)
- Lernsoftware (1)
- Lernvideo, Verkaufsgespräch (1)
- Lernvideo, e-Learning, Leitfaden (1)
- Leuchtdichte Homogenität (1)
- Leuchtdichte, Radiospektrometer, Kalibrierung, Spiegelreflexkamera (1)
- Leuchtdichteverteilung (1)
- Lions Club (1)
- Literaturübersicht (1)
- Low-End-Hörsystem (1)
- Marokko (1)
- Masterarbeit AO (1)
- Materialeigenschaften (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Messmethode (1)
- Messsystem (1)
- Messtechnik (1)
- Multifocal contact lenses (1)
- Multisensorische Integration (1)
- Musikinstrument (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Myopie-Management (1)
- Myopiekontrolle (1)
- Myopiemanagement (1)
- Nachhaltigkeit (1)
- Ohrmodell (1)
- Omnichannel (1)
- Onlineportal (1)
- Optical Engineering (1)
- Optometrie (1)
- Optometrist (1)
- Optotypen (1)
- Orthokeratologie (1)
- Perimetrie (1)
- Photopisches Sehen (1)
- Plusoptix (1)
- Preisfairness (1)
- Primary Eye Care Provider (1)
- Psychophysik (1)
- Qualifizierung (1)
- RCS (1)
- Refraktion (1)
- Refraktionsbestimmung (1)
- Retest-Reliabilität (1)
- Revenue-Management (1)
- Revenue-Marketing (1)
- Risikoanalyse (1)
- SNR-Verhältnis (1)
- Satztest (1)
- Scanpath (1)
- Schmalbandsignal (1)
- Schule (1)
- Schüler (1)
- Screening (1)
- Sehilfen (1)
- Sehschärfe (1)
- Six Sigma (1)
- Sphärisches Äquivalent (1)
- Sri Lanka (1)
- Strategie, Unternehmensführung, AMVO, VaKE (1)
- Streifenprojektion (1)
- Streifenprojektionsgerät (1)
- Studiengang Augenoptik (1)
- Störgeräusch (1)
- Tablet (1)
- Tieftonkompression (1)
- Tochter, Familienunternehmen, Nachfolge (1)
- Tolerance of blur, PAL`s, Astigmatism, Blurtest, Pretest (1)
- Traumatische Erinnerungen (1)
- Trockenes Auge (1)
- Tränenfilm (1)
- Unschärfetoleranz , Gleitsichtgläser, Astigmatismus , Blurtest, Pretest (1)
- Unverträglichkeit (1)
- Unzufriedenheit (1)
- Versorgungskapazität (1)
- Verzeichnung (1)
- Virtual reality (1)
- Virtuelle Realität (1)
- Visual acuity (1)
- Visual search (1)
- Visusbestimmung bei Kindern (1)
- Vorderkammertiefe (1)
- Weblog (1)
- Webportal (1)
- Webseite (1)
- Weiterbildung (1)
- Wiki (1)
- Workflow (1)
- Zufriedenheitsmessung (1)
- Zyklofusionstest (1)
- advanced training (1)
- albinism (1)
- auditive Wahrnehmung (1)
- augenoptischer Betrieb (1)
- automatical telephone audiometry, hearing aid fitting (1)
- automatisierter Telefonhörtest, Hörgeräteanpassung (1)
- berufliche Perspektiven (1)
- blindness (1)
- care capacity (1)
- customized (1)
- daughter, family enterprise, succession (1)
- demografischer Wandel (1)
- demographic change (1)
- digitales Endgerät (1)
- digitization (1)
- dry eye (1)
- erfolgreiches Geschäftsmodell, optometrische Dienstleistungen, Wettbewerb (1)
- eye tracking, vigilance, attention, cognitive workload, visual exploration, perimetry (1)
- genes (1)
- i.Profiler (1)
- individueller Inset (1)
- internationale Schwerhörigenhilfe (1)
- isochroner Rythmus (1)
- learning videos, e-learning, guideline (1)
- low vision (1)
- luminance distribution (1)
- luminance homogeneity (1)
- luminance, radio spectrometer, calibration, reflex-camera (1)
- measurement of the visual acuity in children (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- medical treatment, contact lens, presbyopia (1)
- melanin (1)
- monokulare Refraktionsbestimmung (1)
- multistabiler Rythmus (1)
- myopia management (1)
- optometric and optical companies (1)
- optometrische Dienstleistungen (1)
- peripheral myopic defocus (1)
- plusoptiX Binokular Autorefraktometer (1)
- proaktive Ansprache (1)
- psychophysics (1)
- qualification (1)
- repeatability (1)
- schwerhörige Erwachsene (1)
- schwerhörige Kinder (1)
- shortage of doctors (1)
- soft multifocal contact lens (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- strategy, management, AMVO, VaKE (1)
- successful business-model, optometrical service, competition (1)
- sustainability (1)
- tablet-basierte Applikation (1)
- tear film (1)
- two-rod test (1)
- vision therapy (1)
- visual acuity (1)
- weiche Kontaktlinsen (1)
- Ärztemangel (1)
Institute
- Optik und Mechatronik (132)
Feedback management in hearing aids and its challenges have been there for over 60 years. The basic principles of feedback management are still in use to prevent the hearing aids from oscillation. This work focusses on the feedback management in custom style hearing aids by comparing four different Invisible-In-the-Canal (IIC) hearing aids. Four test set-ups were created to find valid and reli-able methods and set-ups to test custom hearing aids for their feedback management. The goal was to find out if they could provide 1) stable gain, 2) good sound quality, 3) indicate specific frequencies audible feedback occurs and 4) to test the clinical robustness through subjective experience rating. The principle was: matched gain – matched acoustics.
Aalener Schnell Satztest
(2014)
Im Folgenden befasst sich die hier vorliegende Bachelorarbeit mit der Modifikation eines
deutschsprachigen Satztests, dem HSM-Satztest, in Anlehnung an den
angloamerikanischen Schnelltest QuickSIN™. Mit diesem daraus entwickelten „Aalener
Schnell Satztest“ (ASS) wird eine weitere Alternative zu dem OlSa und GöSa, nach den
geltenden HilfsM-RL, erzielt, welcher zugleich der Norm DIN ISO 8253-3:2009-06 gerecht
wird. Zu Beginn wurde der Umfang der 600 aufgesprochenen Sätze des HSM-Satztests
auf drei Signalwörter, bestückt aus einem Subjekt, einem Objekt und einem Adjektiv,
selektiert. Parallel dazu ist das Störsignal CCITT-Rauschen durch ein unverständliches
Sprachsignal (HSMnoise), erzeugt aus dem Sprachmaterial des HSM-Satztests, ersetzt
worden. Nach dieser Vorarbeit, wurden die 24 selektierten Sätze in einem
Signal-Rausch-Abstand (SNR) von 2 dB SNR-Schritten wieder zu einem komplett
modifizierten Satztest, genannt ASS, zusammengefügt. Die Diskriminationsfunktion des
veränderten Sprachmaterials, wurde dieser an 22 normalhörende Probanden getestet.
Gesucht war der Wert, bei dem 50 % der getesteten Worte verstanden worden sind
(L50-Wert), wobei das definierte Störgeräusch, das generierte HSMnoise, zur Anwendung
kam. Der unveränderte HSM-Satztest erreicht einen durchschnittlichen SNR von - 7,2 dB
mit einer Steilheit von 7,5 %/dB. Verglichen mit dem Aalener Schnell Satztest ergab sich
ein SNR in Höhe von - 5,3 dB mit einer Steilheit von 12,1 %/dB (Testliste 1) und
andernfalls ein SNR in Höhe von - 3,3 dB SNR mit einer Steigung von 11,2 % (Testliste 2).
Die Dauer der Durchführung lässt sich auf ein Zeitfenster, je nach Mitarbeit des
Probanden, von drei bis vier Minuten einkalkulieren. Zur Wahrung der Validität des
Aalener Schnell Satztests gilt es, im Rahmen eines aufbauenden Projekts, weitere
Satzgruppen anzuknüpfen.
Um den Unterricht abwechslungsreicher zu gestalten und die Effizienz des Lernens nachhaltig zu erhöhen, werden im Unterricht aktivierende Lehrmethoden eingesetzt. Diese sprechen mehrere Wahrnehmungskanäle an, durch die das Wissen von Lernenden aufgenommen und verarbeitet wird, wodurch die Erinnerbarkeit des Lehrstoffs erhöht wird. Die vorliegende Bachelorthesis setzt sich nun damit auseinander, welche Methoden in der augenoptischen Ausbildung eingesetzt werden können, um die Lernenden bei der Wissensaneignung zu unterstützen.
Aus einem vielfältigen Methodenpool werden hierzu diejenigen Methoden erläutert, die sich optimal für eine Verwendung im augenoptischen Unterricht eignen. Des Weiteren finden sich Erklärungen und Anwendungsbeispiele für die lebendige Wissensvermittlung mittels moderner Medien, wie zum Beispiel Tablets, Smartphones und Multi-Touch-Geräten. Der Schwerpunkt dieser Arbeit liegt auf der Verwendung von Apps und Hypervideos in der Ausbildung im Bereich Augenoptik beziehungsweise Optometrie. Es soll aufgezeigt werden, wie wichtig der Einsatz aktivierender Lehrmethoden im Unterricht ist und welche Vorteile diese für Lehrende und Lernende mit sich bringen. Hierfür werden allgemeine Anwendungsbeispiele aus der Literatur aufgezeigt, sowie durch eigens hergestellte, auf die Optometrie und Augenoptik abgestimmte aktivierende Elemente Anregungen und Anwendungsbeispiele für den augenoptischen Unterricht gegeben. Darüber hinaus wird ein Ausblick auf die zukünftige Entwicklung lebendiger Unterrichtsmethoden in der Augenoptik aufgezeigt.
Dabei ergibt sich, dass die Einbettung lebendiger Wissensvermittlung in den Unterricht unter anderem eine Zeitersparnis für Lehrende und Lernende darstellt und dem Unterricht Spaß und Abwechslungsreichtum verleiht, wodurch die Lernatmosphäre und die Motivation der Lernenden erhöht wird. Außerdem werden durch aktivierende Lehrmethoden neben den fachlichen Kenntnissen Schlüsselkompetenzen wie die Teamfähigkeit, das Zeitmanagement und die
Problemlösefähigkeit vermittelt, wodurch sich das Lernen mittels dieser Methoden als vielfältiger erweist.
Die Bevölkerungsversorgung mit medizinischen Leistungen stellt zunehmend eine größere Herausforderung dar. Durch demographische Veränderungen unserer Gesellschaft ist ein deutlicher Anstieg des augenärztlichen Versorgungsbedarfs erkennbar. Trotz steigender Zahl an Ophthalmologen zeigt sich keine entsprechende Zunahme der augenärztlichen Versorgungskapazität. In der Zukunft wird eine flächendeckende und hochqualitative Versorgung nicht mehr möglich sein, solange nicht mit Aufstockung der notwendigen Ressourcen auf den steigenden Versorgungsbedarf reagiert wird.
Ziel dieser Bachelorarbeit ist es ein Kontaktlinsenwiki aufzubauen, welches als Nachschlagewerk rund um das Thema Kontaktlinse dienen soll. Hierzu wird zunächst ein Inhaltsverzeichnis auf der Hauptseite des Wikis eingefügt, anhand dessen die Studierenden des Studiengangs Augenoptik der Hochschule Aalen die Inhalte erstellen.
Das Wiki wird mittels der MediaWiki-Software der Version
1.23.15 erstellt, welche auf einer externen Festplatte mit dem Betriebssystem Ubuntu Linux 12.04 vorliegt.
Im Rahmen einer Umfrage wird untersucht, inwiefern das Kontaktlinsenwiki ein Zukunftspotenzial hat, sowie wie benutzerfreundlich das erstellte Konzept ist.
Dabei haben die Umfrageergebnisse bestätigt,dass seitens der Studierenden ein Interesse besteht das Wiki nicht nur passiv zu nutzen, sondern es auch aktiv weiterzuentwickeln.
Auch in Bezug auf die Benutzerfreundlichkeit wird
das Wiki positiv bewertet.
Insgesamt besteht das Kontaktlinsenwiki aus zwölf
Artikeln, an denen 50 Studierenden des Studiengangs Augenoptik aktiv mitgearbeitet haben.
Das Wiki kann sowohl für Studierende als auch für Interessierte, als nützliches Nachschlagewerk dienen.
Ziele: Heutzutage leiden immer mehr Menschen an einer Lärmschwerhörigkeit. Als eine mögliche Ursache dafür wird unter anderem zu lautes Musikhören in Betracht gezogen und daher oft diskutiert. Ziel der vorliegenden Bachelorarbeit war es, zu untersuchen, ob Probanden mit Noise Cancelling Kopfhörern eine leisere Ausgangspegeleinstellung wählen als mit Standard Kopfhörern. Hierzu wurden verschiedene Kopfhörervarianten mit unterschiedlichen Umgebungsgeräuschen kombiniert und deren Auswirkung auf den bevorzugten Lautstärkepegel geprüft. Es wurde die These aufgestellt, dass mit Noise Cancelling Kopfhörern leiser Musik gehört wird und dass dies von den Umgebungsgeräuschen abhängt. Aus den gemessenen Pegeln wurde die zulässige Hördauer berechnet, mit der die maximale Tageslärmdosis erreicht wird. Material und Methoden: Die21 Probanden, die an der Studie teilnahmen, sollten Musik in Umgebungslärm hören und dabei ihren bevorzugten Lautstärkepegel einstellen. Genutzt wurden Over-Ear Kopfhörer mit und ohne Noise Cancelling Funktion. Neben den drei eingesetzten Geräuschumgebungen wurde zum Ver-gleich zusätzlich in Ruhe gemessen. Die Messungen erfolgten mit zwei verschiedenen Musikrichtungen. In einem Fragebogen wurde das subjektive Empfinden der Probanden abgefragt. Ergebnisse: Die Resultatezeigen, dass essignifikante Unterschiede in der Ausgangspegeleinstellung zwischen den Kopfhörermodellen gab. Mit den Noise Cancelling Kopfhörern wurden in den Umgebungsgeräuschen Pegel gewählt, die im Durchschnitt ca. 8,9 dB(A) leiser waren als mit normalen Kopfhörern. In Ruhe ergaben sich nur geringe Unterschiede zwischen den Kopfhörermodellen. Fazit: Die Probanden haben mit Noise Cancelling Kopfhörern im Vergleich zu normalen Kopfhörern leisere Ausgangspegel zum Hören von Musik bevorzugt. Nur Wenige haben mit ihren bevorzugten Pegeln die maximale Tageslärmdosis erreicht. Allgemein waren die gewählten Pegel unbedenklicher als erwartet und stellen vermutlich ein geringes Risiko für Hörschäden dar.
In dieser Arbeit wurden zwei verschiedene Beratungsintensitäten bei gleichbleibendem Produkt miteinander verglichen. Diese wurden als Premium-und als Standardanpassung bezeichnet.
Die Hörgeschädigtennahmen an einer Blindstu-die teil, bei der sie glaubten sie testeten zwei unterschiedliche Hörsysteme, die sich jeweils in der Intensität der Anpassungsmethode unterschieden. Es handelte sich jedoch bei beiden Anpassungsverfahren bzw. Beratungsmethoden um dasselbe Hörsystem.
Nach der ersten sowie nach der zweiten Anpassung wurde den jeweiligen Probanden ein Fragebogen ausgehändigt, dessen Inhalt identisch war. Hierbei sollte durch ein Punktesystem auf einer visuellen Analogskala die Zufriedenheit der einzelnen Hörsituationen mit dem Hörsystem sowie die Zufriedenheit der Beratung/Anpassung in beiden Anpassungssituationen bewertet werden.
Es sollte herausgefunden werden, ob sich der Mehraufwand auf die Zufriedenheit auswirkt und ob damit letztendlich qualitativ hochwertigere Hörsysteme verkauft werden könnten. Würde die Zufriedenheit eines Produktes allein durch eine zeitaufwendigere Anpassung zunehmen, so könnte man während der Testphase gezielt mehr auf Komfort-oder Premiumgeräte zurückgreifen. Durch eine damit einhergehende Steigerung der Zufriedenheit beim Kunden würde auf Dauer somit eine Umsatzsteigerung durch einen geringen zeitlichen Mehraufwand einhergehen. Mit den erfahrenen Hörsystemträgern sollte eine ungefähr einheitliche Basis der Probanden geschaffen werden.
Um zu vermeiden, dass Hörerfahrungen während der Testphase völlig neu für die Probanden sind und der Fokus ggf. ausschließlich auf dem Umgang und den ersten neuen Höreindrücken mit dem Hörsystem liegt. Durch die jahrelange Erfahrung mit den eigenen Hörsystemen konnten folglich gezielt die jeweiligen Hörsituationen bewertet werden.
Es wurde somit versucht, eine Eingewöhnungszeit sowie der grundlegend neue Umgang und die neue Klangwelt möglichst zu minimieren.
Das Ziel dieser Bachelorarbeit ist es, die Auswirkungen, welche Lösungsmittel auf die Brillenfassungen aus Kunststoff haben können, untereinander zu vergleichen.
Im ersten Teil der Arbeit werden Grundlagen zu verschiedenen Brillenkunst-stoffen und Lösungsmitteln aufgeführt. Außerdem werden Prüftechniken der allgemeinen Kunststofftechnik beschrieben, die die Beständigkeit eines Kunststoffmaterials auf ein chemisches Medium untersuchen.
Im zweiten Teil dieser Bachelorthesis wird ein Versuch durchgeführt, der die Auswirkungen der Lösungsmittel Aceton, Ethanol, Isopropanol und Benzin auf verschiedene Kunststofffassungen aus Zelluloseacetat und Polyamid vergleicht. Dafür müssen im Vorfeld die zu untersuchenden Kunststofffassungen ausgewählt und die Lösungsmittel festgelegt werden. Bei der Versuchsdurchführung wird Wert auf ein praxisnahes Auftragen der Lösungsmittelmenge gelegt.
Die Ergebnisse der Untersuchung zeigen vor allem, dass nicht alle verwendeten Lösungsmittel schädliche Veränderungen an den Materialoberflächen auslösen.
Die Lösungsmittel Benzin, Ethanol und Isopropanol sind als Reinigungsmittel bekannt.
Sie zeigen bei diesem Kurzzeitversuch überwiegend positive Veränderungen bezüglich der Materialoberfläche. Während Benzin größtenteils keine Veränderungen zeigt, weisen Ethanol und Isopropanol polierende Effekte auf. Jedoch zeigt Ethanol in diesem Versuch an den Polyamidfassungen auch oberflächenmattierende Auswirkungen. Daher gilt als Ergebnis festzuhalten, dass das Reinigungsmittel mit der schonensten und mit einer polierenden Wirkung Isopropanol ist und in dieser Hinsicht Ethanol auch ersetzen könnte.
