Open Access
Refine
Year of publication
Document Type
- Bachelor Thesis (12)
- Master's Thesis (12)
- Article (9)
- Report (3)
Language
- English (36) (remove)
Is part of the Bibliography
- no (36) (remove)
Keywords
- Myopia (3)
- Studie (2)
- Adjustment Process (1)
- Affliliate Marketing (1)
- Agency Theory (1)
- Artificial Intelligence (1)
- Big Data (1)
- Choroidal thickness (1)
- City Development (1)
- Comparison metrics (1)
- Cross-Cultural Training (1)
- Cultural Heritage Marketing (1)
- Defocus (1)
- Diffusion (1)
- Digitization (1)
- Diversity Marketing (1)
- Edge Detection (1)
- Eye tracking (1)
- Fixation (1)
- Germany (1)
- Geschlechterrollen (1)
- Industrial Culture (1)
- Industrial Heritage (1)
- Kantendetektion (1)
- Kontaktlinse (1)
- Kontaktlinsen (1)
- Marketing (1)
- Messgerät, Brillengläser, Rotationszentrum, Auge (1)
- Multifocal contact lenses (1)
- Mustererkennung (1)
- Myopia Control (1)
- Myopie Kontrolle (1)
- National/Organizational Culture (1)
- Orthokeratologie (1)
- Orthokeratology (1)
- Scanpath (1)
- Share Repurchase (1)
- Strategic analysis (1)
- Strategische Analyse (1)
- Umweltanalyse (1)
- Undervaluation (1)
- Visual search (1)
- albinism (1)
- automotive supplier (1)
- contact lens-induced papillary conjuctivitis CLPC (1)
- customized (1)
- electric vehicle (1)
- environmental analysis (1)
- follicular-like conjunctivitis associated with siliconhydrogels FoCoSi (1)
- gender roles (1)
- genes (1)
- giant papillary conjuctivitis GPC (1)
- hybrid vehicle (1)
- low vision (1)
- measuring device, ophthalmic lenses, center of rotation, eye (1)
- melanin (1)
- myopia management (1)
- peripheral myopic defocus (1)
- powertrain (1)
- repeatability (1)
- soft multifocal contact lens (1)
- specialty coffee (1)
- stereoacuity threshold (1)
- stereopsis (1)
- stereotest (1)
- two-rod test (1)
- vision therapy (1)
Aim Patrick J. Caroline and Mark P. Andre first reported about soft lens orthokeratology in 2005. In a number of articles in the past five years, they reported about their research on this topic and their new findings. The aim of this study was to continue the research of Patrick J. Caroline and Mark P. Andre and to collect more information about the outcome of the technique. Methods Ten subjects with low myopia from -0.25 D to -1.25 D and a refractive astigmatism from plano to -0.75 D were fitted with a -10.00 D CIBA VISION AIR OPTIX® NIGHT&DAY® silicone hydrogel contact lens and were told to wear the lenses over night and everted. Corneal topography and refraction measurements were taken after one night, one week and one month of contact lens wear. Results Eight out of ten subjects finished the study, six female and two male. The mean age of the subjects was 23.9 years. With the eight subjects who finished the study, the mean change in subjective refraction was about +1.00 D in the sphere and +0.22 D in the cylinder, with maximum changes of +1.75 D sphere and +0.75 D cylinder. The mean apical power change, measured with the topographer, was 1.11 D. Changes in K - readings ranged from slight corneal steepening in both of the meridians to 0.23 mm of corneal flattening in the horizontal meridian and 0.27 mm of corneal flattening in the vertical meridian. Corneal eccentricity decreased about 0.65 on average. The main complaints and problems were the high minus power and the decentration of the contact lens and the occurrence of ghosting at night. Conclusion The results of this study show that everted wear of a high minus silicone hydrogel contact lens can lead to orthokeratology - such as changes in corneal topography and subjective refraction. These changes range from plano to +1.75 D sphere and +0.25 D to +0.75 D cylinder but are unpredictable and vary from subject to subject. Additional studies regarding the contact lens decentration and the unpredictability of the outcome need to be done to optimize the process.
The present thesis deals with alternative powertrains, focusing on electric vehicles
and hybrid vehicles and which of those alternative powertrains is considered as
sustainable for the future. It explores the question, which alternative powertrain is
worthwhile investing in for German automotive suppliers. The aim is to clarify
which of the two powertrains is already established on the market and what the
future prospects of those powertrains are. The question here is evaluated based on
the analysis of current literature as well as through the use of a SWOT analysis
and the use of the scoring model.
