Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Comparing axial eye length to other physiological properties of the eye, body height and the head
(2022)
Purpose: To find, if there is any relationship between axial eye length and other physiological properties of the eye (horizontal corneal diameter, average corneal radius, central corneal thickness, objective spherical equivalent, pupillary distance), body height, and head size. Can any of these correlations eventually complement models in myopia progression or be the model for further research.
In der Arbeit wurde eine GC-MS-Methode zur Quantifizierung von 21 identifizierten Aromastoffen, die aus getoasteten Eichenholzchips in Wein übergehen, entwickelt. Diese Methode wurde für die ausgewählten Substanzen unter Einbeziehung der Festphasenextraktion mittels des internen Standard 2-Octanol kalibriert. Die Analyte zeigten mit Ausnahme von Syringaaldehyd lineares Verhalten bei Korrelationen von 0,986 bis 0,999. Die Nachweisgrenzen, die über das Signal-zu-Rausch-Verhältnis ermittelt wurden, lagen im Bereich von 0,03 bis 0,47 µg/l. Der Test auf Wiederholbarkeit ergab mit Werten von kleiner 10% für die meisten untersuchten Stoffe in Rot- und Weißwein zufrieden stellende Werte. Mit der entwickelten Methode wurden Barriqueweine des Handels und selbst hergestellte Chipsweine untersucht. Bei der Untersuchung der Chipsweine, die nach einem vollen Versuchsplan hergestellt wurden, zeigten sich signifikante Einflüsse durch die Faktoren Kontaktzeit, Toastung und Größe sowie durch die Wechselwirkung Toastung-Größe auf die Konzentrationen der meisten identifizierten Substanzen. Bei der Betrachtung der Konzentrationen der ausgewählten Substanzen in Barriqueweinen zeigten sich signifikante Unterschiede zu den entsprechenden Konzentrationen in den hergestellten Chipsweinen. Diese signifikanten Unterschiede wurden mittels Hauptkomponentenanalyse und anschließender Klassifizierung über die SIMCA-Methode dazu genutzt, um die önolgischen Verfahren Chipsbehandlung und Barriquefasslagerung zu differenzieren.
Telemedicine assisted non-mydriatic Fundus imaging for detection of Diabetic Retinopathy in Colombia
(2022)
Diabetic retinopathy (DR) is a well-recognized complication of diabetes mellitus where retinal function is compromised. It is considered a public health disease and is the fifth leading cause of visual impairment worldwide. But although the worldwide prevalence is continually increasing, little is known about the frequency of this disease in Colombia, South America. On the other hand, telemedicine is presented as a tool that has the potential to improve access to health care services, for remote or rural populations, and for those who have limited access due to physical or other disabilities. Recent technological advances in telecommunication and digital imaging, including fundus photography, telemedicine represents a valuable clinical aid for the documentation and diagnosis of ocular pathologies, and therefore helps to minimize adverse outcomes associated with chronic disease such as diabetes mellitus.
Das trockene Auge ist eine komplexe Erkrankung des vorderen Augenabschnitts. Es gibt eine Vielzahl von Ursachen, sowie eine Vielzahl an Therapiemöglichkeiten. Diese Arbeit befasst sich mit Benetzungsmitteln als Therapieform. Es existieren verschiedene Benetzungsmittel, die sowohl von Augenärzten, als auch von Optometristen und Optikern verabreicht werden. Es wird eine Übersicht über alle Benetzungsmittel erstellt, die in der Schweiz von Optometristen verabreicht werden können und ein Schema zur Anwendung je nach Diagnose entwickelt.
Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann.
Red Teaming
(2019)
Zu Beginn der Arbeit wurden die theoretischen Grundlagen zu Penetrationstest, Audit und Red Teaming beschrieben. In den rechtlichen Rahmenbedingungen wurden betroffene Gesetze unter die Lupe genommen.
Anschließend wurde eine Marktforschung bestehend aus einer Primär- und einer Sekundärmarkforschung durchgeführt. Die Sekundärforschung beschreibt die Angebote und Dienstleister, die auf dem Markt Red Teaming anbieten. Daraus wurden Unternehmen aus dem DACH-Raum für die Interviews der Primärforschung ausgewählt.
