Open Access
Refine
Year of publication
Document Type
- Article (156)
- Bachelor Thesis (146)
- Conference Proceeding (104)
- Report (31)
- Master's Thesis (22)
- Doctoral Thesis (11)
- Other (3)
- Patent (1)
Keywords
- Augenoptik (12)
- virtual reality (9)
- Abschlussarbeit (7)
- Augenoptiker (7)
- Studie (6)
- Hörgerät (5)
- Bachelorarbeit A/H (4)
- Business Process Management Systems (4)
- Fuzzy Logic (4)
- Kontaktlinse (4)
- visualization (4)
- Kontaktlinsen (3)
- Myopia (3)
- Verbraucherzufriedenheit (3)
- Assignment Automation (2)
- Augmented Reality (2)
- Business Process Modeling Notation (2)
- Digitalisierung (2)
- FrACT (2)
- Git (2)
- Landoltring (2)
- Leitfaden (2)
- Marketing (2)
- Myopieprogression (2)
- Nachhaltigkeit (2)
- Optometrie (2)
- Optometrist (2)
- Orthokeratologie (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- Schwerhörigkeit (2)
- Sehschärfe (2)
- Sehtest (2)
- Studium (2)
- Systems Modeling Language (SysML) (2)
- Umfrage (2)
- Visus (2)
- artificial neural networks (2)
- limbal sclera contour (2)
- machine learning (2)
- software configuration management (2)
- software design pattern detection (2)
- software engineering (2)
- systems engineering (2)
- systems modeling (2)
- version control systems (2)
- vorderer Augenabschnitt (2)
- 3D-Druck (1)
- 3D-Refraktion (1)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Aalener Schnell Satztest (1)
- Ablaufplan (1)
- Absolventen (1)
- Absolventenbefragung (1)
- Adjustment Process (1)
- Affliliate Marketing (1)
- Agency Theory (1)
- Alumnibefragung (1)
- Animation (1)
- Anleitung (1)
- Arbeitszufriedenheit (1)
- Argentina (1)
- Argentinien (1)
- Artificial Intelligence (1)
- Atropin (1)
- Augenlänge (1)
- Augenoptik-Branche (1)
- Augenoptikerbetrieb (1)
- Augenoptikgeschäft (1)
- Augenoptikmarkt (1)
- Ausbildung (1)
- Bachelorarbeit A (1)
- Bachelorarbeit KMU (1)
- Bank (1)
- Befragung (1)
- Beratungspsychologie (1)
- Beratungsstelle Aalen (1)
- Big Data (1)
- Binokularstörung; Hess-Schirm Test; PC-Hess Screen (1)
- Blog (1)
- Brillenfassung, UV-Durchlässigkeit (1)
- Broschüre (1)
- Business Process Modelling (1)
- Chemische Analyse (1)
- Chirp-Bera (1)
- Choroidal thickness (1)
- City Development (1)
- Cochlear Implantat (1)
- Comparison metrics (1)
- Content Marketing (1)
- Corporate Governance (1)
- Cross-Cultural Training (1)
- Cultural Heritage Marketing (1)
- DDC 620 (1)
- Deflektometrie (1)
- Defocus (1)
- Deinstleistung (1)
- Deutscher Corporate Governance Kodex (1)
- Deutschland / Augenoptiker-Ausbildungsverordnung (1)
- Dienstleistungsangebot (1)
- Diffusion (1)
- Digitization (1)
- Diskontinuität der ägyptischen Revolution (1)
- Diversity Marketing (1)
- Drop-Out-Quote (1)
- ETDRS (1)
- ETDRS-Tafeln (1)
- EVA (1)
- EXPEDIT (1)
- Edge Detection (1)
- Einfluss mechanischer Spannungen (1)
- Einheitlichkeit (1)
- Eisenverlust (1)
- Elektroband (1)
- Elektroblech (1)
- Engineering & allied operations (1)
- Englischtest; Online (1)
- Enke-Platte (1)
- Entwicklungsländer (1)
- Erblindung (1)
- Erfolgsfaktorenforschung (1)
- Erwerbstätigkeit (1)
- Ethik (1)
- Europäische Union (1)
- Exoskelett (1)
- Eye tracking (1)
- Finanzfunktion (1)
- Finanzkrise (1)
- Fixation (1)
- Food (1)
- Fragebogen (1)
- Freiburger Sprachtest; Fragebogen; Einsilber Sprachtest (1)
- Freizeitmusik (1)
- Funktionaloptometrie (1)
- Fusionstrainer (1)
- Game-Based Learning (1)
- German Corporate Governance Code (1)
- Germany (1)
- Geschlechterrollen (1)
- Geschäftsmodell (1)
- Gleichgewichtsstabilität (1)
- Gleitsichtbrille (1)
- Gleitsichtgläser (1)
- Grenzfrequenz (1)
- Heißluftgerät; Temperaturprofil (1)
- Hell-Dunkel-Wahrnehmung (1)
- High-End-Hörsystem (1)
- Höranstrengung (1)
- Hörfähigkeit (1)
- Hörfähigkeit malawischer Schüler; Alter 10-24 Jahre (1)
- Hörgerätverifikation (1)
- Hörgeschädigt; Hörgerät; NAL-NL2 Formel; DSL v5.0 Formel (1)
- Hörorgan (1)
- Hörqualität (1)
- Hörschädigung (1)
- Hörsystem (1)
- Hörsysteme (1)
- Hörtraining (1)
- IKEA (1)
- IOL Master 500 (1)
- Impulsschall (1)
- Inbound-Marketing (1)
- Indusrie 4.0 (1)
- Industrial Culture (1)
- Industrial Heritage (1)
- Inklusion (1)
- Intellektuelles Kapital (1)
- Inter-Test Reliabilität (1)
- Interview (1)
- Islamistischer Einfluss (1)
- KI (1)
- Kalkulation (1)
- Kameramessung (1)
- Kampimetrie (1)
- Kantendetektion (1)
- Kapitalgesellschaft (1)
- Kaufrecht (1)
- Keratokonus (1)
- Kind (1)
- Kinder (1)
- Kommunikationstraining (1)
- Kontaktlinsen-Service-System (1)
- Kontaktlinsensprechstunde (1)
- Kostenakzeptanz (1)
- Kreislaufwirtschaft (1)
- Kreuzzylinder (1)
- Kundengruppen (1)
- Kupplung (1)
- Lehrmethoden (1)
- Leistungssteigerung (1)
- Lerninhalt (1)
- Lernsoftware (1)
- Lernvideo, Verkaufsgespräch (1)
- Lernvideo, e-Learning, Leitfaden (1)
- Leuchtdichte Homogenität (1)
- Leuchtdichte, Radiospektrometer, Kalibrierung, Spiegelreflexkamera (1)
- Leuchtdichteverteilung (1)
- Lieferverkehr (1)
- Lions Club (1)
- Low-End-Hörsystem (1)
- Lärm (1)
- MATLAB (1)
- MATLAB; e-Learning-Plattform; Bachelorstudiengang (1)
- MVA (1)
- Magic-Audiometer (1)
- Magnetismus (1)
- Marketingkonzept (1)
- Marokko (1)
- Massenspektrometrie (1)
- Master Vision Science and Business (1)
- Masterarbeit AO (1)
- Materialeigenschaften (1)
- Mechanische Spannung (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Messmethode (1)
- Messsystem (1)
- Messtechnik (1)
- Messung von Kundenzufriedenheit (1)
- Multifocal contact lenses (1)
- Multivariate Analyse (1)
- Multivariate Statistik (1)
- Mundell-Fleming Modell (1)
- Musikverein (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Myopiekontrolle (1)
- Myopiemanagement (1)
- National/Organizational Culture (1)
- Neue Medien (1)
- Nintendo Wii; geschlechtsspezifisches Gleichgewicht (1)
- Ohrmodell (1)
- Omnichannel (1)
- Online-Distribution (1)
- Online-Shop (1)
- Online-Shop Systeme (1)
- Onlineportal (1)
- Operation (1)
- Optotypen (1)
- Orthokeratology (1)
- Perimetrie (1)
- Perspektiven des ägyptischen Marktes (1)
- Politik (1)
- Politische Entwicklung Ägyptens (1)
- Premiummarken (1)
- Primary Eye Care Provider (1)
- Printformat (1)
- Psychophysik (1)
- Pull-Marketing (1)
- RCS (1)
- Race Conditions (1)
- Ratgeber (1)
- Re- source Assignment Automation (1)
- Reaktivierung (1)
- Refraktionsbestimmung (1)
- Resource Allocation Algorithms (1)
- Resource Assignment Automation (1)
- Retest-Reliabilität (1)
- Retinopathia pigmentosa (1)
- Revolution (1)
- Risikoadjustierung (1)
- Risikoanalyse (1)
- Rotationsprinzip; Leistungssteigerung (1)
- Ruheständler (1)
- Rule Engines (1)
- SNR-Verhältnis (1)
- SWOT-Analyse (1)
- Satztest (1)
- Scanpath (1)
- Schalleigenschaft (1)
- Schnittkanteneinfluss (1)
- Schnittstellen (1)
- Schule (1)
- Screening (1)
- Sehen im Sport (1)
- Sehhilfe (1)
- Sehilfen (1)
- Senioren (1)
- Service (1)
- Share Repurchase (1)
- Sicherheitskupplung (1)
- Six Sigma (1)
- Social Media (1)
- Sphärisches Äquivalent (1)
- Spieleindustrie (1)
- Sportoptometrie (1)
- Sprachtest (1)
- Sri Lanka (1)
- Staff Assignment Algorithms (1)
- Stimmen; Attraktivitätsbewertung (1)
- Storytelling (1)
- Strategic analysis (1)
- Strategie, Unternehmensführung, AMVO, VaKE (1)
- Strategische Analyse (1)
- Streifenprojektion (1)
- Streifenprojektionsgerät (1)
- Studiengang Augenoptik (1)
- Studiengang Augenoptik und Hörakustik (1)
- Störgeräusch (1)
- T-Cut; Operation; Patientenzufriedenheit (1)
- TOCTOU (1)
- Technikfolgenabschätzung (1)
- Tiefeninterview (1)
- Tieftonkompression (1)
- Tobin´s Q (1)
- Tolerance of blur, PAL`s, Astigmatism, Blurtest, Pretest (1)
- UN-Kaufrecht (CISG) (1)
- Umsatzsteuer (1)
- Umweltanalyse (1)
- Undervaluation (1)
- United Nations Convention on Contract for the international Sale of Goods (CISG) (1)
- Unschärfetoleranz , Gleitsichtgläser, Astigmatismus , Blurtest, Pretest (1)
- Unternehmensbewertung (1)
- Unternehmenserfolg (1)
