Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (69)
- Article (28)
- Conference Proceeding (17)
- Master's Thesis (14)
- Report (3)
Keywords
- Abschlussarbeit (6)
- Bachelorarbeit A/H (4)
- Augenoptik (3)
- FrACT (2)
- Hörgerät (2)
- Landoltring (2)
- Leitfaden (2)
- Myopia (2)
- Myopieprogression (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- Studie (2)
- Studium (2)
- Visus (2)
- limbal sclera contour (2)
- vorderer Augenabschnitt (2)
- 3D-Druck (1)
- 3D-Refraktion (1)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Aalener Schnell Satztest (1)
- Ablaufplan (1)
- Absolventen (1)
- Absolventenbefragung (1)
- Atropin (1)
- Augenlänge (1)
- Augenoptik-Branche (1)
- Augenoptikgeschäft (1)
- Ausbildung (1)
- Bachelorarbeit A (1)
- Befragung (1)
- Brillenfassung, UV-Durchlässigkeit (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- Deflektometrie (1)
- Defocus (1)
- Dienstleistungsangebot (1)
- Diffusion (1)
- Digitalisierung (1)
- ETDRS (1)
- ETDRS-Tafeln (1)
- Edge Detection (1)
- Erblindung (1)
- Ethik (1)
- Eye tracking (1)
- Fixation (1)
- Geschäftsmodell (1)
- Gleitsichtbrille (1)
- Gleitsichtgläser (1)
- Grenzfrequenz (1)
- High-End-Hörsystem (1)
- Hörgerätverifikation (1)
- Hörqualität (1)
- Hörsystem (1)
- Hörsysteme (1)
- IOL Master 500 (1)
- Inter-Test Reliabilität (1)
- KI (1)
- Kameramessung (1)
- Kampimetrie (1)
- Kantendetektion (1)
- Kind (1)
- Kinder (1)
- Kommunikationstraining (1)
- Kontaktlinse (1)
- Kontaktlinsen (1)
- Kontaktlinsen-Service-System (1)
- Kontaktlinsensprechstunde (1)
- Kostenakzeptanz (1)
- Kreislaufwirtschaft (1)
- Kreuzzylinder (1)
- Kundengruppen (1)
- Lehrmethoden (1)
- Lernsoftware (1)
- Lernvideo, Verkaufsgespräch (1)
- Lernvideo, e-Learning, Leitfaden (1)
- Leuchtdichte Homogenität (1)
- Leuchtdichte, Radiospektrometer, Kalibrierung, Spiegelreflexkamera (1)
- Leuchtdichteverteilung (1)
- Lions Club (1)
- Low-End-Hörsystem (1)
- Marokko (1)
- Masterarbeit AO (1)
- Materialeigenschaften (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Messmethode (1)
- Messsystem (1)
- Messtechnik (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Myopiekontrolle (1)
- Myopiemanagement (1)
- Nachhaltigkeit (1)
- Ohrmodell (1)
- Omnichannel (1)
- Onlineportal (1)
- Optometrist (1)
- Optotypen (1)
- Orthokeratologie (1)
- Perimetrie (1)
- Primary Eye Care Provider (1)
- Psychophysik (1)
- RCS (1)
- Refraktionsbestimmung (1)
- Retest-Reliabilität (1)
- Risikoanalyse (1)
- SNR-Verhältnis (1)
- Satztest (1)
- Scanpath (1)
- Schule (1)
- Screening (1)
- Sehilfen (1)
- Sehschärfe (1)
- Six Sigma (1)
- Sphärisches Äquivalent (1)
- Sri Lanka (1)
- Strategie, Unternehmensführung, AMVO, VaKE (1)
- Streifenprojektion (1)
- Streifenprojektionsgerät (1)
- Studiengang Augenoptik (1)
- Störgeräusch (1)
- Technikfolgenabschätzung (1)
- Tieftonkompression (1)
- Tolerance of blur, PAL`s, Astigmatism, Blurtest, Pretest (1)
- Umfrage (1)
- Unschärfetoleranz , Gleitsichtgläser, Astigmatismus , Blurtest, Pretest (1)
- Unverträglichkeit (1)
- Unzufriedenheit (1)
- Versorgungskapazität (1)
- Visual search (1)
- Vorderkammertiefe (1)
- Weblog (1)
- Webportal (1)
- Webseite (1)
- Zufriedenheitsmessung (1)
- Zyklofusionstest (1)
- albinism (1)
- artificial consciousness (1)
- augenoptischer Betrieb (1)
- automatical telephone audiometry, hearing aid fitting (1)
- automatisierter Telefonhörtest, Hörgeräteanpassung (1)
- berufliche Perspektiven (1)
- blindness (1)
- care capacity (1)
- customized (1)
- erfolgreiches Geschäftsmodell, optometrische Dienstleistungen, Wettbewerb (1)
- genes (1)
- i.Profiler (1)
- internationale Schwerhörigenhilfe (1)
- learning videos, e-learning, guideline (1)
- low vision (1)
- luminance distribution (1)
- luminance homogeneity (1)
- luminance, radio spectrometer, calibration, reflex-camera (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- monokulare Refraktionsbestimmung (1)
- myopia management (1)
- optometric and optical companies (1)
- optometrische Dienstleistungen (1)
- peripheral myopic defocus (1)
- proaktive Ansprache (1)
- psychophysics (1)
- repeatability (1)
- soft multifocal contact lens (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- strategy, management, AMVO, VaKE (1)
- successful business-model, optometrical service, competition (1)
- sustainability (1)
- two-rod test (1)
- vision therapy (1)
- visual acuity (1)
Institute
- Optik und Mechatronik (131) (remove)
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.
