Open Access
Refine
Year of publication
Document Type
- Article (156)
- Bachelor Thesis (146)
- Conference Proceeding (104)
- Report (31)
- Master's Thesis (22)
- Doctoral Thesis (11)
- Other (3)
- Patent (1)
Keywords
- Augenoptik (12)
- virtual reality (9)
- Abschlussarbeit (7)
- Augenoptiker (7)
- Studie (6)
- Hörgerät (5)
- Bachelorarbeit A/H (4)
- Business Process Management Systems (4)
- Fuzzy Logic (4)
- Kontaktlinse (4)
Institute
- Optik und Mechatronik (131)
- Wirtschaftswissenschaften (122)
- Maschinenbau und Werkstofftechnik (81)
- Augenoptik und Hörakustik (43)
- Elektronik und Informatik (42)
- Internationale Betriebswirtschaft (18)
- Chemie (12)
- Maschinenbau/Fertigungstechnik (2)
- Informatik (1)
- Mechatronik (1)
Ziel dieser Arbeit ist es, die herstellerspezifische Umsetzung der präskriptiven Formeln NAL-NL2 und DSL v5.0 bezogen auf die MPO an drei ausgewählten Geräten in zwei simulierten Patientenfällen einer cochleären Schwerhörigkeit zu vergleichen. Die maximale Schalldruckpegelleistung für tone burst Signale werden über die Messboxmessung am Kuppler und am Kemar im Freifeld für das Antaro Mini mit Tragehaken von Hansaton Akustik, das Bolero Q90 von Phonak und dem Alta Mini HDO 85 von Oticon untersucht. Die Messwerte der Kupplermessung zeigen keine eindeutige Normalverteilung und signifikante Unterschiede innerhalb der Formel mit dem spezifischen Hörverlust zwischen den Hörgeräten. Mit dem Ziel die Restdynamik des Hörgeschädigten mit Hörgeräten maximal aus-zunutzen, stellt das Bolero für NAL-NL2 und DSL v5.0, für beide Hörverluste die meiste Dynamik bereit. Für DSL v5.0 ist die Abweichung der MPO geringer bezogen auf die Unbehaglichkeitsschwelle als NAL-NL2. Für NAL-NL2 zeigt des Antaro die geringsten Unterschiede von -11,5 dB bis 0,5 dB bei 500 Hz und 3 kHz zur 80 Isophone für den Hochtonsteilabfall, Das Bolero und Alta überschreiten sie bis zu 31,5 dB bei 3 kHz. Die DSL Zielwerte werden mit einer gemittelten Abweichung des Bolero von -0,96 dB für den Hochtonsteilabfall und -0,13 dB für den Hochtonschrägabfall vor dem Antaro mit -1,37 dB / -2,94 dB und dem Alta mit -6,31 dB /-3,30 dB unterschritten. Alle diese Ergebnisse zeigen, dass die Hersteller die präskriptiven Formeln abgeändert haben und weitere Erkenntnisse hinzugefügt haben. NAL-NL2 und DSL v5.0 sind Hörgeräte unabhängige Formeln, d.h. unter optimalen Bedingungen sollten die Hörgeräte gleiche MPO Begrenzungen für die gleiche Formel und Hörverlust aufzeigen. Diese Hypothese wird nicht bestätigt.
In Zeiten des disruptiven Wandels in der Augenoptik-Branche droht eigenständigen Optikern/Optometristen Gefahr, essenzielle Kundenanteile an Online-Händler zu verlieren. Daher werden zukünftig höhere Anforderungen des Marktes an Optiker/Optometristen gestellt, welche als erste Anlaufstelle der Bevölkerung gelten und umfangreiche optometrische Dienstleistungen rund um das visuelle System anbieten sollten. Folglich treten qualitativ hochwertige Weiterbildungen vermehrt in den Vordergrund, um eine exzellente Versorgung des Kunden zu gewährleisten und Wettbewerbsvorteile zu erzielen. Aufgrund der unterschiedlichen Weiterbildungs-möglichkeiten in Deutschland, gestaltet es sich für einen Studiengang als Hürde, sich von der Konkurrenz abzuheben. Daher erweist sich ein ausführlich herausgearbeitetes Marketingkonzept als Schlüssel zum Erfolg. Die vorliegende Bachelorthesis beschäftigt sich, auf Basis von Erkenntnissen quantitativer Studierendenbefragungen, mit der Gestaltung eines Marketing-konzepts für den berufsbegleitenden Masterstudiengang M. Sc. Vision Science and Business (Optometry) der Hochschule Aalen. Im Rahmen der Bachelorthesis werden theoretische Grundlagen zu wichtigen Begriffen aus dem Marketing erläutert, sowie gezielt mit Marketingstrategien und Umsetzungsvorschlägen für den berufsbegleitenden Master kombiniert.
In dieser Bachelorarbeit geht es darum, ein System zu bauen, mit dem die Augenbewegungen gemessen werden können bei Verwendung von GS und im Vergleich dazu bei Verwendung von Einstärkengläsern (ES). Das System soll eine natürliche Lesesituation simulieren. Es sollen die Grenzen herausgefunden werden, wo der astigmatische Fehler beim Tragen von GS gerade noch akzeptiert wird. Hierfür soll keine Augentrackingbrille verwendet werden, sondern aufgrund der Kopfbewegungen (KB) und dem Wissen wo der Proband hinschaut, die Augenbewegungen (AB) berechnet werden.