Neben den Auswirkungen der Lösungsmittel, soll die Notwendigkeit einer guten Materialkunde des Augenoptikers verdeutlicht werden.
Einleitung:
Die vorliegende Studie befasst sich mit dem Thema „Barrierefreiheit“ für Menschen mit einer Hörschädigung. Das Ziel dieser Arbeit ist, zu analysieren, ob die Chance auf eine gleichberechtigte Teilhabe am Leben von hörbeeinträchtigten Personen besteht, und ob ein Unterschied im Grad der Barrierefreiheit zwischen den Teilnehmern aus dem Ostalbkreis und Deutschland festzustellen ist.
Material und Methoden:
Es wurde jeweils ein Fragebogen für schwerhörige (22 Fragen) und gehörlose Personen (20 Fragen) erstellt. Verteilt wurden die Fragebögen in Aalen und Schwäbisch Gmünd. Deutschlandweit hatten alle hörbeeinträchtigten Menschen die Möglichkeit, auf einem Online-Portal teilzunehmen. Der Austausch zur Befragung der Stadt Aalen nach barrierefreien Einrichtungen fand per E-Mail statt.
Ergebnisse:
Der Grad der Barrierefreiheit im Ostalbkreis und Deutschland weist keine signifikanten Unterschiede auf. Der Vergleich zwischen Gehörlosen und Schwerhörigen zeigte auf, dass insbesondere im Berufsleben die Schwerhörigen auf weniger Hindernisse trafen als die Gehörlosen. Das Thema „barrierefreie Medien“ und die fehlende Ausstattung von technischen Höranlagen in Einrichtungen machte die Unzufriedenheit auf beiden Seiten deutlich. Bei der Gegenüberstellung von gehörlosen Schülern und Erwachsenen kam zum Vorschein, dass die Schüler mit ihrer Taubheit besser zurechtkamen als die Erwachsenen. Barrierefreie Einrichtungen waren in er Stadt Aalen kaum zu finden.
Diskussion:
Die Ergebnisse zeigen, dass Handlungsbedarf im Ostalbkreis sowie in ganz Deutschland zum Thema“ Barrierefreiheit“ für hörgeschädigte Menschen besteht. Dies gilt insbesondere für die Bereiche Medien, Bildungsstätten, Arbeitsplätze sowie die Teilhabe am öffentlichen Leben.
Schlussfolgerungen:
Ein barrierefreies Leben in den Bereichen Bildung, Beruf/Arbeit und Teilhabe am öffentlichen Leben im Ostalbkreis und ganz Deutschland ist noch nicht möglich.
Das Ziel dieser Thesis ist es, eine UV-durchlässige Brillenfassung zu entwi-ckeln, welche aus kosmetischen Gründen zur Reduktion des Bräunungsabdrucks getragen wird. Hierfür wurde mithilfe einer Online-Umfrage eine Bedarfsanalyse durchgeführt.
Um eine solche Studie durchführen zu können, werden die notwendigen theoretischen und produktionspraktischen Vorüberlegungen angestellt. Im ersten Teil der Arbeit wird zunächst darauf eingegangen in welchen Branchen UV-durchlässige Materialien zum Einsatz kommen. Wichtige Ergebnisse können aus dem Bereich der Textilindustrie und dem Solarienbau gewonnen werden. Es stellt sich heraus, dass beispielsweise das Material Plexiglas® GS Sunactive der Firma Evonik Industries, für den Bau eines Prototyps geeignet sein kann.
Ein zentrales Ergebnis der durchgeführten Umfrage ist, dass 56 % der Befragten den Bräunungsabdruck ihrer Korrektionsbrille als störend empfinden. Frauen stört dieser signifikant stärker als Männer. Ein deutlich größerer Anteil der Befragten empfindet den Bräunungsabdruck ihrer Sonnenbrille als störend. Eine weitere wichtige Erkenntnis ist, dass weniger Befragte ihre Sonnenbrille zum Bräunen absetzen würden, hinterließe sie keinen Bräunungsabdruck. Dies würde zum Schutz der Augen beitragen. Insgesamt hätten 70 % der Befragten, Interesse an einer UV-durchlässigen Brillenfassung und wären auch bereit, hier einen höheren Preis zu bezahlen, als für eine handelsübliche Brillenfassung.
Beim Bau des Prototyps müssen einige DIN-Normen beachtet werden. Das verwendete Material darf die Gesundheit und Sicherheit des Trägers nicht beeinflussen. Die Augen müssen vor schädlichen UV-Strahlen geschützt werden, weshalb die Gläser weiterhin mit UV-Schutz ausgestattet sein müssten. Der fertige Prototyp muss ferner eine angemessene mechanische Stabilität und Temperaturbeständigkeit aufweisen.
Der fertige Prototyp zeigt, dass es möglich ist, eine UV-durchlässige Brillenfas-sung, die eine ausreichend mechanische Stabilität und Temperaturbeständigkeit hat, zu entwickeln und zu produzieren. Wie die Umfrage gezeigt hat, gibt es Interessenten und somit eine potentielle Nachfragesituation für eine derartige Produktneuheit; auf den im Zusammenhang mit dieser Arbeit gefertigten Prototypen wird im Verlauf der Arbeit näher eingegangen.
„Gelernt ist längst nicht mehr gelernt”- Weiterbildung und Qualifizierung sind der Schlüssel für die Arbeit von morgen, erklärte Bundesarbeitsminister Hubertus Heil am 21.11.2019. „Die Beschäftigten von heute müssen auch die Arbeit von morgen machen können”, lautete der zentrale Satz, mit dem Hubertus Heil den Grundstein für die Debatte legte. Durch den digitalen Wandel der Arbeitswelt werden sich Berufe, Tätigkeiten und Qualifikationsprofile massiv verändern. „Lebenslanges Lernen” dürfe dabei aber nicht als Bedrohung wahrgenommen werden. (1) Um das Wissen und Können auf dem neuesten technologischen Stand zu halten, wird Weiterbildung immer wichtiger, nicht nur für Geringqualifizierte, sondern auch für Fachkräfte. (2) Moderne Geräte führen heute für den*die Kunden*Kundin unterschiedliche Screenings durch und messen zeitgleich die Sehstärke unter Tag- und Nachtbedingungen. Tragbare Funduskameras ermöglichen ohne Pupillenerweiterung das Erkennen und Überwachen von Netzhauterkrankungen. (3) All diese Geräte sind einfach und ohne besondere Qualifikation zu bedienen. Trotz der zunehmenden telemedizinischen Unterstützung ist eine fundierte optometrische Ausbildung unentbehrlich um sich nicht von dieser telemedizinischen Unterstützung abhängig zu machen oder noch bedenklicher, den*die Kunden*Kundin mit Halbwissen vermeintliche Sicherheit über seinen*ihren Gesundheitszustand zu vermitteln. Auch befinden wir uns mitten im demografischen Wandel. Die steigende Zahl älterer Menschen bedeutet nicht nur ein Anstieg von Brillenträgern, sondern auch eine Zunahme an altersbedingten Veränderungen am Auge. (4) Gleichzeitig nimmt die Zahl der Augenärzte stetig ab, ab von den großen Städten herrscht in der Augenheilkunde ein großer Ärztemangel. (5) Der*die Augenoptiker*in Zukunft wird zunehmend in den Bereich Früherkennung und Prävention miteinbezogen. Dazu benötigt er*sie entsprechende Kenntnisse und Qualifikationen eines*einer Optometristen*in, um diese optometrischen Dienstleistungen anbieten zu können. Die zunehmende Digitalisierung ermöglicht zusätzlich nützliche persönliche und kompetente Beratung auf hohen fachlichen Niveau. Diese Masterthesis gibt einen Überblick über die aktuelle Ausbildungssituation und welche berufsbegleitenden Weiterbildungsmöglichkeiten für Augenoptikergesellen*innen, Augenoptikermeister*innen, Staatlich geprüfte Augenoptiker*innen und Dipl.-Ing. für Augenoptik (FH) in Deutschland zur Verfügung stehen.
Ziel:
Ziel dieser Arbeit war die Erstellung eines Kriteriums, das die positionelle Zuverlässigkeit der Angaben eines Probanden bei Gesichtsfeldmessungen quantifiziert, mittels automatischer, schwellenbestimmender Rasterperimetrie, anhand von Baseline-Untersuchungen.
Material und Methoden:
Verwendet wurden jeweils die drei Baseline-Untersuchungen der X-SCOPE-Studie und der TRASCO-Studie(beide befassten sich mit dem Vergleich fixer und adaptiver Prüfpunktraster).
Beide verwendeten die schnelle Schwellenstrategie „german adaptive threshold estimation“ (GATE) zur Untersuchung von Offenwinkelglaukomen (Aulhorn-Stadien I–III), mit dem OCTOPUS 101 Perimeter (Haag-Streit AG, Köniz, Schweiz). Skotome wurden anhand von Wahrscheinlichkeitskarten definiert, in Anlehnung an die von Katz et al. (1991) und Martínez und Sánchez (2008) verwendeten Kriterien zur Skotomdefinition. Die Baseline-Untersuchungen waren für jeden Probanden innerhalb eines Monats geplant.
Bei der Auswertung der Gesichtsfeldbefunde wurde der Positionsbezogene Skotom-Übereinstimmungs-Index (PSÜI) als neuer Parameter zur Beurteilung der Schwankung von Probanden definiert.
Dieser wurde aus dem Quotienten von Vereinigungs- und Schnittmenge der Skotome gebildet und mit dem mittleren Defekt (MD), der sog. „short-term fluctuation“ (SF), den FP-Fangfragen (FP), den FN-Fangfragen (FN) und der Fixationsfehlerrate (Fix) verglichen.
Circa 15% der Einwohner in Marokko leben unterhalb der Armutsgrenze. Eine gute medizinische Versorgung und die Versorgung mit Sehhilfen sind nicht gewährleistet. Bisher gibt es nur wenig Zusammenarbeit zwischen Marokko und Deutschland bezüglich Sehhilfen. Im Rahmen der vorliegenden Bachelorarbeit ist eine Zusammenarbeit zwischen den marokkanischen und deutschen Vereinen an drei Orten zustande gekommen. Diese Arbeit wird auf langfristige Basis eingeführt und drei Termine sind bereits für das kommende Jahr 2016 vereinbart. Es wurde untersucht, welche Form der Unterstützung für eine bessere Versorgung von Sehhilfen für die arme Landbevölkerung von Marokko geeignet wäre, wie man das am besten realisieren könnte und welche Stärken bei den Sehhilfen erforderlich sind.
Zur Bestimmung der benötigten Stärken der Sehhilfen wurden 180 Patienten in drei verschiedenen Orten in Südmarokko untersucht. In der Untersuchung wird die Sehschärfe mit und ohne Korrektion überprüft. Zudem wurden Kontakte zu verschiedenen Hilfsorganisationen geknüpft und bewertet.
Die Ergebnisse dieser Studie zeigen, dass es in der marokkanischen Landbevölkerung teilweise zu sehr hoher Fehlsichtigkeit kommt, die zu selten oder zu spät mit Sehhilfen korrigiert werden.
Nicht nur an diesen drei Orten, sondern überall, insbesondere in den Dörfern auf dem Land. Deswegen gibt es viele andere Stellen an denen die Menschen mit Sehhilfen versorgt werden können.
Biometrie des Auges
(2020)
Das Ziel dieser Studie besteht darin, 200 Probanden an den Zeiss-Geräten i.Profiler und IOL Maser 500 zu vermessen, um ein individuelles Augenmodel überprüfen zu können.
Zusätzlich wird untersucht wie das Sphärische Äquivalent (SÄ) der Probanden, mit der jeweiligen Augenlänge und der Vorderkammertiefe korreliert. Die Messungen der zufällig ausgewählten Probanden erfolgten immer am rechten Auge zwischen 9:00 und 15:00 Uhr.
Angesichts knapper werdender Finanzmittel und der Erhaltung und Förderung von gesellschaftlicher Akzeptanz für Entwicklungsprojekte, ist deren nachhaltige Wirksamkeit von zentralem Interesse. Zur Beurteilung des Erfolgs von Entwicklungszusammenarbeit hat der Ausschuss für Entwicklungshilfe der OECD internationale Evaluationskriterien geschaffen.
Ziel der Arbeit ist es, das gemeinsame Schwerhörigenhilfsprojekt vom Lions Club Kelkheim und Lions Club Anuradhapura „Hilfe für kleine Ohren“ in Sri Lanka vorzustellen und seine bislang erreichte Wirkung bezüglich seiner Zielsetzung zur nachhaltigen Entwicklung zu analysieren und gegebenenfalls Optimierungsmöglichkeiten für zukünftige Entscheidungsprozesse zu formulieren.
Die Evaluierung berücksichtigt die Rahmenbedingungen des Projekts und basiert auf der Auswertung einer Umfrage zum Anpasserfolg von Hörgeräten durch lokale Mitarbeiter. Zusätzlich werden die Patientendaten und die Ausbildung der lokalen Mitarbeiter zur Beratung und Anpassung von Hörgeräten analysiert.
Das Ergebnis der Diskussion zeigen, dass in mehreren Bereichen Erfolge zu verzeichnen sind. Insbesondere in der Relevanz und der Effizienz der Entwicklungsmaßnahme. Sie tragen zu den kurzfristigen und teilweise auch zu den langfristigen Projektzielen bei. Dabei wird speziell die Verbesserung der Situation für die Schwerhörigen und die finanzielle und personelle Unabhängigkeit des Projekts angestrebt. Doch es zeigen sich auch Schwächen die das langfristige Fortbestehen des Projekts gefährden und die Effektivität der Maßnahme beschränken.
Zusammenfassend lässt sich festhalten, dass das Projekt „Hilfe für kleine Ohren“ in Sri Lanka noch am Anfang steht. Es ist zwar ein solider Grundstein gelegt, dennoch werden weitere Unterstützungsmaßnahmen zur Verbesserung der Schwerhörigenversorgung und deren langfristigen Wirksamkeit notwendig sein. Dabei handelt es sich unter anderem um die Ausbildung weiterer lokaler Mitarbeiter in der Versorgung mit Hörhilfen. Diese könnten in regelmäßigen Abständen durch freiwillige Hörakustiker oder Hörakustik-Studenten im Rahmen ihres Studiums und unter Einbeziehung lokalen Fachpersonals zusätzlich unterstützt werden.
Ziel dieser Arbeit ist es, das Zielgruppenmodell Roper Consumer Styles (RCS)
der Gesellschaft für Konsumforschung (GfK) genau zu beschreiben und dessen
Anwendbarkeit auf die Augenoptik zu prüfen.
Zu Beginn werden die Geschichte und Entwicklung der Roper Consumer Styles
(RCS) sowie das Modell selbst und seine einzelnen Lebensstile erläutert. Im
zweiten Teil setzt sich diese Arbeit mit der Anwendung der Roper Consumer
Styles (RCS) in der Augenoptik auseinander. Es wird ein Pilotprojekt vom
Zentralverband der Augenoptiker (ZVA) und der Gesellschaft für Konsumforschung
(GfK) vorgestellt. Die Gesellschaft für Konsumforschung (GfK) bestimmt
das Einzugsgebiet des Optikers, analysiert die Kundschaft in dem Gebiet und
zeigt auf, bei welchen Zielgruppen noch Potenzial besteht. Der Optiker bekommt
von der Gesellschaft für Konsumforschung (GfK) konkrete Empfehlungen,
welche Marken und welche Designs die gewünschten Zielgruppen ansprechen.
Es ergeben sich vier Bereiche, in denen die Roper Consumer Styles (RCS) in
der Augenoptik angewandt werden können: Produkt/Sortimentspolitik, Preispolitik,
Kommunikationspolitik und Ladenbau/Schaufenstergestaltung. Anschließend
wird das Projekt einer kritischen Würdigung unterzogen. Dabei werden zwei
Verbesserungsvorschläge vorgebracht. Ein Vorschlag ist, die Fassungen nicht
nach Marken, sondern nach den Styles zu unterscheiden und eine Klassifizierung
der Fassungen nach den Roper Consumer Styles (RCS) zu machen. Der
andere Vorschlag ist, ein Kurzfragebogen zu entwickeln, der eine direkte
Einordnung des einzelnen Kunden nach den Roper Consumer Styles (RCS)
ermöglicht. Abschließend wurde eine Umfrage unter den Betrieben, die am
Projekt teilgenommen haben, durchgeführt. Die Ergebnisse der Umfrage zeigen,
dass das Zielgruppenmodell Roper Consumer Styles (RCS) in der Augenoptik
Anwendung findet und von den Optikern selbst auch als positiv bewertet wird.
Aus diesem Grund soll die Analyse der Gesellschaft für Konsumforschung (GfK)
in Zukunft für einen größeren Kreis von Betrieben angeboten werden.
Hörsysteme der heutigen Zeit bieten die Möglichkeit Situationen der Hörumgebung zu erkennen und zu klassifizieren. Dadurch ist es dem Hörgeräteakustiker möglich nachzuvollziehen, wann, wie lange und in welcher Situation sein Kunde die Hörgeräte getragen hat. Oftmals kommt es jedoch zu dem Fall, dass die Aufzeichnung der Geräte von den Aussagen des Kunden abweichen. Somit stellt
sich die Frage, ob und wann es zu Komplikationen in der Aufzeichnung des Trageverhaltens kommen kann.
Ziel der vorliegenden Arbeit ist es, die Zuverlässigkeit des Data Loggings und die Faktoren, die diese beeinträchtigen können zu untersuchen.
Es wird ein Vergleich von drei Herstellern in Bezug auf die Dokumentation der Tragedauer und der Situationserkennung angestellt. Für die Situationserkennung werden mit
Hilfe eines Lautsprecherkreises während einer 3- und 8-Stunden-Messung die Situationen „Sprache in Ruhe“, „Sprache im Störgeräusch“ und „Musik“, während einer 2-Stunden-Messung ein „Bar-Szenario“ konstruiert.
Das Ergebnis der vorliegenden Studie zeigt, dass die Tragedauer sehr zuverlässig aufgezeichnet, die Hörumgebung hingegen je nach Situation besser und schlechter erfasst wird. Besonders deutlich wird im Verlauf der Arbeit ebenfalls der Einfluss der binauralen Synchronisation, welche gerade im Bereich der Musik-Erkennung einen wesentlichen Beitrag leistet.