- Unternehmensführung (1)
- Unverträglichkeit (1)
- Unzufriedenheit (1)
- Usability (1)
- Verbraucherberatung (1)
- Verkauf (1)
- Verlaufskontrolle; elektrophysiologisches Verfahren (1)
- Versorgungskapazität (1)
- VertiGuard-System (1)
- Vertrieb (1)
- Visual search (1)
- Vorderkammertiefe (1)
- Wahlpflichtmodul; internationale Optometrie (1)
- Web 2.0 (1)
- Web Application Security Testing (1)
- Weblog (1)
- Webportal (1)
- Webseite (1)
- Weinanalytik (1)
- Werbekampagne ZVA (1)
- Wertorientierung (1)
- Wirtschaftskrise (1)
- World Wide Web 2.0 (1)
- Zufriedenheitsmessung (1)
- Zyklofusionstest (1)
- albinism (1)
- artificial consciousness (1)
- artificial intelligence (1)
- augenoptischer Betrieb (1)
- augmented virtuality (1)
- automatical telephone audiometry, hearing aid fitting (1)
- automatisierter Telefonhörtest, Hörgeräteanpassung (1)
- automotive supplier (1)
- autonome Auslegung (1)
- autonomous interpretation (1)
- berufliche Perspektiven (1)
- blindness (1)
- business process management (1)
- business process mining (1)
- care capacity (1)
- code coverage (1)
- contact lens-induced papillary conjuctivitis CLPC (1)
- corneal cross linking (1)
- customized (1)
- cyber-physische Systeme (1)
- data pipelines (1)
- data stream processing (1)
- demografischer Wandel (1)
- deutsche Spitzengastronomie (1)
- digitaler Zwilling (1)
- doppelstöckige Personengesellschaften (1)
- dänische Richtlinien (1)
- economic crisis (1)
- electric vehicle (1)
- empirische Untersuchung (1)
- empirische Untersuchung; Kontaktlinsen; Kundenzufriedenheit (1)
- environmental analysis (1)
- erfolgreiches Geschäftsmodell, optometrische Dienstleistungen, Wettbewerb (1)
- event stream processing (1)
- event-driven architecture (1)
- follicular-like conjunctivitis associated with siliconhydrogels FoCoSi (1)
- fundamental breach (1)
- gender roles (1)
- genes (1)
- giant papillary conjuctivitis GPC (1)
- graph analysis (1)
- graph embeddings (1)
- grenzüberschreitender Leistungsverkehr (1)
- grenzüberschreitender Lieferverkehr (1)
- hybrid vehicle (1)
- i.Profiler (1)
- integrated development environments (1)
- internationale Schwerhörigenhilfe (1)
- internationaler Währungsfond (1)
- künstliche Intelligenz (1)
- learning videos, e-learning, guideline (1)
- low vision (1)
- luminance distribution (1)
- luminance homogeneity (1)
- luminance, radio spectrometer, calibration, reflex-camera (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- mixed reality (1)
- monokulare Refraktionsbestimmung (1)
- myopia management (1)
- optisches Phänomen (1)
- optometric and optical companies (1)
- optometrische Dienstleistungen (1)
- peripheral myopic defocus (1)
- powertrain (1)
- proaktive Ansprache (1)
- process analysis (1)
- process mining (1)
- psychophysics (1)
- repeatability (1)
- reproduzierbare Impulsschallquelle; Dosimeterprojekt (1)
- requirements traceability (1)
- rule-based expert system (1)
- soft multifocal contact lens (1)
- software requirements traceability (1)
- software test coverage (1)
- software test traceability (1)
- software testing (1)
- software verification and validation (1)
- specialty coffee (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- strategy, management, AMVO, VaKE (1)
- studentische Kontaktlinsensprechstunde (1)
- subjektive Refraktionen (1)
- successful business-model, optometrical service, competition (1)
- sustainability (1)
- two-rod test (1)
- uniformity (1)
- vision therapy (1)
- visual acuity (1)
- web-based Marketing (1)
- wesentliche Vertragsverletzung (1)
- winIPRO (1)
- Ägypten (1)
- Übereinkommen über Verträge über den internationalen Warenkauf (1)
- Überlastschutz (1)
Institute
- Optik und Mechatronik (131)
- Wirtschaftswissenschaften (122)
- Maschinenbau und Werkstofftechnik (81)
- Augenoptik und Hörakustik (43)
- Elektronik und Informatik (42)
- Internationale Betriebswirtschaft (18)
- Chemie (12)
- Maschinenbau/Fertigungstechnik (2)
- Informatik (1)
- Mechatronik (1)
„Wie hört Nkhoma?“ Studie zur Untersuchung der Hörfähigkeit malawischer Schülerinnen und Schüler
(2012)
In Nkhoma (Malawi) wurden im Zeitraum von Februar bis Mai 2010, 143 Schüler im Alter von 10 – 24 Jahren auf ihr Hörvermögen getestet. Nach der Begutachtung des äußeren Ohres, des Gehörgangs und des Trommelfells wurden die Hörschwellen mit einem Handaudiometer des Typs MA 33 von Maico ermittelt. Anhand eines Fragebogens wurden wichtige Hintergrundinformationen und Einflussfaktoren vor Beginn der Messung erfasst. Diese beinhalteten persönliche Hörgewohnheiten, wie zum Beispiel das Spielen eines Instrumentes oder das Musikhören mit einem MP3- Player. Auch physiologische und medizinische Aspekte wurden anhand des Fragebogens erfasst, beispielsweise das Auftreten von Tinnitus und Mittelohrentzündungen oder die Einnahme von Medikamenten. Die gesammelten Daten wurden statistisch aufbereitet und ausgewertet. Von den 143 Schülerinnen und Schülern wiesen 62 % eine unauffällige Hörschwelle auf. Bei 38 % der Untersuchten war ein Hörverlust > 25 dB festzustellen. Hierunter waren 16 % der Hörstörungen Schallleitungs- und 22 % Schallempfindungsstörungen. Bei der Untersuchung auf Zusammenhänge zwischen Eigenschaften aus den Fragebögen und einem Hörverlust ergab sich in keiner Beziehung eine Signifikanz. Knapp ein Viertel aller Schüler hatten eine auffällig starke Cerumenbildung. Die Analyse von Mittelohrentzündungen in Verknüpfung mit einem Hörverlust ergab, dass mit einer Irrtumswahrscheinlichkeit von 6 % ein Zusammenhang besteht.
Die vorliegende Querschnittsstudie befasst sich mit dem komplexen Thema der „Inklusion“. Dabei ist das Ziel, dass behinderte Menschen gleichberechtigt an der Gesellschaft teilhaben, ohne Diskriminierung oder Ausgrenzung. Sie sollen die gleichen Bildungschancen erhalten wie nicht behinderte Menschen. In dieser Arbeit wurden die Einschätzungen von Eltern hörgeschädigter Kinder im Grundschulalter bezogen auf das Thema Inklusion ausgewertet. Material und Methode: Der erstellte Fragebogen, besteht aus 4 Abschnitten und 39 Fragen. Die Einschätzungen von 49 Müttern und 40 Vätern hörgeschädigter Kinder wurden ausgewertet. Zur Auswertung der Fragen wurden die besuchten Schulformen und die Sichtweisen von Müttern und Vätern herangezogen. Ergebnisse: Als Ergebnis der Studie war festzustellen, dass Inklusion noch nicht zufriedenstellend umgesetzt wurde. Es besuchen weiterhin mehr Schüler eine sonder-pädagogische Schule als eine allgemeine Schule. Außerdem ist die Form der Einzelintegration in den allgemeinen Schulen stark vertreten. Im Befinden der Schüler waren keine gravierenden Unterschiede zwischen den Schulformen festzustellen. Die meisten Kinder der Befragten besuchen die Schule gern. Dennoch zeigten die Ergebnisse, dass die Schüler der allgemeinen Schule nach einem Schultag tendenziell erschöpfter sind, als die der sonderpädagogischen Schulen. Die Einschätzungen der Eltern zu ihrem eigenen Wohlbefinden ließen erkennen, dass die Eltern allgemein beschulter Kinder belasteter sind. Diskussion: Ursachen für die Ergebnisse können eine unzureichende Beratung der Betroffenen sein oder die noch zu geringen Erfahrungen der allgemein bildenden Schulen im Umgang mit hörgeschädigten Kindern. Nicht ausreichend umgesetzte Rahmenbedingungen und die Problematik der bundesweit unterschiedlichen Schulgesetze können ebenfalls für die schleppende Umsetzung von Inklusion verantwortlich sein. Schlussfolgerungen: Für die Umsetzung von Inklusion ist die Zusammenarbeit verschiedener Institutionen von großer Bedeutung. Gerade das Wissen Betroffener und derjenigen, die erfolgreich hörgeschädigte Kinder erziehen und unterrichten, sollte Berücksichtigung finden. Bis ein Umdenken flächendeckend stattgefunden hat, ist noch viel Aufklärungsarbeit zu leisten. Dennoch scheint der Wunsch nach gleichberechtigter Teilhabe präsent und umsetzbar zu sein.
