Optik und Mechatronik
Refine
Year of publication
Document Type
- Bachelor Thesis (108)
- Conference Proceeding (70)
- Article (60)
- Patent (21)
- Master's Thesis (20)
- Book (8)
- Part of a Book (4)
- Report (4)
- Doctoral Thesis (2)
Language
- German (190)
- English (106)
- Multiple languages (1)
Keywords
- Abschlussarbeit (6)
- Augenoptik (5)
- Bachelorarbeit A/H (4)
- Leitfaden (4)
- Myopieprogression (3)
- Studie (3)
- Digitalisierung (2)
- FrACT (2)
- Gleitsichtgläser (2)
- Hörgerät (2)
Institute
- Optik und Mechatronik (297)
Myopie-Management
(2021)
Das Ziel dieser Bachelorarbeit ist es, einen Workflow für den Bereich Myopie-Management, anhand internationalen Guidelines zu erstellen. Für die verschiedenen Myopie-Management-Maßnahmen werden hierfür effiziente Musterprozesse herausgearbeitet. Diese sollen als Leitfaden dienen und für Augenoptiker*innen und Optometrist*innen, welche sich im Bereich Myopie-Management spezialisieren, ein erfolgreiches und zukunf tsfähiges Geschäftsmodell mit effizienten Arbeitsschritten generieren. Zudem sollen die Mindestanforderungen in Aus- und Weiterbildung, Ausstattung und Räumlichkeiten aufgezeigt werden, um ein detaillierten Überblick zu geben.
Entwicklung und Analyse einer Messmethode zur Bestimmung des individuellen Insets mittels Kamera
(2016)
In dieser Arbeit wird eine Messmethode zur Bestimmung der individuellen Pupillendistanz für den Nahbereich und des damit einhergehenden individuellen Insets entwickelt.
Bei der Methode handelt es sich um Kameramessungen in einer definierten Prüfdistanz von 400 mm. Die Fixation erfolgt auf eine Fixationsmarke, die zentrisch vor dem Kameraobjektiv angebracht ist. Je Messreihe werden zehn Einzelmessungen durchgeführt, deren Mittelwert für die weiteren Vergleiche herangezogen wird.
Die Methode wird durch verschiedene Messungen an insgesamt drei Probanden und einem Kunstkopf untersucht und deren Ergebnisse werden mittels Vergleichsmessungen traditioneller Messmethoden auf Plausibilität geprüft. Der Mittelwert über die Standardabweichungen der gemessenen Pupillendistanzen aller Messreihen beträgt 0,04 mm.
Im weiteren Verlauf werden verschiedene Korrekturfaktoren hergeleitet, die Messungenauigkeiten wie beispielsweise den perspektivischen Fehler ausgleichen. Die Abweichungen zwischen den aus diesen Messungen berechneten Insets und den geometrisch berechneten Insets liegen in einem Bereich von 0,05 mm bis 0,38 mm.
Die Ergebnisse aller Messungen zeigen zudem für die drei untersuchten Probanden einen kleineren binokularen Inset von 3,21 mm bis 4,18 mm auf als der für Standardgleitsichtgläser verwendete Inset von insgesamt 4,0 mm bis 5,0 mm.
Das Ziel der vorliegenden Thesis ist die Erarbeitung eines Leitfadens zur Anpassung von weichen individuellen Kontaktlinsen. Dabei werden auch die theoretischen Grundlagen betrachtet. In diesem Abschnitt wird besonders auf die Studien zur Anpassung über die Scheiteltiefe eingegangen. Um zu zeigen, welche Vorteile individuelle Kontaktlinsen haben, werden diese für den Kunden und den Augenoptiker in Bezug auf die Geometrie der Kontaktlinsen erläutert. Insgesamt soll die Thesis zur Orientierung für Studenten, Augenoptiker und Kontaktlinsenspezialisten bei der Anpassung von weichen individuellen Kontaktlinsen dienen.
