Optik und Mechatronik
Refine
Year of publication
Document Type
- Bachelor Thesis (108)
- Conference Proceeding (70)
- Article (60)
- Patent (21)
- Master's Thesis (20)
- Book (8)
- Part of a Book (4)
- Report (4)
- Doctoral Thesis (2)
Language
- German (190)
- English (106)
- Multiple languages (1)
Keywords
- Abschlussarbeit (6)
- Augenoptik (5)
- Bachelorarbeit A/H (4)
- Leitfaden (4)
- Myopieprogression (3)
- Studie (3)
- Digitalisierung (2)
- FrACT (2)
- Gleitsichtgläser (2)
- Hörgerät (2)
- Hörsystem (2)
- Kinder (2)
- Kontaktlinse (2)
- Kreuzzylinder (2)
- Landoltring (2)
- Myopia (2)
- Pentacam® (2)
- Scheimpflug technology (2)
- Scheimpflugkamera (2)
- Studium (2)
- Umfrage (2)
- Visus (2)
- limbal sclera contour (2)
- vorderer Augenabschnitt (2)
- 3D-Druck (1)
- 3D-Refraktion (1)
- 610 Medical sciences (1)
- AVATAR, Sehschärfenbestimmung, Computer (1)
- Aalener Schnell Satztest (1)
- Aberrometer (1)
- Ablaufplan (1)
- Absolventen (1)
- Absolventenbefragung (1)
- Alvarezlinsen, Focusspec-Brille, Scheitelbrechwertmessung, Augendrehpunkt (1)
- App (1)
- Applikation (1)
- Atropin (1)
- Auditive und taktile Stimulation (1)
- Augenlänge (1)
- Augenmodell (1)
- Augenoptik-Branche (1)
- Augenoptikgeschäft (1)
- Augenoptikmarkt (1)
- Ausbildung (1)
- Bachelorarbeit A (1)
- Befragung (1)
- Behandlung, Kontaktlinsen, Presbyopie (1)
- Belastungsstörungen (1)
- Beratungsgespräch (1)
- Blinking (1)
- Blinzeln (1)
- Brillenfassung (1)
- Brillenfassung, UV-Durchlässigkeit (1)
- Brillenglaszentrierung (1)
- Choroidal thickness (1)
- Comparison metrics (1)
- DNEye ® Scanner (1)
- Deflektometrie (1)
- Defocus (1)
- Dienstleistungsangebot (1)
- Diffusion (1)
- Dynamische Preise (1)
- EMDR-Behandlungen (1)
- ETDRS (1)
- ETDRS-Tafeln (1)
- Edge Detection (1)
- Erblindung (1)
- Ethik (1)
- Eye Tracking, Vigilanz, Aufmerksamkeit, visuelle Exploration, Perimetrie (1)
- Eye tracking (1)
- Fixation (1)
- Gebrauchsstellung (1)
- Geschäftsmodell (1)
- Gleitsichtbrille (1)
- Grenzfrequenz (1)
- High-End-Hörsystem (1)
- Horn (1)
- Hörgerätverifikation (1)
- Hörqualität (1)
- Hörsysteme (1)
- Hörtraining (1)
- IOL Master 500 (1)
- Informationsbroschüre (1)
- Inter-Test Reliabilität (1)
- Internationalisierung (1)
- Jugendliche (1)
- KI (1)
- Kameramessung (1)
- Kampimetrie (1)
- Kantendetektion (1)
- Kind (1)
- Kommunikationstraining (1)
- Kontaktlinsen (1)
- Kontaktlinsen-Service-System (1)
- Kontaktlinsensprechstunde (1)
- Kostenakzeptanz (1)
- Kreislaufwirtschaft (1)
- Kreuzzylinderabgleich (1)
- Kundengruppen (1)
- Kunststoff (1)
- LEA Symbole (1)
- Laser sources (1)
- Lehrmethoden (1)
- Lens design (1)
- Lernsoftware (1)
- Lernvideo, Verkaufsgespräch (1)
- Lernvideo, e-Learning, Leitfaden (1)
- Leuchtdichte Homogenität (1)
- Leuchtdichte, Radiospektrometer, Kalibrierung, Spiegelreflexkamera (1)
- Leuchtdichteverteilung (1)
- Lions Club (1)
- Literaturübersicht (1)
- Low-End-Hörsystem (1)
- Marokko (1)
- Masterarbeit AO (1)
- Materialeigenschaften (1)
- Medicine (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Messmethode (1)
- Messsystem (1)
- Messtechnik (1)
- Multifocal contact lenses (1)
- Multisensorische Integration (1)
- Musikinstrument (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- Myopie-Management (1)
- Myopiekontrolle (1)
- Myopiemanagement (1)
- Nachhaltigkeit (1)
- Ohrmodell (1)
- Omnichannel (1)
- Onlineportal (1)
- Optical Engineering (1)
- Optical components (1)
- Optical design (1)
- Optical elements (1)
- Optometrie (1)
- Optometrist (1)
- Optotypen (1)
- Orthokeratologie (1)
- Perimetrie (1)
- Photopisches Sehen (1)
- Plusoptix (1)
- Preisfairness (1)
- Primary Eye Care Provider (1)
- Psychophysik (1)
- Qualifizierung (1)
- RCS (1)
- Reflector design (1)
- Refraktion (1)
- Refraktionsbestimmung (1)
- Retest-Reliabilität (1)
- Revenue-Management (1)
- Revenue-Marketing (1)
- Risikoanalyse (1)
- SNR-Verhältnis (1)
- Satztest (1)
- Scanpath (1)
- Schmalbandsignal (1)
- Schule (1)
- Schüler (1)
- Screening (1)
- Sehilfen (1)
- Sehschärfe (1)
- Situationserkennung (1)
- Six Sigma (1)
- Sphärisches Äquivalent (1)
- Sri Lanka (1)
- Strategie, Unternehmensführung, AMVO, VaKE (1)
- Streifenprojektion (1)
- Streifenprojektionsgerät (1)
- Studiengang Augenoptik (1)
- Störgeräusch (1)
- Tablet (1)
- Technikfolgenabschätzung (1)
- Tieftonkompression (1)
- Tochter, Familienunternehmen, Nachfolge (1)
- Tolerance of blur, PAL`s, Astigmatism, Blurtest, Pretest (1)
- Traumatische Erinnerungen (1)
- Trockenes Auge (1)
- Tränenfilm (1)
- Unschärfetoleranz , Gleitsichtgläser, Astigmatismus , Blurtest, Pretest (1)
- Unverträglichkeit (1)
- Unzufriedenheit (1)
- Versorgungskapazität (1)
- Verzeichnung (1)
- Virtual reality (1)
- Virtuelle Realität (1)
- Visual acuity (1)
- Visual search (1)
- Visusbestimmung bei Kindern (1)
- Vorderkammertiefe (1)
- Weblog (1)
- Webportal (1)
- Webseite (1)
- Weiterbildung (1)
- Wiki (1)
- Workflow (1)
- Zufriedenheitsmessung (1)
- Zyklofusionstest (1)
- advanced training (1)
- albinism (1)
- artificial consciousness (1)
- auditive Wahrnehmung (1)
- augenoptischer Betrieb (1)
- automatical telephone audiometry, hearing aid fitting (1)
- automatisierter Telefonhörtest, Hörgeräteanpassung (1)
- berufliche Perspektiven (1)
- binaural synchronization (1)
- binaurale Synchronisation (1)
- blindness (1)
- care capacity (1)
- classification (1)
- customized (1)
- data logging (1)
- daughter, family enterprise, succession (1)
- demografischer Wandel (1)
- demographic change (1)
- digitales Endgerät (1)
- digitization (1)
- dry eye (1)
- erfolgreiches Geschäftsmodell, optometrische Dienstleistungen, Wettbewerb (1)
- eye tracking, vigilance, attention, cognitive workload, visual exploration, perimetry (1)
- genes (1)
- i.Profiler (1)
- individueller Inset (1)
- internationale Schwerhörigenhilfe (1)
- isochroner Rythmus (1)
- learning videos, e-learning, guideline (1)
- low vision (1)
- luminance distribution (1)
- luminance homogeneity (1)
- luminance, radio spectrometer, calibration, reflex-camera (1)
- measurement of the visual acuity in children (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- medical treatment, contact lens, presbyopia (1)
- melanin (1)
- monokulare Refraktionsbestimmung (1)
- multistabiler Rythmus (1)
- myopia management (1)
- optometric and optical companies (1)
- optometrische Dienstleistungen (1)
- peripheral myopic defocus (1)
- plusoptiX Binokular Autorefraktometer (1)
- proaktive Ansprache (1)
- psychophysics (1)
- qualification (1)
- repeatability (1)
- schwerhörige Erwachsene (1)
- schwerhörige Kinder (1)
- shortage of doctors (1)
- soft multifocal contact lens (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- strategy, management, AMVO, VaKE (1)
- successful business-model, optometrical service, competition (1)
- sustainability (1)
- tablet-basierte Applikation (1)
- tear film (1)
- two-rod test (1)
- vision therapy (1)
- visual acuity (1)
- weiche Kontaktlinsen (1)
- Ärztemangel (1)
Institute
- Optik und Mechatronik (297)
In dieser Bachelorarbeit geht es darum, ein System zu bauen, mit dem die Augenbewegungen gemessen werden können bei Verwendung von GS und im Vergleich dazu bei Verwendung von Einstärkengläsern (ES). Das System soll eine natürliche Lesesituation simulieren. Es sollen die Grenzen herausgefunden werden, wo der astigmatische Fehler beim Tragen von GS gerade noch akzeptiert wird. Hierfür soll keine Augentrackingbrille verwendet werden, sondern aufgrund der Kopfbewegungen (KB) und dem Wissen wo der Proband hinschaut, die Augenbewegungen (AB) berechnet werden.
Ziel:
Das Ziel dieser Arbeit ist es einen allgemeingültigen Leitfaden für die Erstversorgung der Presbyopie mit Kontaktlinsen zu entwickeln. Der Leitfaden soll Anpassern und Berufseinsteigern als unterstützendes Hilfsmittel dienen. Der Fokus liegt darauf, alle nötigen Faktoren in eine übersichtliche Form zu bringen, sodass bei der Anpassung eine systematische Reihenfolge entsteht und nichts übergangen wird. Dabei beziehen sich alle notwendigen Aspekte auf das reguläre Auge.
Material und Methoden:
Zur Entwicklung des Leitfadens dienen sowohl eine orientierende Fragebogen-Untersuchung von erfahrenen Anpassern zur ihrer Anpass-Philosophie als auch eine retrospektive Analyse der Anpass-Einzelschritte von 40 durch die Müller-Welt Contactlinsen GmbH versorgten Kunden. Zur Erläuterung der praktischen Anwendung des erarbeiteten Leitfadens werden am Ende dieser Arbeit 6 typische Versorgungssituationen bei Presbyopie detailliert dargestellt.
Ergebnisse:
Bei der Kontaktlinsenanpassung presbyoper Kunden ist eine ausführliche Anamnese die Basis für eine erfolgreiche Versorgung. Dies erreicht der Anpasser durch eine gute Kommunikation. Damit hierbei nichts versehentlich übergangen wird, bedarf es einer systematischen Vorgehensweise. Der im Rahmen dieser Arbeit entwickelte Leitfaden dient dafür als wichtiges Hilfsmittel. Er gliedert sich in vier große Teilbereiche:
1. Kontaktlinsenerfahrungen: Wenn der Kunde bereits Kontaktlinsenträger ist wird das Material übernommen, nach dem Motto „Never change a winning team“. Bei auftretenden Problemen werden diese zunächst beseitigt, bevor eine Presbyopieversorgung durchgeführt wird. Erst dann wird das Pres-byopiesystem ausgewählt. Trägt der Kunde bisher keine Kontaktlinsen, wird bei der Anpassung zunächst eine mehrwöchige Standardversorgung ohne Korrektion der Presbyopie durchgeführt (Gewöhnung des Kunden an Kontaktlinsentragen, Rückgang der anfänglichen Reizsekretion usw.). Nach einer erfolgreichen Eingewöhnungszeit wird dann erst im zweiten Schritt das Presbyopiesystem angepasst, das bereits im Voraus anhand der nachfolgenden drei Kriterien ermittelt wird.
2. Kundenwunsch: Er gibt Aufschluss über Anwendungsbereiche und Tragerhythmus sowie situative Umgebungsbedingungen und Sehanforderungen. Dadurch ergibt sich sowohl das Presbyopiesystem als auch das Kontaktlinsenmaterial.
3. Anatomischen Voraussetzungen: Sie liefern ebenfalls Ergebnisse bezüglich des Systems und Materials. Unter anderem beeinflusst die Lidposition die Systemwahl und trägt somit überwiegend zu dem Erfolg der Versorgung bei.
4. Art der Fehlsichtigkeit: Hier entscheidet hauptsächlich die Ausprägung der Addition über die Presbyopieversorgung.
Zu jedem der zuvor genannten vier Aspekte wird in dieser Arbeit jeweils ein gesondertes Flussdiagramm erarbeitet, womit der Anpasser gemeinsam mit dem Kunden das optimale Presbyopie-System individuell auswählen kann. Basierend auf diesen Flussdiagrammen wird für den praktischen Einsatz und eine erleichterte Dokumentation ein spezieller Formular- und Dokumentationsbogen erstellt. Abschließend wird in dieser Arbeit die praktische Anwendung des Leitfadens anhand von sechs typischen Fallbeispielen detailliert erläutert.
Schlussfolgerung:
Der Anpassleitfaden ist für die Presbyopieversorgung ein sinnvolles Hilfsmittel bei der Anamnese und Untersuchung sowie der zielgerichteten Auswahl des jeweiligen Presbyopiesystems.
Eine Weiterentwicklung des Leitfadens könnte in digitaler Form (z.B. App) erfolgen, so wird die Vorgehensweise noch benutzerfreundlicher. Es zeigt dem Kunden die innovativen und professionellen Methoden seines Augenoptikers auf. Das fördert die Kundenbindung und trägt somit zum wirtschaftlichen Erfolg durch die Presbyopie-versorgung mit Kontaktlinsen bei.