Ziel dieser Bachelorthesis ist die Entwicklung eines zukunftsfähigen Geschäftsmodells für Optometristen in deutschsprachigem Raum. Die augenoptische Branche ist aufgrund der intensiven Konkurrenzsituation durch einen starken Preisdruck gekennzeichnet. Für inhabergeführte Fachgeschäfte wird es zunehmend schwieriger gegenüber Filialisten und dem Online Handel zu bestehen. Zugleich befindet sich die Branche in einem Umbruch. Immer häufiger werden Weiterbildungen in Richtung Optometrie angeboten. In dieser Bachelorthesis wird untersucht, ob und wie durch das Angebot optometrischer Dienstleistungen wirtschaftliche Erfolgsfaktoren erreicht werden können.
Hierfür wird zunächst die augenoptische Branche genauer betrachtet und der Bedarf und die Nachfrage an Optometrie ermittelt. Darauf aufbauend wird das Geschäftsmodell des Primary Eye Care Providers entwickelt. Dem Kunden wird hier eine Komplettversorgung rund um das Sehen angeboten, sowohl an Sach- als auch an Dienstleistungen.
Im empirischen Teil der Arbeit wird anhand einer Umfrage geprüft, ob dieses Geschäftsmodell für Augenoptiker zukunftsfähig sein kann. An dieser Umfrage beteiligten sich 80 Augenoptiker aus dem deutschsprachigen Raum (zum größten Teil aus Deutschland).
Das Geschäftsmodell des Primary Eye Care Providers stellt sich als ein interessantes Geschäftsmodell für Optometristen heraus. Dabei erfolgt nicht nur die Sehstärkenbestimmung beim Augenoptiker, sondern auch eine umfassende Augenuntersuchung. So können Augenerkrankungen frühzeitig erkannt und die bestmögliche Versorgung dieses wichtigen Organs gesichert werden.
Young but not Naive: Leaders of Tomorrow Expect Limits to Digital Freedom to Preserve Freedom
(2021)
Wie werden wir digital?
(2020)
Ziel der Bachelor Thesis ist die Analyse der Werbewirksamkeit der Werbekampagne des ZVA “1xO” – gemessen an der Bekanntheit der Kampagne. Dabei geht es im Wesentlichen um die regelmäßige, jährliche und kompetente Überprüfung der Sehleistung durch die Augenoptiker. Hintergrund der Veröffentlichung der Kampagne ist der schleichende Prozess der Sehleistungsveränderung. Viele Menschen nehmen unbewusst nicht wahr, dass ihr Sehvermögen mangelhaft ist und wie sie optimaler mithilfe einer Korrektion sehen könnten. Basierend auf wissenschaftlichen Studien und einer repräsentativen Kundenbefragung beschäftigt sich diese wissenschaftliche Arbeit unter anderem mit einer Bestandsaufnahme über die Veränderung der Sehfähigkeit von Brillen--‐und Kontaktlinsenträgern sowie Nicht--‐ Brillen--‐oder Kontaktlinsenträgern. Des Weiteren gibt sie Aufschluss über die derzeitige Teilnahme an regelmäßigen Untersuchungen durch den Augenarzt oder den Augenoptiker. Sie zeigt im Weiteren wie häufig und regelmäßig, aus Sicht und Meinung der Deutschen, eine Sehprüfung von einer professionellen Person ausgeführt werden sollte. Interessant zu sehen ist ebenfalls, wie die Menschen ihre derzeitige Sehleistung selbst einschätzen, um zu zeigen wieviele verbreitete Zweifel über das Sehvermögen entstehen und die Kernaussage der Kampagne zu unterstützen. Um klären zu können, welche Veränderungen, Maßnahmen oder Verbesserungen seitens der Augenoptiker getroffen werden müssen um eine ganzheitliche Kundenbindung zu erlangen, spielen Kundenzufriedenheitsbefragungen eine ebenso entscheidende Rolle für die Heranführung der Deutschen an regelmäßigere Sehtests. Dabei ist ebenso wichtig feststellen zu können, ob die Augenoptiker einen Wettbewerbskampf mit Onlineanbietern eingehen müssen oder die Kundentreue gegenüber den Augenoptikern stark genug ist. Die Kundentreue und Kundenzufriedenheit ist der Grundbaustein für eine optimale Aufklärung über regelmäßige Kontrollen der Sehleistung seitens der Augenoptiker.
Der demografische Wandel stellt die deutsche Arbeitswelt vor neue Herausforderungen.
Denn die schrumpfende Bevölkerungszahl wird zu einer Lücke in
der Erwerbsbevölkerung führen, weshalb neues Arbeitskräftepotenzial reaktiviert
werden sollte. Die vorliegende Bachelorthesis beschäftigt sich daher mit den
Möglichkeiten einer Wiedereingliederung von Ruheständlern in das Erwerbsleben.
Ziel ist es zu klären, ob und zu welchen Bedingungen diese Personengruppe
bereits erwerbsmäßig arbeitet und welche Anreize, Erwartungen und
Angebote erfüllt werden müssten, um (noch) mehr Ruheständler für Erwerbstätigkeiten
reaktivieren zu können. Die Forschungsfrage wird auf Grundlage der
Auswertung von aktueller Fachliteratur und Befragungen mit Ruheständlern
sowie Unternehmen diskutiert. Die Arbeit gliedert sich in sechs Kapitel. Im ersten
Kapitel werden Problemstellung, Zielsetzung und Abgrenzung sowie der Aufbau
dargestellt. Kapitel zwei erläutert den demografischen Wandel Deutschlands und
dessen Herausforderungen und Auswirkungen. Das dritte Kapitel vermittelt die
Voraussetzungen für eine Beschäftigung von Ruheständlern. Maßnahmen zur
Bewältigung demografischer Herausforderungen mittels Reaktivierung von
Ruheständlern werden im vierten Kapitel vorgestellt. Die empirischen Ergebnisse
der Umfragen werden in Kapitel fünf illustriert. Das darauffolgende Kapitel sechs
komplettiert die vorliegende Arbeit mit einem Fazit. Im Ergebnis wird deutlich,
dass mehr als die Hälfte der interviewten Unternehmen bereits Ruheständler
beschäftigen. Die Erwartungen dieser Personengruppe an die Arbeitsbedingungen
einer erwerbsmäßigen Tätigkeit stimmen weitgehend mit der
betrieblichen Praxis überein. Allerdings ist die Quote der befragten Rentner, die
in ihrem Ruhestand weiterarbeiten deutlich geringer als erwartet.
Web-based Marketing ist der neueste Trend ( Pusler) in der Unternehmenskommunikation. Das sogenannte Phänomen „Web 2.0“ bietet viele Möglichkeiten und Herausforderungen. Im Laufe dieser Arbeit wird analysiert welche Erfolge und Gefahren sich in der online Kommunikation verbergen und welche Chancen und Risiken das Web für Premiummarken im Food-Bereich bietet.
Das Ziel dieser Bachelorarbeit ist es eine Informationsbroschüre zu erstellen. Diese
soll auf die Probleme, die durch Kurzsichtigkeit entstehen, hinweisen und Möglichkeiten zur Kontrolle der Myopieprogression vorstellen. Dabei wird der Fokus auf die Orthokeratologie gelegt. Zusätzlich soll Optometristen und Augenoptikern ein Überblick über die verschiedenen Methoden zur Myopiekontrolle hinsichtlich ihrer Effektivität Sicherheit gegeben werden.
WAR FOR TALENTS MEETS FACIAL EXPRESSION - leveraging recruiting videos in professional service firms
(2020)
Der Mensch hat sechs Sinne, den Hörsinn und Gleichgewichtssinn (Ohren), den Geruchssinn (Nase), den Tastsinn (Haut), den Geschmackssinn (Zunge) und natürlich den wichtigsten Sinn, den Sehsinn (Augen), der ca. 80% unserer bewussten Sinneseindrücke ausmacht. Aber das war nicht immer so, nämlich erst seit der Erfindung des Buchdruckes, also ab dem 16. Jahrhundert. Da „verlor das Ohr seine vorrangige Bedeutung als Vermittler des Geistigen, da man nunmehr Wissen auch durch Lesen erwerben konnte. Im Gegensatz zur Antike gilt heute das Auge im Allgemeinen als ‚edelster Sinn‘ [Hellbrück 1993]“ [1]. Dies zeigt sich vor allem daran, da wir unsere Augen jeden Tag zur Aufnahme und Weiterleitung visueller Reize an das Gehirn benutzen und unser Handeln und Tun darauf am meisten ausrichten.