The increasing prevalence of myopia throughout the industrialized world in recent decades has caused costs and problems for the eye health. Changed lifestyle and behavior are the main causes. For the pathogenesis of myopia, the amount of time spent outdoor and near activities play an important role. Various options for the treatment of myopia have been described as effective in the literature. Normal single vision glasses and contact lenses can only provide clear vision, but do not reduce myopia progression. Orthokeratology shows a slowing of axial growth, but has an increased risk of infectious keratitis. Low-dose atropine (0.01%) is currently the best pharmacological option. It proved safe, effective and showed the least rebound effect with negligible side effects. Other options for the treatment of myopia include special glasses, behavioral changes and prolonged outdoor exposure (to prevent the onset of myopia), as well as other methods. An increasingly important myopia management option is multifocal contact lenses, that provide a peripheral treatment zone producing myopic defocus. Such myopia control lenses are available as customized or as daily or monthly lenses. Children benefit from wearing contact lenses more than just having refractive error correction and myopia control, they have a better self-esteem and improved quality of life. The numerous findings on the safety and efficacy of soft multifocal distance center contact lenses in children to reduce the progression of myopia suggest that this modality should be considered as a main treatment option. Less, but similar to orthokeratology, when wearing soft lenses there is a risk of developing potentially serious complications such as microbial keratitis. The introduction of child-appropriate risk minimization strategies, and patient and parent education with regular monitoring is essential and leads to successful contact lens wear. This literature review summarized the actual knowledge about myopia management, prevalence, etiology and the visual and healthy consequences of myopia.
The three currently most important strategies for slowing the progression of myopia are soft multifocal distance center contact lenses, Orthokeratology and low-dose atropine ophthalmic drops.
Purpose: Usually, a theory of attention upon gazed-at locations is applied. More parameters than gaze location can be derived to improve the theory of attention allocation. The aim of this study was to identify parameters related to eye tracking, that are suitable indicators of attention.
Methods: Binocular eye tracking data was collected with the Eye Tribe tracking system (The Eye Tribe Aps, Copenhagen, Denmark) for the task of visual exploration of the painting “Unexpected Visitors” by Ilya Repin. 20 subjects (valid data: 19/20) had to look at this painting for about two and a half minutes in order to generate fatigue and inattention. In a second step, suitable parameters of attention were transferred to a data set (8 subjects, valid data: 6/8) on a perimetric task executed with the OCTOPUS 900 perimeter (Haag-Streit, Köniz, Switzerland). Monocular parameters could be applied on the perimetric task, the error rate (false positive and false negative catch trials, 5 % each) were taken as additional parameter.
Results: For the image viewing task, the only parameter showing significance was the average level (a10) of fatigue waves (p = 0.00024, ANOVA, ∆ = -0.8316 px). Blink duration (∆ =-270.4 ms), pupil variability (∆ = -0.17868), saccade length (∆ =-0.3135 px) and fixation duration (∆ = 186.5 ms) did not change significantly, but showed relevant trends by differences ∆ of their median between the first and last tenth of the recording time. Blink rate and the Index of Cognitive Activity (ICA) did neither show significant changes nor relevant trends. Vergence accuracy failed to indicate fatigue due to variability between subjects and comparatively small effect size. For the perimetric data, in 3 of 6 subjects fatigue waves over a limited time window could be observed. Only for one subject, a relevant increase in false negative responses to catch trials (50 percentage points) could be observed.
Conclusion: Pupil diameter variability, saccade length, fixation duration and fatigue waves were the parameters indicating fatigue. Only the latter parameter has the potential to be applied to perimetric data.
Die Lautheitsskalierung verwendet sowohl Schmalband- als auch Breitbandsignale. Funktionselemente wie beispielsweise die Störschallunterdrückung reagieren auf Rauschen und reduzieren die Verstärkung. Das Ziel dieser Arbeit ist herauszufinden, wie Hörsysteme und ihre Funktionselemente auf schmalbandige Testsignale bei entsprechenden Frequenzen und Pegeln reagieren.