Deflektometrie
(2015)
In der vorliegenden Bachelorarbeit wurde ein, im Zentrum für Optische Technologien neuartiger Aufbau, eingemessen, sowie eine Anleitung für diesen erstellt. Dieser Messaufbau basiert auf Deflektometrie. Es werden Messungen mit diesem Gerät durchgeführt. Für Vergleichsmessungen wir ein Interferometer (ALI 201) verwendet.
Es wird der aktuelle Stand der Technik in der Interferometrie und der Deflekto-metrie erklärt. Hierbei wird auch auf die allgemeine Funktionsweise beider Messtechniken eingegangen.
Anschließend werden die bei den Versuchsmessungen verwendeten Geräte allgemein erläutert. Das heißt der Aufbau und die Funktion eines Fizeau-Interferometers und eines Phase-Measuring-Deflektometers.
Außerdem wurde eine Bedienungsanleitung für das Deflektometer mit einem LED-Tunnel erstellt, welches ein Entwicklungsgerät von Zeiss ist. Schließlich werden Flächen mit verschiedenen Oberflächenstrukturen mit den Messgeräten ausgemessen. Die Messwerte mit dem Interferometer sollen als Vergleichswerte dienen, damit man die Messungen am Deflektometer bewerten und einschätzen kann. Es geht vor allem darum, zu sehen, welche Oberflächen mit dem Deflektometer produktiv vermessen werden können. Außerdem soll bei geeigneten Oberflächen die Wiederholbarkeit des Geräts anhand von 20 Wiederholungsmessungen getestet werden.
Zielsetzung: Die Wahrnehmung des Menschen ist sehr vielfältig und noch nicht vollständig erforscht. Durch die Individualität und Einzigartigkeit des Menschen zusammen mit einer komplexen Gehirnleistung, welche noch unerforschte Lücken aufweist, stößt man immer wieder auf neue Strukturen. Eine bekannte ist der Wahrnehmungswechsel bei Kippbildern, die durch multistabile Stimuli verursacht werden. Überträgt man dieses Prinzip von der Optik auf die Akustik, führt es zum Ziel dieser Bachelorarbeit: Die Arbeit untersucht, ob Musiker beim Hören von multistabilen, isochronen Rhythmen bei deren Detektion einen Vorteil vor Nichtmusikern haben.
Methode:
Für die Messungen wird ein isochroner Rhythmus erstellt, den 40 Probanden –20 Musiker und 20 Nichtmusiker – hinsichtlich der Wahrnehmung von verschiedenen Rhythmusvarianten beurteilen. Dabei wird jeder wahrgenommene Variantenwechsel protokolliert und anschließend auf mögliche Abhängigkeiten und Einflüsse getestet.
Ergebnis:
Die Ergebnisse belegten, dass die musikalischen Probanden einen Vorteil vor den Probanden ohne musikalische Erfahrung haben. Die Musiker können schneller, öfter und überhaupt den Wechsel der Rhythmusvarianten wahrnehmen. Dabei ist es unerheblich, in welchem Alter der Musikunterricht begonnen wurde, ob immer noch aktiv musiziert wird, wie lang musiziert wurde oder welches Geschlecht die Probanden haben.
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.
Fragestellung: Ist es sinnvoll im Kindesalter restriktiv einen UV-Schutz für die Augen anzuwenden, obwohl UV-Strahlung eine schützende Wirkung für das Entstehen einer Myopie hat?
Einleitung: Die Myopie ist eine typischerweise durch Längenwachstum des Augapfels verursachte Fehlsichtigkeit mit stark steigender Prävalenz in den letzten Jahrzenten. UV-Strahlung hat auf die Haut und die Augen eine Vielzahl negativer Auswirkungen. Nebst der akuten Photokeratitis sind Pinguecula, Pterygium, Plattenepithelneoplasie, Katarakt, AMD und maligne Melanome chronische Veränderungen. Andererseits bremst UV-Strahlung das Fortschreiten des Augenlängenwachstums.
Modellrechnung: Mittels dem evidenzbasierten Modellrechner kann das Risiko einer Myopie und deren Stärke anhand des Jahrgangs, der Sonnenschutzanwendung, der familiären Prädisposition, der Zeit im Freien und des Bildungsgrades berechnet werden. Gelegentlich angewandter Sonnenschutz hat gegenüber häufig angewandtem Sonnenschutz einen Schutzfaktor für die Myopieentstehung von 1.03. Das grösste Risiko einer Myopie kommt von der familiären Prädisposition.
Diskussion: Zeit im Freien hat einen grossen hemmenden Effekt auf die Myopie, Sonnenschutzanwendung nur einen leicht Fördernden. Zudem hat Sonnenschutz einen stark hemmenden Effekt auf UV-bedingte Augen- und Hauterkrankungen. Auf Sonnenschutz der Augen zu verzichten, um eine Myopie zu verhindern oder im Fortschreiten zu bremsen, scheint unvernünftig.
Die Virtual Reality Brillen Technik und ihre Nutzungsmöglichkeiten in der Augenoptik und Optometrie
(2019)
Das Ziel der vorliegenden Bachelorarbeit ist es, einen Überblick über die Einsätze der Virtual Reality Brillen Technik in der Augenoptik und Optometrie zu geben und
gleichzeitig auch auf die Technik hinter der Virtual Reality Brillen einzugehen.
Hierzu werden zu Beginn die Arten und Funktionsweisen der unterschiedlichen Geräte auf dem Markt vorgestellt und miteinander verglichen. Anschließend werden Problematiken bei der Verwendung von Virtual Reality Brillen diskutiert. Die Basis der Arbeit bildet die Darstellung und Aufführung von bereits erfolgreichen Einsätzender Virtual Reality Brillen in der Augenoptikbranche, sowie die Vorstellung von gelungenen Einsätzen der Technik in Studien, hinsichtlich therapeutischer Maßnahmen in der Optometrie.
Ableitend daraus werden eigene Nutzungsmöglichkeiten erarbeitet, die als Ideen und Denkanstöße für zukünftige Virtual Reality Anwendungen in der Augenoptik, dienen sollen.
In dieser Arbeit wird speziell nur auf die Technik der Virtual Reality Brillen und nicht auf die gesamte Virtual Reality Technik eingegangen.
Die Bachelorarbeit ist sowohl für Schüler und Studierende in der Augenoptik, als auch für alle Interessenten des augenoptischen Fachgebietes interessant. Alle aufgeführten Einsätze entsprechen dem aktuellen Stand 2018.
Ziel dieser Bachelorthesis „Digitalisierung in der Augenoptik: Konzeption eines Online-portals“ stellt einen Leitfaden zur Umsetzung einer erfolgreichen Website für stationäre augenoptische Fachgeschäfte dar. In diesem Zusammenhang wird ein Glossar zu augenoptischen Begriffen erarbeitet, welches in einem Onlineportal integriert werden kann.
Zuerst werden Grundlagen zur Entwicklung und Nutzung des Internets, zur Einbindung in das Marketingkonzept, zu Aufmerksamkeits- und Denkprozessen des Menschen, sowie zur Kommunikation dargelegt. Abschließend wird auf die sich ergebenden Chancen für Optikergeschäfte eingegangen.
Im Kernteil der Arbeit wird ein Konzept erarbeitet, welches Analysen, Strategie- und Zielsetzung, Konzeptideen, die Umsetzung und das Controlling beinhaltet. Darauffolgend ist eine zusammenfassende Checkliste aufgeführt. Diese Anleitung garantiert ein erfolgreiches Webportal.
Um den potenziellen Kunden innerhalb der Website auf den anstehenden Kauf vorzubereiten oder sich über ein spezielles Thema informieren zu können, ist ein Glossar zu den wichtigsten Begriffen der Augenoptik aufgeführt. In diesem Verzeichnis sind 42 Elemente erklärt. Durch die Integration auf der Website verschafft sich das Unternehmen einen Expertenstatus. Das Glossar kann und soll nach der Thesis vervollständigt werden und durch Videos visualisiert werden.
The use of computers spread among the population, both for work and leisure purposes. This poses an increased risk factor for dry eye disease, a multifactorial disease influencing the surface of the eye. With the recent increasing usage of head-mounted displays, it is critical to determine whether or not they have the same impact on the tear film as conventional screens.
Die vorliegende Bachelorarbeit dient der Vermittlung der Grundlagen der Hörakustikbranche und einem darauf basierenden Kalkulationsverfahren für die Praxis, abgestimmt auf die Lehrveranstaltungen der Studierenden des Studiengangs Hörakustik/Audiologie der Hochschule Aalen. Beide Punkte sind unerlässlich für eine erfolgreiche Unternehmensführung. Motivation für diese Thesis war, dass es kaum Literatur maßgeschneidert für die Hörakustikbranche gibt.
Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann.
Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann.
Schon seit langer Zeit wird vermutet, dass die Dauer der Einsilber des Freiburger Sprachtest, vor allem im Störgeräusch nicht ausreicht, damit Hörsysteme mit längeren Regelzeiten diese effektiv erfassen können. Diese Arbeit hat als Ziel diesen Umstand anhand dreier Hörgeräte unterschiedlicher Hersteller zu untersuchen umso etwaige Rückschlüsse für die Praxis ziehen zu können.
EMDR-Therapie im Vergleich zu EMDR-Therapie, erweitert durch taktilen und auditorischen Stimulus
(2023)
EMDR (Eye Movement Desensitization and Reprocessing) ist ein neurobiologisch orientierter psychotherapeutischer Ansatz zu Behandlung von posttraumatischen Belastungsstörungen (PTBS) und anderen belastenden Lebensereignissen. Dabei werden Augenbewegungen eingesetzt, um die Verarbeitung und Integration traumatischer Erinnerungen zu erleichtern. Diese nichtinterventionelle Anwendungsbeobachtung untersucht die Bedeutung von Augenbewegungen in EMDR und potenzielle Vorteile der Einbeziehung auditiver und taktiler Reize in die Therapie.
In dieser Bachelorarbeit wurde die Android-Applikation Aalener Optik-Formelrechner entwickelt. Sie soll die Studenten des Studiengangs Augenoptik bei der Berechnung einer Vielzahl von optischen Funktionen unterstützen. Zudem kann sie als Plattform für interaktive Vorlesungen verwendet werden und damit Studieninhalte effizienter vermitteln sowie den Lernerfolg steigern. Die implementierten Funktionen können semesterübergreifend verwendet werden.
In der globalen Industrie und in der Medizin ist der 3D-Druck von Bauteilen oder als Grundlage für die Zellbesiedelung mittlerweile nicht mehr wegzudenken. Um Kosten und Zeit zu sparen, werden oft zunächst Prototypen im 3D-Druckverfahren hergestellt und auf Funktionalität getestet. Ziel der vorliegenden Arbeit „Entwicklung eines 3D-Ohrmodells“ war es zu überprüfen, ob es der aktuelle Stand der Forschung und Technik im vielseitigen Bereich des 3D-Druckes ermöglicht, ein 3D-Ohrmodell zu drucken, welches möglichst realitäts-nah und detailgetreu das menschliche Ohr wiederspiegelt und zu Ausbildungszwecken herangezogen werden kann. Dieses Ohrmodell soll verschiedene Anforderungen erfüllen. Einerseits soll es verschiedene Härtegrade aufweisen, vergleichbar mit dem menschlichen Ohr, insbesondere mit den Strukturen Ohrläppchen (Fettgewebe & Haut, weich), Knorpel (mittelhart) und Knochen (hart). Andererseits soll es anatomisch korrekt sein, da es auf dem Markt kaum Modelle gibt, die die anatomischen Gegebenheiten realitätsnah darstellen. Weiterhin soll es möglichst transparent sein, sodass es langfristig als Übungsohr in der Ausbildung von Hörgeräteakustiker/-meistern oder Studieren-den der Hörakustik in den Bereichen Ohrabformung und In-situ-Sondenschlauchplatzierung verwendet werden kann. Der Vorteil eines transpa-renten Modells ist die einfachere Beurteilung der Platzierung von wichtigen Komponenten, wie bspw. Sondenschlauch oder Abformmasse.
Als Ausgangslage für das 3D-Ohrmodell dienten Scan’s eines Ohrmuschelmo-dells und einer tiefen Ohrabformung, die per 3D-Scanner eingescannt, mit der Hilfe von CAD Experten bearbeitet, zusammengefügt und anschließend ausgedruckt wurden. Das Ergebnis dieses Entwicklungsprozesses ist ein Modell, welches die anatomischen Gegebenheiten sehr gut darstellt. Es wurde zunächst aus Kostengründen nur in unterschiedlichen Graustufen gedruckt, ein transparentes Modell ist aber zukünftig ebenso herstellbar. Das entwickelte Ohrmodell weist zwar unterschiedliche Härtegrade auf, Ohrläppchen und knorpeliger Teil des Ohres sind aber im direkten Vergleich zum menschlichen Ohr zu hart. In diesem Punkt besteht zukünftig noch viel Entwicklungspotential.
Das Ergebnis dieser Arbeit kommt der Ausgangsidee bereits ziemlich nah, es muss aber noch eine Weiterentwicklung der Materialqualität und –art stattfinden.
Die Bachelorarbeit widmet sich der Entwicklung eines automatisierten Telefonhörtests und dessen Nutzen in der Praxis der Akustikerin/ des Akustikers.
Eine kostenfreie, freiverfügbare Telefonleitung wird eingerichtet und der Nutzen sowie die Qualität des
Hörtests werden mithilfe einer Studie analysiert. Der Telefonhörtest entsteht in Kooperation mit der Hochschule Aalen für Technik und Wirtschaft und dem Frauenhofer-Institut Oldenburg
für digitale Medientechnologie. Für die Entwicklung des Telefonhörtests sind theoretische und praktische
Vorüberlegungen zu der Umsetzung notwendig. Im ersten Teil der Arbeit wird auf das Telefon und seine Funktionsweise sowie seine Bedeutung in der Gesellschaft eingegangen. Ein wichtiger Aspekt ist hierbei die Übertragungsbreite des Telefons. Interessant ist auch die Erkenntnis des unveränderten Trends der Freizeitbeschäftigung der Deutschen. Im weiteren Verlauf werden die Anforderungen und die Umsetzung des Telefonhörtest geklärt. Der Test muss jederzeit frei verfügbar und kostenlos zu nutzen sein. Darüber hinaus sollte er leicht zu bedienen sein und nur wenig Zeit in Anspruch nehmen. Die Aufnahmen müssen zwingend gut verständlich, wiederholbar und bei jedem Anruf in gleicher Lautstärke wiedergegeben werden. Das
Tonbearbeitungsprogramm Audacity 1.3 Beta wird zur Aufnahme und Bearbeitung der Klangbeispiele verwendet. Die Datengröße der Aufnahmen werden für den Telefonserver minimiert und anschließend mit Audacity 1.3 Beta bearbeitet. Für die Validierung des Telefonhörtests wird mithilfe von Fragebögen eine Studie mit fünf Hörakustikbetrieben durchgeführt. Die zentralen Ergebnisse der durchgeführten Studie sind, dass 97 % der Hörgerätekunden und 81 % der Hörakustiker und Hörakustikerinnen ein Nutzen des Telefonhörtest sehen. 93 % der Befragten Akustiker und Akustikerinnen würden den Telefonhörtest in Zukunft anwenden oder bei passenden Fällen zur Unterstützung bei einer Hörgeräteanpassung nutzen. Der entwickelte Telefonhörtest zeigt, dass es möglich ist die gestellten Anforderungen umzusetzen. Die Verständlichkeit der Klangbeispiele werden von 88 % der Studienteilnehmer mit gut bis sehr gut bewertet und ist somit erfüllt. Da es sich um einen automatisierten Telefonhörtest handelt, ist auch die Wiederholbarkeit in gleichbleibender Lautstärke gegeben.
Das Ziel dieser Arbeit ist die Erstellung eines Konzepts für eine Software zum Erler-nen der Refraktionsbestimmung, welches die Erweiterung um zusätzliche Refraktionsschritte und Refraktionsmethoden sowie eine Umsetzung der Programmierung ohne augenoptische Kenntnisse ermöglicht. Die Programmgestaltung soll in Oberfläche, Funktionsumfang und Probandeneigenschaften der realistischen Refraktionsbestimmung näher kommen als die bisher verfügbaren Refraktions-Simulationsprogramme „Refsim7“ und „Electric Optitian PE“.
Das Konzept umfasst die monokulare Refraktion für die Ferne mit den Methoden Kreuzzylindermethode und Zylindernebelmethode für die Bestimmung des Astigmatismus und Rot-Grün-Test und Sukzessiv-Abgleich als Methoden für den monokularen sphärischen Feinabgleich. Des Weiteren umfasst es die Umsetzung vier verschiedener Eigenschaften des Probanden, die sich auf die Kommunikation auswirken: normales Verhalten, kann sich nicht entscheiden, verwechselt rechts und links und hört schlecht. Ebenso werden in dem Konzept die Aspekte Augenerkrankungen und Hornhautscheitelabstand berücksichtigt. Dazu gibt es fünf verschiedene Auffälligkeiten des Probanden, die auf den Erkrankungszustand des Auges, auf das Erkrankungsrisiko oder auf die Berücksichtigung des HSA schließen lassen. Diese sind starke Refraktionsänderung über einen kurzen Zeitraum, ein optisch nicht korrigierbares Problem, ein geringer Visus, ein höheres Probandenalter und eine höhere Fehlsichtigkeit.
Die Vorgehensweise für die Arbeit ist wie folgt strukturiert. Zunächst wird eine Recherche über bestehende Programme zum Erlernen der Refraktion durchgeführt. Anschließend erfolgt die Erarbeitung von Grundlagen zur Refraktionsbestimmung und anderen Aspekten der Refraktion. Abschließend wird das Konzept aus der Recherche und den Grundlagen erarbeitet.
Ziele: Mithilfe des in dieser Arbeit entwickelten Konzeptes soll die Sehleistung noch einfacher ermittelt werden. Hierfür soll das plusoptiX Binokular Autorefraktometer so weit verändert werden, dass es zusätzlich zum Ermitteln der Sehleistung genutzt werden kann. Methodik: Es wurden 212 Probanden im Alter von drei bis fünfzehn Jahren untersucht. Die Sehleistung wurde zum einen anhand der LEA Symbole ermittelt und zum anderen mithilfe des in dieser Arbeit entwickelten Konzeptes. Ergebnisse: In wenigen Fällen kam es zu einer Abweichung von einer Visusstufe. Hierbei lässt sich keine Tendenz feststellen mit welchem Verfahren die Probanden größere Schwierigkeiten hatten. Die Standardabweichung liegt bei den Probanden ohne Korrektur bei 0,35. Die Probanden mit Korrektur haben eine Standardabweichung von 0,44. Der durchschnittliche Nahvisus liegt bei 0,8. Zusammenfassung: Es lässt sich sagen, dass die Ermittlung der Sehleistung anhand dieses Konzeptes sehr gut durchführbar ist. Der Ablauf und die Eingabemaske lassen sich im weiteren Verlauf noch verbessern. Des Weiteren kann dieses Konzept langfristig für weitere Bereiche wie Myopie Management und Visual Training weiterentwickelt werden.