Purpose: Usually, a theory of attention upon gazed-at locations is applied. More parameters than gaze location can be derived to improve the theory of attention allocation. The aim of this study was to identify parameters related to eye tracking, that are suitable indicators of attention.
Methods: Binocular eye tracking data was collected with the Eye Tribe tracking system (The Eye Tribe Aps, Copenhagen, Denmark) for the task of visual exploration of the painting “Unexpected Visitors” by Ilya Repin. 20 subjects (valid data: 19/20) had to look at this painting for about two and a half minutes in order to generate fatigue and inattention. In a second step, suitable parameters of attention were transferred to a data set (8 subjects, valid data: 6/8) on a perimetric task executed with the OCTOPUS 900 perimeter (Haag-Streit, Köniz, Switzerland). Monocular parameters could be applied on the perimetric task, the error rate (false positive and false negative catch trials, 5 % each) were taken as additional parameter.
Results: For the image viewing task, the only parameter showing significance was the average level (a10) of fatigue waves (p = 0.00024, ANOVA, ∆ = -0.8316 px). Blink duration (∆ =-270.4 ms), pupil variability (∆ = -0.17868), saccade length (∆ =-0.3135 px) and fixation duration (∆ = 186.5 ms) did not change significantly, but showed relevant trends by differences ∆ of their median between the first and last tenth of the recording time. Blink rate and the Index of Cognitive Activity (ICA) did neither show significant changes nor relevant trends. Vergence accuracy failed to indicate fatigue due to variability between subjects and comparatively small effect size. For the perimetric data, in 3 of 6 subjects fatigue waves over a limited time window could be observed. Only for one subject, a relevant increase in false negative responses to catch trials (50 percentage points) could be observed.
Conclusion: Pupil diameter variability, saccade length, fixation duration and fatigue waves were the parameters indicating fatigue. Only the latter parameter has the potential to be applied to perimetric data.
Zweck: Das Ziel dieser Studie ist es die Wahrnehmung und Akzeptanz von Unschärfe beim seitlichen Blick durch ein Gleitsichtglas zu untersuchen. Mit dem Blurtest sollte eine geeignete Methode zur Messung von Sehbereichsbreiten bei Gleitsichtgläsern entwickelt und verifiziert werden.
Material/Methoden: Die horizontalen Sehbereichsbreiten von vier Gleitsichtgläsern unterschiedlicher Progressionskanalbreite (2, 3, 4 und 5 mm) und linearem Wirkungsanstieg sollten bei einem Beobachtungsabstand von 40 cm für drei Unschärfekriterien gemessen werden. Die Grenzen für bemerkbare, tolerierbare und unakzeptable Unschärfe werden für einen am Bildschirm dargebotenen sinnfreien Text in Schriftgrad 9 pt (Visus = 0,4) links und rechts des monokularen Blickfelds markiert. Zusätzlich sollte in einem Vortest (Pretest) nach diesen Kriterien verschwommener, gedruckter Text beurteilt werden.
Ergebnisse: Die Grenzen für eben bemerkbare, tolerierbare und unakzeptable Unschärfe liegen bei einem Astigmatismus in Gebrauchsstellung von 0,70 ±0,3 dpt, 1,37 ±0,50 dpt und 2,06 ±0,74 dpt bei einem natürlichen Pupillendurchmesser von durchschnittlich 3,37 mm. In 40 % der Fälle unterscheiden sich die Grenzen für Unschärfe innerhalb eines Probanden nicht signifikant. Es besteht ein Zusammenhang zwischen der Toleranzbereitschaft unscharfe Texte in Alltagssituationen zu lesen und der Beurteilung von modifiziertem, gedrucktem Text.
Fazit: Die markierten Sehbereichsbreiten korrelieren mit dem horizontalen Anstieg des unerwünschten Astigmatismus, lassen sich bei Wiederholungsmessungen am Blurtest jedoch nicht auf ≤ 2° Schwankungsbreite reproduzierbar nachweisen. Die Definition, Wahrnehmung und Toleranz von Unschärfe in verschiedenen Alltagssituationen hängen von individuellen Erfahrungswerten und gesetzten Anspruch an Seh- bzw. Leseleistungen ab.
Ophthalmic lenses are ideally measured in accordance with the center of rotation of the eye. Therefore a measuring device was constructed due to this principle to measure lenses with a focimeter. In this work that measuring device was validated. Lenses of ± 4 dpt in spherical and aspherical design were measured across a field of 9x9 measuring points being at 5° distance from each other. This corresponds to a field of view of 40°. The measurement points in x- and y- direction were theoretically calculated to validate the measurement results. Regarding angles of incidence up to 20° it was supposed that the main optical aberration depends on a change in the sagittal and tangential sphere powers which is also defined as astigmatism. Therefore the calculation presents the tangential and sagittal oblique sphere powers depending on the different angles of the line of vision. On average the measurement results and the calculated data of the spherical designed lenses coincide quite good (correlation at 0,98), the systematic deviation of both values on average is 0.01 dpt and the random error (standard deviation) amounts 0.03 dpt on average. The minimum deviation is -0.06 dpt and the maximum is 0.09 dpt. Common focimeters have a measuring inaccuracy of up to 0.06 dpt (Diepes, Blendowske 2002). Therefore the quality of the measured data should be reliable. The aspherical designed lenses were compared to the spherical designed lenses. With increased angles of incidence the astigmatism of the aspherical lenses leads to lower values than the astigmatism of the spherical lenses
Die Stiftung „Focus on Vision“ hat nach dem Prinzip der Alvarezlinsen Sehhilfen mit variabler Stärke entwickelt – die Focusspec-Brillen. Diese werden vor allem in Entwicklungsländern eingesetzt, um die Bevölkerung schnell und effektiv mit einer Korrektion zu versorgen. Es gibt zwei verschiedene Ausführungen, eine mit einstellbaren positiven Brechwerten (von 0,5 dpt bis 4,5 dpt) und eine mit einstellbaren negativen Brechwerten (von -1,0 dpt bis -5,0 dpt).
In dieser Arbeit wurden diese Sehhilfen mit einem Scheitelbrechwertmesser vermessen und die auftretenden Aberrationen genauer betrachtet.
Da in der realen Gebrauchssituation Blickbewegungen durch den Brillenträger stattfinden, wurden die Alvarezlinsen im Hinblick auf den Augendrehpunkt vermessen. Dazu wurde an der Hochschule Aalen ein Messaufsatz konzipiert, der sich an einem handelsüblichen Scheitel-brechwertmesser anbringen lässt. Dieser Aufsatz lässt sich schwenken, sodass die Messungen den Blickbewegungen um den Augendrehpunkt entsprechen. Die Messungen wurden für ein Blickfeld von 40° (±20°) durchgeführt. Dazu wurde auf den Gläsern ein Bereich über 9x9 Messpunkte vermessen, die jeweils in einem Abstand von 5° zueinander liegen.
Zunächst wurden die Brechwerte einer Sehhilfe für eine jeweilige Einstellung von ±4 dpt bestimmt. Die Schwankungsbreite der Sehhilfe mit -4 dpt (+4 dpt) liegt bei 0,0265 dpt (0,0797 dpt). Außerdem zeigen sich ein Astigmatismus und ein Refraktionsfehler, die durch die schrägen Blickwinkel verursacht werden. Wie zu erwarten, nehmen diese Aberrationen mit steigendem Blickwinkel zu. Der maximale Betrag des Astigmatismus liegt bei 0,40 dpt und der maximale Refraktionsfehler bei 0,52 dpt. Die Auswertung wurde über den Bereich eines Blickwinkels von ±10° gemacht.
Im Vergleich sind die Aberrationen der Focusspec-Brille mit dem positiven Brechwert größer als bei der Focusspec-Brille mit dem negativen Brechwert. Auch die größere Schwankungsbreite der Brille mit positivem Brechwert weist darauf hin, dass die verschiedenen Glasformen der Alvarezlinsen einen Einfluss auf die Abbildungsqualität haben könnten. Für eine detaillierte Betrachtung wird in dieser Bachelorarbeit zum ersten Mal eine Annäherung der Messergebnisse von Alvarezlinsen an diese sagittalen und tangentialen Bildschalen versucht. Vergleicht man alle Ergebnisse mit klassischen sphärischen Brillengläsern, zeigt sich, dass die Aberrationen der Alvarezlinsen vor allem am Rand größer sind. Dennoch ist die Art der Aberrationen vergleichbar mit denen der sphärischen Gläser.
Üblicherweise findet, im Rahmen der subjektiven Refraktion, eine Bestimmung der
Sehschärfe beim Blick durch das Zentrum von Einstärkengläsern statt. Das Ergebnis
dieser Messung dient als Entscheidungskriterium bei der Auswahl der Glasstärke
der jeweiligen Korrektion. Umgekehrt ist der erzielbare Visus ein wichtiges Maß
hinsichtlich der Beurteilung der Qualität einer Sehhilfe.
Da einige der heute verfügbaren Sehhilfen nicht nur eine Stärke besitzen ist es
besonders interessant die Sehschärfe nicht nur beim Blick durch das Zentrum
des Glases zu beurteilen, sondern unter verschiedenen Blickwinkeln zu ermitteln.
Der Aufgabenbereiche eines Augenoptikers ist vielfältig und er gilt als Spezialist, wenn es darum geht spezielle Sehanforderungen mit der richtigen Korrektionsmöglichkeit zu versorgen. „Die Aus-, Fort- und Weiterbildungsqualität in der Augenoptik gehört schon seit vielen Jahren zu der höchsten im Handwerk. Der Zentralverband der Augenoptiker (ZVA) hat es sich zur Aufgabe gemacht, das Kompetenzprofil der deutschen Augenoptiker auch für die Zukunft nachhaltig zu stärken.“ Egal in welcher Branche, Markt- und Wettbewerbsvorteile und somit auch die Sicherung des Arbeitsplatzes und des Lebensstandards, erlangt ein Jeder mit Wissen. Darum sollte es für jeden Menschen erstrebenswert sein, sein Wissen zu mehren.
Jeder Mitarbeiter muss gewillt sein seinen Wissensstand durch kontinuierliche Weiterbildung stetig auszubauen, denn der Kontakt zum Kunden will gelernt sein. Zu einem erfolgreichen Kundengespräch gehört mehr als nur eine richtige Aussprache, strukturiertes Vorgehen und Freundlichkeit. Übergeordnetes Ziel dieser Bachelorthesis ist es, neben der Erarbeitung der theoretischen Grundlagen interaktiver Videos in Lernarrangements, eine Lerneinheit zu erstellen, anhand derer sich Studenten der Augenoptik und speziell Studierende des dritten Semesters, die das Modul „Beraten und Verkaufen“ hören, orientieren können wie ein Verkaufsgespräch geführt wird. Die interaktiven Videos dienen der spielerischen Aneignung von Softskills und der Generierung überfachlicher Kompetenzen.
Das Ziel dieser Thesis ist es, eine UV-durchlässige Brillenfassung zu entwi-ckeln, welche aus kosmetischen Gründen zur Reduktion des Bräunungsabdrucks getragen wird. Hierfür wurde mithilfe einer Online-Umfrage eine Bedarfsanalyse durchgeführt.
Um eine solche Studie durchführen zu können, werden die notwendigen theoretischen und produktionspraktischen Vorüberlegungen angestellt. Im ersten Teil der Arbeit wird zunächst darauf eingegangen in welchen Branchen UV-durchlässige Materialien zum Einsatz kommen. Wichtige Ergebnisse können aus dem Bereich der Textilindustrie und dem Solarienbau gewonnen werden. Es stellt sich heraus, dass beispielsweise das Material Plexiglas® GS Sunactive der Firma Evonik Industries, für den Bau eines Prototyps geeignet sein kann.
Ein zentrales Ergebnis der durchgeführten Umfrage ist, dass 56 % der Befragten den Bräunungsabdruck ihrer Korrektionsbrille als störend empfinden. Frauen stört dieser signifikant stärker als Männer. Ein deutlich größerer Anteil der Befragten empfindet den Bräunungsabdruck ihrer Sonnenbrille als störend. Eine weitere wichtige Erkenntnis ist, dass weniger Befragte ihre Sonnenbrille zum Bräunen absetzen würden, hinterließe sie keinen Bräunungsabdruck. Dies würde zum Schutz der Augen beitragen. Insgesamt hätten 70 % der Befragten, Interesse an einer UV-durchlässigen Brillenfassung und wären auch bereit, hier einen höheren Preis zu bezahlen, als für eine handelsübliche Brillenfassung.
Beim Bau des Prototyps müssen einige DIN-Normen beachtet werden. Das verwendete Material darf die Gesundheit und Sicherheit des Trägers nicht beeinflussen. Die Augen müssen vor schädlichen UV-Strahlen geschützt werden, weshalb die Gläser weiterhin mit UV-Schutz ausgestattet sein müssten. Der fertige Prototyp muss ferner eine angemessene mechanische Stabilität und Temperaturbeständigkeit aufweisen.
Der fertige Prototyp zeigt, dass es möglich ist, eine UV-durchlässige Brillenfas-sung, die eine ausreichend mechanische Stabilität und Temperaturbeständigkeit hat, zu entwickeln und zu produzieren. Wie die Umfrage gezeigt hat, gibt es Interessenten und somit eine potentielle Nachfragesituation für eine derartige Produktneuheit; auf den im Zusammenhang mit dieser Arbeit gefertigten Prototypen wird im Verlauf der Arbeit näher eingegangen.