Doch trotz der aufbauenden Wahrnehmungskette, angefangen vom visuellen Reiz, über die Verarbeitung und Wahrnehmung im Gehirn, bis hin zur Wiedererkennung und schließlich zum Handeln, lässt sich dieses komplexe und ausgeklügelte System unseres Sehens in manchen Situationen zu leicht austricksen. Dies lässt auf Fehler schließen, die bei der Verarbeitung und Umrechnung von realen und dreidimensionalen Umweltreizen, die auf einer zweidimensionalen Netzhaut abgebildet werden, entstehen. Folglich nehmen wir diese Sachen anders wahr, als sie in Wirklichkeit sind. Daraus lassen sich eben zweidimensionale, geometrisch-optische, oder dreidimensionale, optisch-räumliche Täuschungen bauen. Letztere sind meist monokular besser zu sehen, wenn nicht sogar nur monokular zu sehen.
Meine Aufgabe in dieser Arbeit war zum einen der Bau und Beschreibung zweier optischer Hell-Dunkel-Wahrnehmungstäuschungen, um die Anzahl der optischen Phänomene in der Scheune von Herrn Lingelbach in Leinroden aufzustocken. Zum anderen sollte auf die Geschichte dieser Hell-Dunkel-Wahrnehmung eingegangen werden.
Ich danke allen, die zum Gelingen dieser Arbeit beigetragen haben. Als erstes natürlich möchte ich mich bei Prof. Dr. Bernd Lingelbach für seine Unterstützung bedanken. Ein großer Dank gilt natürlich auch meinen Eltern für ihre Geduld und für die finanzielle Unterstützung, als auch dafür, dass sie mir durch handwerkliches Geschick geholfen haben. Als nächstes danke ich Herrn Göde von der Firma „Göde Grafik & EDV“ für die Ausdrucke und Zuschnitte. Abschließend danke ich auch noch den Probanden, die sich für die Tests zur Verfügung gestellt haben.
Ziel der vorliegenden Arbeit ist es Studierenden des Studiengangs Augenoptik/Augenoptik und Hörakustik der Hochschule Aalen aufzuzeigen, welche Chancen das Studiensemester „Internationale Optometrie“ sowie die Anfertigung der Abschlussarbeit im Ausland oder ein Praxissemester im Ausland bergen und in wieweit ein solches Semester von Vorteil ist. Die Arbeit ist ein Leitfaden und soll als Entscheidungs- bzw. Orientierungshilfe fungieren. Es zeigt im Hinblick auf voraussichtliche Neuerungen, welche die Zukunft verspricht, den Studierenden auf, welche Relevanz internationale Optometrie hat und in welchem Wandel sich der augenoptische Markt zurzeit befindet. Studierende sollen motiviert und begeistert werden, sich ein Auslandssemester zuzutrauen. Um dies zu erreichen werden allgemeine Informationen zur Zukunft der Optometrie in Deutschland und Europa gegeben, sowie spezifische Informationen zu den unterschiedlichen Ländern.
Neben der subjektiven Bewertung der Hörsystemanpassung durch die Kunden und die Verifikation durch die Akustikerin/den Akustiker, in der Regel insitu, ist auch die Validierung einer Hörsystemanpassung nötig bzw. vorgeschrieben.
Der in der Hörgeräteakustik verbreitetste Test, um das Sprachverstehen zu testen, ist auch weiterhin der Freiburger Sprachtest.
Dieser findet nicht nur Anwendung bei Akustikerinnen und Akustikern, sondern auch bei HNO Ärztinnen und Ärzten. Somit ist er aus der Praxis nicht wegzudenken.
Neben den bekannten Problemen der ungleichen Listen und der mangelnden Eignung des Freiburger Sprachtests für Messungen im Störschall, haben jedoch alle Sprachtests gemein, dass sie nur akustisch und nicht visuell dargeboten werden.
Viele Schwerhörige, auch HörgeräteträgerInnen, nutzen jedoch im realen Leben neben der reinen akustischen auch die visuelle Information über das Mundbild der Sprecherin / des Sprechers. Diese Zusatzinformation kann die subjektive Höranstrengung deutlich reduzieren.
In dieser Studie wurde die Sprachverständlichkeit (SV) im Freiburger Sprachtest im Freifeld mit und ohne Videomaterial bei insgesamt 22 Personen und 6 Normalhörenden untersucht.
VR-V&V
(2023)
To build quality into a software (SW) system necessitates supporting quality-related lifecycle activities during the software development. In software engineering, software Verification and Validation (V&V) processes constitute an inherent part of Software Quality Assurance (SQA) processes. A subset of the V&V activities involved are: 1) bidirectional traceability analysis of requirements to design model elements, and 2) software testing. Yet the complex nature of large SW systems and the dependencies involved in both design models and testing present a challenge to current V&V tools and methods regarding support for trace analysis. One of software’s essential challenges remains its invisibility, which also affects V&V activities. This paper contributes VR-V&V, a Virtual Reality (VR) solution concept towards supporting immersive V&V activities. By visualizing requirements, models, and testing artifacts with dependencies and trace relations immersively, they are intuitively accessible to a larger stakeholder audience such as SQA personnel while supporting digital cognition. Our prototype realization shows the feasibility of supporting immersive bidirectional traceability as well as immersive software test coverage and analysis. The evaluation results are based on a case study demonstrating its capabilities, in particular traceability support was performed with ReqIF, ArchiMate models, test results, test coverage, and test source to test target dependencies.
With the increasing pressure to deliver additional software functionality, software engineers and developers are often confronted with the dilemma of sufficient software testing. One aspect to avoid is test redundancy, and measuring test (or code or statement) coverage can help focus test development on those areas that are not yet sufficiently tested. As software projects grow, it can be difficult to visualize both the software product and the software testing area and their dependencies. This paper contributes VR-TestCoverage, a Virtual Reality (VR) solution concept for visualizing and interacting with test coverage, test results, and test dependency data in VR. Our VR implementation shows its feasibility. The evaluation results based on a case study show its support for three testing-related scenarios.
As systems grow in complexity, the interdisciplinary nature of systems engineering makes the visualization and comprehension of the underlying system models challenging for the various stakeholders. This, in turn, can affect validation and realization correctness. Furthermore, stakeholder collaboration is often hindered due to the lack of a common medium to access and convey these models, which are often partitioned across multiple 2D diagrams. This paper contributes VR-SysML, a solution concept for visualizing and interacting with SysML models in Virtual Reality (VR). Our prototype realization shows its feasibility, and our evaluation results based on a case study shows its support for the various SysML diagram types in VR, cross-diagram element recognition via our backplane followers concept, and depicting further related (SysML and non-SysML) models side-by-side in VR.
VR-SysML+Traceability
(2023)
As systems grow in complexity, the interdisciplinary nature of systems engineering makes the visualization and comprehension of the underlying system models challenging for the various stakeholders. This, in turn, can affect validation and realization correctness. Furthermore, stakeholder collaboration is often hindered due to the lack of a common medium to access and convey these models, which are often partitioned across multiple 2D diagrams. This paper contributes VR-SysML, a solution concept for visualizing and interacting with Systems Modeling Language (SysML) models in Virtual Reality (VR). Our prototype realization shows its feasibility, and our evaluation results based on a case study shows its support for the various SysML diagram types in VR, cross-diagram element recognition via our Backplane Followers concept, and depicting further related (SysML and non-SysML) models side-by-side in VR.
Repeatable processes are fundamental for describing how enterprises and organizations operate, for production, for Industry 4.0, etc. As digitalization and automation progresses across all organizations and industries, including enterprises, business, government, manufacturing, and IT, evidence-based comprehension and analysis of the processes involved, including their variations, anomalies, and performance, becomes vital for an increasing set of stakeholders. Process Mining (PM) relies on logs or processes (as such evidence-based) to provide process-centric analysis data, yet insights are not necessarily visually accessible for a larger set of stakeholders (who may not be process or data analysts). Towards addressing certain challenges described in the Process Mining Manifesto, this paper contributes VR-ProcessMine, a solution for visualizing and interacting with PM results in Virtual Reality (VR). Our realization shows its feasibility, and a case-based evaluation provides insights into its capabilities.
VR-GitCity
(2023)
The increasing demand for software functionality necessitates an increasing amount of program source code that is retained and managed in version control systems, such as Git. As the number, size, and complexity of Git repositories increases, so does the number of collaborating developers, maintainers, and other stakeholders over a repository’s lifetime. In particular, visual limitations of command line or two- dimensional graphical Git tooling can hamper repository comprehension, analysis, and collaboration across one or multiple repositories when a larger stakeholder spectrum is involved. This is especially true for depicting repository evolution over time. This paper contributes VR-GitCity, a Virtual Reality (VR) solution concept for visualizing and interacting with Git repositories in VR. The evolution of the code base is depicted via a 3D treemap utilizing a city metaphor, while the commit history is visualized as vertical planes. Our prototype realization shows its feasibility, and our evaluation results based on a case study show its depiction, comprehension, analysis, and collaboration capabilities for evolution, branch, commit, and multi-repository analysis scenarios.