Entwicklung eines Prototyps zur Aufnahme der Verzeichnung von Brillengläsern in Gebrauchsstellung
(2017)
Der Zweck bzw. das Ziel der vorliegenden Arbeit ist es, einen Prototypen eines Messaufbaus zu entwickeln und zu konstruieren, mit welchem die Verzeichnung durch Brillengläser in Gebrauchsstellung computergesteuert unter verschiedenen Blickwinkeln aufgezeichnet und dargestellt werden kann.
Material und Methoden
Als Modellauge wird eine digitale Kamera verwendet, welche an einen Single-Board-Computer (Raspberry Pi Model 3 b) angeschlossen wird. Zur Realisierung der Blickbewegun-
gen wird ein Schrittmotor verwendet, der ebenfalls mit dem Raspberry Pi verbunden ist. Die Geräte werden durch einen externen PC über MATLAB (Version 2016b) angesteuert. Hierfür werden unterschiedliche Funktionen zur Steuerung der Kamera und des Schrittmotors entwickelt. Zudem wird ein mechanischer Aufbau entworfen und konstruiert, welcher die Lage des Augendrehpunkts, der Eintrittspupille des Auges und des augenseitigen Brillenglasscheitels berücksichtigt. An ihm sind der Hornhautscheitelabstand und die Vorneigung des Glases einstellbar. Schließlich werden zwei Gleitsichtgläser (GS 1 und GS 2) mit planer sphärischer Fernrefraktion untersucht und ihre statische und dynamische Verzeichnung dargestellt.
Ergebnisse
Sowohl GS 1 als auch GS 2 zeigen eine für Gleitsichtgläser typische statische und dynamische Verzeichnung.
Fazit
Der Prototyp liefert Aufnahmen, welche auf den subjektiven visuellen Eindruck durch ein Brillenglas hinsichtlich seiner Verzeichnung schließen lassen. Er kann somit für achfolgende Arbeiten als Ausgangspunkt herangezogen werden, welche sich mit der Verzeichnung von (Gleitsicht-) Gläsern in Gebrauchsstellung befassen.
Das Ziel der vorliegenden Bachelorthesis besteht in der Entwicklung und Herstellung eines Videootoskops. Das Vorgehen orientiert sich dabei an den Vorschriften und Verfahren zur Entwicklung eines Medizinproduktes, wie sie im Gesetz über Medizinprodukte aufgeführt sind.
Die Richtlinie 93/42/EWG nennt dazu zum einen grundlegende Anforderungen welche ein jedes Medizinprodukt erfüllen muss.
Zum anderen gibt sie, je nach Klassifizierung des Medizinproduktes, ein entsprechendes EG-Konformitätsverfahren vor.
Auf Basis dieses Verfahrens erfolgt sowohl die
Konstruktion des Videootoskops, als auch die technische Dokumentation der Entwicklung.
Für die Herstellung der Gehäuseteile wird ein handelsüblicher Stereolithographie-Drucker verwendet, wie er auch für den 3D-Druck von Otoplastiken zum Einsatz kommt.
Die elektronischen Komponenten bestehen aus einfach zu beziehenden Einzelteilen, die über einen Raspberry Pi Zero W im Inneren des Videootoskops angesteuert werden.
Als Betriebssystem kommt „Raspbian“ zum Einsatz.
Die einzelnen Funktionen, welche für den Betrieb des Videootoskops nötig sind, werden über separate Programme gesteuert. Das so entwickelte und hergestellte Videootoskop erfüllt die grundlegenden Anforderungen zur Durchführung einer
Videootoskopie.
Es liefert dazu die Möglichkeit das Bildmaterial mittels eines beliebigen Webbrowsers über einen
Live-Stream aufzurufen und zu verfolgen.
Hinsichtlich der Umsetzung der gesetzlichen Vorschriften besteht jedoch weiterer Handlungsbedarf um ein vollständiges EG-Konformitätsverfahren zu durchlaufen. Nur so sind eine CE-Kennzeichnung und ein Vertrieb des Videootoskops möglich.
Entwicklung und Analyse einer Messmethode zur Bestimmung des individuellen Insets mittels Kamera
(2016)
In dieser Arbeit wird eine Messmethode zur Bestimmung der individuellen Pupillendistanz für den Nahbereich und des damit einhergehenden individuellen Insets entwickelt.
Bei der Methode handelt es sich um Kameramessungen in einer definierten Prüfdistanz von 400 mm. Die Fixation erfolgt auf eine Fixationsmarke, die zentrisch vor dem Kameraobjektiv angebracht ist. Je Messreihe werden zehn Einzelmessungen durchgeführt, deren Mittelwert für die weiteren Vergleiche herangezogen wird.
Die Methode wird durch verschiedene Messungen an insgesamt drei Probanden und einem Kunstkopf untersucht und deren Ergebnisse werden mittels Vergleichsmessungen traditioneller Messmethoden auf Plausibilität geprüft. Der Mittelwert über die Standardabweichungen der gemessenen Pupillendistanzen aller Messreihen beträgt 0,04 mm.
Im weiteren Verlauf werden verschiedene Korrekturfaktoren hergeleitet, die Messungenauigkeiten wie beispielsweise den perspektivischen Fehler ausgleichen. Die Abweichungen zwischen den aus diesen Messungen berechneten Insets und den geometrisch berechneten Insets liegen in einem Bereich von 0,05 mm bis 0,38 mm.
Die Ergebnisse aller Messungen zeigen zudem für die drei untersuchten Probanden einen kleineren binokularen Inset von 3,21 mm bis 4,18 mm auf als der für Standardgleitsichtgläser verwendete Inset von insgesamt 4,0 mm bis 5,0 mm.
Ziel der Thesis:
Das Ziel dieser Bachelorarbeit ist es, einen Fragebogen zu entwickeln, um die Kostenakzeptanz bei Eltern zu ermitteln, deren Kinder Myopiepräventionsmaßnahmen benötigen. Dieser Fragebogen kann einem auf Myopieprävention spezialis ierten Optometristen bei der Preisgestaltung der angebotenen Versorgung unterstützend helfen. Des Weiteren wird ausführlich ein strukturierter Ablaufplan beschrieben, anhand dessen der behandelnde Optometrist/Optiker die betroffenen Kinder und Jugendliche optimal betreuen kann.
Methode/Vorgehensweise:
Um das Ziel dieser Bachelorarbeit zu erreichen, wurde zu Beginn eine Literaturrecherche durchgeführt.
Es wurden Studien, Papers und Fachzeitschriften analysiert und Ursachen,Epidemiologie und Behandlungsmaßnahmen der Myopieprogression herausgearbeitet. Mithilfe dieser Informationen wurde ein Myopiepräventionskonzept und anschließend ein Fragebogen entwickelt.
Ergebnisse:
Eine beginnende oder fortgeschrittene Myopie lässt sich durch entsprechende Myopiemaßnahmen behandeln. Das Längenwachstum eines myopen Auges gilt es einzudämmen, da es sich unbehandelt bis ins Erwachsenenalter progressiv verhält und weitere irreversible Augenerkrankungen hervorrufen kann. Die weltweit ansteigende Myopieprävalenz ruft zu einem Handeln auf,
da etwa die Hälfte der Weltbevölkerung im Jahre 2050 kurzsichtig sein wird. Ursachen hierfür sind vielfältig. Vermehrte Naharbeit, genetische Faktoren, wenig Außenaktivität und binokulare Seheigenschaften spielen eine große Rolle. Versorgungen, die im Myopiemanagement eingesetzt werden, sind Mehrstärkengläser, myopische Brillengläser, Orthokeratologie-kontaktlinsen, multifokale Kontaktlinsen, myopische Kontaktlinsen und Atropin.
Das Ergebnis des Fragebogens zeigt, dass Eltern bereit sind, monatlich 38,89±16,15€ für eine Versorgung zur Myopiekontrolle bei ihrem Kind zu investieren. Dies deckt sich mit den in der Praxis angegeben Preisen von 35€ bis 52€ für Kontaktlinsen und 29€ für spezielle Myopiebrillengläser.
Leider werden die Kosten von der gesetzlichen Krankenkasse nicht übernommen. Hier besteht Handlungsbedarf, denn es kann im Erwachsenenalter zu hohen Kosten für Folgeerkrankungen einer hohen Myopie oder deren Korrektionsmaßnahmen kommen.
Schlussfolgerung:
Der Umfragebogen und dessen Ergebnis sollen dem Myopiespezialisten helfen, Versorgungsangebote
mit Brille oder Kontaktlinsen preislich den Vorstellungen und damit der Akzeptanz der
Eltern anzupassen. Somit kann eine maximale Effizienz und Zufriedenheit erreicht werden.
Die Augenoptikbranche befindet sich beim Umbruch in die digitale Zeit, und deren neue Methoden, noch am Anfang. Nur zwei Prozent der Brillen in Deutschland werden ausschließlich online gekauft. Daher wird in allen Bereichen der Augenoptik (z.B. Zentrierung, Fassungsauswahl, etc.) an digitalen Lösungen gearbeitet. Teilweise ist bereits jetzt schon eine Onlinekundenbetreuung durch das Einsetzten von digitalen Medien, z.B. Videoanleitungen, möglich. Videoanleitungen können von Kunden zu jedem Zeitpunkt an jedem Ort abgerufen werden. Durch diese Flexibilität genießt der Kunde eine Kundenbetreuung vergleichbar mit anderen Marktbranchen, die bereits vollständig im Onlinehandel angekommen sind. Hierbei ist es wichtig die Individualität einer Brille nicht aus den Augen zu verlieren und speziell auf diese einzugehen. In dieser Arbeit ist ein digitales Konzept ausgearbeitet, welches sich aus einem Aufbauschema der Videos, Skripten, Drehbüchern und den daraus entstehenden Videos zusammensetzt. Durch verschiedene Videoanleitungen bietet es Lösungen für Probleme beim Brillensitz mit dem Ziel, dass diese, unabhängig von Ort und Zeit, selbstständig durch den Kunden gelöst werden können.
Augenoptische Betriebe schaffen mit erfolgreichen Geschäftsmodellen den Sprung aus der Vergleichbarkeit. Erfolgsentscheidend auch im Hinblick auf die Differenzierung gegenüber dem Internet ist das Angebot optometrischer Dienstleistungen.
Ziel dieser Bachelorthesis ist die Erforschung und Entwicklung von erfolgreichen Geschäftsmodellen in der Augenoptikbranche. Die Basis von Geschäftsmodellen bilden die optometrischen Dienstleistungen. Durch das einheitliche Produkt- und Leistungsangebot ist es wichtig Kundenerlebnisse zu kreieren, um sich von Wettbewerbern abzuheben und eine langfristige Bindung an das Unternehmen zu gewährleisten.
Im Hinblick auf die Kontaktlinsenbranche werden Geschäftsmodellinnovationen erläutert, die verhindern sollen, dass Kunden ins Internet abwandern. Daraus ergab sich die Frage, ob diese noch zeitgemäß sind, oder ob ein Umbruch hinsichtlich dieser Frage stattfindet. Mithilfe eines Experteninterviews mit einem Inhaber eines stationären Familienunternehmens wird der zunehmende Wandel der Konsumenten sehr deutlich. Nur wer am Zeitgeist des Geschehens bleibt und sich auf veränderte Rahmenbedingungen, wie die zunehmende Konnektivität einlässt, wird mit dem „neuen“ Konsumentenverhalten auch in Zukunft mithalten können.
Das Ziel dieser Bachelorthesis ist die Ausarbeitung eines Dienstleistungs- und Serviceangebots im Bereich Kontaktlinse in Form eines Abo- bzw. Service-Systems in Zusammenarbeit mit der SEHENSWERT GmbH. Da es noch keine wissenschaftliche bzw. betriebswirtschaftliche Ausarbeitung zu diesem Thema als Leitfaden gibt, soll diese Arbeit den Einstieg in das Thema Kontaktlinsen-Service-Systeme erleichtern und als Anleitung für kleinere augenoptische Betriebe dienen.
Der praxisnahe Einsatz und die effiziente Umsetzung stehen dabei im Vordergrund der Überlegungen. Deshalb werden im Abschnitt der Umsetzung und Kalkulation typische Produkte vorgestellt.
Die Kalkulationssätze bilden dabei wiederum Orientierungshilfen für den Einsatz im Fachgeschäft.
Die Ausgangslage für das SEHENSWERT-Konzept bilden dabei zwei unterschiedliche Angebote im Bereich von Abo-Systemen für Kontaktlinsen. Es wird die Industrielösung „elina“ von der Alcon® Pharma GmbH und das „liky.my.eyes“-System der Marketinggemeinschaft von der Brillen-Profi-Contact GmbH verglichen.
Des Weiteren sollen dem Kontaktlinsenanpasser Argumentationshilfen und Beratungstechniken, die die Ansprache auf Kontaktlinsen erleichtern sollen, aufgezeigt werden.
Die Zielvorstellung ist nämlich nicht nur Kontaktlinsen im System zu verkaufen, sondern auch die proaktive, vermehrte Ansprache von Kunden auf das Thema Kontaktlinsen.
Zugleich soll ein regelmäßiger Kontroll-Rhythmus bei Augen- und Kontaktlinsenchecks etabliert werden, da die Gesundheit der Augen und das sichere Tragen von Kontaktlinsen für den Kunden gewährleistet sein müssen. Dazu zählt auch die Verbesserung der Kommunikation mit dem Endverbraucher nach der Versorgung mit Kontaktlinsen.
Im Rahmen dessen werden fortschrittliche und zeitgemäße Kommunikationstechniken erläutert und deren Einsatz aufgezeigt.
Ziel der vorliegenden Bachelorarbeit war es, ein Weblog für die studentische Kontaktlinsensprechstunde des Studiengangs Augenoptik an der Hochschule für Technik und Wirtschaft in Aalen zu erstellen. Im Rahmen der Sprechstunde werden Kunden durch die Studierenden mit Kontaktlinsen versorgt. Das Weblog soll sowohl den Kunden als auch den Studierenden als Informati-onsquelle sowie zur Vor- und Nachbereitung der Kontaktlinsensprechstunde dienen. Es wurde mithilfe der Software WordPress.org erstellt. Diese lag in der Version 3.5.1 auf einer externen Festplatte mit dem Betriebssystem Ubuntu Linux 12.04 LTS vor. Das erstellte Weblog setzt sich insgesamt aus 36 Seiten zusammen, wobei acht als Hauptseiten eingerichtet wurden. Insgesamt wurden 48 Bilder eingefügt um die verfassten Texte zu verdeutlichen. Außerdem wurde ein Glossar eingerichtet, dank dem sich die Leser Erklärungen zu verschiedenen Fachbegriffen anzeigen lassen können.
Materialien für individuelle Kontaktlinsen sind sehr vielfältig in Hinsicht auf ihre
Materialeigenschaften und Beschaffenheit. Einen Überblick über die
Eigenschaften bieten bereits diverse Sammelwerke in Buchform.
Das im Rahmen dieser Bachelorthesis „Erstellung eines Webportals zum
Vergleich von individuellen Kontaktlinsenmaterialien“ entstandene Webportal
www.lensmaterial.info
soll dem Benutzer eine übersichtliche Darstellung der verfügbaren Materialien
für individuelle Kontaktlinsen bieten. Darüber hinaus bietet das Webportal eine
Filterfunktion, um das optimale Kontaktlinsenmaterial bezüglich verschiedener
Voraussetzungen zu suchen. Die Datenbank umfasst neben den formstabilen
und weichen Materialien auch Listen von Material- und Kontaktlinsenherstellern.
Das Webportal soll nach Abgabe dieser Bachelorthesis weiter geführt und
ausgebaut werden.
Im Rahmen dieser Bachelorarbeit „Erstellung eines Webportals zur Einführung in die beruflichen Chancen und Möglichkeiten nach dem Augenoptik/Augenoptik- und Hörakustikstudium (B.Sc.)“ wird eine Webseite entwickelt, die die Studierenden und Bewerber im Studiengang Augenoptik/Augenoptik und Hörakustik an der Hochschule Aalen darüber informieren soll, welche beruflichen Perspektiven sich nach einem erfolgreichen Studium für sie ergeben könnten.
Um dies erreichen zu können, werden die zur Generierung der Webseite notwendigen Installationen vorgenommen. Hier wird zunächst auf die Entwicklungsumgebung und anschließend auf die Skriptsprache auf der die Webseite basiert eingegangen. Weiterhin wird das Datenbanksystem auf welches die Webseite zugreift um Inhalte bei Bedarf anzeigen zu können erläutert. Danach wird das zur Erzeugung der Webseite verwendete Programm WordPress und die Vorgehensweise bei der Absolventenbefragung vorgestellt.
Die Absolventen sollen hierbei nach der Kontaktaufnahme dem Verfasser Tätigkeitsbeschreibungen und ggf. Besonderheiten beim jeweiligen Bewerbungsverfahren zukommen lassen. Diese aus der Berufspraxis erhaltenen Berichte, werden anschließend zur Informationsbereitstellung anonymisiert in die Webseite integriert.
Nun wird in einem Vergleich festgestellt, dass andere Hochschulen in Deutsch-land in ihren Bachelorstudiengängen der Augenoptik/Optometrie und Hörakustik bisher kein zusätzlich entwickeltes Webseitenangebot mit Absolventenberichten bereitstellen.
Des Weiteren erfolgt eine Analyse eines Orientierungstests zur Studienorientierung und– Bewerbung. Hierbei wird erläutert, welche Vor- und Nachteile dieses Verfahren für Bewerber und Interessenten aufweist und welche Rolle das erarbeitete Konzept der vorliegenden Arbeit dabei spielt.
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.
