Refine
Year of publication
- 2015 (34) (remove)
Document Type
- Bachelor Thesis (22)
- Master's Thesis (7)
- Conference Proceeding (4)
- Article (1)
Keywords
- Studie (5)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Alvarezlinsen, Focusspec-Brille, Scheitelbrechwertmessung, Augendrehpunkt (1)
- Augenoptikgeschäft (1)
- Comparison metrics (1)
- Deflektometrie (1)
- EVA (1)
- Eye Tracking, Vigilanz, Aufmerksamkeit, visuelle Exploration, Perimetrie (1)
- Eye tracking (1)
- Fixation (1)
Institute
Purpose: Usually, a theory of attention upon gazed-at locations is applied. More parameters than gaze location can be derived to improve the theory of attention allocation. The aim of this study was to identify parameters related to eye tracking, that are suitable indicators of attention.
Methods: Binocular eye tracking data was collected with the Eye Tribe tracking system (The Eye Tribe Aps, Copenhagen, Denmark) for the task of visual exploration of the painting “Unexpected Visitors” by Ilya Repin. 20 subjects (valid data: 19/20) had to look at this painting for about two and a half minutes in order to generate fatigue and inattention. In a second step, suitable parameters of attention were transferred to a data set (8 subjects, valid data: 6/8) on a perimetric task executed with the OCTOPUS 900 perimeter (Haag-Streit, Köniz, Switzerland). Monocular parameters could be applied on the perimetric task, the error rate (false positive and false negative catch trials, 5 % each) were taken as additional parameter.
Results: For the image viewing task, the only parameter showing significance was the average level (a10) of fatigue waves (p = 0.00024, ANOVA, ∆ = -0.8316 px). Blink duration (∆ =-270.4 ms), pupil variability (∆ = -0.17868), saccade length (∆ =-0.3135 px) and fixation duration (∆ = 186.5 ms) did not change significantly, but showed relevant trends by differences ∆ of their median between the first and last tenth of the recording time. Blink rate and the Index of Cognitive Activity (ICA) did neither show significant changes nor relevant trends. Vergence accuracy failed to indicate fatigue due to variability between subjects and comparatively small effect size. For the perimetric data, in 3 of 6 subjects fatigue waves over a limited time window could be observed. Only for one subject, a relevant increase in false negative responses to catch trials (50 percentage points) could be observed.
Conclusion: Pupil diameter variability, saccade length, fixation duration and fatigue waves were the parameters indicating fatigue. Only the latter parameter has the potential to be applied to perimetric data.
Zweck: Das Ziel dieser Studie ist es die Wahrnehmung und Akzeptanz von Unschärfe beim seitlichen Blick durch ein Gleitsichtglas zu untersuchen. Mit dem Blurtest sollte eine geeignete Methode zur Messung von Sehbereichsbreiten bei Gleitsichtgläsern entwickelt und verifiziert werden.
Material/Methoden: Die horizontalen Sehbereichsbreiten von vier Gleitsichtgläsern unterschiedlicher Progressionskanalbreite (2, 3, 4 und 5 mm) und linearem Wirkungsanstieg sollten bei einem Beobachtungsabstand von 40 cm für drei Unschärfekriterien gemessen werden. Die Grenzen für bemerkbare, tolerierbare und unakzeptable Unschärfe werden für einen am Bildschirm dargebotenen sinnfreien Text in Schriftgrad 9 pt (Visus = 0,4) links und rechts des monokularen Blickfelds markiert. Zusätzlich sollte in einem Vortest (Pretest) nach diesen Kriterien verschwommener, gedruckter Text beurteilt werden.
Ergebnisse: Die Grenzen für eben bemerkbare, tolerierbare und unakzeptable Unschärfe liegen bei einem Astigmatismus in Gebrauchsstellung von 0,70 ±0,3 dpt, 1,37 ±0,50 dpt und 2,06 ±0,74 dpt bei einem natürlichen Pupillendurchmesser von durchschnittlich 3,37 mm. In 40 % der Fälle unterscheiden sich die Grenzen für Unschärfe innerhalb eines Probanden nicht signifikant. Es besteht ein Zusammenhang zwischen der Toleranzbereitschaft unscharfe Texte in Alltagssituationen zu lesen und der Beurteilung von modifiziertem, gedrucktem Text.
Fazit: Die markierten Sehbereichsbreiten korrelieren mit dem horizontalen Anstieg des unerwünschten Astigmatismus, lassen sich bei Wiederholungsmessungen am Blurtest jedoch nicht auf ≤ 2° Schwankungsbreite reproduzierbar nachweisen. Die Definition, Wahrnehmung und Toleranz von Unschärfe in verschiedenen Alltagssituationen hängen von individuellen Erfahrungswerten und gesetzten Anspruch an Seh- bzw. Leseleistungen ab.
Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Abstract
1.1 Purpose
The purpose of this study is to prescribe follicular-like conjunctivitis associated with Siliconhydrogels
(FoCoSi) in silicone hydrogel contact lens wearers as a novel subtype of
the well prescribed contact lens induced papillary conjunctivitis (CLPC).
1.2 Methods
1211 patients who wore silicon hydrogels were included in this prospective, nonrandomised,
single center study. Subjective symptoms and clinical signs were evaluated
for daily wear (DW) and continuous wear (CW) populations for several (Lotrafilcon A,
Lotrafilcon B, Senofilcon A, Galyfilcon A) silicon hydrogel lens types. CCLRU and other
specifically developed grading scale were utilized for evaluation. Grading of 2 and above
was rated as clinically significant. Statistical evaluation was performed for eyes rather
than subjects.
1.3 Results
The clinical presentation of FoCoSi could be confirmed and showed an incidence of
3.8%. Lotrafilcon A followed by Senofilcon A on a CW modality presented, with a risk
ratio of 2.49 and 1.53 respectively, the highest affinity for developing FoCoSi. Fluorescein
positive spots showed the closest correlation with subjective symptoms reported
by patients and divided FoCoSi into an active and dormant form. Besides Protein, Lipid
deposition on the contact lens surface and air pollution like Ozone or fine and ultrafine
particles seems to be important factors in developing FoCoSi, whereas mechanical irritation
played a minor role.
1.4 Conclusion
FoCoSi is a novel and relevant subtype of CLPC. Further studies should be performed
to validate these findings and clear up several questions about the aetiology of FoCoSi
and CLPC.
Keywords: Giant papillary conjunctivitis (GPC), contact lens-induced papillary conjunctivitis
(CLPC), follicular-like conjunctivitis associated with siliconhydrogels (FoCoSi)
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
Purpose
The purpose of this study was to investigate the correlation of measured visual acuity
(VA) both static and dynamic obtained with static and dynamic measuring tests, as well
as, response time to visual stimulus and analysis of its influence on dynamic visual
acuity. The aim was to compare the results gathered for the three age groups and
analyze the possible differences.
Methods
The test groups consisted of 75 subjects between 10 and 60 years old, categorized in
three age groups. The measurements of static and dynamic visual acuity and reaction
time were conducted. The set of nine tests (five with radial magnification speed and four
simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure
dynamic visual acuity and the set of two tests for reaction time measurement.
Results
Compared to static visual acuity in both tests, the results obtained with measurements
of dynamic visual acuity resulted in lower values depending on Landolt ring size and
magnification speed of animation. In average, the dynamic visual acuities in tests with
different magnification speeds were lower than static by 0.4 visual acuity units, or 31%
and the average of dynamic visual acuity after subtracting motoric component (reaction
time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating
driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while
at 130 km/h average drop for younger and middle age groups was 37% and for older
group was 44% and after subtracting motor component values for 72 km/h speed
simulation average drop in visual acuity values was 23% for all three groups; for 130
km/h speed simulation younger and middle aged group average drop of visual acuity
was 20% and with older group it was 24%.
Conclusion
The tests used in this study were simple and fast and revealed significant difference
between static and dynamic visual acuity and influence of reaction time on dynamic
Nataša Vujko Muždalo Abstract
2
visual acuity values. It is hoped that this thesis will be a positive contribution in testing
and training of dynamic visual and sensory response skill with drivers, sportsmen and
people with visual-motor dysfunction.
Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT),
motoric component, dynamic visual acuity test, reaction time test, radial increase in size
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).
Die Stiftung „Focus on Vision“ hat nach dem Prinzip der Alvarezlinsen Sehhilfen mit variabler Stärke entwickelt – die Focusspec-Brillen. Diese werden vor allem in Entwicklungsländern eingesetzt, um die Bevölkerung schnell und effektiv mit einer Korrektion zu versorgen. Es gibt zwei verschiedene Ausführungen, eine mit einstellbaren positiven Brechwerten (von 0,5 dpt bis 4,5 dpt) und eine mit einstellbaren negativen Brechwerten (von -1,0 dpt bis -5,0 dpt).
In dieser Arbeit wurden diese Sehhilfen mit einem Scheitelbrechwertmesser vermessen und die auftretenden Aberrationen genauer betrachtet.
Da in der realen Gebrauchssituation Blickbewegungen durch den Brillenträger stattfinden, wurden die Alvarezlinsen im Hinblick auf den Augendrehpunkt vermessen. Dazu wurde an der Hochschule Aalen ein Messaufsatz konzipiert, der sich an einem handelsüblichen Scheitel-brechwertmesser anbringen lässt. Dieser Aufsatz lässt sich schwenken, sodass die Messungen den Blickbewegungen um den Augendrehpunkt entsprechen. Die Messungen wurden für ein Blickfeld von 40° (±20°) durchgeführt. Dazu wurde auf den Gläsern ein Bereich über 9x9 Messpunkte vermessen, die jeweils in einem Abstand von 5° zueinander liegen.