As a result it is clear that there is a need for alternative powertrains and the entire
automotive industry invests a lot in the development and research of alternative
powertrains. According to the German Federal Government, one million electric
vehicles should be on German roads by 2020. With pure electric vehicles, however,
the goal will be difficult to reach. Therefore, there is a lot of vested interest in
the development of hybrid vehicles on the market. It shows that the hybrid vehicle
has considerable advantages over the electric vehicle and the hybrid vehicle is
already seen as a transitional solution for pure electric vehicles. The hybrid vehicle
is also already established in the market and has better chances on the market
in the future. Therefore, it makes sense for German automotive suppliers to invest
in hybrid vehicles and to focus on this market, since there the chances of success
are greater and the future potential of this market is higher.
This paper aims to provide essential information about the formal aspects of the adjustment process companies in Southern Germany utilize to adjust their employees to new surroundings. In particular, it shall be investigated and defined what formal aspects are and when firms apply them. Literature shows that companies do implement language courses, intercultural trainings or provide further information about the host country before a stay abroad. Nevertheless, the phases during and after the assignment are not taken into account with the required importance. Additionally, since national culture can be broken down into different layers, the organizational culture as one layer was analyzed, too.By conducting a quantitative research among companies in Baden-Württemberg, this paper shows the different approaches for dealing with a stay abroad. Scientific literature about the topic of adjustment of globally assigned workers shall help emphasizing the need of a deeper cultural insight. Furthermore, by attempting to explain the organizations’ culture, a better understanding of the chosen training methods shall be created. Definitions in the beginning helped to understand the concept of culture, the notion and the phases of adjustment. Almost all collected data has been accessed either through JSTOR (a digital library founded to help academic libraries or publishers) or similar databases, through the companies’ websites or through the survey results it selves.The results of this research show that the phase before the stay abroad is organized well. Companies offer pre-departure training, but during and after the expatriate time a lack of support is being observed. The firms obviously underestimate the necessary help needed during the assignment and in the return phase, which is why the thesis attempts to fill this gap. Through the organizational culture, described on the companies’ webpages the author was able to draw a conclusion to the applied training methods, which results in a consistent overall picture of the described firms. Companies from the automotive sector had the highest return rate in the survey, which is why particular attention was paid to it.
This paper deals with the question of which factors have to be given for
successful share repurchases that create long-term shareholder value. Center of
the thesis is the agency theory and its influence on share repurchases. Based on
theoretical findings success factors for share repurchases are derived and then
verified by case studies.
The main drivers for a successful share repurchase elaborated by this paper are a
suitable long-term executive compensation, an independent board of directors and
a shareholder structure without a majority shareholder. Additionally the findings
show that tying repurchases to certain share price thresholds improves the quality
of share repurchases.
Ophthalmic lenses are ideally measured in accordance with the center of rotation of the eye. Therefore a measuring device was constructed due to this principle to measure lenses with a focimeter. In this work that measuring device was validated. Lenses of ± 4 dpt in spherical and aspherical design were measured across a field of 9x9 measuring points being at 5° distance from each other. This corresponds to a field of view of 40°. The measurement points in x- and y- direction were theoretically calculated to validate the measurement results. Regarding angles of incidence up to 20° it was supposed that the main optical aberration depends on a change in the sagittal and tangential sphere powers which is also defined as astigmatism. Therefore the calculation presents the tangential and sagittal oblique sphere powers depending on the different angles of the line of vision. On average the measurement results and the calculated data of the spherical designed lenses coincide quite good (correlation at 0,98), the systematic deviation of both values on average is 0.01 dpt and the random error (standard deviation) amounts 0.03 dpt on average. The minimum deviation is -0.06 dpt and the maximum is 0.09 dpt. Common focimeters have a measuring inaccuracy of up to 0.06 dpt (Diepes, Blendowske 2002). Therefore the quality of the measured data should be reliable. The aspherical designed lenses were compared to the spherical designed lenses. With increased angles of incidence the astigmatism of the aspherical lenses leads to lower values than the astigmatism of the spherical lenses
Purpose: Although the frequency in which practitioners are fitting scleral
contact lenses is increasing, the recommendation for proper tear layer depth
(thickness) varies amongst experts. The main goal of this paper is to clinically
verify the effect of varying tear layer depths on induced corneal edema during
lens wear.