The increasing prevalence of myopia throughout the industrialized world in recent decades has caused costs and problems for the eye health. Changed lifestyle and behavior are the main causes. For the pathogenesis of myopia, the amount of time spent outdoor and near activities play an important role. Various options for the treatment of myopia have been described as effective in the literature. Normal single vision glasses and contact lenses can only provide clear vision, but do not reduce myopia progression. Orthokeratology shows a slowing of axial growth, but has an increased risk of infectious keratitis. Low-dose atropine (0.01%) is currently the best pharmacological option. It proved safe, effective and showed the least rebound effect with negligible side effects. Other options for the treatment of myopia include special glasses, behavioral changes and prolonged outdoor exposure (to prevent the onset of myopia), as well as other methods. An increasingly important myopia management option is multifocal contact lenses, that provide a peripheral treatment zone producing myopic defocus. Such myopia control lenses are available as customized or as daily or monthly lenses. Children benefit from wearing contact lenses more than just having refractive error correction and myopia control, they have a better self-esteem and improved quality of life. The numerous findings on the safety and efficacy of soft multifocal distance center contact lenses in children to reduce the progression of myopia suggest that this modality should be considered as a main treatment option. Less, but similar to orthokeratology, when wearing soft lenses there is a risk of developing potentially serious complications such as microbial keratitis. The introduction of child-appropriate risk minimization strategies, and patient and parent education with regular monitoring is essential and leads to successful contact lens wear. This literature review summarized the actual knowledge about myopia management, prevalence, etiology and the visual and healthy consequences of myopia.
The three currently most important strategies for slowing the progression of myopia are soft multifocal distance center contact lenses, Orthokeratology and low-dose atropine ophthalmic drops.
Diese Bachelorthesis beschreibt Gründungs- und Unternehmensführungsstrategie anhand einer handlungsorientierten und konstruktivistischen Lernstrategie VaKE (Value and Knowledge Education) zum Erlangen der beruflichen Handlungsfähigkeit. Dabei teilt sich die Arbeit in drei Hauptteile wie folgt auf: Im ersten Teil wird beschrieben welche Kompetenzen und Eigenschaften zusammen die berufliche Handlungsfähigkeit ergeben, und wie diese erworben werden kann. Weiterhin wird der geschichtliche Hintergrund von Qualifikationen und Handlungskompetenzen dargestellt. Im zweiten Teil dieser Bachelorthesis wird die Theorie zu den Gründungs- und Unternehmensführungsstrategien im Rahmen der allgemeinen Meisterprüfungsordnung (AMVO) herausgearbeitet und beschrieben. Dabei werden nach der AMVO im zweiten Handlungsfeld die Gründungs- und Übernahmeaktivitäten sowie das dritte Handlungsfeld der Unternehmensführungsstrategien genauer beschrieben. Das zweite Handlungsfeld gliedert sich in die Bedeutung der persönli-chen Voraussetzungen für den Erfolg der beruflichen Selbstständigkeit, die wirtschaftliche, gesellschaftliche und kulturelle Bedeutung des Augenoptiker Handwerks, der Nutzen von Handwerksorganisationen sowie Entscheidungen zum richtigen Standort eines Augenoptischen Betriebes. Das dritte Handlungsfeld beschreibt die Bestimmungen des Arbeits-und Sozialversicherungsrechts, Instrumen-te zur Durchsetzung von Forderungen sowie theoretischen Grundlagen zur Insolvenz und deren mögliche Konsequenzen. Der dritte Teil dieser Bachelorthesis setzt sich aus handlungsorientierten Aufgaben zu den Gründungs- und Unternehmensführungsstrategien zusammen, welche im zweiten Teil genau beschrieben wurden. Diese Aufgaben werden anhand der konstruktivistischen Lernstrategie VaKE durchgeführt.
Im Rahmen dieser Bachelorthesis soll ein Leitfaden für das kompetenz- und handlungsorientierte Lehren und Prüfen erstellt werden. Am Beispiel der Arbeitsunterweisung des „Kommunikationstrainings“ soll verdeutlicht werden, wodurch sich eine Handlungs- und Kompetenzorientierung sowohl in Lehrveranstaltungen, als auch in Prüfungen auszeichnet.
Dazu wird zunächst die Theorie, die zur Entstehung der Handlungs- und Kompetenzorientierung in den Vorlesungen und Lehrveranstaltungen geführt haben, umrissen und in einen geschichtlichen Rahmen eingeordnet. Besonders beleuchtet wird dabei die internationale Leistungsmessung von Bildungsstandards; das sogenannte Bildungsmonitoring.
Der zweite Teil dieser Thesis gibt einen Überblick über die Definitionen von Kompetenzen und Handlungskompetenzen in schulischer, beruflicher und hochschulischer Bildung. Die Ansätze werden einander gegenübergestellt und Unterschiede und Gemeinsamkeiten herausgestellt.
Im dritten Teil der Arbeit wird die Theorie mit der Praxis verknüpft und die Handlungs- und Kompetenzorientierung anhand von Beispielen in konkrete Lehr- und Lernsituationen übertragen. Die hier entwickelten Prüfungsfragen und Lösungen werden auf ihren Kompetenzgehalt und ihre Handlungsorientierung hin untersucht und analysiert.
Nachdem das Forschungsgebiet der Selbsteinschätzung von Hörqualität bei Kindern und Jugendlichen im schulischen Alltag bislang kaum betrachtet wurde, setzt diese Studienarbeit
an dieser Stelle an.
Im Rahmen der Studie sollte bewiesen werden, dass es keine Unterschiede in der Hörqualität durch Selbsteinschätzung wie auch in der Hörqualität durch Fremdeinschätzung zwischen Cochleaimplantat- und Hörgeräteträgern gibt. Zudem sollte ermittelt werden, wie hoch die Hörqualität der einzelnen Versorgungsgruppen in Selbst- und Fremdeinschätzung ist.
Alle Daten wurden aus einer Gruppe von 21 Cochleaimplantatträgern (m = 9; w = 12) und einer Gruppe von 50 Hörgeräteträgern (m = 28; w = 22) erhoben. Die mittlere Altersgruppe der Cochleaimplantatträger lag bei „13 - 15 Jahren“, die der Hörgeräteträger „10 - 12 Jahren“. Im Durchschnitt waren alle Kinder seit mehr als 3 Jahren bilateral mit Hörsystemen versorgt.
Getestet wurde mittels neu entwickelten Fragebögen, bewertet anhand eines speziell dafür ausgelegten Punktesystems.
Die Hörqualität der Selbsteinschätzung konnte für beide Versorgungsgruppen mit „sehr gut“ bewertet werden. Die Ergebnisse der Hörqualität für die Fremdeinschätzung war für beide
Gruppen etwas schlechter und wurde als „gut“ eingestuft. Der größte Unterschied bestand in der Hörqualität der Selbst- und Fremdeinschätzung zusammen. Hier konnten die Cochleaimplantatträger eine „gute“, die Hörgeräteträger jedoch eine „sehr gute“ Hörqualität erreichen.
Kinder und Jugendliche mit Cochleaimplantaten schätzen ihre Hörfähigkeit in allen Bereichen der Hörqualität, sowohl in ihrer Selbst- als auch in ihrer Fremdeinschätzung schlechter ein, als
die Kinder und Jugendlichen mit Hörgeräten.
Einleitung: Die Bachelorarbeit „Hörtraining bei hörgeschädigten Kindern und
Erwachsenen – Stand der Wissenschaft“ soll einen Überblick über das Thema
Hörtraining, die verschiedenen Arten des Trainings und bisher erfolgte und
publizierte Studien geben. In diesem Review soll hauptsächlich auf das
Hörtraining bei schwerhörigen Kindern und Erwachsenen eingegangen werden.
Ziel: Das Ziel der Übersichtsarbeit war es, einen ersten, strukturierenden
Überblick über die vorhandene Literatur zum Thema Hörtraining zu erarbeiten
sowie Studien zu dem Thema aufzuzeigen. Ebenso sollen folgende Fragen
beantwortet werden: Was ist ein Hörtraining? Was macht man bei einem
Hörtraining? Welchen Nutzen hat ein Hörtraining und für wen ist es geeignet?
Was sind die Auswirkungen eines Hörtrainings auf das Gehör? Gibt es
Zusammenhänge der Ergebnisse einzelner Studien? Welche Empfehlungen
erschließen sich für die Praxis?
Methodik: Um einen Überblick zu dem Thema zu bekommen wurde eine so
genannte nichtforschende, narrative Literaturübersicht gemacht. Dadurch konnte
ein großes Wissen erarbeitet werden. Im Rahmen der Recherche zu Studien zu
dem Thema Hörtraining bei Kindern und Erwachsenen wurden zunächst 526
Quellen identifiziert, von denen abschließend 22 Studien und Reviews in diese
Literaturübersicht eingebunden wurden. Die Studien, die sich mit dem Hörtraining
bei Erwachsenen (n=9) und mit dem Training bei Kindern (n=13) befassen,
wurden bearbeitet, systematisch in Tabellen aufgelistet, zusammengefasst und
diskutiert.
Ergebnisse: Durch Auswertung der Studien und Reviews geht hervor, dass auf
Basis der bisherigen Studienlage keine eindeutige Bestätigung der Wirksamkeit
des Hörtrainings stattfindet. Grund dafür ist, dass der aktuelle Stand der
Wissenschaft zum Thema Hörtraining noch recht wenig aussagekräftige
Resultate aufzeigt. Weitere Studien sollten durchgeführt werden. Erfahrungen
aus der Praxis und Erfahrungsberichte der Probanden zeigen, wie wichtig ein
Hörtraining für Hörbeeinträchtigte sein kann.
Fazit: Der Review bietet einen ersten Überblick über den Stand der Wissenschaft
zum Thema Hörtraining. In Zukunft bedarf es der Durchführung
aussagekräftigerer Studien um die Effektivität des Hörtrainings zufriedenstellend
zu beweisen.
Ein immer größerer Teil der Bevölkerung in Deutschland absolviert die allgemeine Hochschulreife oder die Fachhochschulreife. Es ist demnach relevant, dass Hochschulen und Universitäten sich von Mitbewerbern abgrenzen und geschicktes Marketing betreiben, um potenzielle Studierenden zu erreichen und damit zu einem Studium an der Einrichtung bewegen.
Doch welche Maßnahmen sind diesbezüglich effektiv und wie stehen die Chancen, zukünftige Studierende zu einem Studium des Bachelorstudiengangs Augenoptik/Optometrie in Aalen zu motivieren?
Um diese Frage beantworten zu können, ist es relevant, den Studiengang und die Zielgruppe zu analysieren.
Wie bereits durch den Titel „Innovatives On- und Offlinemarketing am Beispiel des Augenoptik-/Optometrie-Bachelorstudiengangs der Hochschule Aalen“ angedeutet wird, sollen durch die Analyse des Studienganges sowie der Zielgruppe von Studierenden Strategien entwickelt werden, um die Anzahl der zukünftigen Studierenden des Studiengangs Augenoptik in Aalen zu erhöhen.
Der Aufgabenbereiche eines Augenoptikers ist vielfältig und er gilt als Spezialist, wenn es darum geht spezielle Sehanforderungen mit der richtigen Korrektionsmöglichkeit zu versorgen. „Die Aus-, Fort- und Weiterbildungsqualität in der Augenoptik gehört schon seit vielen Jahren zu der höchsten im Handwerk. Der Zentralverband der Augenoptiker (ZVA) hat es sich zur Aufgabe gemacht, das Kompetenzprofil der deutschen Augenoptiker auch für die Zukunft nachhaltig zu stärken.“ Egal in welcher Branche, Markt- und Wettbewerbsvorteile und somit auch die Sicherung des Arbeitsplatzes und des Lebensstandards, erlangt ein Jeder mit Wissen. Darum sollte es für jeden Menschen erstrebenswert sein, sein Wissen zu mehren.
Jeder Mitarbeiter muss gewillt sein seinen Wissensstand durch kontinuierliche Weiterbildung stetig auszubauen, denn der Kontakt zum Kunden will gelernt sein. Zu einem erfolgreichen Kundengespräch gehört mehr als nur eine richtige Aussprache, strukturiertes Vorgehen und Freundlichkeit. Übergeordnetes Ziel dieser Bachelorthesis ist es, neben der Erarbeitung der theoretischen Grundlagen interaktiver Videos in Lernarrangements, eine Lerneinheit zu erstellen, anhand derer sich Studenten der Augenoptik und speziell Studierende des dritten Semesters, die das Modul „Beraten und Verkaufen“ hören, orientieren können wie ein Verkaufsgespräch geführt wird. Die interaktiven Videos dienen der spielerischen Aneignung von Softskills und der Generierung überfachlicher Kompetenzen.
Internationale Optometrie
(2019)
Der vorliegende Leitfaden soll den Studierenden des Studiengangs Augenoptik/Optometrie der Hochschule Aalen eine bessere Vorbereitung auf das Auslandssemester ermöglichen. Für einen besseren Überblick werden die verschiedenen Abläufe sowie die Chancen und Herausforderungen dargestellt.
Der Leitfaden soll als Orientierungshilfe dienen und die Entscheidung für oder gegen ein Auslandssemester einfacher machen. Gleichzeitig soll den Studierenden die Relevanz der internationalen Optometrie verdeutlicht und allgemeine Informationen zur Optometrie weltweit bereitgestellt werden.
Im Rahmen dieser Bachelorarbeit „Konzept zur praktischen Entwicklung einer videobasierenden e-Learning-Plattform zur Unterstützung hörakustischer Praktikumsveranstaltungen am Beispiel der Tonaudiometrie“ wird ein Leitfaden entwickelt, anhand dessen es künftig ermöglicht wird, Lernvideos zur Unterstützung der Lehrveranstaltung „Audiologie Praktikum“ zu erstellen. Die Lernvideos sollen als Ergänzung der Lernveranstaltung dienen und den Studierenden wie den Praktikumsbetreuern als praktische Veranschaulichung verschiedener Themengebiete wie „Messung der Luftleitung“ dienen.
Im ersten Schritt werden die möglichen Themengebiete analysiert, bei denen sich eine praktische Veranschaulichung im Rahmen eines e-Learning-Moduls anbietet, welche Themengebiete für die Studenten ausschlaggebend sind und ob diese mit der in der Modulbeschreibung definierten Kompetenzen deckungsgleich sind. Es wird im Vorfeld überlegt, wie der Begriff des „e-Learning“ definiert ist und welche Vor- und Nachteile dieser mit sich bringt. Darüber hinaus wird der aktuelle „Stand der Entwicklung“ kurz erörtert, um aktuelle Themen wie beispielsweise Webinare einzuordnen. Vorrangig wird jedoch die Frage diskutiert, wie die Themen ansprechend und lernfördernd in einem entsprechenden Videoformat dargestellt werden können.
In diesem Rahmen wird auf die einzelnen Schritte eingegangen, die zur Entwicklung eines Lernvideos notwendig sind.
Es hat sich dabei gezeigt, dass die Erstellung des Drehbuchs die Grundlage jedes professionellen Lernvideos darstellt. Auch benötigte Softwareprogramme und Ausstattung, wie beispielsweise die Kamera, sind ausschlaggebend für die erfolgreiche Produktion eines e-Learning-Videos. Die Auswahl der Akteure und der Hintergrundsprecher/in, die eigentliche Videoaufnahme sowie deren fachgerechte Ver- bzw. Bearbeitung stellt einen weiteren wichtigen Teil in der praktischen Entwicklung von e-Learning-Videos dar.
Durch die im Anhang beigefügten Checklisten wird eine Unterstützung in der Umsetzung des vorliegenden „Konzept zur praktischen Entwicklung einer videobasierenden e-Learning-Plattform zur Unterstützung hörakustischer Praktikumsveranstaltungen am Beispiel der Tonaudiometrie“ gegeben. Die Umsetzung des Leitfadens wird in Form von vier produzierten Lernvideos veranschaulicht.
Das Ziel dieser Studie war es, die Einstellung der Akustiker aus einem Unternehmen hinsichtlich familienorientierter Hörsystemversorgung (fHV) zu überprüfen.
Zusätzlich sollte herausgefunden werden, ob die Einstellung durch eine kurze Videoschulung positiv zu beeinflussen ist. Ein weiteres Ziel war die Erstellung eines unterstützenden Konzepts zur Implementierung der fHV im Hörakustik Fachgeschäft.
Für eine optimale optometrische Untersuchung und ein kundenorientiertes
Beratungsgespräch bedarf es einer Vielzahl von Informationen über den
Kunden, die als allererstes im Rahmen einer Anamnese und Bedarfs- und
Wunschermittlung erfasst werden sollten. Eine vollständige Erhebung der
Kundeninformationen liefert die notwendige Grundlage für eine perfekte
augenoptische Versorgung.
Ziel dieser Abschlussarbeit ist es, ein Konzept für eine Applikation für den
Zeitraum zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung
zu entwerfen. Damit sollen die ersten beiden Phasen eines augenoptischen
Verkaufsgespräches strukturiert werden und eine effiziente Lösung auch in
Wartesituationen liefern. Mit der Einführung eines Befragungstools auf einem
Tablet-PC soll der Kunde zum einen auf die optometrische Untersuchung und
auf das bevorstehende Beratungsgespräch vorbereitet werden und zum anderen
soll die Beratungsqualität gesteigert werden.
Dazu wurden zunächst Interviews mit Geschäftsführern bzw. Filialleitern
augenoptischer Fachgeschäfte geführt, die vor allem Aufschluss über die Zeit
zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung geben
sollten.
Die Ergebnisse bestätigen, dass bei den meisten Augenoptikern die Zeit
zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung
unzureichend genutzt wird. Des Weiteren hat sich gezeigt, dass sich dieser
Zeitraum bei allen befragten Augenoptikern aus Teilen einer Anamnese,
Bedarfsermittlung und Bedürfnisweckung zusammensetzt. Bei den meisten
Befragten allerdings existiert weder ein strukturierter Ablauf über den Inhalt
noch findet eine Dokumentation im Sinne der Arbeitsrichtlinien für Augenoptik
und Optometrie statt.
Die Ergebnisse der Interviews decken sich mit größeren Studien und bekräftigen
somit einen dringenden Handlungsbedarf im Bereich der Anamnese und
Bedarfsermittlung, was schließlich mit der Konzeption eines digitalen
Befragungstools verbessert werden könnte.
Die optimale und exakte Brillenglaszentrierung ist seit je her der Mittelpunkt eines jeden Verkaufsgespräches. Die Anforderungen an eine exakte Brillenglaszentrierung steigen stetig, insbesondere nach der Etablierung individueller Gleitsichtgläser. Nur eine optimale Zentrierung ermöglicht dem Kunden ein angenehmes Tragegefühl. Deshalb ist die exakte Brillenglaszentrierung ein Muss. Die Möglichkeiten der Zentrierung reichen mittlerweile von manuellen Methoden über stationäre Videozentriergeräte bis hin zu Applikationen in Kombination mit Tablets. Letztere stellen die jüngste Innovation im Zeitalter fortschreitender Digitalisierung dar.