Zunächst wurden die Brechwerte einer Sehhilfe für eine jeweilige Einstellung von ±4 dpt bestimmt. Die Schwankungsbreite der Sehhilfe mit -4 dpt (+4 dpt) liegt bei 0,0265 dpt (0,0797 dpt). Außerdem zeigen sich ein Astigmatismus und ein Refraktionsfehler, die durch die schrägen Blickwinkel verursacht werden. Wie zu erwarten, nehmen diese Aberrationen mit steigendem Blickwinkel zu. Der maximale Betrag des Astigmatismus liegt bei 0,40 dpt und der maximale Refraktionsfehler bei 0,52 dpt. Die Auswertung wurde über den Bereich eines Blickwinkels von ±10° gemacht.
Im Vergleich sind die Aberrationen der Focusspec-Brille mit dem positiven Brechwert größer als bei der Focusspec-Brille mit dem negativen Brechwert. Auch die größere Schwankungsbreite der Brille mit positivem Brechwert weist darauf hin, dass die verschiedenen Glasformen der Alvarezlinsen einen Einfluss auf die Abbildungsqualität haben könnten. Für eine detaillierte Betrachtung wird in dieser Bachelorarbeit zum ersten Mal eine Annäherung der Messergebnisse von Alvarezlinsen an diese sagittalen und tangentialen Bildschalen versucht. Vergleicht man alle Ergebnisse mit klassischen sphärischen Brillengläsern, zeigt sich, dass die Aberrationen der Alvarezlinsen vor allem am Rand größer sind. Dennoch ist die Art der Aberrationen vergleichbar mit denen der sphärischen Gläser.
Üblicherweise findet, im Rahmen der subjektiven Refraktion, eine Bestimmung der
Sehschärfe beim Blick durch das Zentrum von Einstärkengläsern statt. Das Ergebnis
dieser Messung dient als Entscheidungskriterium bei der Auswahl der Glasstärke
der jeweiligen Korrektion. Umgekehrt ist der erzielbare Visus ein wichtiges Maß
hinsichtlich der Beurteilung der Qualität einer Sehhilfe.
Da einige der heute verfügbaren Sehhilfen nicht nur eine Stärke besitzen ist es
besonders interessant die Sehschärfe nicht nur beim Blick durch das Zentrum
des Glases zu beurteilen, sondern unter verschiedenen Blickwinkeln zu ermitteln.
Diese Bachelorthesis beschreibt Gründungs- und Unternehmensführungsstrategie anhand einer handlungsorientierten und konstruktivistischen Lernstrategie VaKE (Value and Knowledge Education) zum Erlangen der beruflichen Handlungsfähigkeit. Dabei teilt sich die Arbeit in drei Hauptteile wie folgt auf: Im ersten Teil wird beschrieben welche Kompetenzen und Eigenschaften zusammen die berufliche Handlungsfähigkeit ergeben, und wie diese erworben werden kann. Weiterhin wird der geschichtliche Hintergrund von Qualifikationen und Handlungskompetenzen dargestellt. Im zweiten Teil dieser Bachelorthesis wird die Theorie zu den Gründungs- und Unternehmensführungsstrategien im Rahmen der allgemeinen Meisterprüfungsordnung (AMVO) herausgearbeitet und beschrieben. Dabei werden nach der AMVO im zweiten Handlungsfeld die Gründungs- und Übernahmeaktivitäten sowie das dritte Handlungsfeld der Unternehmensführungsstrategien genauer beschrieben. Das zweite Handlungsfeld gliedert sich in die Bedeutung der persönli-chen Voraussetzungen für den Erfolg der beruflichen Selbstständigkeit, die wirtschaftliche, gesellschaftliche und kulturelle Bedeutung des Augenoptiker Handwerks, der Nutzen von Handwerksorganisationen sowie Entscheidungen zum richtigen Standort eines Augenoptischen Betriebes. Das dritte Handlungsfeld beschreibt die Bestimmungen des Arbeits-und Sozialversicherungsrechts, Instrumen-te zur Durchsetzung von Forderungen sowie theoretischen Grundlagen zur Insolvenz und deren mögliche Konsequenzen. Der dritte Teil dieser Bachelorthesis setzt sich aus handlungsorientierten Aufgaben zu den Gründungs- und Unternehmensführungsstrategien zusammen, welche im zweiten Teil genau beschrieben wurden. Diese Aufgaben werden anhand der konstruktivistischen Lernstrategie VaKE durchgeführt.