Diese Bachelorthesis beschreibt Gründungs- und Unternehmensführungsstrategie anhand einer handlungsorientierten und konstruktivistischen Lernstrategie VaKE (Value and Knowledge Education) zum Erlangen der beruflichen Handlungsfähigkeit. Dabei teilt sich die Arbeit in drei Hauptteile wie folgt auf: Im ersten Teil wird beschrieben welche Kompetenzen und Eigenschaften zusammen die berufliche Handlungsfähigkeit ergeben, und wie diese erworben werden kann. Weiterhin wird der geschichtliche Hintergrund von Qualifikationen und Handlungskompetenzen dargestellt. Im zweiten Teil dieser Bachelorthesis wird die Theorie zu den Gründungs- und Unternehmensführungsstrategien im Rahmen der allgemeinen Meisterprüfungsordnung (AMVO) herausgearbeitet und beschrieben. Dabei werden nach der AMVO im zweiten Handlungsfeld die Gründungs- und Übernahmeaktivitäten sowie das dritte Handlungsfeld der Unternehmensführungsstrategien genauer beschrieben. Das zweite Handlungsfeld gliedert sich in die Bedeutung der persönli-chen Voraussetzungen für den Erfolg der beruflichen Selbstständigkeit, die wirtschaftliche, gesellschaftliche und kulturelle Bedeutung des Augenoptiker Handwerks, der Nutzen von Handwerksorganisationen sowie Entscheidungen zum richtigen Standort eines Augenoptischen Betriebes. Das dritte Handlungsfeld beschreibt die Bestimmungen des Arbeits-und Sozialversicherungsrechts, Instrumen-te zur Durchsetzung von Forderungen sowie theoretischen Grundlagen zur Insolvenz und deren mögliche Konsequenzen. Der dritte Teil dieser Bachelorthesis setzt sich aus handlungsorientierten Aufgaben zu den Gründungs- und Unternehmensführungsstrategien zusammen, welche im zweiten Teil genau beschrieben wurden. Diese Aufgaben werden anhand der konstruktivistischen Lernstrategie VaKE durchgeführt.
Augenoptische Betriebe schaffen mit erfolgreichen Geschäftsmodellen den Sprung aus der Vergleichbarkeit. Erfolgsentscheidend auch im Hinblick auf die Differenzierung gegenüber dem Internet ist das Angebot optometrischer Dienstleistungen.
Ziel dieser Bachelorthesis ist die Erforschung und Entwicklung von erfolgreichen Geschäftsmodellen in der Augenoptikbranche. Die Basis von Geschäftsmodellen bilden die optometrischen Dienstleistungen. Durch das einheitliche Produkt- und Leistungsangebot ist es wichtig Kundenerlebnisse zu kreieren, um sich von Wettbewerbern abzuheben und eine langfristige Bindung an das Unternehmen zu gewährleisten.
Im Hinblick auf die Kontaktlinsenbranche werden Geschäftsmodellinnovationen erläutert, die verhindern sollen, dass Kunden ins Internet abwandern. Daraus ergab sich die Frage, ob diese noch zeitgemäß sind, oder ob ein Umbruch hinsichtlich dieser Frage stattfindet. Mithilfe eines Experteninterviews mit einem Inhaber eines stationären Familienunternehmens wird der zunehmende Wandel der Konsumenten sehr deutlich. Nur wer am Zeitgeist des Geschehens bleibt und sich auf veränderte Rahmenbedingungen, wie die zunehmende Konnektivität einlässt, wird mit dem „neuen“ Konsumentenverhalten auch in Zukunft mithalten können.
Zielsetzung: Töchter sind an der Spitze von Familienunternehmen nach wie vor unterrepräsentiert
und sehen sich, wenn einmal in dieser Position angekommen, mit verschiedensten
Herausforderungen konfrontiert. Ziel dieser Bachelorarbeit ist es, die
Herausforderungen für die Töchter in der Nachfolge genauer zu untersuchen, um
aufzuzeigen, wo potenzielle Chancen für die Nachfolgerinnen bestehen.
Methode: Es wurde eine empirische Untersuchung in Form einer schriftlichen Befragung mittels standardisiertem Fragebogen mit 24 Teilnehmerinnen durchgeführt. Hierfür war es
zunächst nötig, fünf Annahmen aufzustellen, die in ihrer Summe zur Haupthypothese
führten. Diesen Annahmen wurden verschiedene Fragen des Fragebogens zugeordnet, um darüber die Haupthypothese zu be- oder widerlegen. Die
Haupthypothese lautet: „Töchter sehen sich im Rahmen der familieninternen
Unternehmensnachfolge mit diversen Herausforderungen konfrontiert.“
Die Annahmen behandeln folgende Themenbereiche:
1. die patriarchalischen Familienstrukturen innerhalb der Herkunftsfamilie, die zu
einer geringeren Bereitschaft seitens des Übergebers führen können, das Familienunternehmen an die Tochter zu übergeben; Außerdem kann daraus eine
seltenere Ernennung der Tochter zur Nachfolgerin des Familienunternehmens
resultieren
2. die unzureichende Vorbereitung der Nachfolgerin im Hinblick auf eine nicht
langfristig geplante Übergabe
3. die geringe Kooperation der Mitarbeiter, Kunden und Lieferanten mit der Übernehmerin
4. das wenig selbstbewusste, überzeugte Verhalten von Frauen im Hinblick auf das
In-Anspruch-Nehmen der Führungspositionen in Familienunternehmen
5. der in besonderem Maße anzumeldende Führungsanspruch und das Sichbeweisen-
Müssen der Tochter gegenüber ihrem Vorgänger in Familienunternehmen
Ergebnisse: Die Ergebnisse zeigen, dass die in dieser Arbeit formulierten Annahmen nicht bestätigt wurden. Das bedeutet, dass sie sich nicht als erschwerte Herausforderungen für Töchter im Familienunternehmen darstellen. Auch bei
vorhandenen patriarchalischen Familienstrukturen wurde die Übergabe an die weibliche Nachfolgerin befürwortet. Ebenso fühlten sich die Frauen bei nicht frühzeitig geplanten Übergaben durchaus gut vorbereitet. Sie besaßen entgegen der Annahme einen starken Willen und die Überzeugung, das Familienunternehmen in
die nächste Generation führen zu können. Des Weiteren haben sich die Geschäftspartner kooperativ gezeigt. Auch die Annahme, dass Frauen sich in
Familienunternehmen besonders beweisen müssen und einen starken Führungsanspruch anmelden müssen, konnte widerlegt werden.
Schlussfolgerung: Die Arbeit macht deutlich, dass Frauen in Familienunternehmen mehr als fähig und bereit dazu sind, die Rolle der Nachfolgerin einzunehmen. Aus diesem Grund sollte Töchtern der Zugang zu Führungspositionen vermehrt ermöglicht werden und dies
als Chance genutzt werden. Die Chance auf eine erfolgreiche nächste Generation des Familienunternehmens mit einer Frau an der Spitze.
Die Leuchtdichte spielt in der Lichttechnik eine zentrale Rolle. Die korrekte
Bestimmung der Leuchtdichte ist wichtig, allerdings messtechnisch anspruchsvoll. Die Arbeit beschreibt die Kalibrierung einer handelsüblichen CCD-Spiegelreflexkamera, um mit dieser Leuchtdichtemessungen durchführen zu können. Für die Kalibrierung wird zunächst
eine Ulbricht-Kugel mit Hilfe eines Radiospektrometers charakterisiert. Anschließend werden Bilder der strahlenden Fläche der Ulbricht-Kugel bei verschiedenen Leuchtdichten und unterschiedlichen Kameraeinstellungen aufgenommen. Daraus kann der Zusammenhang zwischen Leuchtdichte und Grauwert des
aufgenommenen Bildes hergestellt werden und eine Formel zur Berechnung der
Leuchtdichte aus dem Grauwert ist bestimmbar. Um die Bilder bequem auswerten zu können, wird ein Programm unter Visual Basic geschrieben.
Das Programm bestimmt die Leuchtdichte für alle Pixel im Bild und stellt das Bild anschließend für mehrere Leuchtdichtebereiche in Falschfarben dar. Mit dem
Mauszeiger kann der Grauwert und die Leuchtdichte punktuell abgerufen werden. Zudem berechnet das Programm aus einem manuell eingegebenen Grauwert die Leuchtdichte. Eine Anzeige in Originalgröße oder eine Ausschnittvergrößerung des Bildes sind möglich. Zur Anzeige der Leuchtdichte stehen drei verschiedene Skalen zur Verfügung.
Die Bachelorarbeit widmet sich der Entwicklung eines automatisierten Telefonhörtests und dessen Nutzen in der Praxis der Akustikerin/ des Akustikers.
Eine kostenfreie, freiverfügbare Telefonleitung wird eingerichtet und der Nutzen sowie die Qualität des
Hörtests werden mithilfe einer Studie analysiert. Der Telefonhörtest entsteht in Kooperation mit der Hochschule Aalen für Technik und Wirtschaft und dem Frauenhofer-Institut Oldenburg
für digitale Medientechnologie. Für die Entwicklung des Telefonhörtests sind theoretische und praktische
Vorüberlegungen zu der Umsetzung notwendig. Im ersten Teil der Arbeit wird auf das Telefon und seine Funktionsweise sowie seine Bedeutung in der Gesellschaft eingegangen. Ein wichtiger Aspekt ist hierbei die Übertragungsbreite des Telefons. Interessant ist auch die Erkenntnis des unveränderten Trends der Freizeitbeschäftigung der Deutschen. Im weiteren Verlauf werden die Anforderungen und die Umsetzung des Telefonhörtest geklärt. Der Test muss jederzeit frei verfügbar und kostenlos zu nutzen sein. Darüber hinaus sollte er leicht zu bedienen sein und nur wenig Zeit in Anspruch nehmen. Die Aufnahmen müssen zwingend gut verständlich, wiederholbar und bei jedem Anruf in gleicher Lautstärke wiedergegeben werden. Das
Tonbearbeitungsprogramm Audacity 1.3 Beta wird zur Aufnahme und Bearbeitung der Klangbeispiele verwendet. Die Datengröße der Aufnahmen werden für den Telefonserver minimiert und anschließend mit Audacity 1.3 Beta bearbeitet. Für die Validierung des Telefonhörtests wird mithilfe von Fragebögen eine Studie mit fünf Hörakustikbetrieben durchgeführt. Die zentralen Ergebnisse der durchgeführten Studie sind, dass 97 % der Hörgerätekunden und 81 % der Hörakustiker und Hörakustikerinnen ein Nutzen des Telefonhörtest sehen. 93 % der Befragten Akustiker und Akustikerinnen würden den Telefonhörtest in Zukunft anwenden oder bei passenden Fällen zur Unterstützung bei einer Hörgeräteanpassung nutzen. Der entwickelte Telefonhörtest zeigt, dass es möglich ist die gestellten Anforderungen umzusetzen. Die Verständlichkeit der Klangbeispiele werden von 88 % der Studienteilnehmer mit gut bis sehr gut bewertet und ist somit erfüllt. Da es sich um einen automatisierten Telefonhörtest handelt, ist auch die Wiederholbarkeit in gleichbleibender Lautstärke gegeben.
Im Rahmen dieser Bachelorarbeit „Konzept zur praktischen Entwicklung einer videobasierenden e-Learning-Plattform zur Unterstützung hörakustischer Praktikumsveranstaltungen am Beispiel der Tonaudiometrie“ wird ein Leitfaden entwickelt, anhand dessen es künftig ermöglicht wird, Lernvideos zur Unterstützung der Lehrveranstaltung „Audiologie Praktikum“ zu erstellen. Die Lernvideos sollen als Ergänzung der Lernveranstaltung dienen und den Studierenden wie den Praktikumsbetreuern als praktische Veranschaulichung verschiedener Themengebiete wie „Messung der Luftleitung“ dienen.
Im ersten Schritt werden die möglichen Themengebiete analysiert, bei denen sich eine praktische Veranschaulichung im Rahmen eines e-Learning-Moduls anbietet, welche Themengebiete für die Studenten ausschlaggebend sind und ob diese mit der in der Modulbeschreibung definierten Kompetenzen deckungsgleich sind. Es wird im Vorfeld überlegt, wie der Begriff des „e-Learning“ definiert ist und welche Vor- und Nachteile dieser mit sich bringt. Darüber hinaus wird der aktuelle „Stand der Entwicklung“ kurz erörtert, um aktuelle Themen wie beispielsweise Webinare einzuordnen. Vorrangig wird jedoch die Frage diskutiert, wie die Themen ansprechend und lernfördernd in einem entsprechenden Videoformat dargestellt werden können.
In diesem Rahmen wird auf die einzelnen Schritte eingegangen, die zur Entwicklung eines Lernvideos notwendig sind.
Es hat sich dabei gezeigt, dass die Erstellung des Drehbuchs die Grundlage jedes professionellen Lernvideos darstellt. Auch benötigte Softwareprogramme und Ausstattung, wie beispielsweise die Kamera, sind ausschlaggebend für die erfolgreiche Produktion eines e-Learning-Videos. Die Auswahl der Akteure und der Hintergrundsprecher/in, die eigentliche Videoaufnahme sowie deren fachgerechte Ver- bzw. Bearbeitung stellt einen weiteren wichtigen Teil in der praktischen Entwicklung von e-Learning-Videos dar.
Durch die im Anhang beigefügten Checklisten wird eine Unterstützung in der Umsetzung des vorliegenden „Konzept zur praktischen Entwicklung einer videobasierenden e-Learning-Plattform zur Unterstützung hörakustischer Praktikumsveranstaltungen am Beispiel der Tonaudiometrie“ gegeben. Die Umsetzung des Leitfadens wird in Form von vier produzierten Lernvideos veranschaulicht.
Das Ausmaß der Beeinträchtigung durch eine Schwerhörigkeit ist eng mit dem Verlust des Sprachverstehens verbunden.
Das oberste Ziel einer Hörsystemversorgung ist deshalb das Wiederherstellen der Kommunikationsfähigkeit.
Beim Nachweis des Versorgungsnutzens stellt die Sprachaudiometrie einen wesentlichen Bestandteil dar.
In dieser Bachelorarbeit geht es um den Vergleich von Oldenburger Satztest und Oldenburger Kindersatztest in der Sprachaudiometrie Erwachsener.