Ziel dieser Bachelorthesis ist es, die Erwartungen und die Zufriedenheit deutscher Augenoptiker in Bezug auf tablet-basierte Applikationen zur Brillenglaszentrierung zu ermitteln. Deshalb wird eine Befragung bei 500 unabhängigen Augenoptikern der Bundesrepublik Deutschland durchgeführt. Anhand der gewonnen Ergebnisse wird erfasst, welche Erwartungen sie haben und abgefragt, ob diese erfüllt werden oder nicht. Zudem wird untersucht, ob die Applikationen den Genauigkeitsanforderungen genügen und ob bestehenden Methoden, vor allem aber Videozentriersystemen, durch Apps zukünftig Gefahr droht.
Die Befragung zeigt, dass die Augenoptiker vergleichsweise wenig zufrieden sind, da ihre Anforderungen an eine Applikation zur Brillenglaszentrierung bisher nur unzureichend erfüllt werden. Dennoch ist diese neuartige Methode der Brillenglaszentrierung nicht zu unterschätzen. Es zeigt sich, dass der Trend zukünftiger Zentriermethoden immer mehr in Richtung tablet-basierte Applikationen geht, jedoch nur unter der Voraussetzung, dass diese zukünftig die Anforderungen der Anwender erfüllen. Die Apps befinden sich noch im Anfangsstadium, können sich aber durch weitere Entwicklungen früher oder später als feste Zentriermethode etablieren.
Wie das bekannte Sprichwort sagt: „Übung macht den Meister“, geht es in der augenoptischen Werkstatt häufig um das Üben von Fähigkeiten und Fertigkeiten.
Die größten Herausforderungen an einer Schule sind dabei die umfangreichen Versuchsbeschreibungen, die meist in der Darstellung nicht ausreichen und noch
zusätzliche Vorführungen der Lehrenden erfordern. Dazu kommt, dass bei größeren Gruppen in der Werkstatt unterschiedliche Versuche parallel laufen müssen und somit mehrere Lehrende gleichzeitig Vorführungen durchführen. Dies ist auf dem begrenzten Raum einer Werkstatt nicht möglich.
Als grundlegende Frage stellt sich hierbei, wie kann genügend Übung bei einem begrenzten Personalaufwand und begrenzter Werkstattgröße gewährleistet werden? Eine hervorragende Lösung dafür sind Lehrvideos.
Lehrvideos können von den Studierenden zu jedem Zeitpunkt abgerufen werden und ermöglichen außerdem das selbstständige Üben. Zudem ermöglichen die Lehrvideos einen optimalen Ausgleich zwischen der klassischen Vorlesung und dem selbstorganisierten Lernen und können auch bei etwas größeren Gruppen eingesetzt werden.
Dieses wird Blended Learning genannt und passt sich dem
digitalen Wandel dieser Zeit an.
Ziel dieser Bachelorthesis ist es, ausführliche Arbeitsabläufe für die augenoptische Werkstatt in Form von Lehrvideos zu erstellen. Diese sollen den
Studierenden den Einstieg in das Werkstattpraktikum erleichtern und individuelle Lücken füllen. Des Weiteren bieten sie die Möglichkeit, Lerninhalte selbstständig zu erarbeiten, zu wiederholen und zu üben.
Das Ziel der vorliegenden Thesis ist die Erarbeitung eines Leitfadens zur Anpassung von weichen individuellen Kontaktlinsen. Dabei werden auch die theoretischen Grundlagen betrachtet. In diesem Abschnitt wird besonders auf die Studien zur Anpassung über die Scheiteltiefe eingegangen. Um zu zeigen, welche Vorteile individuelle Kontaktlinsen haben, werden diese für den Kunden und den Augenoptiker in Bezug auf die Geometrie der Kontaktlinsen erläutert. Insgesamt soll die Thesis zur Orientierung für Studenten, Augenoptiker und Kontaktlinsenspezialisten bei der Anpassung von weichen individuellen Kontaktlinsen dienen.
Ziel:
Das Ziel dieser Arbeit ist es einen allgemeingültigen Leitfaden für die Erstversorgung der Presbyopie mit Kontaktlinsen zu entwickeln. Der Leitfaden soll Anpassern und Berufseinsteigern als unterstützendes Hilfsmittel dienen. Der Fokus liegt darauf, alle nötigen Faktoren in eine übersichtliche Form zu bringen, sodass bei der Anpassung eine systematische Reihenfolge entsteht und nichts übergangen wird. Dabei beziehen sich alle notwendigen Aspekte auf das reguläre Auge.
Material und Methoden:
Zur Entwicklung des Leitfadens dienen sowohl eine orientierende Fragebogen-Untersuchung von erfahrenen Anpassern zur ihrer Anpass-Philosophie als auch eine retrospektive Analyse der Anpass-Einzelschritte von 40 durch die Müller-Welt Contactlinsen GmbH versorgten Kunden. Zur Erläuterung der praktischen Anwendung des erarbeiteten Leitfadens werden am Ende dieser Arbeit 6 typische Versorgungssituationen bei Presbyopie detailliert dargestellt.
Ergebnisse:
Bei der Kontaktlinsenanpassung presbyoper Kunden ist eine ausführliche Anamnese die Basis für eine erfolgreiche Versorgung. Dies erreicht der Anpasser durch eine gute Kommunikation. Damit hierbei nichts versehentlich übergangen wird, bedarf es einer systematischen Vorgehensweise. Der im Rahmen dieser Arbeit entwickelte Leitfaden dient dafür als wichtiges Hilfsmittel. Er gliedert sich in vier große Teilbereiche:
1. Kontaktlinsenerfahrungen: Wenn der Kunde bereits Kontaktlinsenträger ist wird das Material übernommen, nach dem Motto „Never change a winning team“. Bei auftretenden Problemen werden diese zunächst beseitigt, bevor eine Presbyopieversorgung durchgeführt wird. Erst dann wird das Pres-byopiesystem ausgewählt. Trägt der Kunde bisher keine Kontaktlinsen, wird bei der Anpassung zunächst eine mehrwöchige Standardversorgung ohne Korrektion der Presbyopie durchgeführt (Gewöhnung des Kunden an Kontaktlinsentragen, Rückgang der anfänglichen Reizsekretion usw.). Nach einer erfolgreichen Eingewöhnungszeit wird dann erst im zweiten Schritt das Presbyopiesystem angepasst, das bereits im Voraus anhand der nachfolgenden drei Kriterien ermittelt wird.
2. Kundenwunsch: Er gibt Aufschluss über Anwendungsbereiche und Tragerhythmus sowie situative Umgebungsbedingungen und Sehanforderungen. Dadurch ergibt sich sowohl das Presbyopiesystem als auch das Kontaktlinsenmaterial.
3. Anatomischen Voraussetzungen: Sie liefern ebenfalls Ergebnisse bezüglich des Systems und Materials. Unter anderem beeinflusst die Lidposition die Systemwahl und trägt somit überwiegend zu dem Erfolg der Versorgung bei.
4. Art der Fehlsichtigkeit: Hier entscheidet hauptsächlich die Ausprägung der Addition über die Presbyopieversorgung.
Zu jedem der zuvor genannten vier Aspekte wird in dieser Arbeit jeweils ein gesondertes Flussdiagramm erarbeitet, womit der Anpasser gemeinsam mit dem Kunden das optimale Presbyopie-System individuell auswählen kann. Basierend auf diesen Flussdiagrammen wird für den praktischen Einsatz und eine erleichterte Dokumentation ein spezieller Formular- und Dokumentationsbogen erstellt. Abschließend wird in dieser Arbeit die praktische Anwendung des Leitfadens anhand von sechs typischen Fallbeispielen detailliert erläutert.
Schlussfolgerung:
Der Anpassleitfaden ist für die Presbyopieversorgung ein sinnvolles Hilfsmittel bei der Anamnese und Untersuchung sowie der zielgerichteten Auswahl des jeweiligen Presbyopiesystems.
Eine Weiterentwicklung des Leitfadens könnte in digitaler Form (z.B. App) erfolgen, so wird die Vorgehensweise noch benutzerfreundlicher. Es zeigt dem Kunden die innovativen und professionellen Methoden seines Augenoptikers auf. Das fördert die Kundenbindung und trägt somit zum wirtschaftlichen Erfolg durch die Presbyopie-versorgung mit Kontaktlinsen bei.
Novel myopia control spectacle lenses induce peripheral contrast reduction via optical diffusion. It is suggested, that the contrast reduction alters retinal processes in the low-level neural circuity, leading to an inhibition of eye growth. The purpose of this thesis is to evaluate the influence of full-field contrast reduction on low-level neural processing of the retina, described by the edge contrast sensitivity.
Das Thema Internationalisierung eines Studienganges spielt heutzutage eine sehr wichtige Rolle an der Hochschule in Aalen. Aus dem Grund wurde die vorliegende Bachelorarbeit im Auftrag des Studienganges Optical Engineering erfasst. Diese basiert auf einer Studentenumfrage bzw. Interviews in den Studiengängen Augenoptik/Augenoptik & Hörakustik und Optical Engineering, die mit einander verglichen werden, um die Ursachen einer geringen Teilnahme am studienbezogenen Auslandsaufenthalt im Studiengang Optical Engineering zu finden. Zusätzlich wurden Verbesserungsvorschläge bei der Planung und Organisation eines Aufenthaltes zur Steigung der Mobilität im Studiengang gebracht.
Bereits zu Beginn der Arbeit wurde eine Studentenumfrage durchgeführt, die eine überwiegende Zufriedenheit der dargebotenen Informationsquellen ergeben hat. Genauso wurden die Barrieren der Auslandsmobilität ermittelt und betrachtet. Bei den Interviews haben die auslandsmobile Studierenden ihre Erfahrungen geschildert und konnten einen studienbezogenen Auslandsaufenthalt zu 100% empfehlen. Es wurde eine Analyse des bestehenden Prozesses im Studiengang durchgeführt, wobei ein Schwerpunkt auf die Kommunikation, Zielfirmen/Institute, Finanzierung und Organisation eines Auslandsaufenthaltes gelegt.
Die Bestandteile dieser Arbeit sollen den Studierenden als eine Hilfestellung bei der Vorbereitung eines studienbezogenen Auslandsaufenthaltes dienen. Es wurden die Kontaktdaten der Ansprechpartner sowie zahlreiche Empfehlungen anhand von Literatur und Erfahrungsberichten zusammengestellt.
In dieser Bachelorarbeit geht es darum, ein System zu bauen, mit dem die Augenbewegungen gemessen werden können bei Verwendung von GS und im Vergleich dazu bei Verwendung von Einstärkengläsern (ES). Das System soll eine natürliche Lesesituation simulieren. Es sollen die Grenzen herausgefunden werden, wo der astigmatische Fehler beim Tragen von GS gerade noch akzeptiert wird. Hierfür soll keine Augentrackingbrille verwendet werden, sondern aufgrund der Kopfbewegungen (KB) und dem Wissen wo der Proband hinschaut, die Augenbewegungen (AB) berechnet werden.
Die Bachelorthesis befasst sich mit der Messung des individuellen Insets im
Nahbereich bei 30 Probanden. Mögliche Ursachen einer Gleitsichtglasunverträglichkeit
sollen erkannt und dargestellt werden.
Die Messungen zur Konvergenzprüfung der Augen werden mit einem an der
Hochschule entworfenen Gerät durchgeführt. Die Probanden fixieren neun
verschiedene Messpunkte in einer Leseentfernung von 40 cm, während die
Probanden selbst mittels Kamerafunktion Bildaufnahmen ihrer Blickrichtung
aufnehmen. Zur besseren Reproduzierbarkeit wird der Messdurchgang vier Mal
wiederholt. Mit Hilfe der Bildaufnahmen wird das Konvergenzverhalten in der
Nähe genau studiert.
Für diese Studie wurden Probanden unterschiedlicher Altersstufen vermessen
und in zwei Gruppen eingeteilt (<45 Jahre und >45 Jahre).
Für den Insetwert existiert in der Industrie ein theoretischer Standardwert von
2,5 mm. Dieser Standardwert wird mit den individuell gemessenen Insetwerten
aller Probanden verglichen.
Diese Studie zeigt auf, dass einige Probanden deutliche Abweichungen zum
Standardwert aufweisen.
Eine weitere Erkenntnis ist die unterschiedlich starke Konvergenz der beiden
Augen untereinander. Der gemessene Insetwert des rechten Auges weicht oft
stark vom Insetwert des linken Auges ab.
Eine Folgerung für diese asymmetrische Konvergenz ist eine inkomplette
Ausnutzung der Nahbereiche in Gleitsichtgläsern. Des Weiteren kann dieses
auch eine Unverträglichkeit zu Gleitsichtgläsern hervorrufen.
Zusammenfassend zeigt sich, wie wichtig es ist die individuellen Parameter der
Nahzentrierung in die Glasherstellung miteinfließen zu lassen. Die individuelle
Messung des Insets ist äußerst wichtig und sollte generell durchgeführt werden.
In Zeiten des disruptiven Wandels in der Augenoptik-Branche droht eigenständigen Optikern/Optometristen Gefahr, essenzielle Kundenanteile an Online-Händler zu verlieren. Daher werden zukünftig höhere Anforderungen des Marktes an Optiker/Optometristen gestellt, welche als erste Anlaufstelle der Bevölkerung gelten und umfangreiche optometrische Dienstleistungen rund um das visuelle System anbieten sollten. Folglich treten qualitativ hochwertige Weiterbildungen vermehrt in den Vordergrund, um eine exzellente Versorgung des Kunden zu gewährleisten und Wettbewerbsvorteile zu erzielen. Aufgrund der unterschiedlichen Weiterbildungs-möglichkeiten in Deutschland, gestaltet es sich für einen Studiengang als Hürde, sich von der Konkurrenz abzuheben. Daher erweist sich ein ausführlich herausgearbeitetes Marketingkonzept als Schlüssel zum Erfolg. Die vorliegende Bachelorthesis beschäftigt sich, auf Basis von Erkenntnissen quantitativer Studierendenbefragungen, mit der Gestaltung eines Marketing-konzepts für den berufsbegleitenden Masterstudiengang M. Sc. Vision Science and Business (Optometry) der Hochschule Aalen. Im Rahmen der Bachelorthesis werden theoretische Grundlagen zu wichtigen Begriffen aus dem Marketing erläutert, sowie gezielt mit Marketingstrategien und Umsetzungsvorschlägen für den berufsbegleitenden Master kombiniert.
Myopie-Management
(2021)
Das Ziel dieser Bachelorarbeit ist es, einen Workflow für den Bereich Myopie-Management, anhand internationalen Guidelines zu erstellen. Für die verschiedenen Myopie-Management-Maßnahmen werden hierfür effiziente Musterprozesse herausgearbeitet. Diese sollen als Leitfaden dienen und für Augenoptiker*innen und Optometrist*innen, welche sich im Bereich Myopie-Management spezialisieren, ein erfolgreiches und zukunf tsfähiges Geschäftsmodell mit effizienten Arbeitsschritten generieren. Zudem sollen die Mindestanforderungen in Aus- und Weiterbildung, Ausstattung und Räumlichkeiten aufgezeigt werden, um ein detaillierten Überblick zu geben.
Das Ziel der vorliegenden Bachelorarbeit ist es, ein Vorkonzept für die Brillenversorgung in Namibia von Kindern im Alter von 8 bis 12 Jahren zu erstellen. Die einzelnen möglichen Abläufe liegen verschiedenen Hilfsorganisationen zu Grund. Basierend auf den Durchführungen der Einsätze von Vereinen wie Brillen Weltweit, EinDollarBrille und Entwicklungsdienst Deutscher Augenoptiker sind verschiedene Konzepte entstanden, die unterschiedliche Schwerpunkte aufweisen.
Ziel dieser Arbeit ist es augenoptischen Betrieben für die Umsetzung einer gesellschaftlich verantwortungsvollen Unternehmensführung einen Leitfaden zu bieten. Hierbei wird auf die einzelnen Aspekte der Nachhaltigkeit und des sozialen Engagements eingegangen. Die Umsetzung soll durch konkrete Anleitung erleichtert werden.
Mit Hilfe einer Betriebsanalyse und Kundenbefragungen werden diverse Möglichkeiten gesellschaftlich verantwortungsvoller Unternehmensführung erörtert und eingegrenzt.
Des Weiteren dient diese Arbeit neben der Begriffserläuterung auch der Analyse in wie weit Kunden bereit sind ein gesellschaftlich verantwortungsvolles Unternehmen finanziell zu unterstützen.
In der vorliegenden Arbeit konnte gezeigt werden, dass durch eine Aufklärung über die Aspekte einer gesellschaftlich verantwortungsvollen Unternehmensführung Interesse bei Kunden geweckt wird und diese von ihnen auch durch finanzielle Unterstützung gefördert wird. Des Weiteren konnte gezeigt werden, dass auch kleine Veränderungen im Betrieb diesen nachhaltiger gestalten.
Ziele: Ein Handbuch zum umweltbewussten und nachhaltigen Wirken im Augenoptikfachgeschäft. Es zeigt, wie idealerweise gewirtschaftet wird unter Berücksichtigung ökonomischer, ökologischer und sozialer Aspekte.
Methodik: Diese Studie ist ein Wissenstank aus vielen verschiedenen Aspekten zu Umweltschutz und Nachhaltigkeit, die durch Literaturrecherche aufgebaut wurde. Die Informationen sind für den Nutzen im augenoptischen Betrieb ausgelegt.
Ergebnisse: Die Studie zeigt auf, wie viele Möglichkeiten es gibt und notwendig sind, um umweltverträglich zu wirtschaften und bringt ein Handbuch hervor für den Augenoptik-Betrieb. Verantwortungsbewusstes, nachhaltiges Handeln entsteht durch Kennen und Verstehen der Zusammenhänge mit anschliessender Umsetzung.
Es kann gezeigt werden, dass nachhaltiges Denken und Arbeiten in jedem Bereich angewendet werden kann und dabei sowohl die Umwelt als auch das Unternehmen unterstützt.
Zusammenfassung: Das entstehende Handbuch ist ein Leitwerk für Augenoptik-Betriebe. Durch die Umsetzung nachhaltigen Wirtschaftens mit einer möglichst optimierten Kreislaufwirtschaft ist nicht nur der Umwelt und den Menschen gedient, sondern auch der Fortbestand des Unternehmens, die Wettbewerbsfähigkeit und das positive Betriebsergebnis werden gefördert und gesichert.