The increasing demand for software functionality necessitates an increasing amount of program source code that is retained and managed in version control systems, such as Git. As the number, size, and complexity of Git repositories increases, so does the number of collaborating developers, maintainers, and other stakeholders over a repository’s lifetime. In particular, visual limitations of Git tooling hampers repository comprehension, analysis, and collaboration across one or multiple repositories with a larger stakeholder spectrum. This paper contributes VR-Git, a Virtual Reality (VR) solution concept for visualizing and interacting with Git repositories in VR. Our prototype realization shows its feasibility, and our evaluation results based on a case study show its support for repository comprehension, analysis, and collaboration via branch, commit, and multi-repository scenarios.
VR-EDStream+EDA
(2023)
With increasing digitalization, the importance of data and events, which comprise its most fundamental level, cannot be overemphasized. All types of organizations, including enterprises, business, government, manufacturing, and the supporting IT, are dependent on these fundamental building blocks. Thus, evidence-based comprehension and analysis of the underlying data and events, their stream processing, and correlation with enterprise events and activities becomes vital for an increasing set of (grassroot or citizen) stakeholders. Thus, further investigation of accessible alternatives to visually support analysis of data and events is needed. This paper contributes VR-EDStream+EDA, a solution for immersively visualizing and interacting with data and event streams or pipelines and generically visualizing Event-Driven Architecture (EDA) in Virtual Reality (VR). Our realization shows its feasibility, and a case-based evaluation provides insights into its capabilities.
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Veränderungen der Rolle von Controllern in Großkonzernen – Ergebnisse einer empirischen Erhebung
(2021)
Die im Rahmen dieser Bachelor Thesis "Verzeichnung und Brillenanpassung - Eine Visualisierung in Form von Drehbüchern" erarbeiteten Drehbücher dienen als Vorlage zur Erstellung von Lehrvideos in Form von Kurzfilmen mit einer Länge von drei bis vier Minuten.
Diese Kurzfilme sollen Kunden und Mitarbeitern der Firma Schneider das Verständnis für das jeweilige optische Thema erleichtern.
Es wurden Drehbücher zu den Themen "Anpassung und Zentrierung von Brillen" und "Verzeichnung und Schaukeleffekt bei Gleitsichtgläsern" erstellt.
Die angefertigten Drehbücher ermöglichen mit genauen Regieanweisungen und Layouts die spätere Umsetzung durch Dritte. Verschiedene Situationen und Darstellungen werden mit Skizzen und Anmerkungen vertieft. Die jeweiligen Bilder unterstützen die Veranschaulichung der einzelnen Szenen und erleichtern die Umsetzung vom Drehbuch zum Film. Zusätzlich gibt es in beiden Drehbüchern einen Text für den Sprecher.
Mit dieser Erzählstimme werden im Video die einzelnen Abbildungen und Szenen für den Betrachter leicht verständlich erklärt. Zudem wurde von beiden Drehbüchern ein Storyboard angefertigt, welches mit Kameraanweisungen und Szenenbeschreibungen den zeitlichen Ablauf des Videos darstellt.
Zusätzlich zu den Drehbüchern wurden die Grundlagen beider Themen in jeweils einem theoretischen Teil zusammenfassend erklärt.
Lebenslanges Lernen gewinnt in der heutigen Zeit immer mehr an Bedeutung, denn die unverzichtbaren Wissensmengen wachsen und somit auch der ständige Auffrischungsbedarf. Beides kann der Mensch nur mit entsprechenden Lehr- und Lernmethoden schaffen.
Mit der stetigen Weiterentwicklung der Technologien und den hohen Ansprüchen der Menschen wachsen die Anforderungen an die Augenoptiker. Immer mehr Fachwissen wird benötigt. Aber die Fachkompetenz allein hilft keinem Augenoptiker bei seinen Dienstleistungen, der Beratung und dem Verkauf seiner Produkte. Das Wissen über die Beratungspsychologie macht einen erheblichen Anteil aus. Also ist es wichtig, den Augenoptikern eine Weiterbildungsmöglichkeit anzubieten, anhand derer sie ihr Wissen ausbauen und verbessern können. In Hinblick auf andere Nationen, in denen nicht so gut ausgebildete Augenoptiker zu finden sind, wie in Deutschland, muss eine gute Versorgung der Kunden gewährleistet werden. Ein gutes Weiterbildungsprogramm kann hier helfen, die Fachkompetenz zu verbessern.
Ziel dieser Bachelorthesis ist es, neben der Erarbeitung der theoretischen Grundlagen des Game-Based Learnings, ein Drehbuch zu erstellen. Dieses Drehbuch soll als Grundlage für ein Digital Game-Based Learning zum Beraten und Verkaufen in der Augenoptik dienen. Des Weiteren soll es im Studiengang Augenoptik / Augenoptik & Hörakustik als Basis für weitere Dreharbeiten zur Verfügung stehen. Das Drehbuch wird dabei so verfasst, dass der Inhalt möglichst nah an einem echten Verkaufs- und Beratungsgespräch liegt. Es soll später den Lernenden als Leitfaden dienen.
Abschließend geht es um die Klärung der Frage, ob der Einsatz des Digital Game-Based Learning in der Augenoptik sinnvoll ist. Fakt ist, dass lebenslanges Lernen nur durch Nutzung von Informations– und Kommunikationstechnologien gewährleistet werden kann.
Motivation dieser Bachelorthesis war die Weiterführung eines Projekts im Rahmen eines Wahlpflichtmoduls zwei Semester zuvor, bei dem mittels des Wii- Balance-Boards die Gleichgewichtsstabilität in Ruhe und Lärm miteinander verglichen wurde.
Ziel der jetzigen Arbeit war es, herauszufinden, ob es signifikante Unterschiede der posturalen Kontrolle in Ruhe und in Lärm gibt, gemessen zum einen mit dem VertiGuard®-System, zum anderen mit der Enke-Platte. Des Weiteren sollte verglichen werden, ob sich die Gleichgewichtsstabilität in Lärm genauso gut trainieren lässt wie in Ruhe. Die Probanden wurden audiologisch eingangsuntersucht und in WHO- Gruppen unterteilt, da man ebenfalls herausfinden wollte, ob der individuelle Hörverlust Einfluss auf das Gleichgewicht des Probanden hat. Zu guter Letzt stellte sich die Frage, ob das VertiGuard®-System auf die gleichen Ergebnisse kommt wie die Enke-Platte.
An dieser Studie nahmen 17 Probanden teil, die folgende Anforderungen erfüllten:
Die Probanden mussten das 60. Lebensjahr vollendet haben. Allgemeine Schwindelsymptomatik, deren Ursache unklar ist, war Voraussetzung. Ein vorhandener Hörverlust war wünschenswert, Normalhörigkeit allerdings kein Ausschlusskriterium. Schwindelsymptomatik, die von pathologischen Erkrankungen wie Morbus Menière ausgeht, war Grund für eine Verweigerung der Teilnahme.
Der Lärm, der für einen Teil der Studie benötigt wurde, war eine eigens dafür erstellte Tonspur, die vor Studienanlauf mit einem Kunstkopf von Head Acoustics an einer Bundesstraße und einer stark befahrenen Stadtkreuzung aufgenommen wurde.
Die Probanden mussten nach der audiologischen Voruntersuchung einen gSBDT mit dem VertiGuard® durchlaufen und ein Balance-Screening mit der Enke-Platte absolvieren. Bei dem darauffolgenden Termin wurde der gleiche Ablauf nochmals in Lärm durchgeführt. Auf Grund des VertiGuard®-Ergebnisses wurden fünf Trainingstermine vereinbart, bei denen an jedem Trainingstermin fünfmal hintereinander das vorgeschlagene Training des VertiGuard® absolviert wurde. Nach diesem Training wurde ein Abschluss-gSBDT und ein abschließendes Balance-Screening durchgeführt.
Anhand dieser erhobenen Daten wurden mittels diverser statistischer Tests die oben erwähnten Hypothesen überprüft.
Dabei stellte sich heraus, dass der individuelle Hörverlust bei der Auswertung des Sturzrisikos mit dem VertiGuard® keinen Einfluss hatte. Im Gegensatz dazu ergaben sich bei der Auswertung mit der Enke-Platte aber Unterschiede zwischen den einzelnen WHO-Gruppen, die tendenziell darauf schließen lassen, dass der Hörverlust einen Einfluss haben könnte, der aber auch altersbedingt zustande gekommen sein könnte.
Außerdem zeigte sich, dass Lärm keinen Einfluss auf das Gleichgewicht hat. Das Training in Lärm zeigte effektive Erfolge. Dieses Ergebnis konnte sowohl mit dem VertiGuard®, als auch mit der Enke-Platte beobachtet werden.