Im Fokus der Untersuchungen standen dabei die Dauer der Messdurchführungen, der damit verbundene Konzentrationsaufwand für den Kunden und die Höranstrengung. Ziel der Bachelorarbeit war es aufzuzeigen, dass der Oldenburger Kindersatztest eine geeignete sprachaudiometrische Methode zur Ermittlung der Sprachverständlichkeitsschwelle bei Erwachsenen darstellt, da er aufgrund seiner reduzierten Durchführungsdauer den Kunden weniger belastet und anstrengt.
Angesichts knapper werdender Finanzmittel und der Erhaltung und Förderung von gesellschaftlicher Akzeptanz für Entwicklungsprojekte, ist deren nachhaltige Wirksamkeit von zentralem Interesse. Zur Beurteilung des Erfolgs von Entwicklungszusammenarbeit hat der Ausschuss für Entwicklungshilfe der OECD internationale Evaluationskriterien geschaffen.
Ziel der Arbeit ist es, das gemeinsame Schwerhörigenhilfsprojekt vom Lions Club Kelkheim und Lions Club Anuradhapura „Hilfe für kleine Ohren“ in Sri Lanka vorzustellen und seine bislang erreichte Wirkung bezüglich seiner Zielsetzung zur nachhaltigen Entwicklung zu analysieren und gegebenenfalls Optimierungsmöglichkeiten für zukünftige Entscheidungsprozesse zu formulieren.
Die Evaluierung berücksichtigt die Rahmenbedingungen des Projekts und basiert auf der Auswertung einer Umfrage zum Anpasserfolg von Hörgeräten durch lokale Mitarbeiter. Zusätzlich werden die Patientendaten und die Ausbildung der lokalen Mitarbeiter zur Beratung und Anpassung von Hörgeräten analysiert.
Das Ergebnis der Diskussion zeigen, dass in mehreren Bereichen Erfolge zu verzeichnen sind. Insbesondere in der Relevanz und der Effizienz der Entwicklungsmaßnahme. Sie tragen zu den kurzfristigen und teilweise auch zu den langfristigen Projektzielen bei. Dabei wird speziell die Verbesserung der Situation für die Schwerhörigen und die finanzielle und personelle Unabhängigkeit des Projekts angestrebt. Doch es zeigen sich auch Schwächen die das langfristige Fortbestehen des Projekts gefährden und die Effektivität der Maßnahme beschränken.
Zusammenfassend lässt sich festhalten, dass das Projekt „Hilfe für kleine Ohren“ in Sri Lanka noch am Anfang steht. Es ist zwar ein solider Grundstein gelegt, dennoch werden weitere Unterstützungsmaßnahmen zur Verbesserung der Schwerhörigenversorgung und deren langfristigen Wirksamkeit notwendig sein. Dabei handelt es sich unter anderem um die Ausbildung weiterer lokaler Mitarbeiter in der Versorgung mit Hörhilfen. Diese könnten in regelmäßigen Abständen durch freiwillige Hörakustiker oder Hörakustik-Studenten im Rahmen ihres Studiums und unter Einbeziehung lokalen Fachpersonals zusätzlich unterstützt werden.
Die Six Sigma-Methodik hilft Unternehmen als strategisches Marketing-Tool die Qualität der Produkte und Prozesse durch den Einsatz von statistischen Werkzeugen und fundierten Prozessoptimierungsmethoden zu verbessern, die Kunden zufriedener zu machen und die Abläufe im Unternehmen zu beschleunigen. Ziel der Arbeit ist es herauszufinden, ob sich dieses Qualitätsmanagement-Konzept auch auf die Gegebenheiten, Prozesse und Anforderungen in einem augenoptischen Betrieb wirksam anwenden lässt. In fünf klar definierten Projektphasen werden unter anderem durch die Erhebung, Analysierung und Auswertung von prozessbezogenen Daten Schwachstellen in betrieblichen Abläufen faktenbasiert offengelegt und fundiert verbessert. Ziel ist es, die Fehlerquote eines Prozesses auf ein Maß zu reduzieren, so dass von einer (annähernden) Null-Fehler-Qualität gesprochen werden kann. Die statistische Basis der Six Sigma-Methodik findet sich in der Tatsache begründet, dass alle betrieblichen Vorgänge einer Streuung vom statistischen Maß des „Soll-Wertes“ (Mittelwert μ) unterliegen, die sich durch eine Gauß’sche Normalverteilungskurve beschreiben lassen. Diese Streuungen (hier als Varianz oder Standardabweichung (σ) bezeichnet) sind als „Ist-Werte“ am Ende eines Prozesses zu verstehen. Um die Leistung eines Prozesses beurteilen zu können wird geprüft, wie oft die errechnete Standardabweichung zwischen den Zielwert und die Spezifikationsgrenzen passt. Die Anzahl stellt den Sigma-Wert des Prozesses dar. Die zentrale Aufgabe dieser Thesis ist es, darzulegen ob ─ und wenn ja ─ wie die Six Sigma-Methodik für kleine und mittlere Unternehmen im augenoptischen Fachbetrieb effektiv und sinnvoll zu implementieren ist. Die Recherchen und Analysen der Arbeit kommen diesbezüglich zu dem Ergebnis, dass Six Sigma durchaus eine Option für ein augenoptisches Unternehmen darstellen kann, das qualitative Niveau von Prozessen und Dienstleistungen zu heben. Jedoch bedarf es besonderer Sorgfalt bei der Auswahl geeigneter Prozesse und einer detaillierten Kosten-Nutzen-Aufstellung um mit Six Sigma effizient zu arbeiten und nachhaltigen Erfolg zu haben.
Purpose
Automated scanpath comparison metrics should deliver an objective method to
evaluate the similarity of scanpaths. The aim of this thesis is an evaluation of
seven existing scanpath comparison metrics in static and dynamic tasks in order
to provide a guidline that helps to decide which algorithm has to be chosen for a
special kind of task.
Methods
The applicability of the algorithms for a static, visual search task and a dynamic,
interactive video game task as well as their constraints and limitations were tested.
Therefore, binocular gaze data were recorded by using the eye tracking system The
Eye Tribe (The Eye Tribe ApS, Copenhagen/ Denmark). Objective task performance
measures from 21 subjects were used in order to create scanpath groupings
for which a relevant effect of dissimilarity was to be expected. Objective task performance
measures such as task performance time were statistically evaluated and
compared to the results gained by the comparison metrics.
Results
Four of the algorithms being used successfully identified differences for static and
dynamic tasks: MultiMatch, iComp, SubsMatch and the Hidden Markov Model.
ScanMatch was very sensitive for the static task but not applicable to the dynamic
task whereas FuncSim was suitable for dynamic but not for static tasks. Eyenalysis
failed to detect any effect.
Conclusion
The applicability of scanpath comparison metrics depends on the state of the task,
respectively on the kind of experimental set up. In future, the application area for
eye tracking will expand and an improvement of automated scanpath comparison
metrics is therefore required.
Die optimale und exakte Brillenglaszentrierung ist seit je her der Mittelpunkt eines jeden Verkaufsgespräches. Die Anforderungen an eine exakte Brillenglaszentrierung steigen stetig, insbesondere nach der Etablierung individueller Gleitsichtgläser. Nur eine optimale Zentrierung ermöglicht dem Kunden ein angenehmes Tragegefühl. Deshalb ist die exakte Brillenglaszentrierung ein Muss. Die Möglichkeiten der Zentrierung reichen mittlerweile von manuellen Methoden über stationäre Videozentriergeräte bis hin zu Applikationen in Kombination mit Tablets. Letztere stellen die jüngste Innovation im Zeitalter fortschreitender Digitalisierung dar.
Ziel dieser Bachelorthesis ist es, die Erwartungen und die Zufriedenheit deutscher Augenoptiker in Bezug auf tablet-basierte Applikationen zur Brillenglaszentrierung zu ermitteln. Deshalb wird eine Befragung bei 500 unabhängigen Augenoptikern der Bundesrepublik Deutschland durchgeführt. Anhand der gewonnen Ergebnisse wird erfasst, welche Erwartungen sie haben und abgefragt, ob diese erfüllt werden oder nicht. Zudem wird untersucht, ob die Applikationen den Genauigkeitsanforderungen genügen und ob bestehenden Methoden, vor allem aber Videozentriersystemen, durch Apps zukünftig Gefahr droht.
Die Befragung zeigt, dass die Augenoptiker vergleichsweise wenig zufrieden sind, da ihre Anforderungen an eine Applikation zur Brillenglaszentrierung bisher nur unzureichend erfüllt werden. Dennoch ist diese neuartige Methode der Brillenglaszentrierung nicht zu unterschätzen. Es zeigt sich, dass der Trend zukünftiger Zentriermethoden immer mehr in Richtung tablet-basierte Applikationen geht, jedoch nur unter der Voraussetzung, dass diese zukünftig die Anforderungen der Anwender erfüllen. Die Apps befinden sich noch im Anfangsstadium, können sich aber durch weitere Entwicklungen früher oder später als feste Zentriermethode etablieren.
Circa 15% der Einwohner in Marokko leben unterhalb der Armutsgrenze. Eine gute medizinische Versorgung und die Versorgung mit Sehhilfen sind nicht gewährleistet. Bisher gibt es nur wenig Zusammenarbeit zwischen Marokko und Deutschland bezüglich Sehhilfen. Im Rahmen der vorliegenden Bachelorarbeit ist eine Zusammenarbeit zwischen den marokkanischen und deutschen Vereinen an drei Orten zustande gekommen. Diese Arbeit wird auf langfristige Basis eingeführt und drei Termine sind bereits für das kommende Jahr 2016 vereinbart. Es wurde untersucht, welche Form der Unterstützung für eine bessere Versorgung von Sehhilfen für die arme Landbevölkerung von Marokko geeignet wäre, wie man das am besten realisieren könnte und welche Stärken bei den Sehhilfen erforderlich sind.
Zur Bestimmung der benötigten Stärken der Sehhilfen wurden 180 Patienten in drei verschiedenen Orten in Südmarokko untersucht. In der Untersuchung wird die Sehschärfe mit und ohne Korrektion überprüft. Zudem wurden Kontakte zu verschiedenen Hilfsorganisationen geknüpft und bewertet.
Die Ergebnisse dieser Studie zeigen, dass es in der marokkanischen Landbevölkerung teilweise zu sehr hoher Fehlsichtigkeit kommt, die zu selten oder zu spät mit Sehhilfen korrigiert werden.
Nicht nur an diesen drei Orten, sondern überall, insbesondere in den Dörfern auf dem Land. Deswegen gibt es viele andere Stellen an denen die Menschen mit Sehhilfen versorgt werden können.
Purpose: The purpose of this thesis is to provide a comprehensive literature review about albinism as an inherited metabolic disorder of melanin synthesis along with those related conditions impacting the visual system. As such, it addresses eye care emphasizing the visual consequences of albinism along with diagnostic and treatment options.
Methods: Background knowledge about ocular development is given as well as information about etiological biochemical and genetic processes. The current classification, clinical findings and their assessment and management options are presented based on recent results of research. In conclusion, two case reports are described as examples of visual care options.
Results: Melanin plays a big role in the retinal and chiasmal development. Melanin biosynthesis can be disrupted by different genes in various ways which leads to the current classification of albinism. Clinical findings include fundus hypopigmenta-tion, nystagmus, iris transillumination, photophobia, foveal hypoplasia, excessive chiasmal decussation, reduced visual acuity, high astigmatism (with-the-rule), strabismus and decreased stereopsis. Treatment options to improve visual acuity, fixation and binocularity are (tinted) prescription lenses and contact lenses, low vision aids, surgical procedures and vision therapy. Medication and supplementa-tion for increased pigmentation are currently being tested on mice.
Conclusions: Albinism is caused by genetic mutations resulting in ocular and cutaneous hypopigmentation. It establishes various phenotypes that require different therapy approaches in order to improve vision and therefore quality of life.
Purpose
To determine the stereo threshold and inherent variability with a monitor-based two-rod test at various eccentricities of the visual field. Additionally, to evaluate the duration of this procedure.
Subjects and methods
A pilot trial was conducted in five ophthalmologically normal subjects (2 male and 3 female) aged 21 – 23 years. Two black rods on white background, which appeared under an angle of 1° were presented in a viewing distance of 5.0 meters. The right rod was stationary, whilst the left rod appeared under a stereoscopic parallax, with an either proximal or distal displacement to the image plane. Threshold determination was assessed at seven eccentricities of the visual field by a staircase method. Eccentricities were 0° centrally, 5° to the right and left, 10° to the right and left and 15° to the right and left of the visual field. Proximal and distal displacement as well as the sequence of eccentricities were presented in random order. Stereo acuity was measured in two different sessions for four subjects and in five different sessions for one subject. For all sessions the duration was recorded. All sessions were separated by a time interval of at least 24 hours and no longer than 7 days. Evaluation was made by Wilcoxon test and Kruskal Wallis test at the 95% confidence level (CI) and the median was assessed for all thresholds.
Results
Stereo acuity declines with increasing eccentricities of the retina similar to visual acuity. While at 0° eccentricity thresholds were found to be lowest with (median) 5.0 seconds of arc (‘’) and the CI (0.5’’, 30.5’’) for all measurements, they increased to 112.2’’ at 15° eccentricity to the left in proximal displacement. Distal it was 19.9’’ centrally and 112.2’’ to the right at 15° eccentricity with CI (0.5’’, 30.5’’) for all measurements.
Repeatability of the threshold determination was found to be best at 0° eccentricity with proximal displacement showing the exact same result in the repetitive session and poorest repetition was found at 15° eccentricity to the left with distal displacement. Distal repeatability was worse than proximal. Median and CI of duration time was 5.3 (3.2, 8.3) minutes.
Conclusion
Stereo acuity thresholds are repeatable however increase with increasing eccentricity. Repetitions of the threshold determination do not vary considerably. The duration of these measurements indicates the monitor-based two-rod test as a fast procedure, that can be applied in future studies. The test program is limited by an imperfect algorithm and the stereoscopic images evoke cues, this should be reworked.