Um Kunden langfristig einen optimalen Seh- und Tragekomfort gewährleisten zu können, ist die exakte anatomische Anpassung der Brillenfassung ebenso wichtig
wie die genaue Brillenglaszentrierung und die detaillierte Refraktionsbestimmung. Voraussetzung für eine gute anatomische Anpassung ist, dass der Augenoptiker die Eigenschaften des jeweiligen Brillenfassungsmaterials kennt und weiß, wie er das Material optimal handhaben sollte. Da besonders bei Kunststofffassungen für den Augenoptiker nicht immer klar ersichtlich ist, welches Grundmaterial verwendet
wurde und welche Materialeigenschaften und Handhabungsempfehlungen damit verbunden sind, beschäftigt sich diese Bachelorthesis mit den klassischen und neuartigen nichtmetallischen organischen und anorganischen
Brillenfassungsmaterialien, die momentan auf dem Markt verwendet werden.
Das Ausmaß der Beeinträchtigung durch eine Schwerhörigkeit ist eng mit dem Verlust des Sprachverstehens verbunden.
Das oberste Ziel einer Hörsystemversorgung ist deshalb das Wiederherstellen der Kommunikationsfähigkeit.
Beim Nachweis des Versorgungsnutzens stellt die Sprachaudiometrie einen wesentlichen Bestandteil dar.
In dieser Bachelorarbeit geht es um den Vergleich von Oldenburger Satztest und Oldenburger Kindersatztest in der Sprachaudiometrie Erwachsener.
Im Fokus der Untersuchungen standen dabei die Dauer der Messdurchführungen, der damit verbundene Konzentrationsaufwand für den Kunden und die Höranstrengung. Ziel der Bachelorarbeit war es aufzuzeigen, dass der Oldenburger Kindersatztest eine geeignete sprachaudiometrische Methode zur Ermittlung der Sprachverständlichkeitsschwelle bei Erwachsenen darstellt, da er aufgrund seiner reduzierten Durchführungsdauer den Kunden weniger belastet und anstrengt.
Ziel der Arbeit ist es Teilaspekte der Marktsegmentierung durchzuführen, um herauszufinden, ob bei Kunden verschiedener Vertriebswege Unterschiede vorliegen.
Insbesondere soll herausgefunden werden worauf Kunden beim Brillenkauf Wert legen, wie sie auf ihren Augenoptiker aufmerksam wurden, der Zufriedenheitsgrad der aktuellen Brille und inwieweit ihre Erwartungen erfüllt wurden.
Die Befragung erfolgte sowohl persönlich, als auch über das Internet, in Form einer Online-Umfrage. Dabei nahmen 135 Befragte an der Umfrage teil, wobei 40 % bei einem selbstständigen Optiker, 53 % bei einer Optikerkette, 3 % bei einem Online-Brillenshop und 5 % über weitere Vertriebswege ihren letzten Brillenkauf getätigt haben.
Hinsichtlich des Geschlechtes und der Krankenversicherungsart wiesen die Befragten, nach Optikerart gruppiert, keine nennenswerten Unterschiede auf. Jedoch tätigten mehr Befragte der Altersgruppe „18 bis unter 30 Jahre“ bei einer Optikerkette, als bei einem selbstständigen Optiker ihren Brillenkauf.
Es kann auch festgestellt werden, dass der relative Anteil sehr zufriedener Befragter bei Kunden selbstständiger Optiker höher als bei Optikerketten ist.
Zudem werden die meisten Kunden selbstständiger Optiker durch eine „Empfehlung von Verwandten/Bekannten“ auf den jeweiligen Optiker aufmerksam, wohingegen „gute Preisangebote“ bei Kunden von Optikerketten eine wichtige Rolle spielen. Für beide Kundengruppen sind die Kriterien „kompetentes Personal + Beratung“ und „zufriedenstellende Brillenqualität“ beim Brillenkauf am wichtigsten, wobei diese von Kunden selbstständiger Optiker wichtiger eingestuft werden.
Ein Einfluss des Berufsstands bei der Gewichtung der Kriterien nach Wichtigkeit konnte festgestellt werden, so dass beispielsweise „Angestellte“ im Vergleich zu
„Schüler/Studenten“ höhere Ansprüche bezüglich ihres Brillenkaufes haben.
Der allgemeine Erfüllungsgrad der Kriterien ist hoch, wobei allerdings die Kriterien bei selbstständigen Optikern noch besser erfüllt werden.
Des Weiteren konnten für einige Kriterien beim Erfüllungsgrad signifikante Unterschiede zwischen Optikerketten und selbstständigen Optikern festgestellt werden, bezüglich des Wichtigkeitsgrads jedoch nicht.
Die Weiterentwicklung der Augenoptikgeschäfte im Bereich optometrische
Dienstleistungen ist ein aktuelles Thema, dass von großer Bedeutung ist. Doch
wie sehr ist die Weiterentwicklung in den Augenoptikergeschäften angekommen?
Welche Anteil haben diese am Umsatz und vor allem wie reagieren die
Kunden auf das vielfältige Angebot? Diese Fragen und mehr gilt es in dieser
Bachelorthesis "Optometrische Dienstleistungen - state-of-the-art im deutschsprachigen
Raum" zu erörtern.
Um Aufschluss über all diese Fragen zu bekommen wird eine Befragung
verschiedener Augenoptiker in Deutschland durchgeführt. Anhand deren
Ergebnisse werden wichtige Erkenntnisse über den aktuellen Stand der
Augenoptiker und deren Einstellung im Bereich optometrische Dienstleistungen
gemacht. Optometrische Dienstleistungen tragen noch nicht bedeutend zum
Umsatz und Gewinn bei, was sich aber in Zukunft ändern wird, dafür erbring es
dem Augenoptiker einen Imagegewinn und die Absetzung von Mitbewerbern und
dem Onlinehandel. Aber vor allem aufgrund der Kundenbindung sind optometrische
Dienstleistungen für die Augenoptiker so interessant.
Purpose: Usually, a theory of attention upon gazed-at locations is applied. More parameters than gaze location can be derived to improve the theory of attention allocation. The aim of this study was to identify parameters related to eye tracking, that are suitable indicators of attention.
Methods: Binocular eye tracking data was collected with the Eye Tribe tracking system (The Eye Tribe Aps, Copenhagen, Denmark) for the task of visual exploration of the painting “Unexpected Visitors” by Ilya Repin. 20 subjects (valid data: 19/20) had to look at this painting for about two and a half minutes in order to generate fatigue and inattention. In a second step, suitable parameters of attention were transferred to a data set (8 subjects, valid data: 6/8) on a perimetric task executed with the OCTOPUS 900 perimeter (Haag-Streit, Köniz, Switzerland). Monocular parameters could be applied on the perimetric task, the error rate (false positive and false negative catch trials, 5 % each) were taken as additional parameter.
Results: For the image viewing task, the only parameter showing significance was the average level (a10) of fatigue waves (p = 0.00024, ANOVA, ∆ = -0.8316 px). Blink duration (∆ =-270.4 ms), pupil variability (∆ = -0.17868), saccade length (∆ =-0.3135 px) and fixation duration (∆ = 186.5 ms) did not change significantly, but showed relevant trends by differences ∆ of their median between the first and last tenth of the recording time. Blink rate and the Index of Cognitive Activity (ICA) did neither show significant changes nor relevant trends. Vergence accuracy failed to indicate fatigue due to variability between subjects and comparatively small effect size. For the perimetric data, in 3 of 6 subjects fatigue waves over a limited time window could be observed. Only for one subject, a relevant increase in false negative responses to catch trials (50 percentage points) could be observed.
Conclusion: Pupil diameter variability, saccade length, fixation duration and fatigue waves were the parameters indicating fatigue. Only the latter parameter has the potential to be applied to perimetric data.
Der positive Versorgungseffekt digitaler Gesundheitsanwendungen bei onkologischen Erkrankungen am Beispiel des Mammakarzinoms kann anhand onkologischer Leitlinienempfehlungen abgeleitet werden. Existieren bereits Studien zu Gesundheitsanwendungen mit positivem Versorgungseffekt, können die behandelten Funktionen als evidenzbasierter Ansatz verwendet werden. Betreffen diese Studien andere Krankheiten, sind diese Untersuchungen nicht auszuschließen. Ein positiver Versorgungseffekt könnte sich dennoch bei Brustkrebspatient:innen zeigen. Hier besteht in jedem Fall Forschungsbedarf. Bei der Umsetzung der Leitlinienempfehlungen mittel App sollte darauf geachtet werden, ob die Empfehlungen allein durchführbar sind oder ob dafür professionelle persönliche Unterstützung nötig ist. Je nach Ergebnis wird entschieden, ob die Empfehlung digital umsetzbar ist oder nicht.
„The secret of getting ahead is getting started.“ (Mark Twain)
Die Augenoptik-Branche befindet sich bedingt durch technische Innovationen und Fortschritte im Umbruch. Die vorliegende Bachelorthesis gibt einen Überblick über die aktuelle Situation der Optometrie in Deutschland und zeigt Potenziale auf, die die fortschreitende Digitalisierung Optometristen in Großbritannien und in den USA bietet.
In dieser Bachelorthesis werden die auf Basis von Recherchen und Experteninterviews im UK Foresight Project Report zusammengefassten Ergebnisse auf den deutschen Markt hinsichtlich Beratung Verkauf, Refraktion und optometrische Untersuchungen sowie Kontaktlinsenanpassung und Low Vision übertragen. So werden in dieser Bachelorthesis akkommodationsfähige Kontaktlinsen, Gadgets zur Selbstrefraktion und auch Neuerungen wie E-Health genauer betrachtet.
U. a. wird in der vorliegenden Thesis auf die folgenden
Fragen näher eingegangen: Welche Trends sind für die Augenoptik-Branche in Deutschland relevant? Mit welchen technischen und prozessorientierten Innovationen ist in den kommenden Jahren zu rechnen und welche Möglichkeiten bieten die Innovationen im Zusammenspiel mit der Digitalisierung dem einzelnen Augenoptiker und Optometristen? Woran muss der Augenoptiker in Deutschland verstärkt arbeiten, um auch zukünftig im Markt erfolgreich sein?
Eine Erkenntnis ist: Zur Erzielung von Wettbewerbsvorteilen gegenüber Filialisten und Online-Brillenhändlern kann die
Optometrie für selbstständige Augenoptiker zu einem wichtigen Differenzierungsmerkmal werden. Anhand des UK-Foresight Project Reports und der vorliegenden Bachelorarbeit wird deutlich, wie wichtig das frühzeitige Erkennen der insbesondere durch die Digitalisierung möglichen Veränderungen und der damit verbundenen Chancen und Risiken ist, um auch zukünftig erfolgreich zu sein. Die Veränderungen müssen angepackt und genutzt werden, um in der Flut der Digitalisierung und der Innovationen nicht unterzugehen.
This research project is of particular importance since there is a lack of adequate data on pediatric eye and vision disorders in Russia, particularly in the Volga region. In the present study, we estimate the prevalence of vision disorders among school-aged children who participated in a vision screening program in Samara, Russia. The relationship between learning-related visual dysfunctions is explored in depth, such to illustrate the connection between vision and learning. Hence, a key feature in this study is the inclusion of binocular vision disorders among the conditions tested.
Ein optometrisches Visualtraining wird in der Funktionaloptometrie eingesetzt, um visuelle Funktionsstörungen zu verbessern oder zu beheben. Außerdem wird es unter anderem in der Sportoptometrie und zur visuellen Rehabilitation angewendet. In Fachkreisen wird Visualtraining kontrovers diskutiert und die wissenschaftliche Belegbarkeit des Öfteren angezweifelt. Ziel dieser Bachelorthesis ist es, den aktuellen Stand des Visualtrainings abzubilden.
Das Ziel dieser Arbeit ist es, zu überprüfen, ob die optische Korrektur einer hydrophilen Freiformkontaktlinse bei Keratokonus durch einen zusätzlichen peripheren quadranten-spezifischem Anteil verbessert und zentrale Freiformflächen zu designen, berechnen, drehen und anzupassen. Diese Linse wird anschließend im Vergleich mit einer Linse mit identischer Freiform, aber ohne peripheren quadrantenspezifischen Anteil in Bezug auf das Sitz-und Zentrierverhalten und einer idealerweisesphärischen Vorderfläche untersucht. Jeweils zwei baugleichehydrophile Freiformkontaktlinsen mit und ohne peripherem quadrantenspezifischem Anteil werden mit gleichem sphärischem Vorderflächendesign und mit identischen Stabilisationszonen berechnet (Softwareentwicklung sagreader, HS Aalen). Alle Freiform-Kontaktlinsen für den Keratokonuspatienten werden mit einer Diamantdrehmaschine mit fast oscillation tool gefertigt (DAC Intl, USA). Mit Hilfe der Pentacam HR (Oculus, Wetzlar) werden Scheimpflugaufnahmender linsenfreien Hornhaut des Probanden, sowie Topographien mit den gefertigten Kontaktlinsenauf dem Augegemacht. Aus den ermittelten Datenwird mit einem Differenzprogramm (Matlab, Softwareentwicklung HS Aalen) die Abweichung der Scheiteltiefen von der besten Sphäre berechnet und graphisch dargestellt. Das Ergebnis zeigt, dass die Abweichung(„Oszillation“)der Vorderfläche von der besten Sphäre bei den Linsen mit zentraler Freiformrückfläche und ohne quadranten-spezifisch emperipherem Anteil im Vergleich zur Vorderfläche der Hornhaut des Probanden sich von 0,23 mm auf 0,18 mm reduziert. Bei den Linsen mit peripherem quadrantenspezifischem Anteil jedoch ist eine deutliche Erhöhung der irregulären Vorderflächenverformung festzustellen.
Als Schlussfolgerung der Pilotstudie ergibt sich, dass eine zusätzliche periphere quadrantenspezifische Rückflächengeometrie die optimale Korrektur durch die zentrale Freiformrückfläche nicht verbessern muss.
Üblicherweise findet, im Rahmen der subjektiven Refraktion, eine Bestimmung der
Sehschärfe beim Blick durch das Zentrum von Einstärkengläsern statt. Das Ergebnis
dieser Messung dient als Entscheidungskriterium bei der Auswahl der Glasstärke
der jeweiligen Korrektion. Umgekehrt ist der erzielbare Visus ein wichtiges Maß
hinsichtlich der Beurteilung der Qualität einer Sehhilfe.
Da einige der heute verfügbaren Sehhilfen nicht nur eine Stärke besitzen ist es
besonders interessant die Sehschärfe nicht nur beim Blick durch das Zentrum
des Glases zu beurteilen, sondern unter verschiedenen Blickwinkeln zu ermitteln.
Die Leuchtdichte spielt in der Lichttechnik eine zentrale Rolle. Die korrekte
Bestimmung der Leuchtdichte ist wichtig, allerdings messtechnisch anspruchsvoll. Die Arbeit beschreibt die Kalibrierung einer handelsüblichen CCD-Spiegelreflexkamera, um mit dieser Leuchtdichtemessungen durchführen zu können. Für die Kalibrierung wird zunächst
eine Ulbricht-Kugel mit Hilfe eines Radiospektrometers charakterisiert. Anschließend werden Bilder der strahlenden Fläche der Ulbricht-Kugel bei verschiedenen Leuchtdichten und unterschiedlichen Kameraeinstellungen aufgenommen. Daraus kann der Zusammenhang zwischen Leuchtdichte und Grauwert des
aufgenommenen Bildes hergestellt werden und eine Formel zur Berechnung der
Leuchtdichte aus dem Grauwert ist bestimmbar. Um die Bilder bequem auswerten zu können, wird ein Programm unter Visual Basic geschrieben.
Das Programm bestimmt die Leuchtdichte für alle Pixel im Bild und stellt das Bild anschließend für mehrere Leuchtdichtebereiche in Falschfarben dar. Mit dem
Mauszeiger kann der Grauwert und die Leuchtdichte punktuell abgerufen werden. Zudem berechnet das Programm aus einem manuell eingegebenen Grauwert die Leuchtdichte. Eine Anzeige in Originalgröße oder eine Ausschnittvergrößerung des Bildes sind möglich. Zur Anzeige der Leuchtdichte stehen drei verschiedene Skalen zur Verfügung.
Die Lautheitsskalierung verwendet sowohl Schmalband- als auch Breitbandsignale. Funktionselemente wie beispielsweise die Störschallunterdrückung reagieren auf Rauschen und reduzieren die Verstärkung. Das Ziel dieser Arbeit ist herauszufinden, wie Hörsysteme und ihre Funktionselemente auf schmalbandige Testsignale bei entsprechenden Frequenzen und Pegeln reagieren.
Es wurden vier Hörsysteme von zwei Herstellern, je ein High-
und ein Low-End-Gerät untersucht, die mit drei Konfigurationen der Funktionselemente ausgestattet waren, nämlich AUS(Adaptive Funktionselemente ausgeschaltet, AN (vom Hersteller empfohlene Einstellung der Funktionselemente) und SU (nur Störschallunterdrückung aktiviert). Bei fünf Frequenzen und sechs Eingangspegeln wurde das Verhalten der Hörsysteme auf Terzbandrauschen gemessen. Anhand des Zeitverlaufs der Ausgangspegel ließ sich die Reduktion des Ausgangsschalldruckpegels errechnen. Dabei wurden Anfangs- und Endpunkt der Änderung gemessen und die Ausgangspegel mit und ohne Funktionselementen bei 2 Sekunden (s) verglichen. Jedes Hörsystem reduzierte den
Ausgangspegel, abhängig von Eingangspegel und eventuell Frequenz. Bei Phonak reduzierten die Funktionselemente die Ausgangspegel bei 2s nicht, bei Siemens allerdings reduzierten sie diese bei einigen Messungen um einige Dezibel. Als Schlussfolgerung ergibt sich, dass Hörsysteme
auf Signale der Lautheitsskalierung unterschiedlich reagieren und dass Funktionselemente und Signaleigenschaften, und zwar Frequenz und Eingangspegel,
eine wichtige Rolle für ihre Reaktion spielen.
In Branchen wie Luftfahrt, Hotellerie oder Autovermietungen gehört «Revenue-Marketing» (kurz: RM) in Form von dynamischer Preisgestaltung schon lange zum angewendeten Standard. Ziel dieser Studie ist herauszufinden, wie die Haltung der schweizerischen Augenoptikerbranche gegenüber «Revenue-Marketing» ist. Es wird analysiert, wie viele Augenoptikfachgeschäfte in der Schweiz dynamische Preise anwenden und wie viele diese nicht anwenden. Es wird analysiert, wie die dynamischen Preise gesteuert werden und welche Produkte betroffen sind. Werden noch keine dynamischen Preise verwendet, wird nachgefragt, ob eine mögliche Einführung geplant ist. Sofern keine Einführung geplant ist, werden die Ablehnungsgründe analysiert. Zudem wird geforscht, ob die Firmengrösse einen Einflussfaktor auf die Verwendung von «Revenue-Marketing» hat.