Abstract Comparative measurements of elder dementia patients using multiple choice auditory graphic interactive check (MAGIC) and standard audiometry Setting Considering the demographic change of Germany (Statistisches Bundesamt, 2011) and the accordingly increasing risk of age-related diseases (Neubauer, et al., 2011), this research analyzes the measurement of deafness of probands who suffer from dementia, aged between 69 and 95 years with an average age of 86,3 years. One characteristic of dementia disease is communication problems (Alzheimer, 1911; Richter, 2003), which can be intensified by an eventually coexisting deafness (Lin, et al., 2011). Object of investigation The investigation, informing this research, engages in the question, wether an established audiometry for children can simplify the screening of hearing of elder people suffering from dementia and to what extent an additional loss of hearing can be detected. Research method The measurements were performed with a standard audiometry and compared to a multiple choice auditory graphic interactive check (MAGIC) (PATH, 2011) to analyze the grade of deafness of 18 nursing home residents (72 % female, 28 % male) who were diagnosed with dementia beforehand. The used ranges of frequencies in this measurement were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. Results Out of this group of probands 7 persons could be tested with the standard audiometry and 6 persons could be tested with the MAGIC. 5 persons could be tested also with the standard audiometry and the MAGIC. It was noticeable, that more probants were diagnoseable with the standard audiometry than there were with the MAGIC. During conducting the measurements it was often difficult for the probands to follow the sequence of the MAGIC. Conclusions The utilisation of the MAGIC in its current design is only restricted recommendable related to people suffering from dementia at present and often must be replaced by a the standard audiometry. The measurements performed in the context of this rersearch show the importance and necessity to diagnose a loss of hearing, since all probands showed signs of deafness. Keywords: demographic progress - dementia – MAGIC – standard audiometry
Im Rahmen der vorliegenden Bachelorarbeit wurden bei 41 Probanden sowohl objektive als
auch subjektive Refraktionsbestimmungen durchgeführt. Bei den Probanden wurde die
klassische monokulare Refraktionsbestimmung mit dem Kreuzzylinder durchgeführt. Im
Anschluss an diese Messung, wurde ein monokularer Feinabgleich unter binokularen
Bedingungen für Sphäre, Zylinder und Achse am Zyklofusionstest durchgeführt. Ziel ist es zu
prüfen, ob zum einen die monokulare Refraktion unter binokularen Bedingungen am
Zyklofusionstest ein gleichwertiges Verfahren zur Refraktionsbestimmung ist wie die
monokulare Refraktion und zum anderen ob sich unter binokularen Bedingungen eine andere
Zylinderachse ergibt wie unter monokularen. Zu Beginn der Arbeit werden zunächst die
Grundlage zum Zyklofusionstest und der Aufbau des Testes erläutert. Zusätzlich wird in den
Methoden die Durchführung der Messung erläutert. In der Auswertung der Ergebnisse wurde
besonders auf die Zylinderachse und -stärke geachtet. Hier ergaben sich zwischen den beiden
Messverfahren leicht unterschiedliche Refraktionen. Im ersten Messdurchgang ergab sich für
die Differenz im sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,43 dpt und
im zweiten Messdurchgang von ±0,29 dpt um die mittlere Refraktion. Die beiden Messmethoden
unterscheiden sich daher nicht relevant voneinander. In 72% der Fälle führten beide
Messmethoden zur gleichen Visusstufe. Beim wiederholten Durchführen der Messung wurde in
77% der Fälle die gleiche Visusstufe erreicht. Des Weiteren ergab sich für die beiden Verfahren
eine ähnliche Reproduzierbarkeit. Bei der binokularen Messung ergab sich für die Differenz im
sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,37 dpt und bei der
monokularen Messung von ±0,39 dpt um die mittlere Abweichung. Um die Handhabung und
die Anwendbarkeit interpretieren zu können wurden zum einen die Dauer der Messungen mit
einander verglichen und zum anderen die Probanden nach der Messung zu ihrer persönlichen
Meinung befragt. Für die Messung am Zyklofusionstest ergab sich eine Prüfdauer von ca. 10
Minuten. 56% der Probanden empfanden die Beurteilbarkeit während der monokularen
Refraktion am einfachsten und angenehmsten. Für 15% war die Beurteilung am Zyklofusionstest
einfacher und die restlichen 29% konnten keinen Unterschied in der Beurteilung
feststellen. Anschließend wird in der Diskussion auf Komplikationen während der Messung
anhand von Einzelfällen eingegangen und mögliche Fehlerquellen werden aufgezeigt.
Abschließend ist festzustellen, dass der Zyklofusionstest eine neue Messmethode ist, die im
Wesentlichen die gleichen Ergebnisse und eine gleich gute Reproduzierbarkeit wie die
klassische monokulare Refraktion aufweist und in Zukunft mit in den Refraktionsablauf
integriert werden kann.
Die Bachelorthesis Vergleich zwischen Muster-Elektroretinogramm und multifokalem Elektroretinogramm bei Patienten mit Retinitis Pigmentosa untersucht, welches elektrophysiologisches Verfahren besser für die Verlaufskontrolle bei Patienten mit Retinitis Pigmentosa (RP) geeignet ist. Dafür wird ein direkter Vergleich zwischen dem multifokalen Elektroretinogramm (mfERG) und dem Muster-Elektroretinogramm (PERG) vorgenommen. Darüber hinaus wird die Korrelation zwischen diesen Untersuchungsmethoden bei Normalpersonen geprüft. Die Eignung des mfERGs und des PERGs zur Dokumentation der Krankheitsentwicklung wird in dieser Arbeit unter dem aktuellen Stand der Forschung beleuchtet. In der Studie wurden 9 Normalprobanden und 14 RP-Patienten mit den zu vergleichenden Methoden untersucht. Bei den Patienten wurden zusätzlich weitere Untersuchungen herangezogen, wie die Ableitung eines Ganzfeld-Elektroretinogramms (Ganzfeld-ERG) zur Sicherung der Diagnose, die Gesichtsfeldmessung mit dem Goldmann-Perimeter und die Fundusauto uoreszenz (FAF) mit dem Heidelberg Retina Angiograph. Beim multifokalen ERG wurde ein Reizmuster mit 61 Sechsecken verwendet. Die Ableitung des transienten und des steadystate Muster-ERGs erfolgte mit den Karogröÿen 0,8° und 18°. Bei allen elektrophysiologischen Ableitungen wurden die Empfehlungen der International Society for Clinical Electrophysiology of Vision (ISCEV) beachtet und DTL-Fadenelektroden genutzt. Für die statistische Auswertung kamen die Korrelations- und Regressionsanalyse sowie der McNemar-Test zum Einsatz. Die Korrelationsanalyse zwischen dem Muster-ERG und dem multifokalen ERG bei den Normalprobanden untersuchte, ob ein linearer Zusammenhang der beiden Verfahren besteht. Die Analyse lieferte lediglich eine mittlere Korrelation (r = 0,65 und r = 0,62), die jedoch nicht signikant belegt wurde (p = 0,056 und p = 0,077). Da bei der Mehrheit der Patienten die Erkrankung schon zu weit fortgeschritten war, konnte nur bei einigen Probanden eine signikante Antwort mit den elektrophysiologischen Methoden registriert werden. Nur bei 8 von 28 Augen der Patienten war eine signikante Ableitung mit dem PERG möglich. Beim mfERG waren es 5 von 28 Augen. Das Ganzfeld-ERG konnte nur bei einem Patienten registriert werden. Die Mehrheit der Patienten wies ein zentrales Restgesichtsfeld von unter 30 ° auf. Die FAF zeigte nur bei 4 Patienten noch erhaltene Bereiche. Der McNemar-Test konnte keinen Aufschluss darüber geben, welches Verfahren besser misst. Wie auch schon in anderen Studien bestätigt, sind das multifokale ERG und das Muster-ERG für die Anwendung bei der Dokumentation des Krankheitsverlaufs geeignet. Um endgültig herauszunden, welches Verfahren bessere Resultate liefert bei Patienten mit Retinitis Pigmentosa, sollten entsprechende Ausschlusskriterien gewählt werden und nach besseren Möglichkeiten für die Patientenrekrutierung gesucht werden. Dadurch kann eine zu geringe Anzahl an Patienten, bei denen noch Antworten ableitbar sind, vermieden werden. Der kombinierte Einsatz der beiden elektrophysiologischen Verfahren bietet bisher eine gute Lösung.
Die vorliegende Arbeit beschäftigt sich bezogen auf die Hörgeräteverifikation mit zwei Untersuchungsfragen. Ziel des ersten Versuches war die Ermittlung der Unterschiede zwischen den Zielkennlinien verschiedener Messsysteme. Dazu wurden die maximalen Differenzen der Zielwerte von drei simulierten Kundenfällen sowohl für die Präskription NAL-NL2 als auch für DSL v5.0 ermittelt. Darauf aufbauend wurde im zweiten Versuchsteil untersucht, ob sich die nach NAL-NL2 und DSL v5.0 softwaregenerierten, gemessenen Ausgangspegel der Hörgerätehersteller Phonak sowie Siemens und die gemittelten Zielwerte aus Versuch 1 unterscheiden. Hierbei wurden die gleichen simulierten Kunden wie in Versuch 1 gewählt und die Messung des Ausgangspegels am 2 cm³-Kuppler durchgeführt.
Es konnte festgestellt werden, dass sich die Zielkennlinien zwischen den Messsystemen für die Präskription NAL-NL2 im hohen Frequenzbereich und für DSL v5.0 im tiefen Frequenzbereich teilweise ummehr als 10 dB unterscheiden.
Die zweite Untersuchungsdurchführung hat gezeigt, dass die voringestellten Präskriptionen der Hörgerätehersteller (NAL-NL2 und DSL v5.0)und die vorberechneten Zielwerte teilweise stark differieren. Die größten Abweichungen sind für beide Präskriptionen und beide Hörgerätehersteller im hohen Frequenzbereich vorhanden. Wobei die Abweichungen für die Hörgeräte von Phonak im Durchschnitt < 10 dB und bei dem Hersteller Siemens > 10 dB sind.