Das Red Team muss ein vorher definiertes Ziel erreichen. Das Red Team führt in Abstimmung mit dem White Team Angriffe durch, die technische, physische und menschliche Komponenten betreffen können. Welche Komponenten verwendet werden, unterscheidet sich nach Projekt und Dienstleister. Das Blue Team hat die Aufgabe, die Angriffe zu erkennen und darauf zu reagieren.
Mit dem gesammelten theoretischen Wissen und den Interviews wurden die Methoden verglichen und eine Methodik zur Einordnung erstellt. Das Red Teaming, Penetrationstests und Audits sind für unterschiedliche Situationen nützlich. Um die Auswahl zu erleichtern, ist es sinnvoll, die Ziele zu definieren, die mit dem Test erreicht werden sollen.
Als dritter Indikator ist der Scope hilfreich, da ein Penetrationstest eine technische Prüfung darstellt und beim Audit oder Red Teaming oftmals eine ganzheitliche Betrachtung der Organisation erfolgt.
Im letzten Abschnitt wird eine praktikable Methode zur Durchführung von Red Teaming beschrieben. Hierzu wurden Thesen auf Grundlage des gesammelten Wissens aufgestellt.
Die Arbeit endet mit einem Fazit und den Zukunftsaussichten von Red Teaming.
Ziele: Mithilfe des in dieser Arbeit entwickelten Konzeptes soll die Sehleistung noch einfacher ermittelt werden. Hierfür soll das plusoptiX Binokular Autorefraktometer so weit verändert werden, dass es zusätzlich zum Ermitteln der Sehleistung genutzt werden kann. Methodik: Es wurden 212 Probanden im Alter von drei bis fünfzehn Jahren untersucht. Die Sehleistung wurde zum einen anhand der LEA Symbole ermittelt und zum anderen mithilfe des in dieser Arbeit entwickelten Konzeptes. Ergebnisse: In wenigen Fällen kam es zu einer Abweichung von einer Visusstufe. Hierbei lässt sich keine Tendenz feststellen mit welchem Verfahren die Probanden größere Schwierigkeiten hatten. Die Standardabweichung liegt bei den Probanden ohne Korrektur bei 0,35. Die Probanden mit Korrektur haben eine Standardabweichung von 0,44. Der durchschnittliche Nahvisus liegt bei 0,8. Zusammenfassung: Es lässt sich sagen, dass die Ermittlung der Sehleistung anhand dieses Konzeptes sehr gut durchführbar ist. Der Ablauf und die Eingabemaske lassen sich im weiteren Verlauf noch verbessern. Des Weiteren kann dieses Konzept langfristig für weitere Bereiche wie Myopie Management und Visual Training weiterentwickelt werden.
Ziele: Ein Handbuch zum umweltbewussten und nachhaltigen Wirken im Augenoptikfachgeschäft. Es zeigt, wie idealerweise gewirtschaftet wird unter Berücksichtigung ökonomischer, ökologischer und sozialer Aspekte.
Methodik: Diese Studie ist ein Wissenstank aus vielen verschiedenen Aspekten zu Umweltschutz und Nachhaltigkeit, die durch Literaturrecherche aufgebaut wurde. Die Informationen sind für den Nutzen im augenoptischen Betrieb ausgelegt.
Ergebnisse: Die Studie zeigt auf, wie viele Möglichkeiten es gibt und notwendig sind, um umweltverträglich zu wirtschaften und bringt ein Handbuch hervor für den Augenoptik-Betrieb. Verantwortungsbewusstes, nachhaltiges Handeln entsteht durch Kennen und Verstehen der Zusammenhänge mit anschliessender Umsetzung.
Es kann gezeigt werden, dass nachhaltiges Denken und Arbeiten in jedem Bereich angewendet werden kann und dabei sowohl die Umwelt als auch das Unternehmen unterstützt.
Zusammenfassung: Das entstehende Handbuch ist ein Leitwerk für Augenoptik-Betriebe. Durch die Umsetzung nachhaltigen Wirtschaftens mit einer möglichst optimierten Kreislaufwirtschaft ist nicht nur der Umwelt und den Menschen gedient, sondern auch der Fortbestand des Unternehmens, die Wettbewerbsfähigkeit und das positive Betriebsergebnis werden gefördert und gesichert.