Im Rahmen dieser Bachelorthesis soll ein Leitfaden für das kompetenz- und handlungsorientierte Lehren und Prüfen erstellt werden. Am Beispiel der Arbeitsunterweisung des „Kommunikationstrainings“ soll verdeutlicht werden, wodurch sich eine Handlungs- und Kompetenzorientierung sowohl in Lehrveranstaltungen, als auch in Prüfungen auszeichnet.
Dazu wird zunächst die Theorie, die zur Entstehung der Handlungs- und Kompetenzorientierung in den Vorlesungen und Lehrveranstaltungen geführt haben, umrissen und in einen geschichtlichen Rahmen eingeordnet. Besonders beleuchtet wird dabei die internationale Leistungsmessung von Bildungsstandards; das sogenannte Bildungsmonitoring.
Der zweite Teil dieser Thesis gibt einen Überblick über die Definitionen von Kompetenzen und Handlungskompetenzen in schulischer, beruflicher und hochschulischer Bildung. Die Ansätze werden einander gegenübergestellt und Unterschiede und Gemeinsamkeiten herausgestellt.
Im dritten Teil der Arbeit wird die Theorie mit der Praxis verknüpft und die Handlungs- und Kompetenzorientierung anhand von Beispielen in konkrete Lehr- und Lernsituationen übertragen. Die hier entwickelten Prüfungsfragen und Lösungen werden auf ihren Kompetenzgehalt und ihre Handlungsorientierung hin untersucht und analysiert.
In der globalen Industrie und in der Medizin ist der 3D-Druck von Bauteilen oder als Grundlage für die Zellbesiedelung mittlerweile nicht mehr wegzudenken. Um Kosten und Zeit zu sparen, werden oft zunächst Prototypen im 3D-Druckverfahren hergestellt und auf Funktionalität getestet. Ziel der vorliegenden Arbeit „Entwicklung eines 3D-Ohrmodells“ war es zu überprüfen, ob es der aktuelle Stand der Forschung und Technik im vielseitigen Bereich des 3D-Druckes ermöglicht, ein 3D-Ohrmodell zu drucken, welches möglichst realitäts-nah und detailgetreu das menschliche Ohr wiederspiegelt und zu Ausbildungszwecken herangezogen werden kann. Dieses Ohrmodell soll verschiedene Anforderungen erfüllen. Einerseits soll es verschiedene Härtegrade aufweisen, vergleichbar mit dem menschlichen Ohr, insbesondere mit den Strukturen Ohrläppchen (Fettgewebe & Haut, weich), Knorpel (mittelhart) und Knochen (hart). Andererseits soll es anatomisch korrekt sein, da es auf dem Markt kaum Modelle gibt, die die anatomischen Gegebenheiten realitätsnah darstellen. Weiterhin soll es möglichst transparent sein, sodass es langfristig als Übungsohr in der Ausbildung von Hörgeräteakustiker/-meistern oder Studieren-den der Hörakustik in den Bereichen Ohrabformung und In-situ-Sondenschlauchplatzierung verwendet werden kann. Der Vorteil eines transpa-renten Modells ist die einfachere Beurteilung der Platzierung von wichtigen Komponenten, wie bspw. Sondenschlauch oder Abformmasse.
Als Ausgangslage für das 3D-Ohrmodell dienten Scan’s eines Ohrmuschelmo-dells und einer tiefen Ohrabformung, die per 3D-Scanner eingescannt, mit der Hilfe von CAD Experten bearbeitet, zusammengefügt und anschließend ausgedruckt wurden. Das Ergebnis dieses Entwicklungsprozesses ist ein Modell, welches die anatomischen Gegebenheiten sehr gut darstellt. Es wurde zunächst aus Kostengründen nur in unterschiedlichen Graustufen gedruckt, ein transparentes Modell ist aber zukünftig ebenso herstellbar. Das entwickelte Ohrmodell weist zwar unterschiedliche Härtegrade auf, Ohrläppchen und knorpeliger Teil des Ohres sind aber im direkten Vergleich zum menschlichen Ohr zu hart. In diesem Punkt besteht zukünftig noch viel Entwicklungspotential.
Das Ergebnis dieser Arbeit kommt der Ausgangsidee bereits ziemlich nah, es muss aber noch eine Weiterentwicklung der Materialqualität und –art stattfinden.
Im Rahmen der vorliegenden Bachelorarbeit wurden bei 41 Probanden sowohl objektive als
auch subjektive Refraktionsbestimmungen durchgeführt. Bei den Probanden wurde die
klassische monokulare Refraktionsbestimmung mit dem Kreuzzylinder durchgeführt. Im
Anschluss an diese Messung, wurde ein monokularer Feinabgleich unter binokularen
Bedingungen für Sphäre, Zylinder und Achse am Zyklofusionstest durchgeführt. Ziel ist es zu
prüfen, ob zum einen die monokulare Refraktion unter binokularen Bedingungen am
Zyklofusionstest ein gleichwertiges Verfahren zur Refraktionsbestimmung ist wie die
monokulare Refraktion und zum anderen ob sich unter binokularen Bedingungen eine andere
Zylinderachse ergibt wie unter monokularen. Zu Beginn der Arbeit werden zunächst die
Grundlage zum Zyklofusionstest und der Aufbau des Testes erläutert. Zusätzlich wird in den
Methoden die Durchführung der Messung erläutert. In der Auswertung der Ergebnisse wurde
besonders auf die Zylinderachse und -stärke geachtet. Hier ergaben sich zwischen den beiden
Messverfahren leicht unterschiedliche Refraktionen. Im ersten Messdurchgang ergab sich für
die Differenz im sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,43 dpt und
im zweiten Messdurchgang von ±0,29 dpt um die mittlere Refraktion. Die beiden Messmethoden
unterscheiden sich daher nicht relevant voneinander. In 72% der Fälle führten beide
Messmethoden zur gleichen Visusstufe. Beim wiederholten Durchführen der Messung wurde in
77% der Fälle die gleiche Visusstufe erreicht. Des Weiteren ergab sich für die beiden Verfahren
eine ähnliche Reproduzierbarkeit. Bei der binokularen Messung ergab sich für die Differenz im
sphärischen Äquivalent eine 95% Übereinstimmungsgrenze von ±0,37 dpt und bei der
monokularen Messung von ±0,39 dpt um die mittlere Abweichung. Um die Handhabung und
die Anwendbarkeit interpretieren zu können wurden zum einen die Dauer der Messungen mit
einander verglichen und zum anderen die Probanden nach der Messung zu ihrer persönlichen
Meinung befragt. Für die Messung am Zyklofusionstest ergab sich eine Prüfdauer von ca. 10
Minuten. 56% der Probanden empfanden die Beurteilbarkeit während der monokularen
Refraktion am einfachsten und angenehmsten. Für 15% war die Beurteilung am Zyklofusionstest
einfacher und die restlichen 29% konnten keinen Unterschied in der Beurteilung
feststellen. Anschließend wird in der Diskussion auf Komplikationen während der Messung
anhand von Einzelfällen eingegangen und mögliche Fehlerquellen werden aufgezeigt.
Abschließend ist festzustellen, dass der Zyklofusionstest eine neue Messmethode ist, die im
Wesentlichen die gleichen Ergebnisse und eine gleich gute Reproduzierbarkeit wie die
klassische monokulare Refraktion aufweist und in Zukunft mit in den Refraktionsablauf
integriert werden kann.
Das Ziel dieser Arbeit ist die Erstellung eines Konzepts für eine Software zum Erler-nen der Refraktionsbestimmung, welches die Erweiterung um zusätzliche Refraktionsschritte und Refraktionsmethoden sowie eine Umsetzung der Programmierung ohne augenoptische Kenntnisse ermöglicht. Die Programmgestaltung soll in Oberfläche, Funktionsumfang und Probandeneigenschaften der realistischen Refraktionsbestimmung näher kommen als die bisher verfügbaren Refraktions-Simulationsprogramme „Refsim7“ und „Electric Optitian PE“.
Das Konzept umfasst die monokulare Refraktion für die Ferne mit den Methoden Kreuzzylindermethode und Zylindernebelmethode für die Bestimmung des Astigmatismus und Rot-Grün-Test und Sukzessiv-Abgleich als Methoden für den monokularen sphärischen Feinabgleich. Des Weiteren umfasst es die Umsetzung vier verschiedener Eigenschaften des Probanden, die sich auf die Kommunikation auswirken: normales Verhalten, kann sich nicht entscheiden, verwechselt rechts und links und hört schlecht. Ebenso werden in dem Konzept die Aspekte Augenerkrankungen und Hornhautscheitelabstand berücksichtigt. Dazu gibt es fünf verschiedene Auffälligkeiten des Probanden, die auf den Erkrankungszustand des Auges, auf das Erkrankungsrisiko oder auf die Berücksichtigung des HSA schließen lassen. Diese sind starke Refraktionsänderung über einen kurzen Zeitraum, ein optisch nicht korrigierbares Problem, ein geringer Visus, ein höheres Probandenalter und eine höhere Fehlsichtigkeit.
Die Vorgehensweise für die Arbeit ist wie folgt strukturiert. Zunächst wird eine Recherche über bestehende Programme zum Erlernen der Refraktion durchgeführt. Anschließend erfolgt die Erarbeitung von Grundlagen zur Refraktionsbestimmung und anderen Aspekten der Refraktion. Abschließend wird das Konzept aus der Recherche und den Grundlagen erarbeitet.
Im Rahmen dieser Bachelorarbeit „Erstellung eines Webportals zur Einführung in die beruflichen Chancen und Möglichkeiten nach dem Augenoptik/Augenoptik- und Hörakustikstudium (B.Sc.)“ wird eine Webseite entwickelt, die die Studierenden und Bewerber im Studiengang Augenoptik/Augenoptik und Hörakustik an der Hochschule Aalen darüber informieren soll, welche beruflichen Perspektiven sich nach einem erfolgreichen Studium für sie ergeben könnten.
Um dies erreichen zu können, werden die zur Generierung der Webseite notwendigen Installationen vorgenommen. Hier wird zunächst auf die Entwicklungsumgebung und anschließend auf die Skriptsprache auf der die Webseite basiert eingegangen. Weiterhin wird das Datenbanksystem auf welches die Webseite zugreift um Inhalte bei Bedarf anzeigen zu können erläutert. Danach wird das zur Erzeugung der Webseite verwendete Programm WordPress und die Vorgehensweise bei der Absolventenbefragung vorgestellt.
Die Absolventen sollen hierbei nach der Kontaktaufnahme dem Verfasser Tätigkeitsbeschreibungen und ggf. Besonderheiten beim jeweiligen Bewerbungsverfahren zukommen lassen. Diese aus der Berufspraxis erhaltenen Berichte, werden anschließend zur Informationsbereitstellung anonymisiert in die Webseite integriert.
Nun wird in einem Vergleich festgestellt, dass andere Hochschulen in Deutsch-land in ihren Bachelorstudiengängen der Augenoptik/Optometrie und Hörakustik bisher kein zusätzlich entwickeltes Webseitenangebot mit Absolventenberichten bereitstellen.
Des Weiteren erfolgt eine Analyse eines Orientierungstests zur Studienorientierung und– Bewerbung. Hierbei wird erläutert, welche Vor- und Nachteile dieses Verfahren für Bewerber und Interessenten aufweist und welche Rolle das erarbeitete Konzept der vorliegenden Arbeit dabei spielt.
Nachdem das Forschungsgebiet der Selbsteinschätzung von Hörqualität bei Kindern und Jugendlichen im schulischen Alltag bislang kaum betrachtet wurde, setzt diese Studienarbeit
an dieser Stelle an.
Im Rahmen der Studie sollte bewiesen werden, dass es keine Unterschiede in der Hörqualität durch Selbsteinschätzung wie auch in der Hörqualität durch Fremdeinschätzung zwischen Cochleaimplantat- und Hörgeräteträgern gibt. Zudem sollte ermittelt werden, wie hoch die Hörqualität der einzelnen Versorgungsgruppen in Selbst- und Fremdeinschätzung ist.
Alle Daten wurden aus einer Gruppe von 21 Cochleaimplantatträgern (m = 9; w = 12) und einer Gruppe von 50 Hörgeräteträgern (m = 28; w = 22) erhoben. Die mittlere Altersgruppe der Cochleaimplantatträger lag bei „13 - 15 Jahren“, die der Hörgeräteträger „10 - 12 Jahren“. Im Durchschnitt waren alle Kinder seit mehr als 3 Jahren bilateral mit Hörsystemen versorgt.
Getestet wurde mittels neu entwickelten Fragebögen, bewertet anhand eines speziell dafür ausgelegten Punktesystems.
Die Hörqualität der Selbsteinschätzung konnte für beide Versorgungsgruppen mit „sehr gut“ bewertet werden. Die Ergebnisse der Hörqualität für die Fremdeinschätzung war für beide
Gruppen etwas schlechter und wurde als „gut“ eingestuft. Der größte Unterschied bestand in der Hörqualität der Selbst- und Fremdeinschätzung zusammen. Hier konnten die Cochleaimplantatträger eine „gute“, die Hörgeräteträger jedoch eine „sehr gute“ Hörqualität erreichen.
Kinder und Jugendliche mit Cochleaimplantaten schätzen ihre Hörfähigkeit in allen Bereichen der Hörqualität, sowohl in ihrer Selbst- als auch in ihrer Fremdeinschätzung schlechter ein, als
die Kinder und Jugendlichen mit Hörgeräten.
Ziel und Zweck der Arbeit:
In dieser Arbeit wurden die Visusergebnisse der häufig verwendeten ETDRS- und Landoltring-Sehzeichentafeln mit denen des Freiburg Visual Acuity Test (FrACT) verglichen. Zusätzlich wird ein Hauptaugenmerk auf den Vergleich zweier Eingabemethoden für den Freiburg Visual Acuity Test gelegt, um ein mögliches Verbesserungspotenzial dieser aufzudecken. Bei den verwendeten Eingabemethoden handelte es sich um einen dreh- und fühlbaren Landolting (FrACTh) und die Eingabe mit einer modifizierten Zahlentastatur (FrACTk). Ziel dieser Studie war es, quantitative Aussagen zu folgenden Messgrößen zu ermitteln:
(i) die Übereinstimmung des FrACTk und FrACTh,
(ii) deren Reproduzierbarkeit,
(iii) die Übereinstimmung der Visusergebnisse aller verwendeter Tests und
(iv) deren Reproduzierbarkeit zu quantifizieren.
