Open Access
Refine
Document Type
- Master's Thesis (14) (remove)
Is part of the Bibliography
- no (14)
Keywords
- Myopia (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- limbal sclera contour (2)
- vorderer Augenabschnitt (2)
- Abschlussarbeit (1)
- Augenoptik-Branche (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- Defocus (1)
- Diffusion (1)
- Edge Detection (1)
- Erblindung (1)
- Eye tracking (1)
- Fixation (1)
- Kantendetektion (1)
- Kreislaufwirtschaft (1)
- Masterarbeit AO (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Nachhaltigkeit (1)
- Scanpath (1)
- Screening (1)
- Versorgungskapazität (1)
- Visual search (1)
- blindness (1)
- care capacity (1)
- customized (1)
- myopia management (1)
- optometric and optical companies (1)
- peripheral myopic defocus (1)
- soft multifocal contact lens (1)
- sustainability (1)
Institute
- Optik und Mechatronik (14) (remove)
Purpose: Recent studies found a reduction of myopia progression with multifocal contact lenses, however, with yet unclear mechanism. This raises the hypothesis that the addition zones of the multifocal contact lenses induce myopic defocus on the retina, which consequentially leads to choroidal thickening and therefore inhibited eye growth. We tested the effect of the optical design of multifocal contact lenses on choroidal thickness.
Methods: 18 myopic students wore four different contact lenses ((1) single-vision lens corrected for distance, (2) single-vision lens with +2.50 D full-field defocus, (3) “Multifocal center-distance” design, addition +2.50 D, (4) “Multifocal center-near” design, addition +2.50 D) for each 30 minutes on their right eye. Automated analysis of the macular choroidal thickness, vitreous chamber depth and eccentric photorefraction were performed before and after each contact lens.
Results: Choroidal thickness and vitreous chamber depth showed no significant differences to baseline with none of the contact lenses. Choroidal thickness increased the most with the “Multifocal center-distance” and the full-field defocus lens, followed by the “Multifocal center-near” and the single-vision contact lens (+2.1 ± 11.1 μm, +2.0 ± 11.1 μm, +1.6 ± 11.3 μm, +0.9 ± 11.2 μm, respectively). The “Multifocal center-distance” design showed an overall more myopic refractive profile than the other lenses. Changes of vitreous chamber depth occurred in anti-phase to these of choroidal thickness.
Conclusion: Multifocal contact lenses have no significant influence on choroidal thickness and after short-term wear. Therefore, it is assumed that it is not the main contributor to the protective effect of multifocal contact lenses in myopia control.
Das trockene Auge ist eine komplexe Erkrankung des vorderen Augenabschnitts. Es gibt eine Vielzahl von Ursachen, sowie eine Vielzahl an Therapiemöglichkeiten. Diese Arbeit befasst sich mit Benetzungsmitteln als Therapieform. Es existieren verschiedene Benetzungsmittel, die sowohl von Augenärzten, als auch von Optometristen und Optikern verabreicht werden. Es wird eine Übersicht über alle Benetzungsmittel erstellt, die in der Schweiz von Optometristen verabreicht werden können und ein Schema zur Anwendung je nach Diagnose entwickelt.
Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann.
Eine detaillierte Auswertung des Corneo-Skleral-Profils ist für die Anpassung von weichen Kontaktlinsen und Sklerallinsen von besonderer Relevanz. Das Ziel dieser Studie ist es, das Profil der limbalen Sklera anhand des Zusatzmoduls CSP-Report der OCULUS Pentacam® zu beschreiben. Hierbei soll überprüft werden, ob der CSP-Report Ergebnisse bisheriger Studien bestätigt und somit zukünftig zur Simulation von Sklerallinsen verwendet werden kann.
Ziele: Ein Handbuch zum umweltbewussten und nachhaltigen Wirken im Augenoptikfachgeschäft. Es zeigt, wie idealerweise gewirtschaftet wird unter Berücksichtigung ökonomischer, ökologischer und sozialer Aspekte.
Methodik: Diese Studie ist ein Wissenstank aus vielen verschiedenen Aspekten zu Umweltschutz und Nachhaltigkeit, die durch Literaturrecherche aufgebaut wurde. Die Informationen sind für den Nutzen im augenoptischen Betrieb ausgelegt.
Ergebnisse: Die Studie zeigt auf, wie viele Möglichkeiten es gibt und notwendig sind, um umweltverträglich zu wirtschaften und bringt ein Handbuch hervor für den Augenoptik-Betrieb. Verantwortungsbewusstes, nachhaltiges Handeln entsteht durch Kennen und Verstehen der Zusammenhänge mit anschliessender Umsetzung.
Es kann gezeigt werden, dass nachhaltiges Denken und Arbeiten in jedem Bereich angewendet werden kann und dabei sowohl die Umwelt als auch das Unternehmen unterstützt.
Zusammenfassung: Das entstehende Handbuch ist ein Leitwerk für Augenoptik-Betriebe. Durch die Umsetzung nachhaltigen Wirtschaftens mit einer möglichst optimierten Kreislaufwirtschaft ist nicht nur der Umwelt und den Menschen gedient, sondern auch der Fortbestand des Unternehmens, die Wettbewerbsfähigkeit und das positive Betriebsergebnis werden gefördert und gesichert.
Purpose: The aim is to be able to advise patients on the choice of sports and exercises regarding the effects on the intraocular pressure.
Methods: The search engines Google Scholar and PubMed were used to search for suitable studies. The studies were summarized, and the most important data were collected in one table for each study. The effect on the IOP was extracted or, if not given in the article, calculated by the difference of means of the IOP after or during exercise, and the baseline IOP before, whenever these values were available.
Findings: A total of 47 studies out of the years 1990 to 2020 that investigated the influence on the IOP of the most popular sports actively practiced in Germany were reviewed and summarized: twelve for running, sixteen for fitness/ weight training, one for swimming/diving, twelve for cycling, four for hiking, and two for yoga.
Conclusions: Throughout all studies and sports it was seen that physical fitness stabilized the IOP. Higher
intensity of exercise led to higher fluctuations of the IOP. Moderate endurance training keeps the IOP fluctuations low and may lead to a lower baseline IOP if practiced on a regular base. Fitness and weight training lead to fluctuations of the IOP in a pronounced manner when performed at moderate and high intensity. Therefore, only a moderate training can be recommended if there is need to keep the IOP stable. Isometric exercise is not recommended as it provokes a rise of the IOP even when performed with light loads. The Valsalva Maneuver should always be avoided as it leads to additional fluctuations of the IOP. Also, the IOP behaved more stable during resistance training when higher fitness was present.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.
Novel myopia control spectacle lenses induce peripheral contrast reduction via optical diffusion. It is suggested, that the contrast reduction alters retinal processes in the low-level neural circuity, leading to an inhibition of eye growth. The purpose of this thesis is to evaluate the influence of full-field contrast reduction on low-level neural processing of the retina, described by the edge contrast sensitivity.
Demographische Veränderungen durch eine zunehmende Alterung der Gesellschaft und eine Zunahme an Erkrankungen wie der AMD, des Glaukoms und der diabetischen Retinopathie stellen ophthalmologische Versorgungs- und Vorsorgemaßnahmen in Deutschland vor immer größere Herausforderungen. Einen wesentlichen Beitrag zur Sicherung der Vorsorgemaßnahmen können in der Zukunft Optometristen leisten. Mit Hilfe modernster Technologien, wie dem Ultra-Widefield-cSLO (Optos Daytona, können auch bei kleinen Pupillendurchmessern 200° Aufnahmen vom Augenhintergrund erstellt werden.
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.