Es wurden vier Hörsysteme von zwei Herstellern, je ein High-
und ein Low-End-Gerät untersucht, die mit drei Konfigurationen der Funktionselemente ausgestattet waren, nämlich AUS(Adaptive Funktionselemente ausgeschaltet, AN (vom Hersteller empfohlene Einstellung der Funktionselemente) und SU (nur Störschallunterdrückung aktiviert). Bei fünf Frequenzen und sechs Eingangspegeln wurde das Verhalten der Hörsysteme auf Terzbandrauschen gemessen. Anhand des Zeitverlaufs der Ausgangspegel ließ sich die Reduktion des Ausgangsschalldruckpegels errechnen. Dabei wurden Anfangs- und Endpunkt der Änderung gemessen und die Ausgangspegel mit und ohne Funktionselementen bei 2 Sekunden (s) verglichen. Jedes Hörsystem reduzierte den
Ausgangspegel, abhängig von Eingangspegel und eventuell Frequenz. Bei Phonak reduzierten die Funktionselemente die Ausgangspegel bei 2s nicht, bei Siemens allerdings reduzierten sie diese bei einigen Messungen um einige Dezibel. Als Schlussfolgerung ergibt sich, dass Hörsysteme
auf Signale der Lautheitsskalierung unterschiedlich reagieren und dass Funktionselemente und Signaleigenschaften, und zwar Frequenz und Eingangspegel,
eine wichtige Rolle für ihre Reaktion spielen.
In Branchen wie Luftfahrt, Hotellerie oder Autovermietungen gehört «Revenue-Marketing» (kurz: RM) in Form von dynamischer Preisgestaltung schon lange zum angewendeten Standard. Ziel dieser Studie ist herauszufinden, wie die Haltung der schweizerischen Augenoptikerbranche gegenüber «Revenue-Marketing» ist. Es wird analysiert, wie viele Augenoptikfachgeschäfte in der Schweiz dynamische Preise anwenden und wie viele diese nicht anwenden. Es wird analysiert, wie die dynamischen Preise gesteuert werden und welche Produkte betroffen sind. Werden noch keine dynamischen Preise verwendet, wird nachgefragt, ob eine mögliche Einführung geplant ist. Sofern keine Einführung geplant ist, werden die Ablehnungsgründe analysiert. Zudem wird geforscht, ob die Firmengrösse einen Einflussfaktor auf die Verwendung von «Revenue-Marketing» hat.
Neben der subjektiven Bewertung der Hörsystemanpassung durch die Kunden und die Verifikation durch die Akustikerin/den Akustiker, in der Regel insitu, ist auch die Validierung einer Hörsystemanpassung nötig bzw. vorgeschrieben.
Der in der Hörgeräteakustik verbreitetste Test, um das Sprachverstehen zu testen, ist auch weiterhin der Freiburger Sprachtest.
Dieser findet nicht nur Anwendung bei Akustikerinnen und Akustikern, sondern auch bei HNO Ärztinnen und Ärzten. Somit ist er aus der Praxis nicht wegzudenken.
Neben den bekannten Problemen der ungleichen Listen und der mangelnden Eignung des Freiburger Sprachtests für Messungen im Störschall, haben jedoch alle Sprachtests gemein, dass sie nur akustisch und nicht visuell dargeboten werden.
Viele Schwerhörige, auch HörgeräteträgerInnen, nutzen jedoch im realen Leben neben der reinen akustischen auch die visuelle Information über das Mundbild der Sprecherin / des Sprechers. Diese Zusatzinformation kann die subjektive Höranstrengung deutlich reduzieren.
In dieser Studie wurde die Sprachverständlichkeit (SV) im Freiburger Sprachtest im Freifeld mit und ohne Videomaterial bei insgesamt 22 Personen und 6 Normalhörenden untersucht.
Application of a robotic THz imaging system for sub-surface analysis of ancient human remains
(2019)
We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the sub-surface structure of human remains. The depth resolution of the THz images exceeds the resolution of a conventional CT scan and is comparable with a micro-CT scan. The advantage of THz measurements over micro-CT scans is the fact that even comparatively large samples, like complete bodies, can be scanned. These would not fit into a conventional micro-CT scanner.
Wideband-tympanometry (WBT) could give more informative data about the tympanic condition than the conventional tympanometry. In the actual literature, the clinical profit of wideband-tympanometry in pediatric audiological settings is not well evaluated. The aim of this study was to analyze the additional clinical benefit.