Die Stiftung „Focus on Vision“ hat nach dem Prinzip der Alvarezlinsen Sehhilfen mit variabler Stärke entwickelt – die Focusspec-Brillen. Diese werden vor allem in Entwicklungsländern eingesetzt, um die Bevölkerung schnell und effektiv mit einer Korrektion zu versorgen. Es gibt zwei verschiedene Ausführungen, eine mit einstellbaren positiven Brechwerten (von 0,5 dpt bis 4,5 dpt) und eine mit einstellbaren negativen Brechwerten (von -1,0 dpt bis -5,0 dpt).
In dieser Arbeit wurden diese Sehhilfen mit einem Scheitelbrechwertmesser vermessen und die auftretenden Aberrationen genauer betrachtet.
Da in der realen Gebrauchssituation Blickbewegungen durch den Brillenträger stattfinden, wurden die Alvarezlinsen im Hinblick auf den Augendrehpunkt vermessen. Dazu wurde an der Hochschule Aalen ein Messaufsatz konzipiert, der sich an einem handelsüblichen Scheitel-brechwertmesser anbringen lässt. Dieser Aufsatz lässt sich schwenken, sodass die Messungen den Blickbewegungen um den Augendrehpunkt entsprechen. Die Messungen wurden für ein Blickfeld von 40° (±20°) durchgeführt. Dazu wurde auf den Gläsern ein Bereich über 9x9 Messpunkte vermessen, die jeweils in einem Abstand von 5° zueinander liegen.
Zunächst wurden die Brechwerte einer Sehhilfe für eine jeweilige Einstellung von ±4 dpt bestimmt. Die Schwankungsbreite der Sehhilfe mit -4 dpt (+4 dpt) liegt bei 0,0265 dpt (0,0797 dpt). Außerdem zeigen sich ein Astigmatismus und ein Refraktionsfehler, die durch die schrägen Blickwinkel verursacht werden. Wie zu erwarten, nehmen diese Aberrationen mit steigendem Blickwinkel zu. Der maximale Betrag des Astigmatismus liegt bei 0,40 dpt und der maximale Refraktionsfehler bei 0,52 dpt. Die Auswertung wurde über den Bereich eines Blickwinkels von ±10° gemacht.
Im Vergleich sind die Aberrationen der Focusspec-Brille mit dem positiven Brechwert größer als bei der Focusspec-Brille mit dem negativen Brechwert. Auch die größere Schwankungsbreite der Brille mit positivem Brechwert weist darauf hin, dass die verschiedenen Glasformen der Alvarezlinsen einen Einfluss auf die Abbildungsqualität haben könnten. Für eine detaillierte Betrachtung wird in dieser Bachelorarbeit zum ersten Mal eine Annäherung der Messergebnisse von Alvarezlinsen an diese sagittalen und tangentialen Bildschalen versucht. Vergleicht man alle Ergebnisse mit klassischen sphärischen Brillengläsern, zeigt sich, dass die Aberrationen der Alvarezlinsen vor allem am Rand größer sind. Dennoch ist die Art der Aberrationen vergleichbar mit denen der sphärischen Gläser.
Die Six Sigma-Methodik hilft Unternehmen als strategisches Marketing-Tool die Qualität der Produkte und Prozesse durch den Einsatz von statistischen Werkzeugen und fundierten Prozessoptimierungsmethoden zu verbessern, die Kunden zufriedener zu machen und die Abläufe im Unternehmen zu beschleunigen. Ziel der Arbeit ist es herauszufinden, ob sich dieses Qualitätsmanagement-Konzept auch auf die Gegebenheiten, Prozesse und Anforderungen in einem augenoptischen Betrieb wirksam anwenden lässt. In fünf klar definierten Projektphasen werden unter anderem durch die Erhebung, Analysierung und Auswertung von prozessbezogenen Daten Schwachstellen in betrieblichen Abläufen faktenbasiert offengelegt und fundiert verbessert. Ziel ist es, die Fehlerquote eines Prozesses auf ein Maß zu reduzieren, so dass von einer (annähernden) Null-Fehler-Qualität gesprochen werden kann. Die statistische Basis der Six Sigma-Methodik findet sich in der Tatsache begründet, dass alle betrieblichen Vorgänge einer Streuung vom statistischen Maß des „Soll-Wertes“ (Mittelwert μ) unterliegen, die sich durch eine Gauß’sche Normalverteilungskurve beschreiben lassen. Diese Streuungen (hier als Varianz oder Standardabweichung (σ) bezeichnet) sind als „Ist-Werte“ am Ende eines Prozesses zu verstehen. Um die Leistung eines Prozesses beurteilen zu können wird geprüft, wie oft die errechnete Standardabweichung zwischen den Zielwert und die Spezifikationsgrenzen passt. Die Anzahl stellt den Sigma-Wert des Prozesses dar. Die zentrale Aufgabe dieser Thesis ist es, darzulegen ob ─ und wenn ja ─ wie die Six Sigma-Methodik für kleine und mittlere Unternehmen im augenoptischen Fachbetrieb effektiv und sinnvoll zu implementieren ist. Die Recherchen und Analysen der Arbeit kommen diesbezüglich zu dem Ergebnis, dass Six Sigma durchaus eine Option für ein augenoptisches Unternehmen darstellen kann, das qualitative Niveau von Prozessen und Dienstleistungen zu heben. Jedoch bedarf es besonderer Sorgfalt bei der Auswahl geeigneter Prozesse und einer detaillierten Kosten-Nutzen-Aufstellung um mit Six Sigma effizient zu arbeiten und nachhaltigen Erfolg zu haben.
Sprachverstehen von unilateral versorgten CI-Träger*innen in alltagsrelevanten Hörsituationen
(2020)
CI-Träger*innen haben trotz gutem Sprachverstehen in Ruhe weiterhin Schwierigkeiten in geräuschvollen Situationen. Richtmikrofone können das Sprachverstehen in Situationen mit Hintergrundgeräusch verbessern.
Bisherige Studien fanden in stark vereinfachten Umgebungen statt und sind nicht auf Alltagssituationen übertragbar.
Diese Arbeit beinhaltet ein Teil der Untersuchungen, einer im Implant Centrum Freiburg durchgeführten Studie zum Nutzen von Richtmikrofon-Technologien für das Sprachverstehen in akustisch simulierten Hörumgebungen.
Zweck: Das Ziel dieser Studie ist es die Wahrnehmung und Akzeptanz von Unschärfe beim seitlichen Blick durch ein Gleitsichtglas zu untersuchen. Mit dem Blurtest sollte eine geeignete Methode zur Messung von Sehbereichsbreiten bei Gleitsichtgläsern entwickelt und verifiziert werden.
Material/Methoden: Die horizontalen Sehbereichsbreiten von vier Gleitsichtgläsern unterschiedlicher Progressionskanalbreite (2, 3, 4 und 5 mm) und linearem Wirkungsanstieg sollten bei einem Beobachtungsabstand von 40 cm für drei Unschärfekriterien gemessen werden. Die Grenzen für bemerkbare, tolerierbare und unakzeptable Unschärfe werden für einen am Bildschirm dargebotenen sinnfreien Text in Schriftgrad 9 pt (Visus = 0,4) links und rechts des monokularen Blickfelds markiert. Zusätzlich sollte in einem Vortest (Pretest) nach diesen Kriterien verschwommener, gedruckter Text beurteilt werden.
Ergebnisse: Die Grenzen für eben bemerkbare, tolerierbare und unakzeptable Unschärfe liegen bei einem Astigmatismus in Gebrauchsstellung von 0,70 ±0,3 dpt, 1,37 ±0,50 dpt und 2,06 ±0,74 dpt bei einem natürlichen Pupillendurchmesser von durchschnittlich 3,37 mm. In 40 % der Fälle unterscheiden sich die Grenzen für Unschärfe innerhalb eines Probanden nicht signifikant. Es besteht ein Zusammenhang zwischen der Toleranzbereitschaft unscharfe Texte in Alltagssituationen zu lesen und der Beurteilung von modifiziertem, gedrucktem Text.
Fazit: Die markierten Sehbereichsbreiten korrelieren mit dem horizontalen Anstieg des unerwünschten Astigmatismus, lassen sich bei Wiederholungsmessungen am Blurtest jedoch nicht auf ≤ 2° Schwankungsbreite reproduzierbar nachweisen. Die Definition, Wahrnehmung und Toleranz von Unschärfe in verschiedenen Alltagssituationen hängen von individuellen Erfahrungswerten und gesetzten Anspruch an Seh- bzw. Leseleistungen ab.
Das Auftreten einer Unverträglichkeit von Gleitsichtgläsern und die damit verbundene Unzufriedenheit werden in augenoptischen Kreisen kritisch diskutiert. Im deutsch-sprachigen Raum liegt bislang noch keine wissenschaftlich fundierte Datenbasis vor, die eine dauerhafte Unverträglichkeit von Gleitsichtgläsern belegt. Die vorliegende Arbeit soll aufzeigen, ob ein unzufriedener Gleitsichtbrillenträger durch eine optimale Versorgung mit für ihn individuell angefertigten Gleitsichtgläsern zu einem zufriede-nen Gleitsichtbrillenträger werden kann. Somit soll geklärt werden, ob die Unzufrie-denheit die Folge einer unabänderlichen Charakteristik des Brillenträgers ist, Gleit-sicht nicht zu vertragen. Zudem soll geprüft werden, wie groß der Einfluss bestimmter Bereiche des Sehens im Gleitsichtglas auf die Gesamtzufriedenheit ist und ob dieser sich abhängig vom Sehbereich unterscheidet. Dafür wurde im Zeitraum von Februar 2014 bis Juni 2015 eine multizentrische Studie mit 243 Probanden durchgeführt. Die Befragung zeigte, dass eine Steigerung der Gesamtzufriedenheit von 38,69 % er-reicht werden konnte. Am Ende der Testphase betrug die durchschnittliche Gesamt-zufriedenheit einen Wert von 81,25 %, welcher in die Kategorie der Zufriedenheit fällt. Von den 243 Probanden gaben 81,5 % an, dass ihre neue Gleitsichtbrille besser sei als ihre vorherige. Die Ergebnisse sprechen dafür, dass die Unzufriedenheit mit Gleitsicht keine unabänderliche Charakteristik ist, sondern mit einer optimalen Ver-sorgung die Zufriedenheit gesteigert werden kann. Hinsichtlich der Frage, welche Sehbereiche die Gesamtzufriedenheit am meisten beeinflussen, hat sich herausge-stellt, dass die Empfindung der Sehfeldbreite des mittleren Bereichs die größte Kor-relation mit der Gesamtzufriedenheit aufweist (0,803). Bezüglich der Sehqualität wurde die höchste Korrelation mit dem Sehen in der Nähe festgestellt (0,708). Gene-rell stellte sich heraus, dass Sehbereiche für nahe und mittlere Entfernungen einen größeren Einfluss auf die Gesamtzufriedenheit haben als Sehbereiche für weite Ent-fernungen. Auch hat sich gezeigt, dass die Empfindung der Sehfeldbreiten eine grö-ßere Auswirkung auf die Gesamtzufriedenheit hat als die Sehqualität in den entspre-chenden Bereichen.
Das Ziel dieser Bachelorthesis ist es, mit verschiedenen Messmethoden das Verhalten von Kunststoffen und Horn bei Wärmezufuhr zu untersuchen und zu analysieren.
Die Ergebnisse sollen die Verarbeitung von diesen Werkstoffen im augenoptischen Fachgeschäft erleichtern.
Es wurden drei Versuchsreihen durchgeführt. Im ersten Versuchsteil wurde untersucht, wie ein Material sich bei einer konstanten Wärmezufuhr in Abhängigkeit von der Zeit verhält. In der zweiten Messreihe wurde das Abkühlverhalten von Werkstoffen dokumentiert. Im letzten Versuchsteil wurde untersucht, ob sich das Material auch gleichmäßig erwärmen lässt.
Des Weiteren wurde das thermische Verhalten von Zelluloseacetat in zwei verschiedenen Farben miteinander verglichen und analysiert.
Das Verhalten von Horn bei Wärmezufuhr und sein Abkühlverhalten wurden bei 120 °C und 160 °C untersucht.
Die Untersuchungen zeigen, dass vor allem Kunststoffe und Horn sich in ihrem thermischen Verhalten voneinander unterscheiden. Bei Kunststoffen gab es nur kleinere Abweichungen voneinander. PA wird schneller warm und CA lässt sich gleichmäßiger erwärmen. Sowohl PA als auch CA Fassungen konnten die vorgegebene Temperatur innerhalb von 25 min nicht erreichen.
Die Hornfassung erwärmte sich schneller und erreichte sowohl bei 120 °C, als auch bei 160 °C die Temperatur in vorgegebener Zeit. Die Umgebungstemperatur beim Abkühlen wurde von beiden Kunststoffen nicht erreicht.
Horn erreichte die Umgebungstemperatur.
Die Streifenprojektion hat sich im Laufe der letzten Jahre schnell neben den Koordinatenmessgeräten in der 3D-Messtechnik etabliert und ist aus diesem Bereich nicht mehr wegzudenken. Auch auf anderen Gebieten, wie beispielsweise der Medizin oder der Automobilindustrie, findet diese im Alltag Anwendung. Ein entscheidender Vorteil der Streifenprojektion besteht darin, Objekte schnell und berührungslos zu vermessen.
In der vorliegenden Bachelorarbeit wird detailliert auf ein selbstentwickeltes Streifenprojektionsgerät eingegangen, dass mit geringen finanziellen Mitteln konstruiert wurde. Hierbei wurde die Software zur Steuerung der Komponenten sowie zur Auswertung der erfassten Daten in Matlab erstellt.
Das Gerät wurde auf Benutzerfreundlichkeit untersucht und hinsichtlich dieses Aspektes verbessert. Im Zuge dessen beinhaltet die Bachelorthesis eine ausführliche Benutzeranleitung für Neuanwender.
Durch Transformation der Kalibrierung in metrische Daten kann das Streifenprojektionsgerät für zukünftige Messungen benutzt werden.
Es konnten die Fragen geklärt werden, wie reproduzierbar die Ergebnisse des Messgerätes sind und welche Messgenauigkeit erzielt werden kann. Zusätzlich erfolgte die Definition des erreichbaren Messvolumens.
Die Auswertung der durchgeführten Messversuche zeigte, dass das Gerät reproduzierbare Ergebnisse liefert. Außerdem konnte gezeigt werden, dass das Streifenprojektionsgerät in der Lage ist einfache Freiformflächen zu vermessen. Die erzeugten Messdaten können beispielsweise als Solldaten für die Vermessung mit taktilen Messmaschinen verwendet werden. Oberflächen welche scharfe Kanten, also nicht stetige Strukturen, besitzen, können mit diesem Aufbau nicht vermessen werden
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Purpose: The aim is to be able to advise patients on the choice of sports and exercises regarding the effects on the intraocular pressure.
Methods: The search engines Google Scholar and PubMed were used to search for suitable studies. The studies were summarized, and the most important data were collected in one table for each study. The effect on the IOP was extracted or, if not given in the article, calculated by the difference of means of the IOP after or during exercise, and the baseline IOP before, whenever these values were available.
Findings: A total of 47 studies out of the years 1990 to 2020 that investigated the influence on the IOP of the most popular sports actively practiced in Germany were reviewed and summarized: twelve for running, sixteen for fitness/ weight training, one for swimming/diving, twelve for cycling, four for hiking, and two for yoga.
Conclusions: Throughout all studies and sports it was seen that physical fitness stabilized the IOP. Higher
intensity of exercise led to higher fluctuations of the IOP. Moderate endurance training keeps the IOP fluctuations low and may lead to a lower baseline IOP if practiced on a regular base. Fitness and weight training lead to fluctuations of the IOP in a pronounced manner when performed at moderate and high intensity. Therefore, only a moderate training can be recommended if there is need to keep the IOP stable. Isometric exercise is not recommended as it provokes a rise of the IOP even when performed with light loads. The Valsalva Maneuver should always be avoided as it leads to additional fluctuations of the IOP. Also, the IOP behaved more stable during resistance training when higher fitness was present.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.
Ziel der Arbeit:
Die Verwendung von Kompression in Hörsystemen ist heutzutage essenzieller Bestandteil jeder
Hörsystemanpassung. In vielen Forschungsprojekten wurde bis heute Hauptsächlich das
Augenmerk auf die Hochtonkompression gelegt, dabei gibt es nur wenige Studien die sich mit
der Tieftonkompression beschäftigen. In dieser Studie wurde gezielt mit der Kompression im
niederfrequenten Bereich von 160 - 800 Hz gearbeitet mit der Besonderheit, dass zusätzlich
Grenzfrequenzen im Bereich von 160 - 480 Hz und 640 - 800 Hz gesetzt wurden. Das Augenmerk
wurde dabei auf die Frage gelegt, ob definierte Grenzfrequenzen die zu Frequenzbändern
zusammengefasst werden das Sprachverstehen beeinflussen können?
Material und Methode:
An dieser Studie nahmen sieben Schülerinnen und Schüler teil. Die Schülerinnen und Schüler
nahmen freiwillig an der Studie Teil und durften die Teilnahme jederzeit beenden. Die
Teilnehmerinnen und Teilnehmer bekamen Testgeräte die in zwei verschiedenen Einstellungen
im Tieftonbereich mit einem CV von 2,5:1 eingestellt wurden. Dabei war Einstellung 1 mit
den Grenzfrequenzen 160 - 480 Hz und Einstellung 2 mit den Grenzfrequenzen 640 - 800 Hz
eingestellt. Jede Einstellung wurde jeweils eine Woche testgetragen und dann gemeinsam ausgewertet.
Ergebnisse:
Das bessere Sprachverstehen (Validierung durch den OlKiSa) wurde mit Einstellung 1 erreicht,
auch bei der allgemeinen Bewertung des Hörsystems in Alltagssituationen wurde Einstellung 1
besser bewertet als Einstellung 2.
Schlussfolgerung:
Vorausgehende Studien konnten belegen, dass die Tieftonkompression für hochgradig schwerhörige
im Tieftonbereich einen positiven Einfluss auf das Sprachverstehen haben. Des weiteren
konnte mit der vorliegenden Studie eine Tendenz nachgewiesen werden, dass Grenzfrequenzen
im Tieftonbereich ebenso positive Effekte erzielen können. Die Ergebnisse zeigen die Tendenz
zu den tieferen Frequenzen 160 - 480 Hz der Einstellung 1. Die Allgemeine Zufriedenheit und
der Tragekomfort der Hörsystemene für Einstellung 1 war ausschlaggebender als die Ergebnisse
für Einstellung 2.