Methods: Ten subjects with healthy eyes were fitted with scleral lenses on their
right eye. Each of them was fit with two different lenses: one with an apical
clearance of 200 μm and another with an apical clearance of 600 μm. They wore
the lenses for 8 hours on two different days, with at least a one week wash-out
period. Lenses were applied at 8 a.m. on each of the testing days. Pachymetry
measurements were taken one day prior to lens wear at 4 p.m., on the day of
wear prior to lens application, and after removal of the lenses at 4 p.m.
Measurements were collected using both the Pentacam® HR Corneal
Tomographer, as well as the Visante Anterior Segment Optical Coherence
Tomographer (OCT). The apical clearance was measured using the
Visante OCT at two intervals during the test day: immediately after application of
the lens and immediately prior to the removal of the lens.
Results: In this study, there was found to be no significant difference in corneal
edematous response during lens wear between the two test groups. The study
shows that the eyes with the lenses have a statistically significantly thicker
cornea compared to the non-lens-wearing eye after wearing either lens for 8
hours, lying within clinically and physiologically acceptable limits.
Conclusion: Our clinical results do not correlate with current theoretical
calculations, which predict a greater amount of corneal swelling with increasing
tear layer thickness. It has to be evaluated if the effect on corneal edema
changes with longer wearing periods, larger samples or other influences.
Key words: scleral (contact) lens, corneal edema, pachymetry, tear layer
thickness, vaulting, apical clearance
Abstract
1.1 Purpose
The purpose of this study is to prescribe follicular-like conjunctivitis associated with Siliconhydrogels
(FoCoSi) in silicone hydrogel contact lens wearers as a novel subtype of
the well prescribed contact lens induced papillary conjunctivitis (CLPC).
1.2 Methods
1211 patients who wore silicon hydrogels were included in this prospective, nonrandomised,
single center study. Subjective symptoms and clinical signs were evaluated
for daily wear (DW) and continuous wear (CW) populations for several (Lotrafilcon A,
Lotrafilcon B, Senofilcon A, Galyfilcon A) silicon hydrogel lens types. CCLRU and other
specifically developed grading scale were utilized for evaluation. Grading of 2 and above
was rated as clinically significant. Statistical evaluation was performed for eyes rather
than subjects.
1.3 Results
The clinical presentation of FoCoSi could be confirmed and showed an incidence of
3.8%. Lotrafilcon A followed by Senofilcon A on a CW modality presented, with a risk
ratio of 2.49 and 1.53 respectively, the highest affinity for developing FoCoSi. Fluorescein
positive spots showed the closest correlation with subjective symptoms reported
by patients and divided FoCoSi into an active and dormant form. Besides Protein, Lipid
deposition on the contact lens surface and air pollution like Ozone or fine and ultrafine
particles seems to be important factors in developing FoCoSi, whereas mechanical irritation
played a minor role.
1.4 Conclusion
FoCoSi is a novel and relevant subtype of CLPC. Further studies should be performed
to validate these findings and clear up several questions about the aetiology of FoCoSi
and CLPC.
Keywords: Giant papillary conjunctivitis (GPC), contact lens-induced papillary conjunctivitis
(CLPC), follicular-like conjunctivitis associated with siliconhydrogels (FoCoSi)
Purpose
The purpose of this study was to evaluate the validity of the iPad Aniseikonia Test for
measurement size lens-induced aniseikonia. The iPad Aniseikonia Test is a new
computer-based test designed for measuring aniseikonia in vertical direction. The iPad
Test uses red-green anaglyphs.
Methods
Aniseikonia was induced in 21 subjects by means of afocal size lenses. Resulting
aniseikonia was measured in vertical direction by the iPad Aniseikonia Test. The
measurement was performed in dark condition with appropriate correction of refractive
error. All subject were patients with normal vision with no anisometropia or other
ocular problem.
Results:
Afocal size lenses of known magnification were used to induce aniseikonia. 5
measurements were taken in each subject, ranging from zero to 7 % magnification.
When using the regression analysis, the slope of the fitted line significantly differs from
1. The average slope of regression line is 0,58.
Conclusions:
Only moderate accuracy was found for tested target size and orientation. In all cases the
iPad Aniseikonia Test underestimates the level of aniseikonia. However for gross
assessment of anisometropia in clinical practice it could be successfully used. Further
study with different target size should be addressed.
Purpose
The purpose of this study was to investigate the correlation of measured visual acuity
(VA) both static and dynamic obtained with static and dynamic measuring tests, as well
as, response time to visual stimulus and analysis of its influence on dynamic visual
acuity. The aim was to compare the results gathered for the three age groups and
analyze the possible differences.