Deflektometrie
(2015)
In der vorliegenden Bachelorarbeit wurde ein, im Zentrum für Optische Technologien neuartiger Aufbau, eingemessen, sowie eine Anleitung für diesen erstellt. Dieser Messaufbau basiert auf Deflektometrie. Es werden Messungen mit diesem Gerät durchgeführt. Für Vergleichsmessungen wir ein Interferometer (ALI 201) verwendet.
Es wird der aktuelle Stand der Technik in der Interferometrie und der Deflekto-metrie erklärt. Hierbei wird auch auf die allgemeine Funktionsweise beider Messtechniken eingegangen.
Anschließend werden die bei den Versuchsmessungen verwendeten Geräte allgemein erläutert. Das heißt der Aufbau und die Funktion eines Fizeau-Interferometers und eines Phase-Measuring-Deflektometers.
Außerdem wurde eine Bedienungsanleitung für das Deflektometer mit einem LED-Tunnel erstellt, welches ein Entwicklungsgerät von Zeiss ist. Schließlich werden Flächen mit verschiedenen Oberflächenstrukturen mit den Messgeräten ausgemessen. Die Messwerte mit dem Interferometer sollen als Vergleichswerte dienen, damit man die Messungen am Deflektometer bewerten und einschätzen kann. Es geht vor allem darum, zu sehen, welche Oberflächen mit dem Deflektometer produktiv vermessen werden können. Außerdem soll bei geeigneten Oberflächen die Wiederholbarkeit des Geräts anhand von 20 Wiederholungsmessungen getestet werden.
Ziel dieser Arbeit ist es, das Zielgruppenmodell Roper Consumer Styles (RCS)
der Gesellschaft für Konsumforschung (GfK) genau zu beschreiben und dessen
Anwendbarkeit auf die Augenoptik zu prüfen.
Zu Beginn werden die Geschichte und Entwicklung der Roper Consumer Styles
(RCS) sowie das Modell selbst und seine einzelnen Lebensstile erläutert. Im
zweiten Teil setzt sich diese Arbeit mit der Anwendung der Roper Consumer
Styles (RCS) in der Augenoptik auseinander. Es wird ein Pilotprojekt vom
Zentralverband der Augenoptiker (ZVA) und der Gesellschaft für Konsumforschung
(GfK) vorgestellt. Die Gesellschaft für Konsumforschung (GfK) bestimmt
das Einzugsgebiet des Optikers, analysiert die Kundschaft in dem Gebiet und
zeigt auf, bei welchen Zielgruppen noch Potenzial besteht. Der Optiker bekommt
von der Gesellschaft für Konsumforschung (GfK) konkrete Empfehlungen,
welche Marken und welche Designs die gewünschten Zielgruppen ansprechen.
Es ergeben sich vier Bereiche, in denen die Roper Consumer Styles (RCS) in
der Augenoptik angewandt werden können: Produkt/Sortimentspolitik, Preispolitik,
Kommunikationspolitik und Ladenbau/Schaufenstergestaltung. Anschließend
wird das Projekt einer kritischen Würdigung unterzogen. Dabei werden zwei
Verbesserungsvorschläge vorgebracht. Ein Vorschlag ist, die Fassungen nicht
nach Marken, sondern nach den Styles zu unterscheiden und eine Klassifizierung
der Fassungen nach den Roper Consumer Styles (RCS) zu machen. Der
andere Vorschlag ist, ein Kurzfragebogen zu entwickeln, der eine direkte
Einordnung des einzelnen Kunden nach den Roper Consumer Styles (RCS)
ermöglicht. Abschließend wurde eine Umfrage unter den Betrieben, die am
Projekt teilgenommen haben, durchgeführt. Die Ergebnisse der Umfrage zeigen,
dass das Zielgruppenmodell Roper Consumer Styles (RCS) in der Augenoptik
Anwendung findet und von den Optikern selbst auch als positiv bewertet wird.
Aus diesem Grund soll die Analyse der Gesellschaft für Konsumforschung (GfK)
in Zukunft für einen größeren Kreis von Betrieben angeboten werden.
Pharmaceutical agents or drugs often have a pronounced impact on protein-protein interactions in cells, and in particular, cell membranes. Changes of molecular conformations as well as of intermolecular interactions may affect dipole-dipole interaction between chromophoric groups, which can be proven by measuring the Förster resonance energy transfer (FRET). If these chromophores are located within or in close proximity to the plasma membrane, they are excited preferentially by an evanescent electromagnetic wave upon total internal reflection (TIR) of an incident laser beam. For the TIR-FRET screening of larger cell collectives, we performed three separate steps: (1) setting up of a membrane associated test system for probing the interaction between the epidermal growth factor receptor (EGFR) and the growth factor receptor-bound protein 2; (2) use of the Epac-SH188 sensor for quantitative evaluation under the microscope; and (3) application of a TIR fluorescence reader to probe the interaction of GFP with Nile Red. In the first two steps, we measured FRET from cyan (CFP) to yellow fluorescent protein (YFP) by spectral analysis and fluorescence lifetime imaging (FLIM) upon illumination of whole cells (epi-illumination) as well as selective illumination of their plasma membranes by TIR. In particular, TIR excitation permitted FRET measurements with high sensitivity and low background. The Epac sensor showed a more rapid response to pharmaceutical agents, e.g., Forskolin or the A2B adenosine receptor agonist NECA, in close proximity to the plasma membrane compared to the cytosol. Finally, FRET from a membrane associated GFP to Nile Red was used to test a multi-well TIR fluorescence reader with simultaneous detection of a larger number of samples.