Material und Methoden:
Als Probanden nahmen an der Studie 25 augengesunde Studenten der Hochschule Aalen (19 – 28 Jahre) teil. Der Fernvisus jedes Probanden lag, mit oder ohne Korrektion, bei 0,2 oder höher. Ausgeschlossen waren Studenten der höheren Semester (ab zweiten Semester) des Studiengangs Augenoptik und Hörakustik. Die Messungen wurden monokular vorgenommen und erfolgten in randomisierten Abfolge der einzelnen Tests. Jeder Test wurde zweimal durchgeführt. „Forced choice“ und das 60% Kriterium wurden streng eingehalten. Es wurde kein Feedback in Bezug auf die Korrektheit der gegebenen Antwort gegeben.
Ergebnisse: Übereinstimmung der Sehschärfeergebnisse des FrACTk und FrACTh: Die Differenz der Mediane der beiden Tests nach dem ersten Testdurchlauf beträgt 0,074 logMAR (0,7 Zeilen) wobei FrACTh (-0,117 logMAR) bessere Resultate liefert. Dies ist im zweiten Durchlauf ebenfalls der Fall (FrACTh -0,112 logMAR) wobei die Differenz der Mediane hier geringer ist und noch 0,048 logMAR (0.5 Zeilen entspricht). Da die Differenzen der Mediane geringer sind als 0,3 logMAR (3 Zeilen), besteht statistisch kein signifikanter Unterschied zwischen den beiden Tests.
Übereinstimmung aller verwendeter Tests (ETDRS-, Landoltringtafeln, FrACTh und FrACTk ) in Bezug auf die Sehschärfewerte: Im Vergleich aller verwendeter Tests liefert im ersten Testdurchlauf auch hier der FrACTh mit -0,117 logMAR die besten Resultate. Mit -0,043 logMAR sind die Ergebnisse des FrACTk am schlechtesten und sind denen der Landoltringtafeln mit -0,048 logMAR sehr ähnlich. ETDRS ist um 0,2 Zeilen schlechter als FrACTh mit -0,097 logMAR. Im zweiten Testdurchlauf sind die Werte für den FrACTh und ETDRS annähernd gleich während die Ergebnisse der Landoltringta-feln um 0,5 Zeilen auf -0,097 logMAR steigen. Der FrACTk liefert hier mit -0,064 logMAR einen Anstieg um 0,2 Zeilen. Die Differenzen der Mediane sind kleiner als 0,3 logMAR (3 Zeilen).
Reproduzierbarkeit aller verwendeter Tests: Die Reproduzierbarkeit lag beim Vergleich der beiden Testdurchläufe für FrACTk und FrACT bei 0,012 logMAR bei ETDRS und Landoltringtafeln gab es mit 0 logMAR keinen Unterschied. Beim Vergleich der Tests untereinander (nur erster Testdurchlauf wurde verglichen) ist die Reproduzierbarkeit der FrACTk um 0,041 logMAR besser als die des FrACTh. Mit Werten für ICC <0.77 ist eine hohe Korrelation gegeben.
Schlussfolgerung:
Die Übereinstimmungen als auch die Reproduzierbarkeiten der einzelnen Tests war im Vergleich mit den aufgeführten Vergleichsstudien hoch. Der FrACTh erzielte sehr gute Visusergebnisse wohingegen der FrACTk in dieser Studie die schlechtesten Werte diesbezüglich aufwies. Fortführend ist eine Weiterentwicklung der Eingabemethoden für den FrACT angeraten.
Ziel der vorliegenden Bachelorarbeit war es, ein Weblog für die studentische Kontaktlinsensprechstunde des Studiengangs Augenoptik an der Hochschule für Technik und Wirtschaft in Aalen zu erstellen. Im Rahmen der Sprechstunde werden Kunden durch die Studierenden mit Kontaktlinsen versorgt. Das Weblog soll sowohl den Kunden als auch den Studierenden als Informati-onsquelle sowie zur Vor- und Nachbereitung der Kontaktlinsensprechstunde dienen. Es wurde mithilfe der Software WordPress.org erstellt. Diese lag in der Version 3.5.1 auf einer externen Festplatte mit dem Betriebssystem Ubuntu Linux 12.04 LTS vor. Das erstellte Weblog setzt sich insgesamt aus 36 Seiten zusammen, wobei acht als Hauptseiten eingerichtet wurden. Insgesamt wurden 48 Bilder eingefügt um die verfassten Texte zu verdeutlichen. Außerdem wurde ein Glossar eingerichtet, dank dem sich die Leser Erklärungen zu verschiedenen Fachbegriffen anzeigen lassen können.
Materialien für individuelle Kontaktlinsen sind sehr vielfältig in Hinsicht auf ihre
Materialeigenschaften und Beschaffenheit. Einen Überblick über die
Eigenschaften bieten bereits diverse Sammelwerke in Buchform.
Das im Rahmen dieser Bachelorthesis „Erstellung eines Webportals zum
Vergleich von individuellen Kontaktlinsenmaterialien“ entstandene Webportal
www.lensmaterial.info
soll dem Benutzer eine übersichtliche Darstellung der verfügbaren Materialien
für individuelle Kontaktlinsen bieten. Darüber hinaus bietet das Webportal eine
Filterfunktion, um das optimale Kontaktlinsenmaterial bezüglich verschiedener
Voraussetzungen zu suchen. Die Datenbank umfasst neben den formstabilen
und weichen Materialien auch Listen von Material- und Kontaktlinsenherstellern.
Das Webportal soll nach Abgabe dieser Bachelorthesis weiter geführt und
ausgebaut werden.
Ziel der Arbeit:
Die Verwendung von Kompression in Hörsystemen ist heutzutage essenzieller Bestandteil jeder
Hörsystemanpassung. In vielen Forschungsprojekten wurde bis heute Hauptsächlich das
Augenmerk auf die Hochtonkompression gelegt, dabei gibt es nur wenige Studien die sich mit
der Tieftonkompression beschäftigen. In dieser Studie wurde gezielt mit der Kompression im
niederfrequenten Bereich von 160 - 800 Hz gearbeitet mit der Besonderheit, dass zusätzlich
Grenzfrequenzen im Bereich von 160 - 480 Hz und 640 - 800 Hz gesetzt wurden. Das Augenmerk
wurde dabei auf die Frage gelegt, ob definierte Grenzfrequenzen die zu Frequenzbändern
zusammengefasst werden das Sprachverstehen beeinflussen können?
Material und Methode:
An dieser Studie nahmen sieben Schülerinnen und Schüler teil. Die Schülerinnen und Schüler
nahmen freiwillig an der Studie Teil und durften die Teilnahme jederzeit beenden. Die
Teilnehmerinnen und Teilnehmer bekamen Testgeräte die in zwei verschiedenen Einstellungen
im Tieftonbereich mit einem CV von 2,5:1 eingestellt wurden. Dabei war Einstellung 1 mit
den Grenzfrequenzen 160 - 480 Hz und Einstellung 2 mit den Grenzfrequenzen 640 - 800 Hz
eingestellt. Jede Einstellung wurde jeweils eine Woche testgetragen und dann gemeinsam ausgewertet.
Ergebnisse:
Das bessere Sprachverstehen (Validierung durch den OlKiSa) wurde mit Einstellung 1 erreicht,
auch bei der allgemeinen Bewertung des Hörsystems in Alltagssituationen wurde Einstellung 1
besser bewertet als Einstellung 2.
Schlussfolgerung:
Vorausgehende Studien konnten belegen, dass die Tieftonkompression für hochgradig schwerhörige
im Tieftonbereich einen positiven Einfluss auf das Sprachverstehen haben. Des weiteren
konnte mit der vorliegenden Studie eine Tendenz nachgewiesen werden, dass Grenzfrequenzen
im Tieftonbereich ebenso positive Effekte erzielen können. Die Ergebnisse zeigen die Tendenz
zu den tieferen Frequenzen 160 - 480 Hz der Einstellung 1. Die Allgemeine Zufriedenheit und
der Tragekomfort der Hörsystemene für Einstellung 1 war ausschlaggebender als die Ergebnisse
für Einstellung 2.
Hintergrund: Die Sehschärfebestimmung ist die am häufigsten geprüfte Sehfunktion. Landoltringe und Buchstaben werden oftmals als Sehzeichen zur Sehschärfebestimmung verwendet. In dieser Studie werden vier Sehtestmetho-den miteinander verglichen, welche derartige Optotypen darbieten: Der Freiburg Visual Acuity Test (FrACT), unter Verwendung eines Nummernblocks (FrACTk), bzw. eines rotierbaren, haptischen Landoltrings (FrACTh) als Eingabegeräte, die Tübingen Landolt Chart, auf welcher Landoltringe nach den Vorgaben der ISO 8596 sowie DIN 58220 Teil 3 dargeboten werden und ETDRS-Sehzeichentafeln. Ziele der Studie waren es (i) den Unterschied zwischen der subjektiven Bewertung der Testmethoden durch Probanden selbst, sowie die Beurteilung des Zurechtkommens der einzelnen Versuchspersonen durch den Untersucher, unter Verwendung von visuellen Analogskalen (VAS) herauszufinden und hinsichtlich der Testdauer (ii) die Ermittlung der Inter-Test Reliabilität zwischen den Methoden und (iii) deren Test-Retest Reliabilität zu vergleichen. Es wird besonders auf die Untersuchungsergebnisse von FrACTk und FrACTh eingegangen.
Probanden und Methodik: Für die explorative Studie wurden 24 augengesun-de, erwachsene Studenten der Hochschule Aalen (davon 14 männlich und 10 weiblich) mit einer Sehschärfe von ≥ 0,2 (4/20) als Probanden untersucht. Sämtliche Studierende verschiedener Fachrichtungen waren mit den Methoden der Visusbestimmung bislang nicht vertraut. Dabei wurde nach Zufallsprinzip die monokulare Sehschärfe des Führungs- oder nicht führenden Auges bestimmt. Die vier Testmethoden wurden jeweils zweimal in einer kontrollierten, randomisierten Reihenfolge, welche vor Studienbeginn in einer Permutationskette festgelegt wurde und unter Gebrauch der Forced-Choice-Strategie durchgeführt.
Ergebnisse: Subjektive Einschätzung: FrACTk wurde von Probanden und Untersuchern gegenüber FrACTh präferiert (p<0,001). Der ETDRS-Test und FrACTk wurden gegenüber den Landolt-Tafeln und FrACTh bevorzugt. Testdauer: Die Durchführung des FrACTh dauerte durchschnittlich 1,5-mal länger als FrACTk (p<0,001). FrACTk und ETDRS-Test waren am schnellsten durchführbar mit einem Median im ersten Testdurchgang von 48,2 und 48,7 Sekunden (p>0,05). FrACTh und der Landoltringtafel-Test nahmen 68,2 Sekunden und 96,1 Sekunden in Anspruch (Median erster Testdurchgang, p>0,05). Alle Sehtests, welche als Optotype den Landoltring verwendeten, wiesen einen signifikant schnelleren zweiten Testdurchgang auf (p<0,05). Die zwei Testdurchgänge des ETDRS-Tests dauerten nahezu gleich lang (p>0,05).
Schlussfolgerung: Die Durchführung des FrACT ging mit dem Nummernblock schneller als mit dem haptischen Eingabegerät und wurde von den Probanden und Untersuchern bevorzugt. ETDRS-Tests und FrACTk waren hinsichtlich der absoluten Testzeiten kürzer als die Ausführung des FrACTh und des Landoltringtafel-Tests. Die schnellsten Tests wurden auch von Probanden und Untersuchern am besten bewertet.
Deflektometrie
(2015)
In der vorliegenden Bachelorarbeit wurde ein, im Zentrum für Optische Technologien neuartiger Aufbau, eingemessen, sowie eine Anleitung für diesen erstellt. Dieser Messaufbau basiert auf Deflektometrie. Es werden Messungen mit diesem Gerät durchgeführt. Für Vergleichsmessungen wir ein Interferometer (ALI 201) verwendet.
Es wird der aktuelle Stand der Technik in der Interferometrie und der Deflekto-metrie erklärt. Hierbei wird auch auf die allgemeine Funktionsweise beider Messtechniken eingegangen.
Anschließend werden die bei den Versuchsmessungen verwendeten Geräte allgemein erläutert. Das heißt der Aufbau und die Funktion eines Fizeau-Interferometers und eines Phase-Measuring-Deflektometers.
Außerdem wurde eine Bedienungsanleitung für das Deflektometer mit einem LED-Tunnel erstellt, welches ein Entwicklungsgerät von Zeiss ist. Schließlich werden Flächen mit verschiedenen Oberflächenstrukturen mit den Messgeräten ausgemessen. Die Messwerte mit dem Interferometer sollen als Vergleichswerte dienen, damit man die Messungen am Deflektometer bewerten und einschätzen kann. Es geht vor allem darum, zu sehen, welche Oberflächen mit dem Deflektometer produktiv vermessen werden können. Außerdem soll bei geeigneten Oberflächen die Wiederholbarkeit des Geräts anhand von 20 Wiederholungsmessungen getestet werden.
Ziel und Zweck der Arbeit: In dieser Arbeit wurden die Refraktionsergebnisse des sukzessiven und simultanen Kreuzzylinderabgleichs unter Verwendung der Sehzeichen „Punktewolke“ und „8“ dahingehend miteinander verglichen, ob beide Verfahren das gleiche Ergebnis liefern und ob die Refraktionsergebnisse der beiden Kreuzzylinderverfahren reproduzierbar sind. Des Weiteren fand ein Vergleich der ermittelten Sehschärfen, der subjektiven Bewertung der beiden Kreuzzylinderverfahren seitens der Probanden und des Untersuchers sowie der jeweiligen Messdauer statt.