Methods
The test groups consisted of 75 subjects between 10 and 60 years old, categorized in
three age groups. The measurements of static and dynamic visual acuity and reaction
time were conducted. The set of nine tests (five with radial magnification speed and four
simulating driving condition at 72 km/h and 130 km/h) was designed in order to measure
dynamic visual acuity and the set of two tests for reaction time measurement.
Results
Compared to static visual acuity in both tests, the results obtained with measurements
of dynamic visual acuity resulted in lower values depending on Landolt ring size and
magnification speed of animation. In average, the dynamic visual acuities in tests with
different magnification speeds were lower than static by 0.4 visual acuity units, or 31%
and the average of dynamic visual acuity after subtracting motoric component (reaction
time) was for 0.2 visual acuity worse than static or 15%. In the second test simulating
driving conditions at 72 km/h the average drop in dynamic visual acuity was 33% while
at 130 km/h average drop for younger and middle age groups was 37% and for older
group was 44% and after subtracting motor component values for 72 km/h speed
simulation average drop in visual acuity values was 23% for all three groups; for 130
km/h speed simulation younger and middle aged group average drop of visual acuity
was 20% and with older group it was 24%.
Conclusion
The tests used in this study were simple and fast and revealed significant difference
between static and dynamic visual acuity and influence of reaction time on dynamic
Nataša Vujko Muždalo Abstract
2
visual acuity values. It is hoped that this thesis will be a positive contribution in testing
and training of dynamic visual and sensory response skill with drivers, sportsmen and
people with visual-motor dysfunction.
Keywords: Dynamic visual acuity (DVA), static visual acuity (SVA), reaction time (RT),
motoric component, dynamic visual acuity test, reaction time test, radial increase in size
A good stereopsis (depth perception) is needed in everyday life, regardless whether a person is a professional driver or chef. Good estimation of distance, and of what is further and what closer, could mean the difference between a crushed and a whole car or between a bloody and a healthy finger. The main theme of this Master thesis is detect and quantify major factors in depth perception. Do the younger estimate the depth better than the older; do they have better depth perception with greater or smaller pupil distance; does depth perception depend on gender; what happens with stereopsis when vision is fogged by +0,5 and +1,0 D? These are the questions dealt with in this Master thesis.
To answer these questions measurements were made on 51 subjects (mean age 45,0 +/- 13,32 years) of whom 25 were women, mean age 45,5 +/-13,55 years (12 with PD<62 mm, mean and 13 with PD>66 mm) and 26 men, mean age 44,4 +/- 13,34 years (13 with PD<62 mm and, 13 with PD >66 mm). Each of these four groups was further divided by age (one in range 20 to 35 years and second in range 50 to 65 years).
The measurements were made with a few assumptions. The first assumption was that stereopsis is in direct correlation with visual acuity, the second assumption was that persons with bigger interpupillar distance have better stereopsis, and the third assumption was that with age the stereopsis ability decreases.
The measurements were done with modified Frisby–Davis test expanded from four geometrical shapes to twenty-five circles. The stereopsis was measured with full refractive correction at 4,5 and 3,0 meters. Later, stereopsis was measured with fogging with +0,5 and +1,0 D at the 4,5 and 3,0 meter distances.
Statistically there is no correlation (or very weak) between stereopsis and the visual acuity for whole group of 51 test persons, but if only young test persons are taken in consideration, the correlation becomes significant, r(20)=0,566, p=0,009 at 4,5 m and r(20)=0,456, p=0,043 at 3,0 m and that matches the assumption. Stereopsis is in no or weak positive correlation with pupil distance r(51)=0,059, p=0,679, which is in total contrast to the assumption. Stereopsis is in positive correlation with age at 4,5 meters measuring distance, r(51)=0,371, p=0,007, which corresponds to assumption. In addition, stereopsis is better in females than in males by 32,5%.
Based on the results it can be concluded that the stereopsis is in negative correlation with age, in positive correlation with visual acuity, females have better stereopsis than males and statistically, the correlation between stereopsis and pupil distance (PD) has not been proved. The most important conclusion is that the decreased visual acuity brings significant fall of stereopsis. A deficit in refraction of -0,50 D decreases stereo acuity by about 90% (nearly 2x) and a deficit of -1,0 D decreases stereo acuity by about 220% (about 3x).
Keywords: Stereopsis, stereo acuity, depth perception, pupil distance (PD), visual acuity (VA).