Purpose
The purpose of this study was to investigate the correlation of measured visual acuity
(VA) both static and dynamic obtained with static and dynamic measuring tests, as well
as, response time to visual stimulus and analysis of its influence on dynamic visual
acuity. The aim was to compare the results gathered for the three age groups and
analyze the possible differences.
Methods
The test groups consisted of 75 subjects between 10 and 60 years old, categorized in
three age groups. The measurements of static and dynamic visual acuity and reaction
time were conducted. The set of nine tests (five with radial magnification speed and four
simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure
dynamic visual acuity and the set of two tests for reaction time measurement.
Results
Compared to static visual acuity in both tests, the results obtained with measurements
of dynamic visual acuity resulted in lower values depending on Landolt ring size and
magnification speed of animation. In average, the dynamic visual acuities in tests with
different magnification speeds were lower than static by 0.4 visual acuity units, or 31%
and the average of dynamic visual acuity after subtracting motoric component (reaction
time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating
driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while
at 130 km/h average drop for younger and middle age groups was 37% and for older
group was 44% and after subtracting motor component values for 72 km/h speed
simulation average drop in visual acuity values was 23% for all three groups; for 130
km/h speed simulation younger and middle aged group average drop of visual acuity
was 20% and with older group it was 24%.
Conclusion
The tests used in this study were simple and fast and revealed significant difference
between static and dynamic visual acuity and influence of reaction time on dynamic
Nataša Vujko Muždalo Abstract
2
visual acuity values. It is hoped that this thesis will be a positive contribution in testing
and training of dynamic visual and sensory response skill with drivers, sportsmen and
people with visual-motor dysfunction.
Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT),
motoric component, dynamic visual acuity test, reaction time test, radial increase in size
Im Rahmen dieser Bachelorarbeit MATLAB in Augenoptik und Höorakustik wird eine Plattform entwickelt, die die Studierenden im Studiengang Augenoptik/Augenoptik und Hörakustik an der Hochschule Aalen dabei unterstützt, sich mathematische Inhalte selbst zu erarbeiten und den Umgang mit MATLAB zu erlernen. Mithilfe von MATLAB wird die Anwendung mathematischer Grundlagen auf augenoptische und hörakustische Inhalte praxisorientiert umsetzt. Um dies erreichen zu können, werden die notwendigen Vorüberlegungen angestellt. Hier wird zunächst auf den Begriff des e-Learning eingegangen, anschließend wird in einem Vergleich festgestellt, dass andere Hochschulen mit fachlich ähnlichen Bachelor-Studiengängen der Augenoptik/Optometrie in Deutschland MATLAB bisher nicht in ihre Lehre integriert haben. Fachverwandte Bachelor-Studiengänge wie solche der Feinwerktechnik oder Optoelektronik/ Lasertechnik hingegen lehren durchgängig MATLAB oder andere fachlich relevante Programmiersprachen. Zudem wird mithilfe einer Befragung der Studierenden im Studiengang Augenoptik/Augenoptik und Hörakustik an der Hochschule Aalen festgestellt, dass ein grundsätzliches Interesse der Studierenden an der Thematik MATLAB vorliegt. Nun werden die Skripte, die den Studierenden zur selbstständigen Erarbeitung der Themen"Lineare Gleichungssysteme und Matrizen" sowie "Mehrdimensionale Integration" zur Verfügung gestellt werden, vorgestellt. Anschließend wird dargestellt, in welcher Form die Integration der Lehre von MATLAB in die Lehrveranstaltung Methoden der Mathematik Augenoptik und Hörakustik vonstatten gehen kann und welche Möglichkeiten hinsichtlich der Umsetzung dessen bestehen. Es wird veranschaulicht, wie MATLAB zur praxisorientierten Unterstützung der Lehre in anderen Lehrveranstaltungen genutzt werden kann. Beispielhaft werden hierbei zwei Programme gezeigt, die sich mit der Berechnung eines FIR-Filters und der Beugung an der Kreisblende befassen. Damit findet die Anwendung von MATLAB auf augenoptische und hörakustische Sachverhalte statt. Schließlich wird erläutert, wie die in dieser Arbeit konzipierte e-Learning-Plattform bei Bedarf zukünftig erweitert werden kann.
Future lunar exploration will be based on in-situ resource utilization (ISRU) techniques. The most abundant raw material on the Moon is lunar regolith, which, however, is very scarce on Earth, making the study of simulants a necessity. The objective of this study is to characterize and investigate the sintering behavior of EAC-1A lunar regolith simulant. The characterization of the simulant included the determination of the phase assemblage, characteristic temperatures determination and water content analysis. The results are discussed in the context of sintering experiments of EAC-1A simulant, which showed that the material can be sintered to a relative density close to 90%, but only within a very narrow range of temperatures (20–30 °C). Sintering experiments were performed for sieved and unsieved, as well as for dried and non-dried specimens of EAC-1A. In addition, an analysis of the densification and mechanical properties of the sintered specimens was done. The sintering experiments at different temperatures showed that the finest fraction of sieved simulant can reach a higher maximum sintering temperature, and consequently a higher densification and biaxial strength. The non-dried powder exhibited higher densification and biaxial strength after sintering compared to the dried specimen. This difference was explained with a higher green density of the non-dried powder during pressing, rather than due to an actual influence on the sintering mechanism. Nevertheless, drying the powder prior to sintering is important to avoid the overestimation of the strength of specimens to be fabricated on the Moon.