Anhand dieser Ergebnisse können zwei Schlussfolgerungen festgehalten werden. Zum einen sollte dem Anpasser bewusst sein, dass die Vielzahl der wählbaren Präskriptionseinstellungen sowie die Komplexität der Messtechniken zu unterschiedlichen Zielkennlinien zwischen den Messsystemen führen kann. Daher ist es besonders wichtig, sich bei der Anpassung mittels Zielkennlinien mit der vorhandenen Messtechnik und den implementierten Präskriptionen auszukennen. Darüber hinaus sollte in Betracht gezogen werden die Hörgeräteanpassung mit
einer alternativen Anpassstrategie durchzuführen. Zum anderen wird deutlich, dass die Präskriptionen der Hörgerätehersteller nicht den Zielkennlinien entsprechen.
Um zu wissen, welche tatsächlichen Ausgangspegel am Trommelfell erzeugt werden, muss die Verifikation in Form der Kuppler- oder Sondenmikrofonmessung durchgeführt werden.
Das trockene Auge ist eine komplexe Erkrankung des vorderen Augenabschnitts. Es gibt eine Vielzahl von Ursachen, sowie eine Vielzahl an Therapiemöglichkeiten. Diese Arbeit befasst sich mit Benetzungsmitteln als Therapieform. Es existieren verschiedene Benetzungsmittel, die sowohl von Augenärzten, als auch von Optometristen und Optikern verabreicht werden. Es wird eine Übersicht über alle Benetzungsmittel erstellt, die in der Schweiz von Optometristen verabreicht werden können und ein Schema zur Anwendung je nach Diagnose entwickelt.
In der Hörakustikbranche ist in den letzten Jahren die offene Anpassung von Hörsystemen zum Trend geworden.
Die Standardschirmchen werden immer mehr zum Verkaufsschlager. Dabei stellt sich die Frage, ob offen angepasste Hörsysteme mit Schirmchen auch für den Endkunden die beste Wahl sind oder ob individuell gefertigte Folienotoplastiken bessere Ergebnisse, zum Beispiel im Sprachverstehen oder in der subjektiven Zufriedenheit, erzielen.
In der Studie wurden den Probanden offen angepasste Ex-Hörer Hörsysteme mit Standardschirmchen und mit individuell gefertigter Otoplastik jeweils für einen Testzeitraum angepasst. Um die beiden akustischen Ankopplungen zu vergleichen, wurde Augenmerk auf das Sprachverstehen, gemessen mit dem Oldenburger Satztest und dem Freiburger Sprachtest, gerichtet.
Die subjektiven Erfahrungen im Alltag wurden durch einen Fragebogen abgefragt.
Durch objektive Messungen, bestehend aus einer Insitu-Messung und der Messung der Verstärkung in der Messbox, wurden die Verstärkungsunterschiede der akustischen Ankopplung untersucht und mit den subjektiven Eindrücken der Probanden sowie mit den Ergebnissen der Sprachtests verglichen.
Die Ergebnisse zeigen, dass eine offene Versorgung mit Hörsystemen gekoppelt an eine individuelle Otoplastik tendenziell ein besseres Sprachverstehen erreichte. Die Zufriedenheit der Probanden unterschied sich dabei kaum. Ausschließlich der Tragekomfort wurde mit den Schirmchen tendenziell besser bewertet als mit einem individuellen Ohrstück.
Die Messungen in der Messbox und Insitu im Gehörgang zeigten, dass die Aus-wahl der akustischen Ankopplung in der Herstellersoftware großen Einfluss auf die Verstärkung hatte, um den Verlust des niederfrequenten Schalls teilweise zu kompensieren.
Das Ziel der vorliegenden Bachelorarbeit ist es, das Kaufverhalten der Vorgängergenerationen mit dem der Generationen Y und Z zu vergleichen und daraus resultierende Informationen über die Auswirkungen auf die Augenoptik in Deutschland zu erhalten, um den Markt besser zu verstehen und daraus zu lernen.
Dazu wurden zunächst das Kaufverhalten im Allgemeinen und die zugehörigen Segmente spezifiziert und alle Generationen mittels Literaturrecherche definiert und ihre Merkmale analysiert. Darauffolgend wurde das Kaufverhalten der einzelnen Generationen miteinander verglichen und die prägenden Merkmale der Generation Y und Z auf die Marktsituation in der Augenoptik übertragen.
Ziel und Zweck der Arbeit:
In dieser Arbeit wurden die Visusergebnisse der häufig verwendeten ETDRS- und Landoltring-Sehzeichentafeln mit denen des Freiburg Visual Acuity Test (FrACT) verglichen. Zusätzlich wird ein Hauptaugenmerk auf den Vergleich zweier Eingabemethoden für den Freiburg Visual Acuity Test gelegt, um ein mögliches Verbesserungspotenzial dieser aufzudecken. Bei den verwendeten Eingabemethoden handelte es sich um einen dreh- und fühlbaren Landolting (FrACTh) und die Eingabe mit einer modifizierten Zahlentastatur (FrACTk). Ziel dieser Studie war es, quantitative Aussagen zu folgenden Messgrößen zu ermitteln:
(i) die Übereinstimmung des FrACTk und FrACTh,
(ii) deren Reproduzierbarkeit,
(iii) die Übereinstimmung der Visusergebnisse aller verwendeter Tests und
(iv) deren Reproduzierbarkeit zu quantifizieren.
Material und Methoden:
Als Probanden nahmen an der Studie 25 augengesunde Studenten der Hochschule Aalen (19 – 28 Jahre) teil. Der Fernvisus jedes Probanden lag, mit oder ohne Korrektion, bei 0,2 oder höher. Ausgeschlossen waren Studenten der höheren Semester (ab zweiten Semester) des Studiengangs Augenoptik und Hörakustik. Die Messungen wurden monokular vorgenommen und erfolgten in randomisierten Abfolge der einzelnen Tests. Jeder Test wurde zweimal durchgeführt. „Forced choice“ und das 60% Kriterium wurden streng eingehalten. Es wurde kein Feedback in Bezug auf die Korrektheit der gegebenen Antwort gegeben.
Ergebnisse: Übereinstimmung der Sehschärfeergebnisse des FrACTk und FrACTh: Die Differenz der Mediane der beiden Tests nach dem ersten Testdurchlauf beträgt 0,074 logMAR (0,7 Zeilen) wobei FrACTh (-0,117 logMAR) bessere Resultate liefert. Dies ist im zweiten Durchlauf ebenfalls der Fall (FrACTh -0,112 logMAR) wobei die Differenz der Mediane hier geringer ist und noch 0,048 logMAR (0.5 Zeilen entspricht). Da die Differenzen der Mediane geringer sind als 0,3 logMAR (3 Zeilen), besteht statistisch kein signifikanter Unterschied zwischen den beiden Tests.
Übereinstimmung aller verwendeter Tests (ETDRS-, Landoltringtafeln, FrACTh und FrACTk ) in Bezug auf die Sehschärfewerte: Im Vergleich aller verwendeter Tests liefert im ersten Testdurchlauf auch hier der FrACTh mit -0,117 logMAR die besten Resultate. Mit -0,043 logMAR sind die Ergebnisse des FrACTk am schlechtesten und sind denen der Landoltringtafeln mit -0,048 logMAR sehr ähnlich. ETDRS ist um 0,2 Zeilen schlechter als FrACTh mit -0,097 logMAR. Im zweiten Testdurchlauf sind die Werte für den FrACTh und ETDRS annähernd gleich während die Ergebnisse der Landoltringta-feln um 0,5 Zeilen auf -0,097 logMAR steigen. Der FrACTk liefert hier mit -0,064 logMAR einen Anstieg um 0,2 Zeilen. Die Differenzen der Mediane sind kleiner als 0,3 logMAR (3 Zeilen).
Reproduzierbarkeit aller verwendeter Tests: Die Reproduzierbarkeit lag beim Vergleich der beiden Testdurchläufe für FrACTk und FrACT bei 0,012 logMAR bei ETDRS und Landoltringtafeln gab es mit 0 logMAR keinen Unterschied. Beim Vergleich der Tests untereinander (nur erster Testdurchlauf wurde verglichen) ist die Reproduzierbarkeit der FrACTk um 0,041 logMAR besser als die des FrACTh. Mit Werten für ICC <0.77 ist eine hohe Korrelation gegeben.
Schlussfolgerung:
Die Übereinstimmungen als auch die Reproduzierbarkeiten der einzelnen Tests war im Vergleich mit den aufgeführten Vergleichsstudien hoch. Der FrACTh erzielte sehr gute Visusergebnisse wohingegen der FrACTk in dieser Studie die schlechtesten Werte diesbezüglich aufwies. Fortführend ist eine Weiterentwicklung der Eingabemethoden für den FrACT angeraten.
Hintergrund: Die Sehschärfebestimmung ist die am häufigsten geprüfte Sehfunktion. Landoltringe und Buchstaben werden oftmals als Sehzeichen zur Sehschärfebestimmung verwendet. In dieser Studie werden vier Sehtestmetho-den miteinander verglichen, welche derartige Optotypen darbieten: Der Freiburg Visual Acuity Test (FrACT), unter Verwendung eines Nummernblocks (FrACTk), bzw. eines rotierbaren, haptischen Landoltrings (FrACTh) als Eingabegeräte, die Tübingen Landolt Chart, auf welcher Landoltringe nach den Vorgaben der ISO 8596 sowie DIN 58220 Teil 3 dargeboten werden und ETDRS-Sehzeichentafeln. Ziele der Studie waren es (i) den Unterschied zwischen der subjektiven Bewertung der Testmethoden durch Probanden selbst, sowie die Beurteilung des Zurechtkommens der einzelnen Versuchspersonen durch den Untersucher, unter Verwendung von visuellen Analogskalen (VAS) herauszufinden und hinsichtlich der Testdauer (ii) die Ermittlung der Inter-Test Reliabilität zwischen den Methoden und (iii) deren Test-Retest Reliabilität zu vergleichen. Es wird besonders auf die Untersuchungsergebnisse von FrACTk und FrACTh eingegangen.