Material und Methode: Die Studie wurde mit 24 augengesunden Probanden im Alter von 19-74 Jahren durchgeführt. Die Messungen erfolgten nach einer randomisierten Abfolge. Dabei wurde jeder Test zweimal vorgenommen.
Ergebnisse: Reproduzierbarkeit des sukzessiven und simultanen Kreuzzylinderabgleichs unter Verwendung der „Punktewolke“: Die mittlere Abweichung in der Differenz der sphärischen Äquivalente beträgt 0,01 dpt für den sukzessiven und -0,08 dpt für den simultanen Kreuzzylinderabgleich. Die Standardabweichung für J0 bzw. J45 betragen ±0,08 bzw. ±0,13 dpt für den sukzessiven und ±0,15 bzw. ±0,17 dpt für den simultanen Abgleich. Reproduzierbarkeit des sukzessiven und simultanen Kreuzzylinderabgleichs unter Verwendung der „8“: Für den sukzessiven Kreuzzylinderabgleich ergibt sich eine mittlere Abweichung von -0,01 dpt in der Differenz der sphärischen Äquivalente und eine Standardabweichung von ±0,09 dpt für J0 und ±0,10 dpt für J45. Die mittlere Abweichung in der Differenz der sphärischen Äquivalente für den simultanen Abgleich liegt bei -0,05 dpt, die Standardabweichung für J0 ist ±0,16 dpt und für J45 gleich ±0,13 dpt. Übereinstimmung der Sehzeichen „Punktewolke“ und „8“: Die Wahl des Sehzeichens hat einen geringeren Einfluss auf den sukzessiven Kreuzzylinderabgleich. Die Standardabweichung für J0= ±0,11 und für J45= ±0,11 dpt. Die Berechnungen für die simultane Kreuzzylindermethode ergeben eine Standardabweichung von ±0,19 dpt für J0 und ±0,13 dpt für J45. Übereinstimmung von sukzessivem und simultanem Kreuz-zylinderabgleich: In Bezug auf die sphärischen Äquivalente liefern beide Verfahren sowohl unter Darbietung der „Punktewolke“ als auch der „8“ vergleichbare Ergebnisse. Für die Kreuzzylinderkomponenten ergeben sich unterschiedliche Ergebnisse. Die Standardabweichungen betragen ±0,18 bzw. ±0,16 dpt für J0 bzw. J45 unter Darbietung des Sehzeichens „Punktewolke“. Bei Verwendung der „8“ ergibt sich eine Standardabweichung von ±0,25 dpt für J0 und ±0,12 dpt für J45.
Schlussfolgerung: Der sukzessive Kreuzzylinderabgleich weist sowohl unter Darbietung des Sehzeichens „Punktewolke“ als auch der „8“ im Vergleich zu den in dieser Arbeit im Kapitel Diskussion aufgeführten Studien eine hohe Reproduzierbarkeit auf. Im Gegensatz dazu ergeben sich für den simultanen Kreuzzylinderabgleich höhere Abweichungen. Bei Vergleich der beiden Kreuzzylindermethoden ergeben sich für die Kreuzzylinderkomponenten höhere Abweichungen im Vergleich zu den genannten Studien. Weitere Studien, in welchen zwei vergleichbare Gruppengrößen mit Zylinderstärken bis 1,5 dpt und über 1,5 dpt verglichen werden, werden angeraten.
Die Weiterentwicklung der Augenoptikgeschäfte im Bereich optometrische
Dienstleistungen ist ein aktuelles Thema, dass von großer Bedeutung ist. Doch
wie sehr ist die Weiterentwicklung in den Augenoptikergeschäften angekommen?
Welche Anteil haben diese am Umsatz und vor allem wie reagieren die
Kunden auf das vielfältige Angebot? Diese Fragen und mehr gilt es in dieser
Bachelorthesis "Optometrische Dienstleistungen - state-of-the-art im deutschsprachigen
Raum" zu erörtern.
Um Aufschluss über all diese Fragen zu bekommen wird eine Befragung
verschiedener Augenoptiker in Deutschland durchgeführt. Anhand deren
Ergebnisse werden wichtige Erkenntnisse über den aktuellen Stand der
Augenoptiker und deren Einstellung im Bereich optometrische Dienstleistungen
gemacht. Optometrische Dienstleistungen tragen noch nicht bedeutend zum
Umsatz und Gewinn bei, was sich aber in Zukunft ändern wird, dafür erbring es
dem Augenoptiker einen Imagegewinn und die Absetzung von Mitbewerbern und
dem Onlinehandel. Aber vor allem aufgrund der Kundenbindung sind optometrische
Dienstleistungen für die Augenoptiker so interessant.
Für eine optimale optometrische Untersuchung und ein kundenorientiertes
Beratungsgespräch bedarf es einer Vielzahl von Informationen über den
Kunden, die als allererstes im Rahmen einer Anamnese und Bedarfs- und
Wunschermittlung erfasst werden sollten. Eine vollständige Erhebung der
Kundeninformationen liefert die notwendige Grundlage für eine perfekte
augenoptische Versorgung.
Ziel dieser Abschlussarbeit ist es, ein Konzept für eine Applikation für den
Zeitraum zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung
zu entwerfen. Damit sollen die ersten beiden Phasen eines augenoptischen
Verkaufsgespräches strukturiert werden und eine effiziente Lösung auch in
Wartesituationen liefern. Mit der Einführung eines Befragungstools auf einem
Tablet-PC soll der Kunde zum einen auf die optometrische Untersuchung und
auf das bevorstehende Beratungsgespräch vorbereitet werden und zum anderen
soll die Beratungsqualität gesteigert werden.
Dazu wurden zunächst Interviews mit Geschäftsführern bzw. Filialleitern
augenoptischer Fachgeschäfte geführt, die vor allem Aufschluss über die Zeit
zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung geben
sollten.
Die Ergebnisse bestätigen, dass bei den meisten Augenoptikern die Zeit
zwischen dem Betreten des Ladenlokals und dem Beginn der Beratung
unzureichend genutzt wird. Des Weiteren hat sich gezeigt, dass sich dieser
Zeitraum bei allen befragten Augenoptikern aus Teilen einer Anamnese,
Bedarfsermittlung und Bedürfnisweckung zusammensetzt. Bei den meisten
Befragten allerdings existiert weder ein strukturierter Ablauf über den Inhalt
noch findet eine Dokumentation im Sinne der Arbeitsrichtlinien für Augenoptik
und Optometrie statt.
Die Ergebnisse der Interviews decken sich mit größeren Studien und bekräftigen
somit einen dringenden Handlungsbedarf im Bereich der Anamnese und
Bedarfsermittlung, was schließlich mit der Konzeption eines digitalen
Befragungstools verbessert werden könnte.
Aalener Schnell Satztest
(2014)
Im Folgenden befasst sich die hier vorliegende Bachelorarbeit mit der Modifikation eines
deutschsprachigen Satztests, dem HSM-Satztest, in Anlehnung an den
angloamerikanischen Schnelltest QuickSIN™. Mit diesem daraus entwickelten „Aalener
Schnell Satztest“ (ASS) wird eine weitere Alternative zu dem OlSa und GöSa, nach den
geltenden HilfsM-RL, erzielt, welcher zugleich der Norm DIN ISO 8253-3:2009-06 gerecht
wird. Zu Beginn wurde der Umfang der 600 aufgesprochenen Sätze des HSM-Satztests
auf drei Signalwörter, bestückt aus einem Subjekt, einem Objekt und einem Adjektiv,
selektiert. Parallel dazu ist das Störsignal CCITT-Rauschen durch ein unverständliches
Sprachsignal (HSMnoise), erzeugt aus dem Sprachmaterial des HSM-Satztests, ersetzt
worden. Nach dieser Vorarbeit, wurden die 24 selektierten Sätze in einem
Signal-Rausch-Abstand (SNR) von 2 dB SNR-Schritten wieder zu einem komplett
modifizierten Satztest, genannt ASS, zusammengefügt. Die Diskriminationsfunktion des
veränderten Sprachmaterials, wurde dieser an 22 normalhörende Probanden getestet.
Gesucht war der Wert, bei dem 50 % der getesteten Worte verstanden worden sind
(L50-Wert), wobei das definierte Störgeräusch, das generierte HSMnoise, zur Anwendung
kam. Der unveränderte HSM-Satztest erreicht einen durchschnittlichen SNR von - 7,2 dB
mit einer Steilheit von 7,5 %/dB. Verglichen mit dem Aalener Schnell Satztest ergab sich
ein SNR in Höhe von - 5,3 dB mit einer Steilheit von 12,1 %/dB (Testliste 1) und
andernfalls ein SNR in Höhe von - 3,3 dB SNR mit einer Steigung von 11,2 % (Testliste 2).
Die Dauer der Durchführung lässt sich auf ein Zeitfenster, je nach Mitarbeit des
Probanden, von drei bis vier Minuten einkalkulieren. Zur Wahrung der Validität des
Aalener Schnell Satztests gilt es, im Rahmen eines aufbauenden Projekts, weitere
Satzgruppen anzuknüpfen.
Das Auftreten einer Unverträglichkeit von Gleitsichtgläsern und die damit verbundene Unzufriedenheit werden in augenoptischen Kreisen kritisch diskutiert. Im deutsch-sprachigen Raum liegt bislang noch keine wissenschaftlich fundierte Datenbasis vor, die eine dauerhafte Unverträglichkeit von Gleitsichtgläsern belegt. Die vorliegende Arbeit soll aufzeigen, ob ein unzufriedener Gleitsichtbrillenträger durch eine optimale Versorgung mit für ihn individuell angefertigten Gleitsichtgläsern zu einem zufriede-nen Gleitsichtbrillenträger werden kann. Somit soll geklärt werden, ob die Unzufrie-denheit die Folge einer unabänderlichen Charakteristik des Brillenträgers ist, Gleit-sicht nicht zu vertragen. Zudem soll geprüft werden, wie groß der Einfluss bestimmter Bereiche des Sehens im Gleitsichtglas auf die Gesamtzufriedenheit ist und ob dieser sich abhängig vom Sehbereich unterscheidet. Dafür wurde im Zeitraum von Februar 2014 bis Juni 2015 eine multizentrische Studie mit 243 Probanden durchgeführt. Die Befragung zeigte, dass eine Steigerung der Gesamtzufriedenheit von 38,69 % er-reicht werden konnte. Am Ende der Testphase betrug die durchschnittliche Gesamt-zufriedenheit einen Wert von 81,25 %, welcher in die Kategorie der Zufriedenheit fällt. Von den 243 Probanden gaben 81,5 % an, dass ihre neue Gleitsichtbrille besser sei als ihre vorherige. Die Ergebnisse sprechen dafür, dass die Unzufriedenheit mit Gleitsicht keine unabänderliche Charakteristik ist, sondern mit einer optimalen Ver-sorgung die Zufriedenheit gesteigert werden kann. Hinsichtlich der Frage, welche Sehbereiche die Gesamtzufriedenheit am meisten beeinflussen, hat sich herausge-stellt, dass die Empfindung der Sehfeldbreite des mittleren Bereichs die größte Kor-relation mit der Gesamtzufriedenheit aufweist (0,803). Bezüglich der Sehqualität wurde die höchste Korrelation mit dem Sehen in der Nähe festgestellt (0,708). Gene-rell stellte sich heraus, dass Sehbereiche für nahe und mittlere Entfernungen einen größeren Einfluss auf die Gesamtzufriedenheit haben als Sehbereiche für weite Ent-fernungen. Auch hat sich gezeigt, dass die Empfindung der Sehfeldbreiten eine grö-ßere Auswirkung auf die Gesamtzufriedenheit hat als die Sehqualität in den entspre-chenden Bereichen.
Ziel und Zweck.
In dieser Studie wurde untersucht, ob die subjektive Höranstrengung durch die Anpassung von HighEnd Hörsystemen im Vergleich zur Anpassung von LowEnd Hörsystemen verringert wird und ob sich die subjektive Höranstrengung in Abhängigkeit des Grades des Hörverlustes und der Hörsystemwahl verändert oder nicht. Außerdem wurde der Einfluss der Tragezeit auf das Trageempfinden der Otoplastik untersucht.
Material und Methoden
Das Probandenkollektiv setzte sich aus insgesamt 37 Personen mit geringgradi-gem, mittelgradigem und hochgradigem binauralen sensorineuralen Hörverlust nach Pure Tone Average (PTA) zusammen. Jedem Probanden wurden in einer einfachblinden Studie vergleichend das Ex- Hörer- Basisgerät und das Ex- Hörer- Spitzengerät der Firma Hansaton (Hamburg) mit individuellen Otoplasti-ken auf Basis von NAL- NL2 angepasst.
Nach jeder Anpassung wurden die Probanden mittels Fragebögen zur subjekti-ven Höranstrengung in verschiedenen Alltagssituationen und beim Oldenburger Satztest befragt.
Ergebnisse
Die Hörsystemversorgung brachte bei den geringgradig Schwerhörigen eine signifikante Verbesserung in den Alltagssituationen 4 (durch beide Hörsysteme) und 3 (LowEnd System). Bei den Probanden mit mittelgradigem Hörverlust verbesserten sich durch HighEnd Hörsysteme drei Alltagssituationen (1, 3, 4) signifikant, durch LowEnd Geräte die Alltagssituation 2. Trotz beider Versorgun-gen empfanden alle Probanden den Oldenburger Satztest als anstrengend.
Schlussfolgerung
Insgesamt gaben alle Probanden eine Verringerung der Höranstrengung durch eine Versorgung mit Hörsystemen an. Die Verbesserung war vor allem bei den Alltagssituationen sichtbar. Es zeigte sich sowohl bei der Einstiegsklasse, als auch beim HighEnd Hörsystem ein großer Nutzen für die Probanden.
Die Bachelorthesis befasst sich mit der Messung des individuellen Insets im
Nahbereich bei 30 Probanden. Mögliche Ursachen einer Gleitsichtglasunverträglichkeit
sollen erkannt und dargestellt werden.
