Purpose
The purpose of this study was to investigate the correlation of measured visual acuity
(VA) both static and dynamic obtained with static and dynamic measuring tests, as well
as, response time to visual stimulus and analysis of its influence on dynamic visual
acuity. The aim was to compare the results gathered for the three age groups and
analyze the possible differences.
Methods
The test groups consisted of 75 subjects between 10 and 60 years old, categorized in
three age groups. The measurements of static and dynamic visual acuity and reaction
time were conducted. The set of nine tests (five with radial magnification speed and four
simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure
dynamic visual acuity and the set of two tests for reaction time measurement.
Results
Compared to static visual acuity in both tests, the results obtained with measurements
of dynamic visual acuity resulted in lower values depending on Landolt ring size and
magnification speed of animation. In average, the dynamic visual acuities in tests with
different magnification speeds were lower than static by 0.4 visual acuity units, or 31%
and the average of dynamic visual acuity after subtracting motoric component (reaction
time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating
driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while
at 130 km/h average drop for younger and middle age groups was 37% and for older
group was 44% and after subtracting motor component values for 72 km/h speed
simulation average drop in visual acuity values was 23% for all three groups; for 130
km/h speed simulation younger and middle aged group average drop of visual acuity
was 20% and with older group it was 24%.
Conclusion
The tests used in this study were simple and fast and revealed significant difference
between static and dynamic visual acuity and influence of reaction time on dynamic
Nataša Vujko Muždalo Abstract
2
visual acuity values. It is hoped that this thesis will be a positive contribution in testing
and training of dynamic visual and sensory response skill with drivers, sportsmen and
people with visual-motor dysfunction.
Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT),
motoric component, dynamic visual acuity test, reaction time test, radial increase in size
In der Arbeit wurde eine GC-MS-Methode zur Quantifizierung von 21 identifizierten Aromastoffen, die aus getoasteten Eichenholzchips in Wein übergehen, entwickelt. Diese Methode wurde für die ausgewählten Substanzen unter Einbeziehung der Festphasenextraktion mittels des internen Standard 2-Octanol kalibriert. Die Analyte zeigten mit Ausnahme von Syringaaldehyd lineares Verhalten bei Korrelationen von 0,986 bis 0,999. Die Nachweisgrenzen, die über das Signal-zu-Rausch-Verhältnis ermittelt wurden, lagen im Bereich von 0,03 bis 0,47 µg/l. Der Test auf Wiederholbarkeit ergab mit Werten von kleiner 10% für die meisten untersuchten Stoffe in Rot- und Weißwein zufrieden stellende Werte. Mit der entwickelten Methode wurden Barriqueweine des Handels und selbst hergestellte Chipsweine untersucht. Bei der Untersuchung der Chipsweine, die nach einem vollen Versuchsplan hergestellt wurden, zeigten sich signifikante Einflüsse durch die Faktoren Kontaktzeit, Toastung und Größe sowie durch die Wechselwirkung Toastung-Größe auf die Konzentrationen der meisten identifizierten Substanzen. Bei der Betrachtung der Konzentrationen der ausgewählten Substanzen in Barriqueweinen zeigten sich signifikante Unterschiede zu den entsprechenden Konzentrationen in den hergestellten Chipsweinen. Diese signifikanten Unterschiede wurden mittels Hauptkomponentenanalyse und anschließender Klassifizierung über die SIMCA-Methode dazu genutzt, um die önolgischen Verfahren Chipsbehandlung und Barriquefasslagerung zu differenzieren.