Probanden und Methodik: Für die explorative Studie wurden 24 augengesun-de, erwachsene Studenten der Hochschule Aalen (davon 14 männlich und 10 weiblich) mit einer Sehschärfe von ≥ 0,2 (4/20) als Probanden untersucht. Sämtliche Studierende verschiedener Fachrichtungen waren mit den Methoden der Visusbestimmung bislang nicht vertraut. Dabei wurde nach Zufallsprinzip die monokulare Sehschärfe des Führungs- oder nicht führenden Auges bestimmt. Die vier Testmethoden wurden jeweils zweimal in einer kontrollierten, randomisierten Reihenfolge, welche vor Studienbeginn in einer Permutationskette festgelegt wurde und unter Gebrauch der Forced-Choice-Strategie durchgeführt.
Ergebnisse: Subjektive Einschätzung: FrACTk wurde von Probanden und Untersuchern gegenüber FrACTh präferiert (p<0,001). Der ETDRS-Test und FrACTk wurden gegenüber den Landolt-Tafeln und FrACTh bevorzugt. Testdauer: Die Durchführung des FrACTh dauerte durchschnittlich 1,5-mal länger als FrACTk (p<0,001). FrACTk und ETDRS-Test waren am schnellsten durchführbar mit einem Median im ersten Testdurchgang von 48,2 und 48,7 Sekunden (p>0,05). FrACTh und der Landoltringtafel-Test nahmen 68,2 Sekunden und 96,1 Sekunden in Anspruch (Median erster Testdurchgang, p>0,05). Alle Sehtests, welche als Optotype den Landoltring verwendeten, wiesen einen signifikant schnelleren zweiten Testdurchgang auf (p<0,05). Die zwei Testdurchgänge des ETDRS-Tests dauerten nahezu gleich lang (p>0,05).
Schlussfolgerung: Die Durchführung des FrACT ging mit dem Nummernblock schneller als mit dem haptischen Eingabegerät und wurde von den Probanden und Untersuchern bevorzugt. ETDRS-Tests und FrACTk waren hinsichtlich der absoluten Testzeiten kürzer als die Ausführung des FrACTh und des Landoltringtafel-Tests. Die schnellsten Tests wurden auch von Probanden und Untersuchern am besten bewertet.
Die vorliegende Arbeit hat sich zum Ziel gesetzt, subjektive Refraktionen im Hellen und im Dunkeln, welche beide mithilfe der modifizierten Fan and Block Methode durchgeführt wurden, miteinander zu vergleichen. Überdies soll die Reproduzierbarkeit der Messgenauigkeit der subjektiven Refraktionen sowohl für den photopischen als auch für den mesopischen Bereich überprüft werden. Die vorliegende Arbeit entstand in Zusammenarbeit mit Nicole Zeller, deren Bachelorarbeit sich schwerpunktmäßig dem Vergleich der subjektiven und objektiven Refraktionen mittels Wellenfrontanalyse widmet. Im Rahmen der Untersuchung wurden 35 Probanden objektiv und subjektiv unter photopischen und mesopischen Bedingungen refraktioniert. Den Grundlagen der Refraktionen, im speziellen der Erläuterung der modifizierten Fan and Block Methode, und deren Durchführung widmet sich der Beginn der Arbeit. Im weiteren Verlauf liegt das Hauptaugenmerk auf der Darstellung und Erläuterung der Refraktionen, welche mittels der Differenz der sphärischen Äquivalente und der Power-Vektor Analyse statistisch erfasst und ausgewertet wurden. Hierdurch gelangte die vorliegende Untersuchung zu dem Ergebnis, dass in der Dämmerung tendenziell eine geringe Änderung (im Bereich bis -0,5 Dioptrien) der subjektiven Refraktion in Richtung Myopie stattfindet. Überdies konnte festgestellt werden, dass mit zunehmender Zylinderstärke die Refraktionsänderungen größer und häufiger werden. Mit Blick auf den objektiven Vergleich der Refraktionen konnte belegt werden, dass in der Dämmerung tendenziell eine geringe Verschiebung (im Bereich bis +0,5 Dioptrien) in Richtung Hyperopie festzustellen ist. Bei der Auswertung mittels der Power-Vektor Analyse konnte hierbei ermittelt werden, dass im Vergleich zum subjektiven Vergleich der Refraktionen die Streuung der Messwerte geringer ist, was darauf schließen lässt, dass die objektiven Refraktionsänderungen kleiner als die subjektiven sind. Abschließend gelangt die Arbeit zu der Empfehlung, dass es aufgrund der nachweisbaren Refraktionsänderungen sinnvoll ist, individuell subjektiv zu überprüfen, ob und in welchem Ausmaß diese abhängig von den Beleuchtungsbedingungen vorliegen, um eine kunden- und situationsgerechte Versorgung zu gewährleisten.
Seit einiger Zeit ist nun die 3D-Refraktion auf dem Markt und gewinnt seitdem immer mehr an Zuwachs.
Neben der Firma Ipro, brachten auch die Firmen Deutschen Augenoptik AG und OCULUS eigene 3D-Refraktionssysteme auf den Markt. Größter Unterschied zur bisherigen 2D-Refraktion ist es, dass die 3D-Refraktion stets unter binokularen Bedingungen durchgeführt wird. Dabei soll die 3D-Refraktion neben
genaueren Messergebnissen, dem Kunden durch Landschaftsbilder ein Erlebnis bieten.
In der Bachelorarbeit „Vorstellung und Vergleich der 3D-Refraktionssysteme: PasKal 3D, PolaSkop 3D und Vissard 3D“ ging es darum die drei 3D-Refraktionssysteme
vorzustellen und sowohl objektiv als auch subjektiv miteinander zu vergleichen.
Dafür wurde eine Befragung bei 76 Augenoptikern in Deutschland durchgeführt. Anhand der Ergebnisse der Umfrage wird ermittelt, inwieweit die Augenoptiker mit ihrem 3D-Refraktionssystem zufrieden sind und welche Erfahrungen gemacht wurden. Zudem wird ein Vergleich zwischen 2D-Refraktion und 3D-Refraktion, sowie den drei 3D-Refraktionssystemen gezogen.
Die Befragung zeigt, dass im Allgemeinen alle Augenoptiker mit ihrem 3D-Refraktionssystem zufrieden sind. Die drei 3D-Refraktionssysteme schneiden bei den meisten Punkten ähnlich gut ab.
Im Vergleich zur 2D-Refraktion sind sich die Befragten einig, dass die 3D-Refraktion nicht unbedingt eine schnellere Refraktion ermöglicht. Ebenso verzeichneten die Augenoptiker nicht weniger Reklamationen bezüglich Stärkenunverträglichkeiten.
Die Erfahrungen der Augenoptiker mit den Kunden ergaben, dass die Kunden bei der Mehrheit positiv auf die 3D-Refraktion reagierten.
Validierung des SNR mit Hilfe des OlSa in drei Lautstärken mit zwei verschiedenen Hörgeräteklassen
(2015)
Da Unterschiede zwischen Low-End- und High-End-Hörsystemen nicht mehr in Ruhe nachgewiesen werden können, wurde in dieser Studie der Unterschied zwischen den beiden Hörsystemen überprüft. In bisherigen Studien konnte nur
eine Verbesserung des SNR durch eine Richtmikrofonwirkung nachgewiesen werden.
Um die Vorteile der weiteren Features und der höheren Kanalanzahl bei den High-End-Hörsystemen nachzuweisen, wurden in dieser Studie das Störgeräusch und das Sprachsignalaus der gleichen Richtung angeboten. Den Probandinnen und Probanden wurden jeweils ein Low-End- und ein High-End-Hörsystem nach NAL-NL2 angepasst. Dabei wurden sie in drei verschiedene Schwerhörigkeitsgrade eingeteilt und mit dem Oldenburger Satztest der SNR bei drei verschiedenen Störgeräuschlautstärken bestimmt.
Verglichen wurden sowohl der Unterschied in den einzelnen Gruppen von Schwerhörigkeitsgraden als auch die Verbesserung im Gegensatz zum unversorgten SNR. Es besteht tendenziell ein Unterschied zwischen den beiden Hörsystemen. In nahezu allen Störgeräuschlautstärken und allen Schwerhörigkeitsgraden wurde eine Verbesserung des SNR mit den High-End-Hörsystemen erreicht.
Der Vorteil der High-End-Hörsysteme wird mit lauterem Störgeräusch größer, so dass die Schwerhörigen vor allem in lauten Situationen von den Hörsystemen profitieren können.
Die Verbesserung des SNR mit den Hörsystemen gegenüber keiner Versorgung liegt bei den mittel- und hochgradig Schwerhörigen weit über der von der HilfsM-RL geforderten 2 dB.
Der Vorteil der High-End-Hörsysteme muss noch in weiteren Studien untersucht werden um einen signifikanten Unterschied zwischen den beiden Hörsystemen nachzuweisen, der in dieser Studie schon tendenziell nachgewiesen werden konnte.