Optik und Mechatronik
Refine
Year of publication
Document Type
- Conference Proceeding (51)
- Article (35)
- Master's Thesis (8)
- Bachelor Thesis (6)
- Book (2)
- Patent (2)
- Doctoral Thesis (1)
- Report (1)
Language
- English (106) (remove)
Keywords
- Myopia (2)
- Blinking (1)
- Blinzeln (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- Defocus (1)
- Diffusion (1)
- Edge Detection (1)
- Eye Tracking, Vigilanz, Aufmerksamkeit, visuelle Exploration, Perimetrie (1)
- Eye tracking (1)
- Fixation (1)
- Kantendetektion (1)
- Laser sources (1)
- Lens design (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Optical components (1)
- Optical design (1)
- Optical elements (1)
- Reflector design (1)
- Scanpath (1)
- Trockenes Auge (1)
- Tränenfilm (1)
- Virtual reality (1)
- Virtuelle Realität (1)
- Visual search (1)
- albinism (1)
- customized (1)
- dry eye (1)
- eye tracking, vigilance, attention, cognitive workload, visual exploration, perimetry (1)
- genes (1)
- low vision (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- myopia management (1)
- peripheral myopic defocus (1)
- repeatability (1)
- soft multifocal contact lens (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- tear film (1)
- two-rod test (1)
- vision therapy (1)
Institute
- Optik und Mechatronik (106)
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Ophthalmic lenses are ideally measured in accordance with the center of rotation of the eye. Therefore a measuring device was constructed due to this principle to measure lenses with a focimeter. In this work that measuring device was validated. Lenses of ± 4 dpt in spherical and aspherical design were measured across a field of 9x9 measuring points being at 5° distance from each other. This corresponds to a field of view of 40°. The measurement points in x- and y- direction were theoretically calculated to validate the measurement results. Regarding angles of incidence up to 20° it was supposed that the main optical aberration depends on a change in the sagittal and tangential sphere powers which is also defined as astigmatism. Therefore the calculation presents the tangential and sagittal oblique sphere powers depending on the different angles of the line of vision. On average the measurement results and the calculated data of the spherical designed lenses coincide quite good (correlation at 0,98), the systematic deviation of both values on average is 0.01 dpt and the random error (standard deviation) amounts 0.03 dpt on average. The minimum deviation is -0.06 dpt and the maximum is 0.09 dpt. Common focimeters have a measuring inaccuracy of up to 0.06 dpt (Diepes, Blendowske 2002). Therefore the quality of the measured data should be reliable. The aspherical designed lenses were compared to the spherical designed lenses. With increased angles of incidence the astigmatism of the aspherical lenses leads to lower values than the astigmatism of the spherical lenses
Identification and quantitative segmentation of individual blood vessels in mice visualized with preclinical imaging techniques is a tedious, manual or semiautomated task that can require weeks of reviewing hundreds of levels of individual data sets. Preclinical imaging, such as micro-magnetic resonance imaging (μMRI) can produce tomographic datasets of murine vasculature across length scales and organs, which is of outmost importance to study tumor progression, angiogenesis, or vascular risk factors for diseases such as Alzheimer’s. Training a neural network capable of accurate segmentation results requires a sufficiently large amount of labelled data, which takes a long time to compile. Recently, several reasonably automated approaches have emerged in the preclinical context but still require significant manual input and are less accurate than the deep learning approach presented in this paper—quantified by the Dice score. In this work, the implementation of a shallow, three-dimensional U-Net architecture for the segmentation of vessels in murine brains is presented, which is (1) open-source, (2) can be achieved with a small dataset (in this work only 8 μMRI imaging stacks of mouse brains were available), and (3) requires only a small subset of labelled training data. The presented model is evaluated together with two post-processing methodologies using a cross-validation, which results in an average Dice score of 61.34% in its best setup. The results show, that the methodology is able to detect blood vessels faster and more reliably compared to state-of-the-art vesselness filters with an average Dice score of 43.88% for the used dataset.
The direct ophthalmoscope is a retinal screening tool that has been in existence and development for more than 150 years, yet, the rapid influence of technological evolution in screening tools, has left the direct ophthalmoscope untouched. The main purpose of this master thesis is to determine if the direct ophthalmoscope has reached its maximum potential of development and, additionally, to determine if a further development, including a more electronic input, would be feasible.
Purpose: The aim is to be able to advise patients on the choice of sports and exercises regarding the effects on the intraocular pressure.
Methods: The search engines Google Scholar and PubMed were used to search for suitable studies. The studies were summarized, and the most important data were collected in one table for each study. The effect on the IOP was extracted or, if not given in the article, calculated by the difference of means of the IOP after or during exercise, and the baseline IOP before, whenever these values were available.
Findings: A total of 47 studies out of the years 1990 to 2020 that investigated the influence on the IOP of the most popular sports actively practiced in Germany were reviewed and summarized: twelve for running, sixteen for fitness/ weight training, one for swimming/diving, twelve for cycling, four for hiking, and two for yoga.
Conclusions: Throughout all studies and sports it was seen that physical fitness stabilized the IOP. Higher
intensity of exercise led to higher fluctuations of the IOP. Moderate endurance training keeps the IOP fluctuations low and may lead to a lower baseline IOP if practiced on a regular base. Fitness and weight training lead to fluctuations of the IOP in a pronounced manner when performed at moderate and high intensity. Therefore, only a moderate training can be recommended if there is need to keep the IOP stable. Isometric exercise is not recommended as it provokes a rise of the IOP even when performed with light loads. The Valsalva Maneuver should always be avoided as it leads to additional fluctuations of the IOP. Also, the IOP behaved more stable during resistance training when higher fitness was present.