Die Messungen zur Konvergenzprüfung der Augen werden mit einem an der
Hochschule entworfenen Gerät durchgeführt. Die Probanden fixieren neun
verschiedene Messpunkte in einer Leseentfernung von 40 cm, während die
Probanden selbst mittels Kamerafunktion Bildaufnahmen ihrer Blickrichtung
aufnehmen. Zur besseren Reproduzierbarkeit wird der Messdurchgang vier Mal
wiederholt. Mit Hilfe der Bildaufnahmen wird das Konvergenzverhalten in der
Nähe genau studiert.
Für diese Studie wurden Probanden unterschiedlicher Altersstufen vermessen
und in zwei Gruppen eingeteilt (<45 Jahre und >45 Jahre).
Für den Insetwert existiert in der Industrie ein theoretischer Standardwert von
2,5 mm. Dieser Standardwert wird mit den individuell gemessenen Insetwerten
aller Probanden verglichen.
Diese Studie zeigt auf, dass einige Probanden deutliche Abweichungen zum
Standardwert aufweisen.
Eine weitere Erkenntnis ist die unterschiedlich starke Konvergenz der beiden
Augen untereinander. Der gemessene Insetwert des rechten Auges weicht oft
stark vom Insetwert des linken Auges ab.
Eine Folgerung für diese asymmetrische Konvergenz ist eine inkomplette
Ausnutzung der Nahbereiche in Gleitsichtgläsern. Des Weiteren kann dieses
auch eine Unverträglichkeit zu Gleitsichtgläsern hervorrufen.
Zusammenfassend zeigt sich, wie wichtig es ist die individuellen Parameter der
Nahzentrierung in die Glasherstellung miteinfließen zu lassen. Die individuelle
Messung des Insets ist äußerst wichtig und sollte generell durchgeführt werden.
Die Streifenprojektion hat sich im Laufe der letzten Jahre schnell neben den Koordinatenmessgeräten in der 3D-Messtechnik etabliert und ist aus diesem Bereich nicht mehr wegzudenken. Auch auf anderen Gebieten, wie beispielsweise der Medizin oder der Automobilindustrie, findet diese im Alltag Anwendung. Ein entscheidender Vorteil der Streifenprojektion besteht darin, Objekte schnell und berührungslos zu vermessen.
In der vorliegenden Bachelorarbeit wird detailliert auf ein selbstentwickeltes Streifenprojektionsgerät eingegangen, dass mit geringen finanziellen Mitteln konstruiert wurde. Hierbei wurde die Software zur Steuerung der Komponenten sowie zur Auswertung der erfassten Daten in Matlab erstellt.
Das Gerät wurde auf Benutzerfreundlichkeit untersucht und hinsichtlich dieses Aspektes verbessert. Im Zuge dessen beinhaltet die Bachelorthesis eine ausführliche Benutzeranleitung für Neuanwender.
Durch Transformation der Kalibrierung in metrische Daten kann das Streifenprojektionsgerät für zukünftige Messungen benutzt werden.
Es konnten die Fragen geklärt werden, wie reproduzierbar die Ergebnisse des Messgerätes sind und welche Messgenauigkeit erzielt werden kann. Zusätzlich erfolgte die Definition des erreichbaren Messvolumens.
Die Auswertung der durchgeführten Messversuche zeigte, dass das Gerät reproduzierbare Ergebnisse liefert. Außerdem konnte gezeigt werden, dass das Streifenprojektionsgerät in der Lage ist einfache Freiformflächen zu vermessen. Die erzeugten Messdaten können beispielsweise als Solldaten für die Vermessung mit taktilen Messmaschinen verwendet werden. Oberflächen welche scharfe Kanten, also nicht stetige Strukturen, besitzen, können mit diesem Aufbau nicht vermessen werden
Einleitung: Die Bachelorarbeit „Hörtraining bei hörgeschädigten Kindern und
Erwachsenen – Stand der Wissenschaft“ soll einen Überblick über das Thema
Hörtraining, die verschiedenen Arten des Trainings und bisher erfolgte und
publizierte Studien geben. In diesem Review soll hauptsächlich auf das
Hörtraining bei schwerhörigen Kindern und Erwachsenen eingegangen werden.
Ziel: Das Ziel der Übersichtsarbeit war es, einen ersten, strukturierenden
Überblick über die vorhandene Literatur zum Thema Hörtraining zu erarbeiten
sowie Studien zu dem Thema aufzuzeigen. Ebenso sollen folgende Fragen
beantwortet werden: Was ist ein Hörtraining? Was macht man bei einem
Hörtraining? Welchen Nutzen hat ein Hörtraining und für wen ist es geeignet?
Was sind die Auswirkungen eines Hörtrainings auf das Gehör? Gibt es
Zusammenhänge der Ergebnisse einzelner Studien? Welche Empfehlungen
erschließen sich für die Praxis?
Methodik: Um einen Überblick zu dem Thema zu bekommen wurde eine so
genannte nichtforschende, narrative Literaturübersicht gemacht. Dadurch konnte
ein großes Wissen erarbeitet werden. Im Rahmen der Recherche zu Studien zu
dem Thema Hörtraining bei Kindern und Erwachsenen wurden zunächst 526
Quellen identifiziert, von denen abschließend 22 Studien und Reviews in diese
Literaturübersicht eingebunden wurden. Die Studien, die sich mit dem Hörtraining
bei Erwachsenen (n=9) und mit dem Training bei Kindern (n=13) befassen,
wurden bearbeitet, systematisch in Tabellen aufgelistet, zusammengefasst und
diskutiert.
Ergebnisse: Durch Auswertung der Studien und Reviews geht hervor, dass auf
Basis der bisherigen Studienlage keine eindeutige Bestätigung der Wirksamkeit
des Hörtrainings stattfindet. Grund dafür ist, dass der aktuelle Stand der
Wissenschaft zum Thema Hörtraining noch recht wenig aussagekräftige
Resultate aufzeigt. Weitere Studien sollten durchgeführt werden. Erfahrungen
aus der Praxis und Erfahrungsberichte der Probanden zeigen, wie wichtig ein
Hörtraining für Hörbeeinträchtigte sein kann.
Fazit: Der Review bietet einen ersten Überblick über den Stand der Wissenschaft
zum Thema Hörtraining. In Zukunft bedarf es der Durchführung
aussagekräftigerer Studien um die Effektivität des Hörtrainings zufriedenstellend
zu beweisen.
Zielsetzung: Die Wahrnehmung des Menschen ist sehr vielfältig und noch nicht vollständig erforscht. Durch die Individualität und Einzigartigkeit des Menschen zusammen mit einer komplexen Gehirnleistung, welche noch unerforschte Lücken aufweist, stößt man immer wieder auf neue Strukturen. Eine bekannte ist der Wahrnehmungswechsel bei Kippbildern, die durch multistabile Stimuli verursacht werden. Überträgt man dieses Prinzip von der Optik auf die Akustik, führt es zum Ziel dieser Bachelorarbeit: Die Arbeit untersucht, ob Musiker beim Hören von multistabilen, isochronen Rhythmen bei deren Detektion einen Vorteil vor Nichtmusikern haben.
Methode:
Für die Messungen wird ein isochroner Rhythmus erstellt, den 40 Probanden –20 Musiker und 20 Nichtmusiker – hinsichtlich der Wahrnehmung von verschiedenen Rhythmusvarianten beurteilen. Dabei wird jeder wahrgenommene Variantenwechsel protokolliert und anschließend auf mögliche Abhängigkeiten und Einflüsse getestet.
Ergebnis:
Die Ergebnisse belegten, dass die musikalischen Probanden einen Vorteil vor den Probanden ohne musikalische Erfahrung haben. Die Musiker können schneller, öfter und überhaupt den Wechsel der Rhythmusvarianten wahrnehmen. Dabei ist es unerheblich, in welchem Alter der Musikunterricht begonnen wurde, ob immer noch aktiv musiziert wird, wie lang musiziert wurde oder welches Geschlecht die Probanden haben.
Ziel dieser Arbeit ist es, das Zielgruppenmodell Roper Consumer Styles (RCS)
der Gesellschaft für Konsumforschung (GfK) genau zu beschreiben und dessen
Anwendbarkeit auf die Augenoptik zu prüfen.
Zu Beginn werden die Geschichte und Entwicklung der Roper Consumer Styles
(RCS) sowie das Modell selbst und seine einzelnen Lebensstile erläutert. Im
zweiten Teil setzt sich diese Arbeit mit der Anwendung der Roper Consumer
Styles (RCS) in der Augenoptik auseinander. Es wird ein Pilotprojekt vom
Zentralverband der Augenoptiker (ZVA) und der Gesellschaft für Konsumforschung
(GfK) vorgestellt. Die Gesellschaft für Konsumforschung (GfK) bestimmt
das Einzugsgebiet des Optikers, analysiert die Kundschaft in dem Gebiet und
zeigt auf, bei welchen Zielgruppen noch Potenzial besteht. Der Optiker bekommt
von der Gesellschaft für Konsumforschung (GfK) konkrete Empfehlungen,
welche Marken und welche Designs die gewünschten Zielgruppen ansprechen.
Es ergeben sich vier Bereiche, in denen die Roper Consumer Styles (RCS) in
der Augenoptik angewandt werden können: Produkt/Sortimentspolitik, Preispolitik,
Kommunikationspolitik und Ladenbau/Schaufenstergestaltung. Anschließend
wird das Projekt einer kritischen Würdigung unterzogen. Dabei werden zwei
Verbesserungsvorschläge vorgebracht. Ein Vorschlag ist, die Fassungen nicht
nach Marken, sondern nach den Styles zu unterscheiden und eine Klassifizierung
der Fassungen nach den Roper Consumer Styles (RCS) zu machen. Der
andere Vorschlag ist, ein Kurzfragebogen zu entwickeln, der eine direkte
Einordnung des einzelnen Kunden nach den Roper Consumer Styles (RCS)
ermöglicht. Abschließend wurde eine Umfrage unter den Betrieben, die am
Projekt teilgenommen haben, durchgeführt. Die Ergebnisse der Umfrage zeigen,
dass das Zielgruppenmodell Roper Consumer Styles (RCS) in der Augenoptik
Anwendung findet und von den Optikern selbst auch als positiv bewertet wird.
Aus diesem Grund soll die Analyse der Gesellschaft für Konsumforschung (GfK)
in Zukunft für einen größeren Kreis von Betrieben angeboten werden.
Neben der subjektiven Bewertung der Hörsystemanpassung durch die Kunden und die Verifikation durch die Akustikerin/den Akustiker, in der Regel insitu, ist auch die Validierung einer Hörsystemanpassung nötig bzw. vorgeschrieben.
Der in der Hörgeräteakustik verbreitetste Test, um das Sprachverstehen zu testen, ist auch weiterhin der Freiburger Sprachtest.
Dieser findet nicht nur Anwendung bei Akustikerinnen und Akustikern, sondern auch bei HNO Ärztinnen und Ärzten. Somit ist er aus der Praxis nicht wegzudenken.
Neben den bekannten Problemen der ungleichen Listen und der mangelnden Eignung des Freiburger Sprachtests für Messungen im Störschall, haben jedoch alle Sprachtests gemein, dass sie nur akustisch und nicht visuell dargeboten werden.
Viele Schwerhörige, auch HörgeräteträgerInnen, nutzen jedoch im realen Leben neben der reinen akustischen auch die visuelle Information über das Mundbild der Sprecherin / des Sprechers. Diese Zusatzinformation kann die subjektive Höranstrengung deutlich reduzieren.
In dieser Studie wurde die Sprachverständlichkeit (SV) im Freiburger Sprachtest im Freifeld mit und ohne Videomaterial bei insgesamt 22 Personen und 6 Normalhörenden untersucht.
Das Ziel der vorliegenden Bachelorarbeit ist es, das Kaufverhalten der Vorgängergenerationen mit dem der Generationen Y und Z zu vergleichen und daraus resultierende Informationen über die Auswirkungen auf die Augenoptik in Deutschland zu erhalten, um den Markt besser zu verstehen und daraus zu lernen.
Dazu wurden zunächst das Kaufverhalten im Allgemeinen und die zugehörigen Segmente spezifiziert und alle Generationen mittels Literaturrecherche definiert und ihre Merkmale analysiert. Darauffolgend wurde das Kaufverhalten der einzelnen Generationen miteinander verglichen und die prägenden Merkmale der Generation Y und Z auf die Marktsituation in der Augenoptik übertragen.
Die im Rahmen dieser Bachelor Thesis "Verzeichnung und Brillenanpassung - Eine Visualisierung in Form von Drehbüchern" erarbeiteten Drehbücher dienen als Vorlage zur Erstellung von Lehrvideos in Form von Kurzfilmen mit einer Länge von drei bis vier Minuten.
Diese Kurzfilme sollen Kunden und Mitarbeitern der Firma Schneider das Verständnis für das jeweilige optische Thema erleichtern.
Es wurden Drehbücher zu den Themen "Anpassung und Zentrierung von Brillen" und "Verzeichnung und Schaukeleffekt bei Gleitsichtgläsern" erstellt.
Die angefertigten Drehbücher ermöglichen mit genauen Regieanweisungen und Layouts die spätere Umsetzung durch Dritte. Verschiedene Situationen und Darstellungen werden mit Skizzen und Anmerkungen vertieft. Die jeweiligen Bilder unterstützen die Veranschaulichung der einzelnen Szenen und erleichtern die Umsetzung vom Drehbuch zum Film. Zusätzlich gibt es in beiden Drehbüchern einen Text für den Sprecher.
Mit dieser Erzählstimme werden im Video die einzelnen Abbildungen und Szenen für den Betrachter leicht verständlich erklärt. Zudem wurde von beiden Drehbüchern ein Storyboard angefertigt, welches mit Kameraanweisungen und Szenenbeschreibungen den zeitlichen Ablauf des Videos darstellt.
Zusätzlich zu den Drehbüchern wurden die Grundlagen beider Themen in jeweils einem theoretischen Teil zusammenfassend erklärt.